Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLATELET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

HEMODOSE: A Set of Multi-parameter Biodosimetry Tools

After the events of September 11, 2001 and recent events at the Fukushima reactors in Japan, there is an increasing concern of the occurrence of nuclear and radiological terrorism or accidents that may result in large casualty in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine the radiation induced changes at different biological levels. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced injury. This is due to the fact that hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as the most practical and best laboratory test to estimate radiation dose. The HEMODOSE web tools are built upon solid physiological and pathophysiological understanding of mammalian hematopoietic systems, and rigorous coarse-grained biomathematical modeling and validation. Using single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure, these tools can estimate absorbed doses of adult victims very rapidly and accurately. Some patient data in historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large scale radiological disaster scenario. Unlike previous dose prediction algorithms, the HEMODOSE web tools establish robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in very late phase (up to 4 weeks) after exposure

Hu, Shaowen↗

HEMODOSE: A Set of Multi-parameter Biodosimetry Tools

There continues to be important concerns of the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow (BM) injury. This is due to the fact that hematopoietic system is a vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. In this work we describe the HEMODOSE web tools, which are built upon solid physiological and pathophysiological understanding of mammalian hematopoietic systems, and rigorous coarse-grained biomathematical modeling and validation. Using single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure, these tools can estimate absorbed doses of adult victims very rapidly and accurately to assess the severity of BM radiation injury. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. HEMODOSE web tools establish robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in very late phase (up to 4 weeks) after exposure.

Hu, Shaowen↗

Absorption Efficiencies of Forsterite. I: DDA Explorations in Grain Shape and Size

We compute the absorption efficiency (Q(sub abs)) of forsterite using the discrete dipole approximation (DDA) in order to identify and describe what characteristics of crystal grain shape and size are important to the shape, peak location, and relative strength of spectral features in the 8 - 40 micron wavelength range. Using the DDSCAT code, we compute Q(sub abs) for non-spherical polyhedral grain shapes with a(sub eff) = 0.1 micron. The shape characteristics identified are: 1) elongation/reduction along one of three crystallographic axes; 2) asymmetry, such that all three crystallographic axes are of different lengths; and 3) the presence of crystalline faces that are not parallel to a specific crystallographic axis, e.g., non-rectangular prisms and (di)pyramids. Elongation/reduction dominates the locations and shapes of spectral features near 10, 11, 16, 23.5, 27, and 33.5 micron, while asymmetry and tips are secondary shape effects. Increasing grain sizes (0.1 - 1.0 micron) shifts the 10, 11 micron features systematically towards longer wavelengths and relative to the 11 micron feature increases the strengths and slightly broadens the longer wavelength features. Seven spectral shape classes are established for crystallographic a-, b-, and c-axes and include columnar and platelet shapes plus non-elongated or equant grain shapes. The spectral shape classes and the effects of grain size have practical application in identifying or excluding columnar, platelet or equant forsterite grain shapes in astrophysical environs. Identification of the shape characteristics of forsterite from 8 - 40 micron spectra provides a potential means to probe the temperatures at which forsterite formed.

circumstellar matter↗

A Multiple Parameters Biodosimetry Tool with Various Blood Cell Counts - the Hemodose Approach

There continue to be important concerns about the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow injury. This is due to the fact that the hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. Based upon years of physiological and pathophysiological investigation of mammalian hematopoietic systems, and rigorous coarse-grained bio-mathematical modeling and validation on species from mouse, to dog, monkey, and human, we have developed a set of software tools Hemodose, which can use single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure to estimate absorbed doses of adult victims very rapidly and accurately. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. Most significant to the improvement of national and local preparedness of a potential nuclear/radiological disaster, this HemoDose approach establishes robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in the very late phase (up to 4 weeks) after exposure.

Hu, Shaowen↗

Effects of Texture and Silica Content on Crack Growth in Boron Nitrides

Boron nitride is used in applications such as crucibles for melting and casting glasses and metals, insulators for furnaces, molds for hot pressing, and neutron absorbers. Historically, various grades of hot pressed hexagonal boron nitride (BN) have been used. This study investigates the fracture toughness and slow crack growth parameters of several commercially available BN grades. Prior work revealed that some grades of BN absorb water and change strength, thus presenting a philosophical conundrum on crack growth test methods. The grades selected for this study are of interest because their available billet size is sufficient for large components, or because they have heritage in specific applications. Ultimately, the data will be used to perform material selection, system design and reliability analyses of components of interest. Boron nitrides exhibit limited slow crack growth in humidity, with an orientation dependence due to crystallographic texture: orientations with van der Waal bonds are insensitive to water whereas those with covalent bonds are sensitive. Fracture toughness is low, around that of glass, and is also a function of orientation (bond type), with fracture occurring more readily along van der Waal bonds between hexagonal BN platelets than at covalent bonds across platelets. Silica additions toughen BN, but increase slow crack growth susceptibility.

