Search NASA⌕ Search

SEARCH · Search NASA

Results for “Overview”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

America's Overview of Superconducting Science and Technology of Ingot Niobium

This contribution will present an overview of the results from R and D programs in the USA over the past four years towards the development of ingot Niobium as a viable alternative material to fabricate SRF cavities for particle accelerators. Activities at several laboratories and universities include fabrication, surface treatment and RF testing of single- and multi-cell cavities and studies of the thermal, mechanical and superconducting properties of samples from ingots of different purity. Possible advantages of ingot niobium over standard fine-grain (ASTM 6) are discussed and a streamlined treatment procedure to fully exploit those advantages is proposed.

36 MATERIALS SCIENCE↗

Overview of the PHENIX Longitudinal and Transverse Spin Physics Program

The PHENIX experiment uses polarized p+p collisions at RHIC to explore the spin structure of the proton. The p+p collisions, while complementary to deep inelastic lepton scattering experiments, offer distinct advantages for the determination of the helicity preferences of gluons, the flavor-dependence of sea antiquark polarizations, and parton transverse motion or spin orientation preferences inside polarized protons. The PHENIX experiment has been measuring the double longitudinal spin asymmetry of several inclusive probes to understand the gluon polarization in the allowed kinematic range. In addition, PHENIX experiment also has been studying the single spin asymmetries with a variety of final state particles in different kinematic regimes to shed light on the transverse spin structure. A brief overview is given of results to date and planned future directions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quasi-elastic Neutrino Scattering - an Overview

A non-technical overview of charge current quasi-elastic neutrino interaction is presented. Many body computations of multinucleon ejection which is proposed to explain recent large axial mass measurements are discussed. A few comments on recent experimental results reported at NuInt11 workshop are included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of Silicon Detectors in STAR: Present and Future

The STAR experiment at RHIC aims to study the QCD phase transition and the origin of the spin of the proton. Its main detector for charged particle track reconstruction is a Time Projection Chamber, which has been supplemented with a silicon detector involving two different technologies, in particular double-sided silicon strip and silicon drift technology. STAR is preparing now for a new Silicon Vertex Detector, using double-sided silicon strip, single-sided silicon strip-pads, and CMOS monolithic active pixel sensors technology, planned to take data in 2014. We give an overview of the design, calibration and performances of the silicon detectors used by the STAR experiment in the past and the expected performances of the future silicon detector upgrade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of nuclear energy: Present and projected use

Several factors will influence the contribution of nuclear energy to the future energy mix. Among them, the most important are the degree of global commitment to greenhouse gas reduction, continued vigilance in safety and safeguards, technological advances, economic competitiveness and innovative financing arrangements for new nuclear power plant constructions, the implementation of nuclear waste disposal, and, last but not least, public perception, information and education. The paper presents an overview of the current nuclear energy situation, possible development scenarios, of reactor technology, and of non-electric applications of nuclear energy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Overview of the present status and challenges of neutrino oscillation physics

This is an overview of the current status of neutrino oscillation physics, including atmospheric, solar, reactor and accelerator neutrino experiments. After summarizing our present understanding of all data, I discuss the open questions and how they might be addressed in the future. I also discuss how neutrinos can be used to learn about new physics and astrophysics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of LH experiments in JET with an ITER-like wall

An overview of the recent results of Lower Hybrid (LH) experiments at JET with the ITER-like wall (ILW) is presented. Topics relevant to LH wave coupling are addressed as well as issues related to ILW and LH system protections. LH wave coupling was studied in conditions determined by ILW recycling and operational constraints. It was concluded that LH wave coupling was not significantly affected and the pre-ILW performance could be recovered after optimising the launcher position and local gas puffing. SOL density measurements were performed using a Li-beam diagnostic. Dependencies on the D2 injection rate from the dedicated gas valve, the LH power and the LH launcher position were analysed. SOL density modifications due to LH were modelled by the EDGE2D code assuming SOL heating by collisional dissipation of the LH wave and/or possible ExB drifts in the SOL. The simulations matched reasonably well the measured SOL profiles. Observations of arcs and hotspots with visible and IR cameras viewing the LH launcher are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron based X-ray fluorescence activities at Indus-2: An overview

X-Ray fluorescence (XRF) spectrometry is a powerful non-destructive technique for elemental analysis of materials at bulk and trace concentration levels. Taking into consideration several advantages of the synchrotron based XRF technique and to fulfill the requirements of Indian universities users we have setup a microfocus XRF beamline (BL-16) on Indus-2 synchrotron light source. The beamline offers a wide range of usages – both from research laboratories and industries; and for researchers working in diverse fields. A brief overview of the measured performance of the beamline, design specifications including various attractive features and recent research activities carried out on the BL-16 beamline are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview spectra and axial distribution of spectral line intensities in a high-current vacuum arc with CuCr electrodes

