Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A review of current anti-islanding methods for photovoltaic power system

Islanding phenomenon is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Until now, various anti-islanding methods (AIMs) for detecting and preventing islanding of photovoltaic and other distributed generations (DGs) have been proposed. This paper presents an overview of recent anti-islanding method developments for grid-connected photovoltaic (PV) power generation, focusing on the concept and operating principle, mainly based on single phase system. For the performance comparison, the experimental results of the various AIMs with 3 kW PV inverter are provided based on the islanding detection capability and power quality. As a result, the active AIMs have better islanding detection capability rather than the passive one. However, the active AIMs have power quality degradation on harmonic distortion or displacement power factor based on the injected active signal type. In addition to the evaluation and comparison of the main anti-islanding methods, this paper also summarizes the related anti-islanding standards to evaluate anti-islanding capability for PV system. This paper can be used as a useful anti-islanding reference for future work in DG like PV, and wind turbine. (author)

14 SOLAR ENERGY↗

Analysis to Inform CA Grid Integration Rules for PV: Final Report on Inverter Settings for Transmission and Distribution System Performance

The fourth solicitation of the California Solar Initiative (CSI) Research, Development, Demonstration and Deployment (RD&D) Program established by the California Public Utilities Commission (CPUC) supported the Electric Power Research Institute (EPRI), National Renewable Energy Laboratory (NREL), and Sandia National Laboratories (SNL) with data provided from Pacific Gas and Electric (PG&E), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E) conducted research to determine optimal default settings for distributed energy resource advanced inverter controls. The inverter functions studied are aligned with those developed by the California Smart Inverter Working Group (SIWG) and those being considered by the IEEE 1547 Working Group. The advanced inverter controls examined to improve the distribution system response included power factor, volt-var, and volt-watt. The advanced inverter controls examined to improve the transmission system response included frequency and voltage ride-through as well as Dynamic Voltage Support. This CSI RD&D project accomplished the task of developing methods to derive distribution focused advanced inverter control settings, selecting a diverse set of feeders to evaluate the methods through detailed analysis, and evaluating the effectiveness of each method developed. Inverter settings focused on the transmission system performance were also evaluated and verified. Based on the findings of this work, the suggested advanced inverter settings and methods to determine settings can be used to improve the accommodation of distributed energy resources (PV specifically). The voltage impact from PV can be mitigated using power factor, volt-var, or volt-watt control, while the bulk system impact can be improved with frequency/voltage ride-through.

14 SOLAR ENERGY↗

On the Design of High Efficiency Thermoelectric Type I Clathrates through Transition Metal Doping

The lack of high efficiency thermoelectric materials hinders their deployment into wide ranging applications such as power generation from waste heat and solid state heating and cooling, which could lead to significant energy savings. Type I clathrates have recently been identified as prospective thermoelectric materials for power generation purposes due to their very low lattice thermal conductivity values. The maximum thermoelectric figure of merit of almost all type I clathrates is, however, less than 1; and occurs at, or above, 1000 K making them unfavorable especially for intermediate temperature applications. In this report, we demonstrate that transition metal doping introduces charge distortion and lattice defects into these materials which increases the ionized impurity scattering of carriers and point defect scattering of lattice phonons, respectively; leading to an enhanced power factor, reduced lattice thermal conductivity, and therefore improved thermoelectric figure of merit. Most importantly, the band gap of these materials can be tuned between 0.1 eV and 0.5 eV by adjusting the transition metal content, making it possible to design type I clathrates with excellent thermoelectric properties between 500 K and 1000 K.

36 MATERIALS SCIENCE↗

Influence of rare-earth elements doping on thermoelectric properties of Ca{sub 0.98}Dy{sub 0.02}MnO{sub 3} at high temperature