Salem, Jonathan A.↗

Macro-scale Testing and Micromechanics Modeling of Fracture Behaviors for Boron Carbide Composites with Hierarchical Microstructures

With a unique combination of properties including high hardness, low density, wear and corrosion resistance, thermal stability, high neutron absorption, and semi-conductivity, boron carbide (B4C) is a candidate material for various engineering applications that involve extreme environment. The current applications of boron carbide, however, are limited by its intrinsic brittleness due to its strong covalent bonding. To toughen boron carbide, in this work hierarchical microstructure designs was used to provide multiple toughening mechanisms including crack deflection/bridging, micro-crack toughening, etc. Using field assisted sintering, B4C composites with hierarchical microstructure features including graphite platelets, micron and sub-micron sized TiB2 reinforcements were fabricated. The fracture toughness of fabricated B4C composites were previously measured at micro-scale using micro-indentation followed by post-testing microstructure inspection. However, questions including whether the fracture toughness enhancement measured at micro-scale can translate to macro-scale mechanical properties, and what are the fundamental mechanisms behind observed fracture toughness enhancement, remain to be answered. In this study, the fabricated B4C composites were tested using standardized four-point bending method to obtain fracture toughness at macro-scale. In addition, micromechanics modeling was conducted using MAC/GMC code and crack-band model to study the effect of residual stress and weak interphases on fracture behaviors of B4C composites reinforced with TiB2 particles. Through standardized four-point bending tests, fracture toughness enhancements up to 2.85, 3.32, and 3.65 MPa∙m(exp 1/2) (from 2.38 MPa∙m(exp 1/2)) were achieved for B4C composites with graphite platelets addition (micro/nano B4C), with TiB2 formation (micro B4C-TiB2), and with both graphite and TiB2 addition (micro/nano B4C-TiB2) respectively. Micromechanics modeling indicated that introduction of thermal residual stress and weak interphases caused enhanced micro-cracking behavior and resulted in the observed fracture toughness enhancement. These results furthered understanding about the mechanical behaviors at macro-scale and the mechanisms behind observed fracture toughness enhancement for B4C composites with hierarchical microstructures and can provide reference data for the future design of B4C composites with optimized microstructures for further fracture toughness enhancement.

Boron Carbide↗

Fabrication of Extruded Polyphenylsulfone – Boron Nitride Composite Tapes

Polyphenylsulfone (PPSU) is a high-temperature, chemically resistant thermoplastic with high impact resistance that is often used in interior aircraft cabin components, medical devices, and membranes. The aforementioned properties have led to interest investigating PPSU’s compatibility with hexagonal boron nitride (hBN) platelets as a thermally conductive, electrical composite insulator for high power-density electric machines. Preliminary trials extruding PPSU-hBN composite tapes showed promising dielectric properties and higher thermal conductivity as a function of hBN concentration compared to their neat analog. On the other hand, only few studies have reported on the extrusion process and resulting thermo-mechanical properties for PPSU and its composites made with chopped fiber reinforcement or fillers, none of which containing boron nitride filler. Prospects may exist for this type of material to be incorporated into extrusion-based additive manufacturing techniques to print other composites bearing unique properties useful for aerospace. Loading levels with up to approximately 23 wt% were achieved using micro-size BN platelets without observing any significant affects to PPSU’s glass-transition temperature. This work includes a description of the rheological properties of PPSU, the extrusion parameters for mixing and compounding the PPSU-hBN composite tapes, and the thermal and thermo-mechanical properties of PPSU-hBN composites.

polyphenylsulfone↗

Fabrication of Extruded Polyphenylsulfone – Boron Nitride Composite Tapes

Polyphenylsulfone (PPSU) is a high-temperature, chemically resistant thermoplastic with high impact resistance that is often used in interior aircraft cabin components, medical devices, and membranes. The aforementioned properties have led to interest investigating PPSU’s compatibility with hexagonal boron nitride (hBN) platelets as a thermally conductive, electrical composite insulator for high power-density electric machines. Preliminary trials extruding PPSU-hBN composite tapes showed promising dielectric properties and higher thermal conductivity as a function of hBN concentration compared to their neat analog. On the other hand, only few studies have reported on the extrusion process and resulting thermo-mechanical properties for PPSU and its composites made with chopped fiber reinforcement or fillers, none of which contained boron nitride filler. Prospects may exist for this type of material to be incorporated into extrusion-based additive manufacturing techniques to print other composites bearing unique properties useful for aerospace. Loading levels with up to approximately 23 wt% were achieved using micro-size BN platelets without observing any significant affects to PPSU’s glass-transition temperature. This work includes a description of the rheological properties of PPSU, the extrusion parameters for mixing and compounding the PPSU-hBN composite tapes, and the thermal and thermo-mechanical properties of PPSU-hBN composites.

Tiffany Williams↗

Toughening of Boron Carbide Composites by Hierarchical Microstructuring

Due to a unique combination of properties including high hardness, low density, chemical and thermal stability, semi-conductivity, and high neutron absorption, boron carbide (B4C) is a potential candidate for various applications involving extreme environment. However, B4C’s current application is limited because of its low fracture toughness. In this study, a hierarchical microstructure design with features including TiB2 grains and graphite platelets was used to toughen B4C by simultaneously utilizing multiple toughening mechanisms including crack deflection, bridging, and micro-crack toughening. Using field-assisted sintering technology (FAST), B4C composites with dense and hierarchical microstructure were fabricated. Previously, the fracture toughness of fabricated B4C composites was measured at micro-scale using micro-indentation to have up to 56% improvement. In this work, the B4C composites’ fracture toughness was characterized at macro-scale using four-point bending methods and compared with previous results obtained at micro-scale. Micromechanics modeling of fracture behaviors for B4C-TiB2 composites was also performed to evaluate the contributions from experimentally observed toughening mechanisms. From four-point bending tests, B4C composites reinforced with both TiB2 grains (~15 vol%) and graphite platelets (~8.7 vol%) exhibited the highest fracture toughness enhancement from 2.38 to 3.65 MPa∙m^(1/2). The measured values were lower than those obtained using micro-indentation but maintained the general trends. The discrepancy between the indentation and four-point bending test results originated from the complex deformation behaviors triggered by the high contact load during indentation tests. Through micromechanics modeling, introduced thermal residual stress due to thermal expansion mismatch between B4C and TiB2, and weak interphases at B4C-TiB2 boundaries were identified as the main causes for experimentally observed toughness enhancement. These results proved the effectiveness of hierarchical microstructure designs for B4C toughening and can provide reference for the future design of B4C composites with optimized microstructures for further fracture toughness enhancement.

composites↗

Modeling and simulation of hydrogen behavior in Zircaloy-4 fuel cladding

As a result of corrosion during normal operation in nuclear reactors, hydrogen can enter the zirconium-alloy fuel cladding and precipitate as brittle hydride platelets, which can severely degrade the cladding ductility. Under a heterogeneous temperature distribution, hydrides tend to accumulate in the colder areas, creating local spots of degraded cladding that can favor crack initiation. Therefore, an estimation of the local hydride distribution is necessary to help predict the risk of cladding failure. The hydride distribution is governed by three competing phenomena. Hydrogen in solid solution diffuses under a concentration gradient due to Fick’s law and under a temperature gradient due to the Soret effect. Precipitation of the hydride platelets occurs once the hydrogen solubility limit is reached. A model of these phenomena was implemented in the 3D fuel performance code BISON in order to calculate the hydrogen distribution for arbitrary geometries, such as a nuclear fuel rod, and is now available for BISON users. Simulations have been performed on simple geometries to validate the model and its implementation. The simulations predict that before precipitation occurs, hydrogen tends to accumulate in the colder spots due to the Soret effect. Once the solubility limit is reached, hydrogen precipitates and forms a rim close to the outer edge of the cladding. The simulations also predict that the reactor shut down has little effect on already precipitated hydrides but causes the remaining hydrogen to precipitate homogeneously into hydrides.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydride Microstructure at the Metal-Oxide Interface of Zircaloy-4 from H.B. Robinson Nuclear Reactor

This study investigates the hydride rim microstructure at the metal-oxide interface of Zircaloy-4 cladding segment removed from H.B. Robinson Nuclear Reactor by utilizing high resolution electron microscopy techniques with energy dispersive x-ray spectroscopy at Oak Ridge National Laboratory under the NSUF Rapid Turnout Experiment program. A complex stacking and orientation of hydride platelets has been observed below the sub-oxide layer. Furthermore, radial hydride platelets have been observed. EDS signals of both Fe and Cr has been reduced within hydrides whereas EDS signal of Sn is unaffected.

EDS↗

The use of digital thread for reconstruction of local fiber orientation in a compression molded pin bracket via deep learning

A deep convolutional neural network (DCNN) was used for microstructure reconstruction using artificial intelligence (MR-AI) by predicting local average fiber orientation distributions (FOD) in a 3D prepreg platelet molded composite (PPMC) pin bracket. To train the MR-AI model, surface strain fields from residual stresses simulated in PPMC plates were used as the input to the DCNN. A training dataset included PPMC plates with various degrees of global fiber alignment, based on the information obtained from high-fidelity flow simulation of a pin bracket. Further, the MR-AI model was then deployed to analyze FOD in the 3D pin bracket by conducting thermo-elastic residual stress analysis. Initially, the MR-AI model was established entirely on the synthetic simulation data. Then, a μCT scan of a physically molded pin bracket was used to create a finite element model that provided data for additional validation of the DCNN model. For the μCT scan finite element pin bracket the MR-AI model predicted the distribution of fiber orientation tensor components with MAE of 0.10 indicating a global prediction error of 10%. For the flow simulated pin bracket, the MR-AI model predicted the distribution of fiber orientation tensor components with a global prediction error of 11%. The MR-AI model showed the ability to predict regions of varying alignment in the base and flange of the pin bracket. The proposed MR-AI methodology allows for rapid prediction of FOD in geometrically complex parts and offers a promising path to detecting unique fiber orientation states in molded components.

42 ENGINEERING↗

Autonomous conformational regulation of β 3 integrin and the conformation-dependent property of HPA-1a alloantibodies

Integrin α/β heterodimer adopts a compact bent conformation in the resting state, and upon activation undergoes a large-scale conformational rearrangement. During the inside-out activation, signals impinging on the cytoplasmic tail of β subunit induce the α/β separation at the transmembrane and cytoplasmic domains, leading to the extended conformation of the ectodomain with the separated leg and the opening headpiece that is required for the high-affinity ligand binding. It remains enigmatic which integrin subunit drives the bent-to-extended conformational rearrangement in the inside-out activation. The β 3 integrins, including α IIb β 3 and α V β 3 , are the prototypes for understanding integrin structural regulation. The Leu33Pro polymorphism located at the β 3 PSI domain defines the human platelet-specific alloantigen (HPA) 1a/b, which provokes the alloimmune response leading to clinically important bleeding disorders. Some, but not all, anti–HPA-1a alloantibodies can distinguish the α IIb β 3 from α V β 3 and affect their functions with unknown mechanisms. Here we designed a single-chain β 3 subunit that mimics a separation of α/β heterodimer on inside-out activation. Our crystallographic and functional studies show that the single-chain β 3 integrin folds into a bent conformation in solution but spontaneously extends on the cell surface. This demonstrates that the β 3 subunit autonomously drives the membrane-dependent conformational rearrangement during integrin activation. Using the single-chain β 3 integrin, we identified the conformation-dependent property of anti–HPA-1a alloantibodies, which enables them to differently recognize the β 3 in the bent state vs. the extended state and in the complex with α IIb vs. α V . Furthermore, this study provides deeper understandings of integrin conformational activation on the cell surface.

59 BASIC BIOLOGICAL SCIENCES↗

β-Subunit Binding Is Sufficient for Ligands to Open the Integrin α IIb β 3 Headpiece

The platelet integrin α IIb β 3 binds to a KQAGDV motif at the fibrinogen γ-chain C terminus and to RGD motifs present in loops in many extracellular matrix proteins. These ligands bind in a groove between the integrin α and β-subunits; the basic Lys or Arg side chain hydrogen bonds to the α IIb -subunit, and the acidic Asp side chain coordinates to a metal ion held by the β 3 -subunit. Ligand binding induces headpiece opening, with conformational change in the β-subunit. During this opening, RGD slides in the ligand-binding pocket toward α IIb , with movement of the βI-domain β1-α1 loop toward α IIb , enabling formation of direct, charged hydrogen bonds between the Arg side chain and α IIb . Here we test whether ligand interactions with β 3 suffice for stable ligand binding and headpiece opening. We find that the AGDV tetrapeptide from KQAGDV binds to the α IIb β 3 headpiece with affinity comparable with the RGDSP peptide from fibronectin. AGDV induced complete headpiece opening in solution as shown by increase in hydrodynamic radius. Soaking of AGDV into closed α IIb β 3 headpiece crystals induced intermediate states similarly to RGDSP. AGDV has very little contact with the α-subunit. Furthermore, as measured by epitope exposure, AGDV, like the fibrinogen γ C-terminal peptide and RGD, caused integrin extension on the cell surface. Thus, pushing by the β 3 -subunit on Asp is sufficient for headpiece opening and ligand sliding, and no pulling by the α IIb subunit on Arg is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circulating SARS-CoV-2 + megakaryocytes are associated with severe viral infection in COVID-19

Several independent lines of evidence suggest that megakaryocytes are dysfunctional in severe COVID-19. Herein, we characterized peripheral circulating megakaryocytes in a large cohort of inpatients with COVID-19 and correlated the subpopulation frequencies with clinical outcomes. Using peripheral blood, we show that megakaryocytes are increased in the systemic circulation in COVID-19, and we identify and validate S100A8/A9 as a defining marker of megakaryocyte dysfunction. We further reveal a subpopulation of S100A8/A9 + megakaryocytes that contain severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) protein and RNA. Using flow cytometry of peripheral blood and in vitro studies on SARS-CoV-2–infected primary human megakaryocytes, we demonstrate that megakaryocytes can transfer viral antigens to emerging platelets. Mechanistically, we show that SARS-CoV-2–containing megakaryocytes are nuclear factor κB (NF-κB)-activated, via p65 and p52; express the NF-κB–mediated cytokines interleukin-6 (IL-6) and IL-1β; and display high surface expression of Toll-like receptor 2 (TLR2) and TLR4, canonical drivers of NF-κB. In a cohort of 218 inpatients with COVID-19, we correlate frequencies of megakaryocyte subpopulations with clinical outcomes and show that SARS-CoV-2–containing megakaryocytes are a strong risk factor for mortality and multiorgan injury, including respiratory failure, mechanical ventilation, acute kidney injury, thrombotic events, and intensive care unit admission. Furthermore, we show that SARS-CoV-2 + megakaryocytes are present in lung and brain autopsy tissues from deceased donors who had COVID-19. To our knowledge, this study offers the first evidence implicating SARS-CoV-2 + peripheral megakaryocytes in severe disease and suggests that circulating megakaryocytes warrant investigation in inflammatory disorders beyond COVID-19.

60 APPLIED LIFE SCIENCES↗

Differential effects of intermittent and continuous administration of parathyroid hormone on bone histomorphometry and gene expression

A mechanism explaining the differential skeletal effects of intermittent and continuous elevation of serum parathyroid hormone (PTH) remains elusive. Intermittent PTH increases bone formation and bone mass and is being investigated as a therapy for osteoporosis. By contrast, chronic hyperparathyroidism results in the metabolic bone disease osteitis fibrosa characterized by osteomalacia, focal bone resorption, and peritrabecular bone marrow fibrosis. Intermittent and continuous PTH have similar effects on the number of osteoblasts and bone-forming activity. Many of the beneficial as well as detrimental effects of the hormone appear to be mediated by osteoblast-derived growth factors. This hypothesis was tested using cDNA microgene arrays to compare gene expression in tibia of rats treated with continuous and pulsatile administration of PTH. These treatments result in differential expression of many genes, including growth factors. One of the genes whose steady-state mRNA levels was increased by continuous but not pulsatile administration was platelet-derived growth factor-A (PDGF-A). Administration of a PDGF-A antagonist greatly reduced bone resorption, osteomalacia, and bone marrow fibrosis in a rat model for hyperparathyroidism, suggesting that PDGF-A is a causative agent for this disease. These findings suggest that profiling changes in gene expression can help identify the metabolic pathways responsible for the skeletal responses to the hormone.

Review↗

Acute, 2-week, and 13-week inhalation toxicity studies on dimethylethoxysilane vapor in Fischer 344 rats

Dimethylethoxysilane (DMES), a volatile liquid, is used by NASA to waterproof the heat-protective silica tiles and blankets on the Space Shuttle. Acute, 2-wk, and 13-wk inhalation exposures to DMES vapor were conducted in male and female Fischer 344 rats. In the acute study, rats were exposed to 4000, 2000, 1000, 500, or 0 (control) ppm DMES for 4 h and observed for 14 days. There were no deaths. Narcosis and ataxia were observed in rats of the two highest concentrations only. These signs disappeared within 1 h following exposure. There were no DMES-related gross or microscopic tissue lesions in rats of all exposure groups. In the 2-wk study, rats were exposed for 6 h/day, 5 days/wk to 3000, 1000, 300, 100, or 0 ppm DMES. During exposure, narcosis was observed in rats of the 3000 and 1000 ppm groups. There was a mild decrease in body weight gain in rats of the 3000 ppm group. A decrease in platelet count, an increase in bile acids, and reduced weights of the thymus, testis, and liver were observed in rats of the 3000 ppm group. Microscopically, hypospermatogenesis and spermatid giant cells were observed in the seminiferous tubules of the testes of rats exposed to 3000 ppm DMES. In the 13-wk study, rats were exposed 6 h/day, 5 days/wk to 2000, 600, 160, 40, or 0 ppm DMES. During exposure, rats of the 2000 ppm group exhibited mild narcosis and loss of startle reflex. Recovery from these central nervous system signs was rapid. Body weights were mildly decreased for rats of the 2000 ppm group. There were no exposure-related effects in hematology, serum chemistry, or urinalysis. Female rats of the 2000 ppm group had delayed estrous cycles (6 days compared to 5 days in control rats). Noteworthy organ weight changes in rats of the 2000 ppm group included decreases in thymus, liver, and testicular weights; however, pathologic lesions were observed in the testes only. Sperm motility, epididymal sperm count, and testicular spermatid count were dramatically reduced. Microscopic lesions included degeneration of the seminiferous tubular cells, pyknosis or absence of germ cells, and hypospermia in the epididymis. Rats of the 600 ppm group had a slight decrease in thymic weight and a transient decrease in body weight. Results of the acute, 2-wk, and 13-wk inhalation studies indicate DMES concentrations of 1000 ppm and higher produce narcosis that rapidly disappears following exposure. Repeated exposure of rats to DMES at either 3000 ppm for 2 wk or 2000 ppm for 13 wk caused testicular atrophy and hypospermia in male rats. Female rats exposed to 2000 ppm for 13 wk had delayed estrous cycles. Toxicological effects in rats of the 600 ppm group were minimal and equivocal. The 160 ppm concentration was a no-observable-effect level (NOEL) for 13 wk of exposure to DMES.

NASA Discipline Number 04-10↗

Stiff and Transparent Multilayer Thin Films Prepared Through Hydrogen-Bonding Layer-by-Layer Assembly of Graphene and Polymer [Super Stiff and Highly Transparent Multilayer Thin Films Prepared through Hydrogen-Bonding Layer-by-Layer Assembly of Graphene and Polymer]

Due to their exceptional orientation of 2D nanofillers, layer–by–layer (LbL) assembled polymer/graphene oxide thin films exhibit unmatched mechanical performance relative to any conventionally produced counterparts with similar composition. Unprecedented mechanical property improvement, by replacing graphene oxide with pristine graphene, is demonstrated in this work. Polyvinylpyrrolidone–stabilized graphene platelets are alternately deposited with poly(acrylic acid) using hydrogen bonding assisted LbL assembly. Transmission electron microscopy imaging and the Halpin–Tsai model are used to demonstrate, for the first time, that intact graphene can be processed from water to generate polymer nanocomposite thin films with simultaneous parallel–alignment, high packing density, and exfoliation. A multilayer thin film with only 3.9 vol% of highly exfoliated, and structurally intact graphene, increases the elastic modulus (E) of a polymer multilayer thin film by 322% (from 1.41 to 4.81 GPa), while maintaining visible light transmittance of ≈90%. This is one of the greatest improvements in elastic modulus ever reported for a graphene–filled polymer nanocomposite with a glassy (E > 1 GPa) matrix. In conclusion, the technique described here provides a powerful new tool to improve nanocomposite properties (mechanical, gas transport, etc.) that can be universally applied to a variety of polymer matrices and 2D nanoplatelets.

36 MATERIALS SCIENCE↗