Cardiovascular Session Summary

It was apparent that the bed-rest and spaceflight data indicated that decreases in plasma volume and cardiac atrophy along with cardiac remodeling were fundamental changes which predisposed many astronauts to post flight orthostatic intolerance. Despite the recently acquired in-flight and post-flight muscle sympathetic nerve activity findings suggesting that the sympathetic nerve responses were appropriate there remains significant contrary data from bed-rest studies, post- flight stand tests and hind-limb unweighted rat studies that suggest that the vasoconstrictive responses were compromised at least insufficient in susceptible individuals. The key issues raised is whether a diminished increase in sympathetic activity from baseline without changes in 254 First Biennial Space Biomedical Investigators'Workshop Cardiovascular peak response or receptor adaptations is an abnormal response or is an individual variance of response to the accentuated decrease in stroke volume. Data relating autonomic neural control of heart rate were presented to suggest that the vagal and sympathetic control of heart rate was attenuated. Also, bed-rest and space flight induced attenuated baroreflex control of heart rate was shown to be restored to pre-bedrest function by one bout of maximal dynamic exercise. However, these data were confounded by relying on the use of R-R interval as a measure of efferent responses of the baroreflex during a condition in which the baseline heart rate was changed. Clearly the idea that the autonomic control of heart rate may be changed by microgravity needs further investigation. This direction is suggested despite the fact that in the triple product (HR x SV x TPR = MAP) assessment of the regulation of arterial blood pressure during orthostasis the role of the HR reflex may be less influential than that associated. with cardiac atrophy (SV changes) and aberrant sympathetic vasoconstriction (resistance) changes. Although sympathetic nerve activity responses in-flight and post-flight on neurolab appeared appropriate, enough bed-rest and post-flight stand test data, along with animal model data suggest that vasoconstriction was compromised. The mechanism of this compromised vasoconstriction needs to be delineated. Other major findings concerning microgravity and physiological regulatory systems are that: I . Thermoregulatory adaptation appear to suggest some decrements in the control of cutaneous vasodilation and sweating; 2. Calcium resorption and dietary calcium need to be defined for differing durations of spaceflight, especially as the effects of excess calcium on vasomotor function appears to be detrimental; 3. Neurohumoral mechanisms of microgravity induced changes in neural function and the regulation of plasma volume and total body water, bone resorption and autonomic neural control of the circulation need further delineation; 4. As performance of work tasks become prolonged, the mechanisms of blood pressure regulation in microgravity needs to be used in the recovery period from prolonged work tasks.

Raven, Peter↗

Communication Delays in Cislunar Space: A Lab Study Examining Human System Integration Architecture (HSIA) and Team Risk Concerns

BACKGROUND: Communication delays are an inherent challenge of space missions to the Moon and beyond. Past research studies showed that 50+ second delays adversely affected individual well-being, team cohesion, and overall task performance (Kintz et al., 2016; Larson et al., 2019). However, there is a dearth of research on the effects of shorter delays (on the order of 4-12 seconds one-way) that may present a more immediate challenge during the upcoming Artemis missions. Even these shorter delays could make it difficult or infeasible for ground control to provide real-time support to Artemis astronauts, especially in complex and time-critical tasks such as extra-vehicular activities (EVAs). Results from studies on longer or Mars-like delays cannot be directly applied to Artemis-like delays, due to the large differences in delay magnitude and task types between these mission categories. For example, real-time oversight and guidance from ground control is impossible under Mars-like delays but may be performed under Artemis-like delays, albeit with potentially high workload and communication difficulty. Thus, a better understanding of the effects of Artemis-like communication delays on collaborative task performance is needed. Additionally, there is a need to develop reliable task paradigms that can be used in future studies on communication delays. METHODS: This project will study the effects of Artemis-like communication delays on collaborative task performance in a simulated space-to-ground team task via a lunar Gateway-like interface prototype. Teams of two astronaut-like participants - one serving as “crewmember” and one as “flight controller” - will perform a spaceflight-relevant task under six delay conditions (i.e., 0, 4, 6, 8, 10, and 12 seconds). Audio, video, texting, and file transfer will be delayed between the participants to mimic lunar-like communication delays. Measures related to workload, situation awareness, system usability, task performance, team cohesion, well-being, and communication strategies will be collected. These measures will be compared across delay levels, participant roles, and off-nominal and nominal tasks. Participants will be given the choice to use any combination of video and text communication in order to study preferences in interaction modality. RESEARCH AIMS: One aim is to identify a delay level or range of levels at which there may be significant decrements in individual and team-based measures. Identifying such ranges may help design novel workload management or communication countermeasures for future space missions. Also, the spaceflight-relevant research tasks and corresponding communication delay technology developed as part of this effort may be used for future studies on communication delays. Results from this work are also expected to inform study scenarios in the Human Exploration Research Analog (HERA) Campaign.

