Search NASASearch

SEARCH · Search NASA

Results for “PERFORMANCE TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,426 records · Page 18

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang

Battery testing device

A battery testing device is described for testing the cells of a multiple-cell battery, the battery having a cover plate with access holes to provide access to the connecting straps between cells. A panel of probe assembly receiving holes is located to correspond to the location of the access holes when the panel is positioned on top of the battery. A probe assembly is positioned within each probe assembly receiving hole, with a spring biased electrically conductive plunger to make electrical contact with the connecting strap through the corresponding access hole when the panel is pushed towards the top of the battery.

Boshers, W. A.

Methods and recommendations for large-scale deflagration testing of battery energy storage system enclosures

UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.

Gaudet, Benjamin [UL Solutions] (ORCID:00090006419

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Thermostructural Testing of PICA-D for NASA Planetary Science Missions

Phenolic Impregnated Carbon Ablator–Domestic (PICA‑D) has been selected as the heatshield thermal protection system (TPS) material for two upcoming NASA planetary science missions: the Dragonfly mission to Titan and the Mars Sample Retrieval Lander (SRL). Early testing revealed differences between PICA‑D and heritage PICA, particularly in in‑plane (IP) tensile stiffness and thermal expansion. Thermostructural analyses using Finite Element Method (FEM) tools subsequently predicted the potential for IP compressive failure in the near‑surface layers of PICA‑D under both Dragonfly and SRL flight environments. Over the past three years, the Dragonfly and SRL teams have carried out an extensive thermostructural qualification campaign to address these concerns and validate PICA‑D for flight. This effort began with a comprehensive mechanical property characterization program at Kratos test laboratories, which significantly improved understanding of PICA‑D mechanical behavior and increased the fidelity of FEM predictions. The teams also conducted six large‑scale test entries at the National Solar Thermal Test Facility (NSTTF) solar tower, exposing PICA‑D articles—including gap fillers and representative design features or flaws—to combined thermal and mechanical loads. The talk will summarize key findings from these mechanical and thermostructural test campaigns and present the current status of PICA‑D qualification for NASA’s planetary science missions.

TPS

Charge retention test experiences on Hubble Space Telescope nickel-hydrogen battery cells

The Hubble Space Telescope (HST) nickel-hydrogen battery module was designed by Lockheed Missile & Space Co (LMSC) and manufactured by Eagle-Picher Ind. (EPI) for the Marshall Space Flight Center (MSFC) as an Orbital Replacement Unit (ORU) for the nickel-cadmium batteries originally selected for this low earth orbit mission. The design features of the HST nickel hydrogen battery are described and the results of an extended charge retention test are summarized.

Nawrocki, Dave E.

Advanced Materials Testing Plan for the Space Suit Portable Life Support System

The Space Suit Portable Life Support System (PLSS) has a tight mass requirement to meet while also meeting other requirements for supporting a crewmember in space, on the Moon, or on Mars. To meet these requirements, atypical materials must be considered to close the mass budget allocations. However, many of these materials and processes are relatively new and untested. Therefore, initial analysis and testing of some new and advanced processes have been conducted following a roadmap presented last year. This material testing has focused primarily on thermoplastics, both additively manufactured and machined, to assess plating and fastening operations that will be required. These processes will provide additional strength and shielding capability typically only achieved with metallics. This testing has also helped to define a forward plan to certify these materials and processes for critical spaceflight applications. This report will review testing plated thermoplastics both for strength and thermal properties. It will also review fastener and fastening options and look at insert and fastener testing. It will also review state-of-the-art methods being considered elsewhere and some additional testing being conducted. Using the testing results researched here, there will be recommendations on applications for each of these types of methods going forward.

Ryan Ogilvie

Advanced Materials Testing Plan for the Space Suit Portable Life Support System

The Space Suit Portable Life Support System (PLSS) has a tight mass requirement to meet while also meeting other requirements for supporting a crewmember in space, on the Moon, or on Mars. To meet these requirements, atypical materials must be considered to close the mass budget allocations. However, many of these materials and processes are relatively new and untested. Therefore, initial analysis and testing of some new and advanced processes have been conducted following a roadmap presented last year. This material testing has focused primarily on thermoplastics, both additively manufactured and machined, to assess plating and fastening operations that will be required. These processes will provide additional strength and shielding capability typically only achieved with metallics. This testing has also helped to define a forward plan to certify these materials and processes for critical spaceflight applications. This report will review testing plated thermoplastics both for strength and thermal properties. It will also review fastener and fastening options and look at insert and fastener testing. It will also review state-of-the-art methods being considered elsewhere and some additional testing being conducted. Using the testing results researched here, there will be recommendations on applications for each of these types of methods going forward.

Ryan Ogilvie

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series are: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and to develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

Ben Swartout

Engineering the Interface: Advanced Surface Technologies for Lunar Dust Management and Equipment Longevity

