Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Additive Manufacturing and Experimental Characterization of Nickel-Titanium Shape-Memory Alloy Wick Structures and Heat Pipes for Spacecraft Thermal Control

Shape memory alloys (SMA), such as those based on nickel-titanium (NiTi), are increasingly being applied as multifunctional spacecraft components. For thermal management applications, NiTi flow tubing hinges and self-deploying loop heat pipes have been demonstrated. Emerging additive manufacturing (AM) processes are enabling more complex SMA devices than can be formed from conventional plain wire, tubing, and sheet stock materials. This paper presents our progress toward applying powder bed fusion AM to producing porous NiTi wicks and NiTi-H2O heat pipes, which could be embedded in thermally deploying radiators for spacecraft thermal management. AM near-equiatomic NiTi (55.1 wt% Ni) porous wick specimens were produced with a range of deposition parameters. Transient acetone rate-of-rise experiments were performed to estimate wick permeability (K) and average pore radius (r_pore) values and identify parameter sets with high capillary performance. Surface treatments were evaluated to achieve hydrophilic wick structures. Evaluated treatments included chemical oxide growth with H2O2, oxide and sodium titanate growth with NaOH solution, and ultrasonic cleaning with specialty detergents that can remove hydrocarbon contaminants. The most durable hydrophilic surface conditions were obtained with the NaOH treatment. High performing wick deposition parameters were used to produce a full AM NiTi heat pipe, which was treated with NaOH solution to activate the wick. This heat pipe was operated on a test stand in the inverted configuration (upper evaporator and lower condenser), and demonstrated stable nearly isothermal operation for 150 hrs.

Thermal management↗

[Presentation Slides] Code-to-Code Benchmark Study for Thermal Stress Modeling and Preliminary Analysis of the High-temperature Single Heat-Pipe Experiment

In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios. This presentation slides discuss finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL), using two commercial software packages, Abaqus and Star-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain preliminary insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the inner surface of the heat pipe hole surrounded by electric heaters where the largest temperature gradients appear. The temperature fields have good agreements between Abaqus and Star-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes. It is found that the local maximum thermal stresses may reach close to the ultimate tensile strength and yield strength of structural material depending on the heater power. Ultimately, the coupled thermal-structural analysis will help guide the current experimental plan and ensure the facility safety for future experimental study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigations of Advanced Measurement Methods for High-Temperature Heat-Pipe Experiments

Various types of microreactor designs are under consideration, and among those, the heat-pipe cooled reactor designs are currently being actively investigated at Idaho National Laboratory (INL). In order to support non-nuclear testing and demonstration of technology under the Department of Energy (DOE) Microreactor Program (MRP), Single Primary Heat Extraction and Removal Emulator (SPHERE) was designed and constructed to perform high-temperature heat pipe (HP) experiments at INL. Based on the SPHERE experimental setup, this summary paper conducts the preliminary investigations among the available literature and summarizes some potential advanced measurement techniques for operando high-temperature heat pipe which can be implemented to support MRP. The primary objective for the extensive literature research is to investigate the possibilities and feasibilities for designing and construct an advanced experimental test facility with the aim of producing high-fidelity high-resolution heat pipe data during its operations.

42 ENGINEERING↗

AN INITIAL LOOK AT THE HEAT PIPE RESILIENCY TO REACTOR OPERATION

Several special purpose reactor designs are aiming to utilize heat pipes due to its inherently passive features allowing safe heat removal to the power conversion systems. There is insufficient data on heat pipe survivability in reactor environments, although heat-pipe failures are predicted to have low failure rates. In this paper, we perform a coupled neutronics and thermo-mechanics analyses for a 45 kWth HALEU fueled, hydride moderated homogenous design to evaluate the transient effects during both startup and a heatpipe-failure scenario. The heatpipe-failure study includes both a single failure case and a failure-propagation (cascading) case. While the model only evaluates a homogenous core, the approach could be applied to more complex models for any heat pipe cooled small reactor.

