Search NASA⌕ Search

SEARCH · Search NASA

Results for “PARAMAGNETISM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Magnetic Field, Force, and Inductance Computations for an Axially Symmetric Solenoid

The pumping of liquid oxygen (LOX) by magnetic fields (B field), using an array of electromagnets, is a current topic of research and development at Kennedy Space Center, FL. Oxygen is paramagnetic so that LOX, like a ferrofluid, can be forced in the direction of a B field gradient. It is well known that liquid oxygen has a sufficient magnetic susceptibility that a strong magnetic gradient can lift it in the earth's gravitational field. It has been proposed that this phenomenon can be utilized in transporting (i.e., pumping) LOX not only on earth, but on Mars and in the weightlessness of space. In order to design and evaluate such a magnetic pumping system, it is essential to compute the magnetic and force fields, as well as inductance, of various types of electromagnets (solenoids). In this application, it is assumed that the solenoids are air wrapped, and that the current is essentially time independent.

Lane, John E.↗

Ultra-Flexible Thermal Bus for Use in the Astro-H Adiabatic Demagnetization Refrigerator

The adiabatic demagnetization refrigerator (ADR) developed for the Astro-H Soft-X-ray Spectrometer (SXS) is a multi-stage solid-state cooler. It is capable of holding the SXS detector array at 0.050 K for greater than 24 hours with a recycle time of less than one hour. This quick recycle time relies upon high-conductivity thermal straps to couple the individual stages to a pair of heat switches without imposing a lateral load on the paramagnetic salt pills. To accomplish this we construct thermal straps using a technique of diffusion bonding together the ends of high-purity copper straps leaving the length between as individual foils. A thermal bus created this way has a thermal conductivity comparable to a solid strap of the equivalent thickness but with much-increased flexibility. The technique for selecting the base material, machining, cleaning, forming into final shape, and finally bonding together individual foils will be discussed along with examples of complete straps in various geometries.

Thermal Conductivity↗

Design and Application of Hybrid Magnetic Field-Eddy Current Probe

The incorporation of magnetic field sensors into eddy current probes can result in novel probe designs with unique performance characteristics. One such example is a recently developed electromagnetic probe consisting of a two-channel magnetoresistive sensor with an embedded single-strand eddy current inducer. Magnetic flux leakage maps of ferrous materials are generated from the DC sensor response while high-resolution eddy current imaging is simultaneously performed at frequencies up to 5 megahertz. In this work the design and optimization of this probe will be presented, along with an application toward analysis of sensory materials with embedded ferromagnetic shape-memory alloy (FSMA) particles. The sensory material is designed to produce a paramagnetic to ferromagnetic transition in the FSMA particles under strain. Mapping of the stray magnetic field and eddy current response of the sample with the hybrid probe can thereby image locations in the structure which have experienced an overstrain condition. Numerical modeling of the probe response is performed with good agreement with experimental results.

Wincheski, Buzz↗

Low-Thermal Conductivity Suspensions Used in the Isolation of the Salt Pills Aboard the Astro-H Adiabatic Demagnetization Refrigerator

An adiabatic demagnetization refrigerator (ADR) utilizes the magnetocholoric effect in a paramagnetic salt to produce sub-Kelvin temperatures. It is a solid-state device that has no moving parts and does not rely upon a density gradient in a working fluid. This makes it ideal for cooling space-based instruments. ·Typically the salt is enclosed in a cylindrical pill that is suspended within the bore of a magnet. The suspension between the salt pill and magnet must be robust enough to survive a launch yet have a thermal conductance that minimizes heat from the magnet that is mechanically, and thermally, anchored to a stage at a higher temperature. Here we detail such a design that uses Kevlar(Trade Mark) as the supporting media in a system that limits motion of the salt pill axial as well as laterally with respect to the magnet bore.

Kimball, Mark O.↗

Li-ion 18650 Thermal Runaway Particulate Analysis

Three types of atmospheres were tested for their effects on the particulates generated in a lithium ion (Li-ion) battery thermal runaway. Normal laboratory air (Ambient), a mixture of 23.5% O2/76.5% N2 meant to simulate the atmosphere on the International Space Station (ISS), and Vacuum environments were tested. Samsung 26F 18650 cells were driven to thermal runaway using heater tape, and the resultant particulates were collected analyzed using SEM/EDX, FTIR, GCMS, as well as conductivity and magnetic probes. All three conditions generated dense black particulate films composed of very fine carbon and metal particles. These films, however, were not very conductive, though individual particulates would be, and the particles demonstrated weak paramagnetism. FTIR and GCMS identified a substantial amount of volatile components in the particulate films, both organic partial combustion products, but also electrolyte salt products.

Nemanick, E. Joseph↗

Discreditation of Bobdownsite and the Establishment of Criteria for the Identification of Minerals with Essential Monofluorophosphate (PO3F2-)

Bobdownsite, IMA number 2008-037, was approved as a new mineral by the Commission on New Minerals, Nomenclature and Classification (CNMNC) as the fluorine endmember of the mineral whitlockite. The type locality of bobdownsite is in Big Fish River, Yukon Canada, and bobdownsite was reported to be the first naturally occurring mineral with essential monofluorophosphate (PO3F2-). The type specimen of bobdownsite has been reinvestigated by electron probe microanalysis (EPMA), and our data indicate that fluorine abundances are below detection in the mineral. In addition, we conducted detailed analysis of bobdownsite from the type locality by gas chromatography isotope ratio mass spectrometry, Raman spectroscopy, EPMA, and NMR spectroscopy. These data were compared with previously published data on synthetic monofluorophosphate salts. Collectively, these data indicate that bobdownsite is indistinguishable from whitlockite with a composition along the whitlockite-merrillite solid solution. Bobdownsite is therefore discredited as a valid mineral species. An additional mineral, krásnoite, has been purported to have monofluorophosphate components in its structure, but reexamination of those data indicate that F- in krásnoite forms bonds with Al, similar to OH- bonded to Al in perhamite. Consequently, krásnoite also lacks monofluorophosphate groups, and there are currently no valid mineral species with monofluorophosphate in their structure. We recommend that any future reports of new minerals that contain essential monofluorophosphate anions be vetted by abundance measurements of fluorine, vibrational spectroscopy (both Raman and FTIR), and where paramagnetic components are permissibly low, NMR spectroscopy. Furthermore, we emphasize the importance of using synthetic compounds containing monofluorophosphate anions as a point of comparison in the identification of minerals with essential monofluorophosphate. Structural data that yield satisfactory P-F bond lengths determined by X-ray crystallography, coupled with direct chemical analyses of fluorine in a material do not constitute sufficient evidence alone to identify a new mineral with essential monofluorophosphate anions.

McCubbin, Francis M.↗

Percolation Behaviour in the Magnetic Permeability and Electrical Conductivity in Conducting Magnetic - Insulating Non Magnetic Binary Composites

Experimental results of the complex magnetic permeability (µ) and the electrical conductivity (σ) of a granular paramagnetic Gadolinium Gallium Garnet (GGG: 0.3–26 vol%) and Teflon (PTFE) system are presented and discussed in relation to previously published (conductivity) and unpublished (permeability) studies on granular Fe3O4 – talc and Ni – talc wax systems. In these systems plots of the real conductivity (σ'(sub m)) against the volume fraction (φ) lie on characteristic sigmoid curves that when fitted to the Two Exponent Phenomenological Percolation Equation (TEPPE) confirm the existence of “percolation microstructures” with critical volume fractions (φ(sub c)). The plots of the real and imaginary permeability (µ'(sub m)) and (µ"(sub m)) satisfactorily fit to the TEPPE using the φ(sub c) obtained in each case from the “conductivity” measurements. In all three cases the conductivity results gave the exponent t > 2, and the permeability results gave t < 1.

David S McLachlan↗

Magnetic Calorimeter Option for the Lynx X-Ray Microcalorimeter

One option for the detector technology to implement the Lynx x-ray microcalorimeter (LXM) focal plane arrays is the metallic magnetic calorimeter (MMC). Two-dimensional imaging arrays of MMCs measure the energy of x-ray photons by using a paramagnetic sensor to detect the temperature rise in a microfabricated x-ray absorber. While small arrays of MMCs have previously been demonstrated that have energy resolution better than the 3 eV requirement for LXM, we describe LXM prototype MMC arrays that have 55,800 x-ray pixels, thermally linked to 5688 sensors in “hydra” configurations, and that have sensor inductance increased to avoid signal loss from the stray inductance in the large-scale arrays when the detectors are read out with microwave superconducting quantum interference device multiplexers, and that use multilevel planarized superconducting wiring to provide low-inductance, low-crosstalk connections to each pixel. We describe the features of recently tested MMC prototype devices and simulations of expected performance in designs opti- mized for the three subarray types in LXM.

Stevenson, Thomas R.↗

Miniature Magnetic Resonance Spectrometers

For the purpose of in-situ planeatry exploration, such as chemical characterization of Martian surface materials by miniature instruments, we have developed miniature Magnetic Resonance Spectrometers (MRS) namely, Nuclear Magnetic Resonance (NMR) and Electron Paramagnetic Resonance (EPR) spectrometers at JPL.

Proton-NMR↗

Position-Sensitive Magnetic Calorimeters for Lynx

We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pixels compared to the number of readout channels (called hydra). The detector consists of a 5×5 array of gold absorbers thermally coupled to a paramagnetic sensor. Since each absorber has a different thermal link to the sensor, it generates a different pulse shape and enables discrimination of pixel position. Recently, we have been successfully able to discriminate 25 averaged pulse shapes by means of rise-time and pulse height. The measured pulse shapes and distribution agree well with the modeling results. The estimated energy resolutions based on the pulse height and noise data we measured are 2.8–3.7 eV for MnKα X-ray photons at 50 mK.

Magnetic calorimeters↗

Biology and Medicine, Fall 1965 Semiannual report

Reports on radiation medicine, radiobiology, EPR STUDIES of OH radicals in ice, radiation doses on manned space missions, silicon detectors, and recovery of yeast after irradiation

X-RAY IRRADIATION↗