Spectroscopic investigations of free-burning vacuum arcs in diffuse mode with CuCr electrodes are presented. The experimental conditions of the investigated arc correspond to the typical system for vacuum circuit breakers. Spectra of six species Cu I, Cu II, Cu III, Cr I, Cr II, and Cr III have been analyzed in the wavelength range 350–810 nm. The axial intensity distributions were found to be strongly dependent on the ionization stage of radiating species. Emission distributions of Cr II and Cu II can be distinguished as well as the distributions of Cr III and Cu III. Information on the axial distribution was used to identify the spectra and for identification of overlapping spectral lines. The overview spectra and some spectral windows recorded with high resolution are presented. Analysis of axial distributions of emitted light, which originates from different ionization states, is presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overview of ion source characterization diagnostics in INTF

INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High density plasmas and new diagnostics: An overview (invited)

One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including “volume-integrated” X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a “pin-hole camera” has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of multi-element monolithic germanium detectors for XAFS experiments at diamond light source

An overview of multi-element monolithic germanium detectors being used at the X-ray absorption spectroscopy (XAS) beam lines at Diamond Light Source (DLS) is being reported. The hardware details and a summary of the performance of these detectors have also been provided. Recent updates about various ongoing projects being worked on to improve the performance of these detectors are summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited)

Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. Finally, an overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the Wendelstein 7-X phase contrast imaging diagnostic

A phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. This diagnostic, funded by the U.S. Department of Energy through the Office of Fusion Energy Sciences, is a collaboration between the Max Planck Institute for Plasmaphysics, MIT, and SUNY Cortland. The primary motivation for the development of the PCI diagnostic is measurement of turbulent fluctuations, such as the ion temperature gradient, electron temperature gradient, and the trapped electron mode instabilities. Understanding how the magnetic geometry and other externally controllable parameters, such as the fueling method and heating scheme, modify the amplitude and spectrum of turbulence is important for finding operational scenarios that can lead to improved performance at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, as may arise from Alfvén eigenmodes or other MHD activity, for example. The PCI method creates an image of line-integrated variations in the index of refraction. For a plasma, the image created is proportional to the line-integral of electron density fluctuations. Here, this paper provides an overview of some key features of the hardware and the optical system and presents two examples of recent measurements from the W7-X OP1.2a experimental campaign.

47 OTHER INSTRUMENTATION↗

Overview of the SAS4A Metallic Fuel Models and Extended Analysis of a Postulated Severe Accident in the Prototype Gen-IV Sodium-Cooled Fast Reactor

The SAS4A safety analysis code, originally developed for the analysis of postulated severe accidents in oxide fuel sodium-cooled fast reactors (SFRs), has been significantly extended to allow the mechanistic analysis of severe accidents in metallic fuel SFRs. The SAS4A metallic fuel models simulate the metallic fuel thermomechanical and chemical behavior and track the evolution and relocation of multiple fuel and cladding components during the pretransient irradiation and during the postulated accident, allowing an accurate description of the changes in the local fuel composition. The local fuel composition determines the fuel thermophysical properties, such as freezing and melting temperatures, which in turn affect the fuel relocation behavior and ultimately the core reactivity and power history during the postulated accidents. Models describing the fuel-cladding interaction and eutectic formation, the effects of the in-pin sodium on the in-pin fuel relocation, and the postfailure reentry of the molten fuel and fission gas from the pin plenum have also been added. This paper provides an overview of the SAS4A key metallic fuel models emphasizing the postfailure metallic fuel relocation models included in the LEVITATE-M module of SAS4A. The capabilities of the SAS4A metallic fuel models are illustrated through an extended SAS4A analysis of a postulated unprotected loss-of-flow and transient-overpower accident in the metallic fuel prototype Gen-IV sodium fast reactor. The results show that the maximum relative power reached during the postulated accident is 1.19 P 0 . The favorable characteristics of the metallic fuel cause a significant decrease in net reactivity and relative power due to prefailure in-pin fuel relocation. Furthermore, negative net reactivity values persist after cladding failure, and the postfailure fuel relocation events occur at low and decreasing power levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Statistician’s Overview of Physics-Informed Neural Networks for Spatio-Temporal Data