S Upasani↗

Effects of Spaceflight on Bone: The Rat as an Animal Model for Human Bone Loss

The loss of weight bearing during spaceflight results in osteopenia in humans. Decrements in bone mineral reach 3-10% after as little as 75-184 days in space. Loss of bone mineral during flight decreases bone strength and increases fracture risk. The mechanisms responsible for, and the factors contributing to, the changes in bone induced by spaceflight are poorly understood. The rat has been widely used as an animal model for human bone loss during spaceflight. Despite its potential usefulness, the results of bone studies performed in the rat in space have been inconsistent. In some flights bone formation is decreased and cancellous bone volume reduced, while in others no significant changes in bone occur. In June of 1996 Drs. T. Wronski, S. Miller and myself participated in a flight experiment (STS 78) to examine the effects of glucocorticoids on bone during weightlessness. Technically the 17 day flight experiment was flawless. The results, however, were surprising. Cancellous bone volume and osteoblast surface in the proximal tibial metaphysis were the same in flight and ground-based control rats. Normal levels of cancellous bone mass and bone formation were also detected in the lumbar vertebrae and femoral neck of flight rats. Furthermore, periosteal bone formation rate was found to be identical in flight and ground-based control rats. Spaceflight had little or no effect on bone metabolism! These results prompted us to carefully review the changes in bone observed in, and the flight conditions of previous spaceflight missions.

Halloran, B.↗

BeyondPlanck: V. Minimal ADC Corrections for Planck LFI

We describe the correction procedure for Analog-to-Digital Converter (ADC) differential non-linearities (DNL) adopted in the Bayesian end-to-end BEYONDPLANCK analysis framework. This method is nearly identical to that developed for the official Planck Low Frequency Instrument (LFI) Data Processing Center (DPC) analysis, and relies on the binned rms noise profile of each detector data stream. However, rather than building the correction profile directly from the raw rms profile, we first fit a Gaussian to each significant ADC-induced rms decrement, and then derive the corresponding correction model from this smooth model. The main advantage of this approach is that only samples which are significantly affected by ADC DNLs are corrected, as opposed to the DPC approach in which the correction is applied to all samples, filtering out signals not associated with ADC DNLs. The new corrections are only applied to data for which there is a clear detection of the non-linearities, and for which they perform at least comparably with the DPC corrections. Out of a total of 88 LFI data streams (sky and reference load for each of the 44 detectors) we apply the new minimal ADC corrections in 25 cases, and maintain the DPC corrections in 8 cases. All these corrections are applied to 44 or 70 GHz channels, while, as in previous analyses, none of the 30 GHz ADCs show significant evidence of non-linearity. By comparing the BEYONDPLANCK and DPC ADC correction methods, we estimate that the residual ADC uncertainty is about two orders of magnitude below the total noise of both the 44 and 70 GHz channels, and their impact on current cosmological parameter estimation is small. However, we also show that non-idealities in the ADC corrections can generate sharp stripes in the final frequency maps, and these could be important for future joint analyses with the Planck High Frequency Instrument (HFI), Wilkinson Microwave Anisotropy Probe (WMAP), or other datasets. We therefore conclude that, although the existing corrections are adequate for LFI-based cosmological parameter analysis, further work on LFI ADC corrections is still warranted.