Through the Artemis program, NASA intends to develop a sustainable human foothold on the Moon, ultimately paving the way for crewed exploration of Mars. The Moon's hostile environment poses numerous obstacles, including exposure to radiation, temperature extremes, micrometeoroid threats, and particularly the persistent problem of lunar dust. Lunar dust impacts nearly every aspect of surface operations through adhesion and abrasion mechanisms, with contamination from anthropogenic activities (landing, rovers) far outweighing natural phenomena. Multiple adhesion pathways contribute to surface contamination in the lunar environment, including van der Waals forces, electrostatic forces, chemical reaction, and magnetic forces from elemental iron deposits. Sharp asperities from micrometeoroid bombardment and atmospheric absence increase interaction potential and enable mechanical interlocking. Low cohesion between dust particles exacerbates these challenges, as minimal interaction potential between dust and nearby surfaces overcomes particle cohesion, causing contamination. Lunar dust adhesion mitigation technologies can be categorized as either active, requiring external energy, or passive, relying on intrinsic material properties. Ultrasonic and electrodynamic technologies have been developed to the highest technology readiness level for active approaches. Passive strategies primarily focus on surface chemistry and topography modifications. At NASA Langley Research Center, approaches include surface migration agents to reduce surface energy, topographical modification using laser ablation patterning, and tailored surface conductivity to reduce intrinsic adhesion force. Performance has been evaluated using custom-built ultrasonic and centrifuge instruments. Plume-surface interactions from lunar landers can propel micrometer-sized particles at velocities up to 1000 m s-1.8 These particles pose risks to landers, habitats and infrastructure, leading to erosion, degradation, and reduced component lifespan. A panel recovered from Surveyor III was determined to have been severely abraded because of lunar dust displaced from the Apollo 12 lunar module that landed 160 m away. The performance of metallic surfaces has been evaluated via high velocity single particle impact using the laser-induced project impact test (LIPIT) facility at the University of Utah. Peridynamics modeling, a form of continuum mechanics that uses a nonlocal approach enabling greater simulation capabilities of crack initiation and fracture, has also been utilized to gain greater insight into material response during impact events. Lunar dust contamination challenges extend to power generation systems and moving equipment. Cables, rotation stages, and other mechanisms may experience limited range of motion and reduced lifetime due to dust infiltration. NASA Langley Research Center has evaluated traditional aerospace alloys, softgoods, wear resistant ceramics, and several polymer and polymer composite materials. Test methods have included traditional techniques like Taber abrasion testing, as well as designed test configurations developed in the DUSTE (dust, ultraviolet radiation, and space thermal environmental) chamber that reproduce mechanism functions in operational environment. Beyond laboratory experiments, several flight experiments have been conducted. Materials were exposed to the low Earth orbit environment on the Materials International Space Station Experiment (MISSE) and to the lunar surface environment through the Aegis Aerospace Regolith Adherence Characterization (RAC) payload and the Honeybee Robotics PlanetVac payload. Determining lunar dust's impact on surface exploration and habitation requires comprehensive experimental and computational capabilities combined with lessons learned from initial lunar activities. Identifying the greatest environmental challenges and developing mitigation technologies provides the clearest path toward successfully, expeditiously, and efficaciously completing NASA's mission. This presentation will discuss ongoing efforts at NASA Langley Research Center and collaborator contributions to these critical objectives.

Surface Engineering

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series were: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

TVAC

Mechanical Design and Operation of a Novel Lunar Environment Structural Test Rig (LESTR)

The Lunar Environment Structural Test Rig (LESTR) was developed to address a critical gap in mechanical property data for metal alloy wire materials under lunar-relevant conditions down to 40 K. Conventional aerospace material databases provide thermophysical properties for bulk metals over a wide temperature range, but validated mechanical and physical property data below 77 K, particularly for small-diameter wires, remain limited and are generally the exception rather than the rule. These conditions are essential for Artemis mission hardware such as shape memory alloy (SMA) rover tires. LESTR’s design requirements were to combine a high-stiffness electrodynamic load frame with closed- cycle cryogenic cooling, high-vacuum capability (10–6 torr), and noncontact optical strain measurement to enable tensile, four-point bend, and fatigue testing of wires or other materials and geometries at temperatures from 40 to 125 K. These considerable requirements were merged with the need to lower the barrier of testing for the end user as measured in terms of cost-per-test cycle, safety improvement, and reduction in upkeep costs associated with state-of-the-art solutions associated with cryomechanical material characterization. The system incorporates modular gripping and alignment fixtures; precision thermal management using cryocoolers and embedded heaters; and integrated instrumentation for displacement, load, temperature, and vacuum control. Calibration procedures establish correlations between tooling and specimen temperature, ensuring accurate thermal conditions across the design envelope unbound by cryofluid conditions in heritage immersion-based test systems. Initial validation tests using Inconel (Special Metals Corp.) wire demonstrated accurate ultimate strength and post-yield behavior. The load frame operation was also verified under representative service conditions, including thermal cycling and prolonged fatigue loading. By generating mechanical property data at ultralow temperatures, LESTR fills a critical gap in existing materials databases and provides a scalable platform for iterative alloy development and durability assessment for planetary hardware. This capability supports NASA’s long-term objectives for surface exploration by enabling design confidence for components operating in extreme cryogenic environments.

LESTR

Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell

Li-ion EMU Battery Testing

A 45Ah Lithium ion (Li-Ion) battery comprised of 5 Yardney prismatic cells was evaluated to replace the silver-zinc cells in the Extra-vehicular Mobility Unit (EMU). Tests determined that the five cell battery can meet the mission objective of 500 duty cycles and maintain a minimum voltage of 16.0 V without an individual cell voltage dropping below 3.0V. Forty real time cycles were conducted to develop BOL trend data. Decision to switch to accelerated cycling for the remaining 460 cycles was made since Real Time cycling requires 1 day/cycle. Conclusions indicate that battery replacement would indeed be prudent.

Rehm, Raymond

Apollo-Soyuz Test Project: Preliminary Science Report

This document summarizes the experimental concepts and preliminary analyses (as of December 1975) for each of the 28 scientific experiments conducted during the Apollo-Soyuz Test Project from July 15 to 24, 1975. The scientific topics are X- ray and extreme ultraviolet astronomy, solar astronomy, gamma- ray detectors, Earth studies (including the upper atmosphere, meteorological phenomena, hydrology, oceanography, geology, desert studies, and gravity field studies), microbiology, heavy cosmic particle interaction with live cells, vestibular system studies, and materials processing (including high-temperature and ambient-temperature processing of industrial materials and electrophoretic processing of biological materials) .

Microbiology

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI