Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Phase Retrieval Using a Genetic Algorithm on the Systematic Image-Based Optical Alignment Testbed

NASA s Marshall Space Flight Center s Systematic Image-Based Optical Alignment (SIBOA) Testbed was developed to test phase retrieval algorithms and hardware techniques. Individuals working with the facility developed the idea of implementing phase retrieval by breaking the determination of the tip/tilt of each mirror apart from the piston motion (or translation) of each mirror. Presented in this report is an algorithm that determines the optimal phase correction associated only with the piston motion of the mirrors. A description of the Phase Retrieval problem is first presented. The Systematic Image-Based Optical Alignment (SIBOA) Testbeb is then described. A Discrete Fourier Transform (DFT) is necessary to transfer the incoming wavefront (or estimate of phase error) into the spatial frequency domain to compare it with the image. A method for reducing the DFT to seven scalar/matrix multiplications is presented. A genetic algorithm is then used to search for the phase error. The results of this new algorithm on a test problem are presented.

Taylor, Jaime R.↗

Optical eigenmode imaging

We present an indirect imaging method that measures both amplitude and phase information from a transmissive target. Our method is based on an optical eigenmode decomposition of the light intensity and the first-order cross correlation between a target field and these eigenmodes. We demonstrate that such optical eigenmode imaging does not need any a priori knowledge of the imaging system and corresponds to a compressive full-field sampling, leading to high image extraction efficiencies. Finally, we discuss the implications with respect to second-order correlation imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro-optics for imaging.

This project investigates the fundamental imaging capability of an optic with a physical thickness substantially less than 1 mm. The analysis assumes that post-processing can overcome certain restrictions such as detector pixel size and image degradation due to aberrations. A first order optical analysis quickly reveals the limitations of even an ideal thin lens to provide sufficient image resolution and provides the justification for pursuing an annular design. Some straightforward examples clearly show the potential of this approach. The tradeoffs associated with annular designs, specifically field of view limitations and reduced mid-level spatial frequencies, are discussed and their impact on the imaging performance evaluated using several imaging examples. Additionally, issues such as detector acceptance angle and the need to balance aberrations with resolution are included in the analysis. With these restrictions, the final results present an excellent approximation of the expected performance of the lens designs presented.

42 ENGINEERING↗

Fiber optic spectroscopic digital imaging sensor and method for flame properties monitoring

A system for real-time monitoring of flame properties in combustors and gasifiers which includes an imaging fiber optic bundle having a light receiving end and a light output end and a spectroscopic imaging system operably connected with the light output end of the imaging fiber optic bundle. Focusing of the light received by the light receiving end of the imaging fiber optic bundle by a wall disposed between the light receiving end of the fiber optic bundle and a light source, which wall forms a pinhole opening aligned with the light receiving end.

47 OTHER INSTRUMENTATION↗

High-resolution study of luminous infrared galaxies. I - The composite nature of the Seyfert 1 galaxy IRAS 20044-6114 (NGC 6860)

The physical conditions in the ionized gas, the stellar population, and the kinematics of the Seyfert 1 galaxy IRAS 20044-6114 (NGC 6860) are studied by high spatial resolution optical imaging and optical and near-IR spectroscopy of this luminous IR source. The broadband images show a compact nucleus, two weak spiral arms, a bar, a bulge, an inner ring, and a possible outer ring. The I-alpha image reveals bright emission-line regions associated with the Seyfert nucleus and an inner ring of intense star formation. The forbidden O III 5007-A image shows that the high-excitation gas is elongated perpendicularly to the direction of the bar, and reveals a bright compact object at about 40 arcsec NE of the nucleus which is undetectable in the broadband images. This object is interpreted as a dwarf young H II galaxy. The optical, near-IR, and FIR results show clear evidence that the nuclear and circumnuclear regions have composite and complex structure: a variable Seyfert 1 nucleus embedded in an intense and dusty star formation. environment.

Lipari, Sebastian↗

High-resolution CCD imagers using area-array CCD's for sensing spectral components of an optical line image

CCD imagers with a novel replicated-line-imager architecture are abutted to form an extended line sensor. The sensor is preceded by optics having a slit aperture and having an optical beam splitter or astigmatic lens for projecting multiple line images through an optical color-discriminating stripe filter to the CCD imagers. A very high resolution camera suitable for use in a satellite, for example, is thus provided. The replicated-line architecture of the imager comprises an area-array CCD, successive rows of which are illuminated by replications of the same line segment, as transmitted by respective color filter stripes. The charge packets formed by accumulation of photoresponsive charge in the area-array CCD are read out row by row. Each successive row of charge packets is then converted from parallel to serial format in a CCD line register and its amplitude sensed to generate a line of output signal.

Elabd, Hammam↗

The LCLS variable-energy hard X-ray single-shot spectrometer

The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10 -5 or better. Those performance goals have all been achieved during the commissioning of the HXSSS.

Rich, David↗

New insights of asteroid 4179 Toutatis using China Chang'e-2 close flyby optical measurements

The mysteries of near-Earth asteroid 4179 Toutatis have been more comprehensively unveiled by analyzing the optical images taken during the Chang'e-2 flyby in 2012. Compared with previous works, this paper concentrates on the photogrammetric relation between the Chang'e-2 spacecraft and Toutatis and the imaging shadow effect during the flyby. Accurate models of imaging and optical measurements are developed to study Toutatis's dimensions and rotational state at the time of imaging. As the illumination study shows, the shadowed region perpendicular to the long axis accounts for 27.78% of the Toutatis images, while the long axis of the body is fully captured. With a compensation on the shadow effect, the optical measurements reveal that Toutatis's long axis is 4354 ± 56 m, the maximum length is 4391 ± 56 m, and the spatial orientation described with the angles of direction cosine during the flyby is (126.°13 ± 0.°29, 122.°98 ± 0.°21, 126.°63 ± 0.°46). Furthermore, a new triaxial ellipsoid of 4354 × 1835 × 2216 m and a volume of 7.5158 km{sup 3} are proposed based on the previous Toutatis shape model. The effectiveness of the proposed method is validated, since typical features such as the neck and endpoints agree well with the results simultaneously observed by the ground radar. Moreover, it also potentially provides a feasible approach to precisely calculate the spin period of Toutatis.

79 ASTRONOMY AND ASTROPHYSICS↗

POD-based analysis of combustion images in optically accessible engines

This paper reports on 2D images of combustion-related luminosity taken in two optically accessible automobile engines of the most recent generation. The results are discussed to elucidate physical phenomena in the combustion chambers. Then, proper orthogonal decomposition (POD) is applied to the acquired images. The coefficients of the orthogonal modes are then used for the analysis of cycle variability, along with data of dynamic in-cylinder pressure and rate of heat release. The advantage is that statistical analysis can be run on a small number of scalar coefficients rather than on the full data set of pixel luminosity values. Statistics of the POD coefficients provide information on cycle variations of the luminosity field. POD modes are then discriminated by means of normality tests, to separate the mean from the coherent and the incoherent parts of the fluctuation of the luminosity field, in a non-truncated representation of the data. The morphology of the fluctuation components can finally be reconstructed by grouping coherent and incoherent modes. The structure of the incoherent component of the fluctuation is consistent with the underlying turbulent field. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Imaging arrangement and microscope

An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

42 ENGINEERING↗

Optical encryption interface

An analog optical encryption system based on phase scrambling of two-dimensional optical images and holographic transformation for achieving large encryption keys and high encryption speed. An enciphering interface uses a spatial light modulator for converting a digital data stream into a two dimensional optical image. The optical image is further transformed into a hologram with a random phase distribution. The hologram is converted into digital form for transmission over a shared information channel. A respective deciphering interface at a receiver reverses the encrypting process by using a phase conjugate reconstruction of the phase scrambled hologram.

Jackson, Deborah J.↗

Multimodal LA-ICP-MS and nanoSIMS imaging enables copper mapping within photoreceptor megamitochondria in a zebrafish model of Menkes disease

Here, copper is essential for eukaryotic life, and animals must acquire this nutrient through the diet and distribute it to cells and organelles for proper function of biological targets. Indeed, mutations in the central copper exporter ATP7A contribute to a spectrum of diseases, including Menkes disease, with symptoms ranging from neurodegeneration to lax connective tissue. As such, a better understanding of the fundamental impacts of ATP7A mutations on in vivo copper distributions is of relevance to those affected by these diseases. For this work, we combine metal imaging and optical imaging techniques at a variety of spatial resolutions to identify tissues and structures with altered copper levels in the Calamity gw71 zebrafish model of Menkes disease. Rapid profiling of tissue slices with LA-ICP-MS identified reduced copper levels in the brain, neuroretina, and liver of Menkes fish compared to control specimens. High resolution nanoSIMS imaging of the neuroretina, combined with electron and confocal microscopies, identified the megamitochondria of photoreceptors as loci of copper accumulation in wildtype fish, with lower levels of megamitochondrial copper observed in Calamity gw71 zebrafish. Interestingly, this localized copper decrease does not result in impaired photoreceptor development or altered megamitochondrial morphology, suggesting the prioritization of copper at sufficient levels for maintaining essential mitochondrial functions. Together, these data establish the Calamity gw71 zebrafish as an optically transparent in vivo model for the study of neural copper misregulation, illuminate a role for the ATP7A copper exporter in trafficking copper to the neuroretina, and highlight the utility of combining multiple imaging techniques for studying metals in whole organism settings with spatial resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for stimulated emission depletion projection stereolithography

The present disclosure relates to a system for forming a three dimensional (3D) part. The system may incorporate a beam delivery subsystem for generating optical signals, and a mask subsystem that receives the optical signals and generates optical images therefrom. A first one of the optical images activates a polymerization species of a photo-sensitive resin in accordance with illuminated areas thereof, to thus cause polymerization of select portions of the photo-sensitive resin to help form a layer of the 3D part. A second one of the optical images causes stimulated emission depletion of subportions of the polymerization species, simultaneously, over various areas of the layer, to enhance resolution of at least one subportion of the select portions of the photo-sensitive resin.

Hensleigh, Ryan↗

COOL-LAMPS. I. An Extraordinarily Bright Lensed Galaxy at Redshift 5.04

In this paper, we report the discovery of COOL J1241+2219, a strongly lensed galaxy at redshift z = 5.043 ± 0.002 with observed magnitude z AB = 20.47, lensed by a moderate-mass galaxy cluster at z = 1.001 ± 0.001. COOL J1241+2219 is the brightest lensed galaxy currently known at optical and near-infrared wavelengths at z $\gtrsim$ 5; it is ~5 times brighter than the prior record-holder lensed galaxy, and several magnitudes brighter than the brightest unlensed galaxies known at these redshifts. It was discovered as part of COOL-LAMPS, a collaboration initiated to find strongly lensed systems in recent public optical imaging data. We characterize the lensed galaxy, as well as the central galaxy of the lensing cluster using ground-based grizJH imaging and optical spectroscopy. We report model-based magnitudes, and derive stellar masses, dust content, metallicity, and star-formation rates via stellar-population synthesis modeling. Our lens mass modeling, based on ground-based imaging, implies a median source magnification of ~30, which puts the stellar mass and star-formation rate (in the youngest age bin, closest to the epoch of observation) at logM* = ${10.11}_{-0.26}^{+0.21}$ and SFR = ${27}_{-9}^{+13} M_⊙$ yr –1 , respectively. We constrain a star-formation history for COOL J1241+2219 consistent with constant star formation across ~1 Gyr of cosmic time, and that places this galaxy on the high-mass end of the star-forming main sequence. COOL J1241+2219 is two to four times more luminous than a galaxy with the characteristic UV luminosity at these redshifts. The UV continuum slope β = –2.2 ± 0.2 places this galaxy on the blue side of the observed distribution of galaxies at z = 5, although the lack of Lyα emission indicates dust sufficient to suppress this emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of contour images using optics of spiral beams

An approach is outlined to the recognition of contour images using computer technology based on coherent optics principles. A mathematical description of the recognition process algorithm and the results of numerical modelling are presented. The developed approach to the recognition of contour images using optics of spiral beams is described and justified. (image recognition)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the feasibility of optical-CT imaging in media of different refractive index

Purpose: Achieving accurate optical-CT 3D dosimetry without the use of viscous refractive index (RI) matching fluids would greatly increase convenience. Methods: Software has been developed to simulate optical-CT 3D dosimetry for a range of scanning configurations including parallel-beam, point, and converging light sources. For each configuration the efficacy of three refractive media was investigated: air, water, a fluid closely matched to PRESAGE{sup Registered-Sign }, and perfect matching (RI = 1.00, 1.33, 1.49, and 1.501 respectively). Reconstructions were performed using both filtered backprojection (FBP) and algebraic reconstruction technique (ART). The efficacy of the three configurations and the two algorithms was evaluated by calculating the usable radius (i.e., the outermost radius where data were accurate to within 2%), and gamma ({Gamma}) analysis. This definition recognizes that for optical-CT imaging, errors are greatest near the edge of the dosimeter, where refraction can be most pronounced. Simulations were performed on three types of dose distribution: uniform, volumetric modulated arc therapy (VMAT), and brachytherapy (Cs-137). Results: For a uniformly irradiated dosimeter the usable radius achieved with filtered backprojection was 68% for water-matching and 31% for dry-scanning in air. Algebraic reconstruction gave usable radii of 99% for both water and air (dry-scanning), indicating greater recovery of useful data for the uniform distribution. FBP and ART performed equally well for a VMAT dose distribution where less dose is delivered near the edge of the dosimeter. In this case, the usable radius was 86% and 53% for scanning in water and air, respectively. For brachytherapy, the usable radius was 99% and 98% for scanning in water and air, respectively using FBP, and a major decrease was seen with ART. Point source geometry provided 1%-2% larger usable radii than parallel geometry. Converging geometry recovered less usable dosimetry data (up to 10% reduced usable radii) than point and parallel geometries. A further disadvantage of converging geometry was an increased requirement on detector size by up to 18 Degree-Sign . Conclusions: For applications where dose information is not required in the periphery of the dosimeter, some dry and low-viscous matching configurations may be feasible. For all three dose distributions (uniform, VMAT, brachytherapy) the point source geometry produced slightly more favorable results (an extra 1%-2% usable radii) than parallel and converging. When dosimetry is required on the periphery, best results were obtained using close refractive matching and ART. A concern for water or dry-scanning is the increase in required detector size, introducing potential cost penalties for manufacturing.

36 MATERIALS SCIENCE↗

Proof of principle study: synchrotron X-ray fluorescence microscopy for identification of previously radioactive microparticles and elemental mapping of FFPE tissues

Biobanks containing formalin-fixed, paraffin-embedded (FFPE) tissues from animals and human atomic-bomb survivors exposed to radioactive particulates remain a vital resource for understanding the molecular effects of radiation exposure. These samples are often decades old and prepared using harsh fixation processes which limit sample imaging options. Optical imaging of hematoxylin and eosin (H&E) stained tissues may be the only feasible processing option, however, H&E images provide no information about radioactive microparticles or radioactive history. Synchrotron X-ray fluorescence microscopy (XFM) is a robust, non-destructive, semi-quantitative technique for elemental mapping and identifying candidate chemical element biomarkers in FFPE tissues. Still, XFM has never been used to uncover distribution of formerly radioactive micro-particulates in FFPE canine specimens collected more than 30 years ago. In this work, we demonstrate the first use of low-, medium-, and high-resolution XFM to generate 2D elemental maps of ~ 35-year-old, canine FFPE lung and lymph node specimens stored in the Northwestern University Radiobiology Archive documenting distribution of formerly radioactive micro-particulates. Additionally, we use XFM to identify individual microparticles and detect daughter products of radioactive decay. The results of this proof-of-principle study support the use of XFM to map chemical element composition in historic FFPE specimens and conduct radioactive micro-particulate forensics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