79 ASTRONOMY AND ASTROPHYSICS↗

Current ISS Exercise Countermeasures: Where are we now?

Current International Space Station (ISS) crew schedules include 1.5 h/d for completion of resistive exercise and 1 h/d of aerobic exercise , 6 d/wk. While ISS post flight decrements in muscle strength, bone m ineral density, and aerobic capacity improved in some crewmembers, de conditioning was still evident even with this volume of exercise. Res ults from early ISS expeditions show maximum loss in bone mineral density of the lumbar spine and pelvis in excess of 1.5% per month, with all crewmembers demonstrating significant bone loss in one or more re gions. Similarly, post flight muscle strength losses in the hamstring and quadriceps muscle groups exceeded 30% in the immediate post miss ion period in some crewmembers. Measures of aerobic capacity early in the mission show average decrements of 15%, but with onboard aerobic exercise capability, the crew has been able to "train up" over the co urse of the mission. These findings are highly variable among crewmem bers and appear to be correlated with availability and reliability of the inflight resistive exercise device (RED), cycle ergometer, and t readmill. This suite of hardware was installed on ISS with limited op erational evaluation in groundbased test beds. As a result, onorbit hardware constraints have resulted in inadequate physical stimulus, d econditioning, and increased risk for compromised performance during intra and extravehicular activities. These issues indicate that the c urrent ISS Countermeasures System reliability or validity are not ade quate for extendedduration exploration missions. Learning Objective: A better understanding of the status of ISS exercise countermeasures , their ability to protect physiologic systems, and recommendations for exploration exercise countermeasures.

Hayes, J. C.↗

An Experimental Study of the Effect of Wake Passing on Turbine Blade Film Cooling

The effect of wake passing on the showerhead film cooling performance of a turbine blade has been investigated experimentally. The experiments were performed in an annular turbine cascade with an upstream rotating row of cylindrical rods. Nickel thin-film gauges were used to determine local film effectiveness and Nusselt number values for various injectants, blowing ratios, and Strouhal numbers. Results indicated a reduction in film effectiveness with increasing Strouhal number, as well as the expected increase in film effectiveness with blowing ratio. An equation was developed to correlate the span-average film effectiveness data. The primary effect of wake unsteadiness was found to be correlated by a streamwise-constant decrement of 0.094.St. Steady computations were found to be in excellent agreement with experimental Nusselt numbers, but to overpredict experimental film effectiveness values. This is likely due to the inability to match actual hole exit velocity profiles and the absence of a credible turbulence model for film cooling.

Heidmann, James D.↗

Temperature-Dependent Magnetic Properties of Magnetorheological Elastomers

We report on an investigation of the temperature-dependent magnetic properties of magnetorheological elastomers (MREs). These are a class of composites that consist of magnetically permeable particles dispersed in a nonmagnetic polymeric matrix. Under the application of an external magnetic field, a large deformation occurs altering the mechanical properties of these materials. Due to their magnetoelastic coupling response, these materials are finding an increasing interest among the scientific community. These polymer-based composites’ performance depends on many factors, which temperature is one of the biggest influencing factors requiring further investigation. In this work, the magnetic properties of isotropic and anisotropic polyurethane-based MRE with different iron (Fe) particle loading fractions (50, 60, 70, and 80% by weight) were investigated under different temperatures. From the analysis, the magnetization curves of these materials are observed to overlap for the different measured temperature values. The variation of various magnetic properties including saturation magnetization and differential susceptibility with temperature was also determined. Furthermore, the results show ~ 2.5% decrement in the saturation magnetization for each of the loading fractions, between the lowest (300K) and the highest (400K) measured temperature. On the other hand, the initial differential susceptibility exhibits different trends with increasing temperature. Generally, the magnetization response of these materials is seen to be only slightly sensitive to temperature changes. Additionally, the magnetization response is observed to be highly dependent on particle loading fractions and particle orientation within the elastomer.

36 MATERIALS SCIENCE↗

Automation: Decision Aid or Decision Maker?

This study clarified that automation bias is something unique to automated decision making contexts, and is not the result of a general tendency toward complacency. By comparing performance on exactly the same events on the same tasks with and without an automated decision aid, we were able to determine that at least the omission error part of automation bias is due to the unique context created by having an automated decision aid, and is not a phenomena that would occur even if people were not in an automated context. However, this study also revealed that having an automated decision aid did lead to modestly improved performance across all non-error events. Participants in the non- automated condition responded with 83.68% accuracy, whereas participants in the automated condition responded with 88.67% accuracy, across all events. Automated decision aids clearly led to better overall performance when they were accurate. People performed almost exactly at the level of reliability as the automation (which across events was 88% reliable). However, also clear, is that the presence of less than 100% accurate automated decision aids creates a context in which new kinds of errors in decision making can occur. Participants in the non-automated condition responded with 97% accuracy on the six "error" events, whereas participants in the automated condition had only a 65% accuracy rate when confronted with those same six events. In short, the presence of an AMA can lead to vigilance decrements that can lead to errors in decision making.

Skitka, Linda J.↗

Designing Yield Grids for Airborne Nuclear Explosions to Maintain Decrements in Rayleigh Waveform Amplitudes

This document details a method for selecting grid points that sample the yields of airborne, low yield nuclear explosions that constrains the relative size of seismic waveforms sourced by explosions that are parameterized by this grid. In detail, we impose this constraint so that the vertical component of ground displacement that is sourced by explosions with a fixed height of burst (HoB) at grid point k change by a fixed factor of a when compared to the waveform amplitudes sourced by explosions at grid point k + 1, as observed at a fixed standoff distance. This gridding thereby preserves amplitude ratios along the grid so that they are agnostic to k. We assert that this method is useful in tests that apply algorithms against synthetic or augmented datasets for which the performance of the algorithm must be measured against source size, and waveform amplitudes must change uniformly (e.g., Berg et al, 2025).

58 GEOSCIENCES↗

Development of procedures for calculating stiffness and damping of elastomers in engineering applications. Part 5: Elastomer performance limits and the design and test of an elastomer damper

Tests were performed on elastomer specimens of the material polybutadiene to determine the performance limitations imposed by strain, temperature, and frequency. Three specimens were tested: a shear specimen, a compression specimen, and a second compression specimen in which thermocouples were embedded in the elastomer buttons. Stiffness and damping were determined from all tests, and internal temperatures were recorded for the instrumented compression specimen. Measured results are presented together with comparisons between predictions of a thermo-viscoelastic analysis and the measured results. Dampers of polybutadiene and Viton were designed, built, and tested. Vibration measurements were made and sensitivity of vibration to change in unbalance was also determined. Values for log decrement were extracted from the synchronous response curves. Comparisons were made between measured sensitivity to unbalance and log decrement and predicted values for these quantities.

Tecza, J. A.↗

Comparison of Cognitive Performance Tests for Promethazine Pharmacodynamics in Human Subjects

The objective of this study is to compare cognitive function tests, Automated Neurological Assessment Metrics (ANAM) based Readiness Evaluation System (ARES(Registered TradeMark)) on a Palm Pilot and Windows based Spaceflight Cognitive Assessment Tool (WinSCAT(Registered TradeMark)) on a personal computer (PC) to assess performance effects of promethazine (PMZ) after administration to human subjects. In a randomized placebo-controlled cross-over design, subjects received 12.5, 25, and 50 mg intramuscular (IM) PMZ or a placebo and completed 14 sessions with WinSCAT(Registered TradeMark) (v. 1.26) and ARES(Registered TradeMark) (v. 1.27) consecutively for 72 h post dose. Maximum plasma concentrations (4.25, 6.25 and 13.33 ng/ml) were linear with dose and were achieved by 0.75, 8, and 24 h after dosing for the three doses, respectively. No significant differences in cognitive function after PMZ dosing were detected using WinSCAT(Registered TradeMark), however, tests from ARES(Registered TradeMark) demonstrated concentration dependent decrements in reaction time associated with PMZ dose.

Vaksman, Z.↗

Adaptive Responses in Eye-Head-Hand Coordination Following Exposures to a Virtual Environment as a Possible Space Flight Analog

Virtual environments (VE) offer unique training opportunities, particularly for training astronauts and preadapting them to the novel sensory conditions of microgravity. Sensorimotor aftereffects of VEs are often quite similar to adaptive sensorimotor responses observed in astronauts during and/or following space flight. The purpose of this research was to compare disturbances in sensorimotor coordination produced by dome virtual environment display and to examine the effects of exposure duration, and repeated exposures to VR systems. The current study examined disturbances in eye-head-hand (EHH) and eye-head coordination. Preliminary results will be presented. Eleven subjects have participated in the study to date. One training session was completed in order to achieve stable performance on the EHH coordination and VE tasks. Three experimental sessions were performed each separated by one day. Subjects performed a navigation and pick and place task in a dome immersive display VE for 30 or 60 min. The subjects were asked to move objects from one set of 15 pedestals to the other set across a virtual square room through a random pathway as quickly and accurately as possible. EHH coordination was measured before, immediately after, and at 1 hr, 2 hr, 4 hr and 6 hr following exposure to VR. EHH coordination was measured as position errors and reaction time in a pointing task that included multiple horizontal and vertical LED targets. Repeated measures ANOVAs were used to analyze the data. In general, we observed significant increases in position errors for both horizontal and vertical targets. The largest decrements were observed immediately following exposure to VR and showed a fairly rapid recovery across test sessions, but not across days. Subjects generally showed faster RTs across days. Individuals recovered from the detrimental effects of exposure to the VE on position errors within 1-2 hours. The fact that subjects did not significantly improve across days suggests that in order to achieve dual adaptation of EHH coordination may require more than three training sessions. These findings provide some direction for developing training schedules for VE users that facilitate adaptation, support the idea that preflight training of astronauts may serve as useful countermeasure for the sensorimotor effects of space flight, and support the idea that VEs may serve as an analog for sensorimotor effects of spaceflight.

Harm, Deborah L.↗

Determining the Importance of In-Flight Treadmill Running Capabilities for Maintaining Astronaut Health and Performance

BACKGROUND: Physical deconditioning induced via spaceflight is most effectively attenuated through in-flight exercise training. Throughout its evolution, NASA has implemented advancements to in-flight exercise countermeasures, culminating in the triad of devices currently used aboard the International Space Station (ISS): a treadmill (T2), cycle ergometer (CEVIS), and resistance exercise device (ARED). Despite high-quality exercise devices and prescriptions, many crewmembers experience reductions in both aerobic capacity (VO2peak pre-post mean change: -10%) and strength (knee isokinetic pre-post mean change: -15%). As NASA moves towards exploration missions, which will impose greater size, power, and time constraints on exercise systems in addition to physically demanding surface extravehicular activities (EVAs), providing robust capabilities to protect crew health and performance should be prioritized. OVERVIEW: Future missions to the Lunar and Martian surfaces will include EVAs requiring ambulation and greater physical exertion than those in Apollo missions. While the exercise device concepts planned for exploration missions include resistive and aerobic capabilities, they do not allow for ambulation. Specifically, the countermeasure planned for Artemis Lunar transit is a flywheel device, which provides both exercise modalities through a single resistive cable. While more robust than the flywheel, the devices planned for the Lunar orbital space station, and subsequent Mars habitats, will provide distinct aerobic and resistance modalities capable of achieving high intensities. However, these modalities do not include a treadmill. Recent research suggests that greater in-flight running intensity and volume attenuate decrements in aerobic capacity and strength; however, this has not been experimentally confirmed. The Exploration Exercise Treadmill Requirements study is currently underway, aiming to determine the effects of exercising without a treadmill on aerobic capacity, strength, bone density, and sensorimotor function during long-duration spaceflight. DISCUSSION: Providing running capabilities on future exploration missions may help to maintain astronaut physical ability, reduce injury, and promote health. Studies quantifying the effects of using exploration exercise devices are in progress, which will help provide critical recommendations on whether a treadmill is a necessary component of the in-flight training regime. This presentation will discuss the capabilities of exploration exercise devices and the potential implications of not having running capabilities during long-duration spaceflight.

Alyssa N Varanoske↗

A Centralized Display for Mission Monitoring

Humans traditionally experience a vigilance decrement over extended periods of time on reliable systems. One possible solution to aiding operators in monitoring is to use polar-star displays that will show deviations from normal in a more salient manner. The primary objectives of this experiment were to determine if polar-star displays aid in monitoring and preliminary diagnosis of the aircraft state. This experiment indicated that the polar-star display does indeed aid operators in detecting and diagnosing system events. Subjects were able to notice system events earlier and they subjectively reported the polar-star display helped them in monitoring, noticing an event, and diagnosing an event. Therefore, these results indicate that the polar-star display used for monitoring and preliminary diagnosis improves performance in these areas for system related events.

Trujillo, Anna C.↗

Comparison of theoretical and experimental thrust performance of a 1030:1 area ratio rocket nozzle at a chamber pressure of 2413 kN/m2 (350 psia)

The joint Army. Navy, NASA. Air Force (JANNAF) rocket engine peformnace prediction procedure is based on the use of various reference computer programs. One of the reference programs for nozzle analysis is the Two-Dimensional Kinetics (TDK) Program. The purpose of this report is to calibrate the JANNAF procedure incorporated into the December l984 version of the TDK program for the high-area-ratio rocket engine regime. The calibration was accomplished by modeling the performance of a 1030:1 rocket nozzle tested at NASA Lewis Research Center. A detailed description of the experimental test conditions and TDK input parameters is given. The results show that the computer code predicts delivered vacuum specific impulse to within 0.12 to 1.9 percent of the experimental data. Vacuum thrust coefficient predictions were within + or - 1.3 percent of experimental results. Predictions of wall static pressure were within approximately + or - 5 percent of the measured values. An experimental value for inviscid thrust was obtained for the nozzle extension between area ratios of 427.5 and 1030 by using an integration of the measured wall static pressures. Subtracting the measured thrust gain produced by the nozzle between area ratios of 427.5 and 1030 from the inviscid thrust gain yielded experimental drag decrements of 10.85 and 27.00 N (2.44 and 6.07 lb) for mixture ratios of 3.04 and 4.29, respectively. These values correspond to 0.45 and 1.11 percent of the total vacuum thrust. At a mixture ratio of 4.29, the TDK predicted drag decrement was 16.59 N (3.73 lb), or 0.71 percent of the predicted total vacuum thrust.

Smith, Tamara A.↗

Atg12 Maintains Skeletal Integrity by Modulating Pro-Osteoclastogenic Signals and Chondrocyte Differentiation

Weightlessness and radiation, two unique elements of space, profoundly decreases bone mass. This bone loss is attributed to increased activity of bone-resorbing osteoclasts and functional changes in bone-forming osteoblasts, cells that give rise to mature osteocytes. Our long-term goal is to identify signaling pathways that may be targeted to mitigate bone loss in scenarios of space exploration, radiotherapy and accidental radiation exposure. We have previously shown that exposure of MLO-Y4 osteocyte-like cells to simulated space radiation (56Fe) increased the expression of the pro-osteoclastogenic gene rankl and decreased protein levels of LC3B-II, a key player in autophagy. In this current study, we aimed to further elucidate the role of autophagy in maintaining structural integrity of the skeleton. We hypothesize that loss of autophagy in bone leads to an imbalance in pro-osteoclastogenic and pro-osteogenic signals, resulting in net bone loss. To test our hypothesis we performed global postnatal deletion of Atg12 using tamoxifeninducible Cre recombinase under the control of the CAG promoter. Six-week-old CAGCreERT2/ FloxAtg12 animals were treated daily with Tamoxifen or Vehicle (Control, oil only) for five days and euthanasia performed two weeks after the onset of treatment. Percent change in body weights (prior to treatment and at euthanasia) was not significantly different between treatment groups within the same gender. Compared to Vehicle (Control) groups, Tamoxifen (Atg12 iKO) groups showed decreased LC3B-I to II conversion and increased p62 protein levels, consistent with loss of autophagy. Quantitative PCR revealed increased expression of proosteoclastogenic cytokines mcp1 and rankl in bone and marrow respectively in male iKOs compared to male controls. Expression levels of these genes were not significantly altered in the Atg12 iKO females compared to females controls. Microcomputed tomography of tibiae revealed decreased cortical bone volume, cortical thickness and periosteal perimeter consistent with bone loss; and a longer primary spongiosa in male Atg12 iKOs display compared to male controls. These decrements were less pronounced in the female Atg12 iKOs. Cancellous bone structure was not significantly different between iKOs and controls in both genders. Histological analysis also revealed that compared to male controls, male iKOs showed a profound increase in chondrocyte column length of the growth plate with hyper-expansion of both proliferating and hypertrophic zones. Taken together, these findings indicate that autophagy plays an important role in the maintenance of bone structural integrity by mediating the production of proosteoclastogenic signals and regulating chondrocyte proliferation and differentiation.