The recent success of deep neural network models with physical constraints (so-called, Physics-Informed Neural Networks, PINNs) has led to renewed interest in the incorporation of mechanistic information in predictive models. Statisticians and others have long been interested in this problem, which has led to several practical and innovative solutions dating back decades. In this overview, we focus on the problem of data-driven prediction and inference of dynamic spatio-temporal processes that include mechanistic information, such as would be available from partial differential equations, with a strong focus on the quantification of uncertainty associated with data, process, and parameters. Here, we give a brief review of several paradigms and focus our attention on Bayesian implementations given they naturally accommodate uncertainty quantification. We then show that it is straight-forward to include the Bayesian PINN (B-PINN) within the Bayesian hierarchical model (BHM) framework that has long been considered for modeling dynamic spatio-temporal processes. Such a BHM-PINN is illustrated via a simulation study in which a latent nonlinear Burgers’ equation PDE governs the dynamics of Poisson distributed spatio-temporal data. Supplementary materials for this article are available online, including a standardized description of the materials available for reproducing the work.

Bayesian↗

Soot Particle Studies - Instrument Inter-Comparison – Project Overview

An inter-comparison study of instruments designed to measure the microphysical and optical properties of soot particles was completed. The following mass-based instruments were tested: Couette Centrifugal Particle Mass Analyzer (CPMA), Time-of-Flight Aerosol Mass Spectrometer - Scanning Mobility Particle Sizer (AMS-SMPS), Single Particle Soot Photometer (SP2), Soot Particle-Aerosol Mass Spectrometer (SP-AMS) and Photoelectric Aerosol Sensor (PAS2000CE). Optical instruments measured absorption (photoacoustic, interferometric, and filter-based), scattering (in situ), and extinction (light attenuation within an optical cavity). The study covered an experimental matrix consisting of 318 runs that systematically tested the performance of instruments across a range of parameters including: fuel equivalence ratio (1.8 {le} {phi} {le} 5), particle shape (mass-mobility exponent (D{sub f m}), 2.0 {le} D{sub f m} {le} 3.0), particle mobility size (30 {le} d{sub m} {le} 300 nm), black carbon mass (0.07 {le} m{sub BC} {le} 4.2 fg) and particle chemical composition. In selected runs, particles were coated with sulfuric acid or dioctyl sebacate (DOS) (0.5 {le} {Delta}r{sub ve} {le} 201 nm) where {Delta}r{sub ve} is the change in the volume equivalent radius due to the coating material. The effect of non-absorbing coatings on instrument response was determined. Changes in the morphology of fractal soot particles were monitored during coating and denuding processes and the effect of particle shape on instrument response was determined. The combination of optical and mass based measurements was used to determine the mass specific absorption coefficient for denuded soot particles. The single scattering albedo of the particles was also measured. An overview of the experiments and sample results are presented.

54 ENVIRONMENTAL SCIENCES↗

Dosimetry and uncertainty approaches for the million person study of low-dose radiation health effects: overview of the recommendations in NCRP Report No. 178

Purpose: Scientific Committee 6–9 was established by the National Council on Radiation Protection and Measurements (NCRP), charged to provide guidance in the derivation of organ doses and their uncertainty, and produced a report, NCRP Report No. 178, Deriving Organ Doses and their Uncertainty for Epidemiologic Studies with a focus on the Million Person Study of Low-Dose Radiation Health Effects (MPS). This review summarizes the conclusions and recommendations of NCRP Report No. 178, with a concentration on and overview of the dosimetry and uncertainty approaches for the cohorts in the MPS, along with guidelines regarding the essential approaches used to estimate organ doses and their uncertainties (from external and internal sources) within the framework of an epidemiologic study. Conclusions: The success of the MPS is tied to the validity of the dose reconstruction approaches to provide realistic estimates of organ-specific radiation absorbed doses that are as accurate and precise as possible and to properly evaluate their accompanying uncertainties. Further, the dosimetry aspects for the MPS are challenging in that they address diverse exposure scenarios for diverse occupational groups being studied over a period of up to 70 y. Specific dosimetric reconstruction issues differ among the varied exposed populations that are considered: atomic veterans, U.S. Department of Energy workers exposed to both penetrating radiation and intakes of radionuclides, nuclear power plant workers, medical radiation workers, and industrial radiographers. While a major source of radiation exposure to the study population comes from external gamma- or x-ray sources, for some of the study groups, there is also a meaningful component of radionuclide intakes that requires internal radiation dosimetry assessments.

61 RADIATION PROTECTION AND DOSIMETRY↗