99 GENERAL AND MISCELLANEOUS↗

Modeling Heat Pipes with Non-Condensable Gases

The report showcases advancements in modeling heat pipes, considering both scenarios with and without non-condensable gases. To achieve this, two distinct modeling approaches are juxtaposed. Firstly, the effective conduction model, implemented in the MOOSE-based code Sockeye, is employed. Secondly, a first-of-a-kind two-phase Euler-Euler Computational Fluid Dynamics (CFD) model is developed using the STAR-CCM+ code. Both models undergo validation against experimental data, acknowledging the inherent uncertainties associated with each modeling assumption. Interestingly, the non-tuned CFD model surpasses the performance of the calibrated conduction model for heat pipes operating under both conditions: with and without non-condensable gases. It's worth noting, however, that the CFD models entail significantly longer runtimes compared to the conduction models. Nevertheless, the insights garnered from the CFD model shed invaluable light on the intricate operational dynamics of heat pipes. Future work involves broadening the validation scope of these models and continuing their development to enhance their utility as robust tools for heat pipe design and operational support.

42 ENGINEERING↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

Development of a conduction-based model for analyzing frozen startup of alkali-metal heat pipes

One key area of interest in heat pipe modeling/simulation is to analyze the startup behavior of the liquid-metal heat pipes (LMHPs) from a frozen state. This so-called ‘frozen startup’ process involves a complex set of nonlinear mass and heat transport phenomena, including phase transitions from solid to liquid and vapor, multiphase interactions, microporous wick flow, and compressible vapor dynamics. The complexity of these processes makes it challenging to simulate LMHP’s frozen startup using conventional numerical methods or commercial computational fluid dynamics (CFD) software. This paper presents a simplified conduction-based modeling approach that can provide practical insights into the entire LMHP frozen startup process, while alleviating the challenges of modeling its complex physics. The theoretical foundation and physical assumptions of the proposed model are based solely on heat-conduction equation, allowing for a more tractable simulation without sacrificing essential physical accuracy. The proposed model was implemented in a commercial CFD software, and its prediction was compared with the experimental data obtained from sodium heat-pipe startup experiments. The comparison highlights the proposed model's ability to capture the transient thermal behavior of LMHP during frozen startup. This study not only validates the conduction-based frozen startup modeling method but also shows its potential as a practical and efficient tool for understanding the startup performance of the LMHP systems.

Microreactor↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Study on the residual stress relaxation in girth-welded steel pipes under bending load using diffraction methods

This research is dedicated to the experimental investigation of the residual stress relaxation in girth-welded pipes due to quasi-static bending loads. Ferritic-pearlitic steel pipes are welded with two passes, resulting in a characteristic residual stress state with high tensile residual stresses at the weld root. Also, four-point bending is applied to generate axial load stress causing changes in the residual stress state. These are determined both on the outer and inner surfaces of the pipes, as well as in the pipe wall, using X-ray and neutron diffraction. Focusing on the effect of tensile load stress, it is revealed that not only the tensile residual stresses are reduced due to exceeding the yield stress, but also the compressive residual stresses for equilibrium reasons. Furthermore, residual stress relaxation occurs both parallel and perpendicular to the applied load stress.

36 MATERIALS SCIENCE↗

Gaseous flow through heterogeneous, partially connected networks of pipes

Simulations of flow of an ideal gas through heterogeneous simple cubic pipe networks with different pipe radius distributions and variable bond coordination numbers were performed. Networks with monomodal and bimodal radius distributions were constructed. A very wide range of Knudsen numbers was achieved. Flow simulations of purely viscous gases and incompressible liquids were also carried out for comparison. The permeability to gas in the purely viscous regime was larger than the permeability to an incompressible liquid. Based on a variety of computational tests, this result was likely not a numerical artifact. The simulated macroscopic flow behavior differed from the underlying single pipe model, depending on the radius distribution, network connectivity and magnitude of the externally applied pressure gradient, and was compatible with the Klinkenberg analysis only when the maximum Knudsen number used in each simulation was lower than 1. In this condition, the Klinkenberg coefficient was nearly proportional to the inverse of the network hydraulic radius while the effect of the radius distribution was weak and that of the network connectivity essentially negligible. Here, the bimodal simulations displayed a typical percolation behavior, with the Klinkenberg coefficient remaining constant as long as the large pipe population was connected.

42 ENGINEERING↗

Ultrasonic multi-skip tomography for pipe inspection

The inspection of wall loss corrosion is difficult at pipe supports due to limited accessibility. The recently developed ultrasonic Multi-Skip screening technique is suitable for this problem. The method employs ultrasonic transducers in a pitch-catch geometry positioned on opposite sides of the pipe support. Shear waves are transmitted in the axial direction within the pipe wall, reflecting multiple times between the inner and outer surfaces before reaching the receivers. Along this path, the signals accumulate information on the integral wall thickness (e.g., via variations in travel time). The method is very sensitive in detecting the presence of wall loss, but it is difficult to quantify both the extent and depth of the loss. Multi-skip tomography has been developed to reconstruct the wall thickness profile along the axial direction of the pipe. The method uses model-based full wave field inversion; this consists of a forward model for predicting the measured wave field and an iterative process that compares the predicted and measured wave fields and minimizes the differences with respect to the model parameters (i.e., the wall thickness profile). Experimental results are very encouraging. Various defects (slot and flat bottom hole) are reconstructed using the tomographic inversion. The general shape and width are well recovered. The current sizing accuracy is in the order of 1 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing Intermittent Water Supply in Urban Pipe Distribution Networks

In many urban areas of the developing world, piped water is supplied only intermittently, as valves direct water to different parts of the water distribution system at different times. The flow is transient, and may transition between free-surface and pressurized, resulting in complex dynamical features with important consequences for water suppliers and users. Here, we develop a computational model of transition, transient pipe flow in a network, accounting for a wide variety of realistic boundary conditions. We validate the model against several published data sets and demonstrate its use on a real pipe network. The model is extended to consider several optimization problems motivated by realistic scenarios. Here, we demonstrate how to infer water flow in a small pipe network from a single pressure sensor, and show how to control water inflow to minimize damaging pressure transients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Models to Predict the Hygrothermal Performance of Equipment and Piping Insulation

The development of hygrothermal models began in earnest in the 1990s, with the initial emphasis on the performance of building envelope systems. Numerous large-scale building envelope failures associated with water intrusion drove this development. The physical principles of moisture transfer that apply to building envelopes are equally valid for equipment and piping insulation systems. The main advantage of modeling is that carefully characterized models can predict the long-term hygrothermal performance of any system under different climatic and interior conditions. Thermal insulations are commonly used on outdoor equipment and piping for different applications, such as thermal energy conservation and freeze protection. The insulated equipment usually experiences moisture intrusion due to many factors, such as the duration and frequency of moisture exposure, equipment operating temperature, insulation type, exposure temperature, weather conditions, equipment thermal cycling, and weatherproofing condition. Hygrothermal models have been employed to estimate the moisture pickup of insulated equipment and piping systems, as well as the moisture redistribution and subsequent change in thermal performance as these systems become contaminated with moisture. The hygrothermal model provides insights on the parameters influencing the time of wetness, the lateral redistribution of moisture along the pipe away from the leak, and the ease by which water escapes the insulation/jacketing systems. It has been shown that the moisture leak effect decreases rapidly with distance from the leak and that one- and two-dimensional hygrothermal simulations help to identify solutions to reduce conditions that support corrosion under insulation (CUI).

Shrestha, Som↗

Demonstration and Feasibility Analyses of using the Dual-Purpose Canister Drain Pipe to Support the Filling Process

This report documents experiments that are being used to determine the feasibility of filling dual-purpose canisters (DPCs) using the existing drain pipe. Mercury was identified as a surrogate filler for the initial experiments. Oak Ridge National Laboratory’s Target Test Facility (TTF), which is a full-scale Spallation Neutron Source (SNS) prototypical mercury loop, is being used for the planned pipe experiments using mercury. The pipe experiments were divided into two phases to provide a separate effects approach to the problem and to allow for development of system scalability. The first phase included taking strain measurements in a short length pipe, as well as measurements of flow-induced vibration. The second phase consists of the design and construction of a separated mercury flow loop capable of hosting exchangeable test sections and more localized instrumentation. Data acquisition of Phase I was performed during this reporting time period, and subsequent data reduction and data analysis will be performed in the future.

36 MATERIALS SCIENCE↗

Calculation of Friction Factors in Heat Pipes Using CFD in Support of the Sockeye Code

A heat pipe is two-phase heat transfer device which relies on surface tension and capillary pressure to provide a very efficient heat transfer mechanism. Currently, there is interest in designing micro nuclear power reactors using high temperature heat pipes to provide totally passive cooling. To support this, Sockeye is being developed as a heat pipe simulation capability. To support the development of Sockeye, individual phenomena must be tested. This work focuses on applying a CFD model to evaluate friction factors for use in Sockeye. A CFD model has been developed in Nek5000 which simulates each component fluid, i.e. sodium liquid and vapor, independently and captures the effects of the wick on friction factor. The model tests the effect of the wick permeability and the thickness of the wick occupied by each fluid component. The thickness of the wick occupied by each component can be directly related to the local vapor volume fraction from the Sockeye heat pipe model. Results from the CFD model indicate that friction factor in the liquid flow decreases with increasing wick permeability, while the friction factor in the vapor flow increases with increasing wick permeability. In the liquid, this is likely a direct result of the increased cross sectional area available for the flow. For the vapor, this is explained as the wick acting like a rough wall, while the increased area has only a negligible impact. Results for the tests of the thickness of the wick occupied by each fluid showed a thresholding behavior for both liquid and vapor. When the thickness of the wick occupied by each fluid was increased, it increased the effect of the wick, but only up to a certain point. Once a certain thickness was reached, the friction factors remained constant. When the fluid occupied only a very small fraction of the wick, friction factors returned to nominal values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Debonding Effect in Internal Replacement Pipe System Under Lateral Loading

The aging pipeline infrastructure around the world necessitates immediate rehabilitation. Internal replacement pipe (IRP) is a trenchless system offering a versatile and cost-effective solution across a variety of industries, including oil, natural gas, water, and wastewater. As a structural pipeline repair system, IRPs are subject to lateral deformation because of surface traffic loading. The present study evaluates the impact of adhesion between the host pipe and the IRP, with a focus on assessing the debonding effect on the behavior of the repair system under lateral deformation and bending. This was achieved using a comprehensive approach, including experimental, numerical, and analytical techniques. Varying levels of adhesive strength resulting from different methods of surface preparation were considered. The effectiveness of the IRP system on both discontinuous host pipes with various crack widths and continuous host pipes was also investigated. The results demonstrate that adhesive strength exerts a significant influence on the repair system, especially in the case of narrow circumferential cracks, while its impact on the continuous system is minimal. For optimal performance, it is essential to choose adhesives that possess sufficient shear strength while also accounting for the required debonding length. This approach ensures that minor discontinuities are effectively controlled, thereby enhancing the system′s fatigue life. The reliable determination of the maximum allowable shear strength for the adhesive or the debonding length can ensure that it does not negatively affect fatigue life. The findings presented in this study offer new insights into the development of trenchless repair techniques that can enhance system performance and extend service life.

Tien, Tri C. M.↗

Studies reveal effects of pipe bends on fluid flow cavitation

Incipient cavitation in liquids flowing in pipes curved in one plane are affected by the pipe bend radii and pipe diameters, but little by pipe bend angles ranging from 60 to 120 degrees. Critical cavitation indices decrease with higher Reynolds number and pressure ratio. Bulk liquid temperature increase lowers the mean critical velocity at which cavitation occurs.

Stonemetz, R. E.↗