autophagy↗

Development of a Rover Simulation to Assess Operational Proficiency Following Long Duration Spaceflights

Following long-duration space transits, adaptive changes in sensorimotor and cognitive function may impair the crew s ability to safely control pressurized rovers designed to explore the new environment. We describe a rover simulation developed to quantify post-flight decrements in operational proficiency following International Space Station expeditions. The rover simulation consists of a serial presentation of discrete tasks to be completed as quickly and accurately as possible. Each task consists of 1) perspective taking using a map that defines a docking target, 2) navigation toward the target around a Martian outpost, and 3) docking a side hatch of the rover to a visually guided target. The simulator utilizes a Stewart-type motion base (CKAS, Australia), single seat cabin with triple scene projection covering approximately 150 horizontal by 40 vertical, and joystick controller. The software was implemented using Unity3 with next-gen PhysX engine to tightly synchronize simulation and motion platform commands. Separate C# applications allow investigators to customize session sequences with different lighting and gravitational conditions, and then execute tasks to be performed as well as record performance data. Preliminary tests resulted in low incidence of motion sickness (<15% unable to complete first session), with only negligible after effects and symptoms after familiarization sessions. Functionally relevant testing early post-flight will develop evidence regarding the limitations to early surface operations and what countermeasures are needed. This approach can be easily adapted to other vehicle designs to provide a platform to safely assess how sensorimotor and cognitive function impact manual control performance.

DeDios, Y. E.↗

Influence of Vibrotactile Feedback on Controlling Tilt Motion After Spaceflight

We hypothesize that adaptive changes in how inertial cues from the vestibular system are integrated with other sensory information leads to perceptual disturbances and impaired manual control following transitions between gravity environments. The primary goals of this ongoing post-flight investigation are to quantify decrements in manual control of tilt motion following short-duration spaceflight and to evaluate vibrotactile feedback of tilt as a sensorimotor countermeasure. METHODS. Data is currently being collected on 9 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s, <20 cm radius) in a darkened room is utilized to elicit otolith reflexes in the lateral plane without concordant canal or visual cues. A Tilt-Translation Sled (TTS) is capable of synchronizing pitch tilt with fore-aft translation to align the resultant gravitoinertial vector with the longitudinal body axis, thereby eliciting canal reflexes without concordant otolith or visual cues. A simple 4 tactor system was implemented to provide feedback when tilt position exceeded predetermined levels in either device. Closed-loop nulling tasks are performed during random tilt steps or sum-of-sines (TTS only) with and without vibrotactile feedback of chair position. RESULTS. On landing day the manual control performance without vibrotactile feedback was reduced by >30% based on the gain or the amount of tilt disturbance successfully nulled. Manual control performance tended to return to baseline levels within 1-2 days following landing. Root-mean-square position error and tilt velocity were significantly reduced with vibrotactile feedback. CONCLUSIONS. These preliminary results are consistent with our hypothesis that adaptive changes in vestibular processing corresponds to reduced manual control performance following G-transitions. A simple vibrotactile prosthesis improves the ability to null out tilt motion within a limited range of motion disturbances.