Ca{sub 0.98}Dy{sub 0.02}MnO{sub 3} and Ca{sub 0.96}Dy{sub 0.02}Re{sub 0.02}MnO{sub 3} (Re=La, Pr, Sm, Eu, Ho, and Yb) have been synthesized by the solid state reaction method. Samples with relative densities all over 96% have been obtained. Thermoelectric properties are evaluated between 300 and 1000 K. The electrical resistivity shows a typical metal-like conductivity behavior, and at high temperature, 973 K, decreases from 36.1 mΩ cm for Ca{sub 0.98}Dy{sub 0.02}MnO{sub 3} to 8.6 mΩ cm for Ca{sub 0.96}Dy{sub 0.02}Yb{sub 0.02}MnO{sub 3}. Both the absolute values of Seebeck coefficient and thermal conductivity are reduced by the introduction of second rare-earth element. The highest power factor of 415 μW/(K{sup 2}m) is obtained for Ca{sub 0.96}Dy{sub 0.02}Yb{sub 0.02}MnO{sub 3} sample, resulting in the highest dimensionless figure of merit (ZT) 0.25 at 973 K. This value shows an improvement of 144% compared with that of Ca{sub 0.98}Dy{sub 0.02}MnO{sub 3} ceramics at the same temperature. - Graphical abstract: The Ca{sub 0.96}Dy{sub 0.02}Re{sub 0.02}MnO{sub 3} (Re=La, Pr, …, Yb) were prepared by solid state reaction. Highest ZT value obtained is 0.25 at 973 K for Re=Yb, which shows 144% improvement compared with Ca{sub 0.98}Dy{sub 0.02}MnO{sub 3}. - Highlights: • Ca{sub 0.96}Dy{sub 0.02}Re{sub 0.02}MnO{sub 3} (Re=La, Pr, …, Yb) are produced by solid state reaction. • Lowest resistivity is obtained due to the highest carrier mobility for Re=Yb. • Highest power factor obtained is 415 μW/(K{sup 2}m) at 973 K for Re=Yb. • Highest ZT value obtained is 0.25 at 973 K for Ca{sub 0.96}Dy{sub 0.02}Yb{sub 0.02}MnO{sub 3} sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pressure-induced phase transition and electrical properties of thermoelectric Al-doped Mg{sub 2}Si

A recent study has shown the thermoelectric performance of Al-doped Mg{sub 2}Si materials can be significantly enhanced at moderate pressure. To understand the cause of this phenomenon, we have performed in situ angle dispersive X-ray diffraction and infrared reflectivity measurements up to 17 GPa at room temperature. Contrary to previous experiment, using helium as a pressure transmission medium, no structural transformation was observed in pure Mg{sub 2}Si. In contrast, a phase transition from cubic anti-fluorite (Fm-3m) to orthorhombic anti-cotunnite (Pnma) was observed in the Al-doped sample at 10 GPa. Infrared reflectivity measurements show the electrical conductivity increases with pressure and is further enhanced after the phase transition. The electron density of states at the Fermi level computed form density functional calculations predict a maximum thermoelectric power factor at 1.9 GPa, which is in good agreement with the experimental observation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ca-for-Sr substitution in the thermoelectric [(Sr,Ca){sub 2}(O,OH){sub 2}]{sub q}[CoO{sub 2}] misfit-layered cobalt-oxide system

Calcium-for-strontium substituted samples of the misfit-layered cobalt-oxide system, [(Sr{sub 1-x}Ca{sub x}){sub 2}(O,OH){sub 2}]{sub q}[CoO{sub 2}], were successfully synthesized up to x=0.2 with a sample-encapsulation technique originally developed for the x=0 end phase. While the x=0 sample has a commensurate match between the two layer blocks (i.e. q=0.5), isovalent Ca-for-Sr substitution induces lattice misfit (i.e. q>0.5). At the same time the Seebeck coefficient gets increased, but the increase in resistivity results in suppressing the thermoelectric power factor. The magnetic anomaly in the x=0 sample gets released upon the Ca substitution for the x=0.2 sample to exhibit an almost Curie-Weiss behavior. It is concluded that with increasing x in [(Sr{sub 1-x}Ca{sub x}){sub 2}(O,OH){sub 2}]{sub q}[CoO{sub 2}] the properties smoothly evolve towards those previously reported for the x=1.0 end member, [Ca{sub 1.7}O{sub 2.1}H{sub 2.4}]{sub 0.58}[CoO{sub 2}]. -- Graphical abstract: In the misfit-layered [(Sr{sub 1-x}Ca{sub x}){sub 2}(O,OH){sub 2}]{sub q}[CoO{sub 2}] (0.0{<=}x{<=}0.2) system the x=0 phase has a commensurate match between the two layer blocks (i.e. q=0.5), while isovalent Ca-for-Sr substitution induces lattice misfit (i.e. q>0.5). At the same time Seebeck coefficient gets increased. Simultaneous increase in resistivity however outweighs this benefit, and accordingly the thermoelectric power factor is decreased. Display Omitted

36 MATERIALS SCIENCE↗

Coherent magnetic nanoinclusions induce charge localization in half-Heusler alloys leading to high- T c ferromagnetism and enhanced thermoelectric performance

Performance improvement traditionally realized through a combination of power factor optimization via electronic doping and lattice thermal conductivity reduction using nanostructuring have reached their optimal limits in many leading thermoelectric materials, making further enhancement in the thermoelectric figure of merit extremely challenging. Here, a novel approach to electronic transport engineering using coherent magnetic nanoinclusions is demonstrated. It was found that the incorporation of coherent magnetic full-Heusler (FH) nanoinclusions (Ti(Ni 4/3 Fe 2/3 )Sn) into a half-Heusler (HH) matrix (Ti 0.25 Zr 0.25 Hf 0.5 NiSn 0.975 Sb 0.025 ) with optimal doping level and lattice thermal conductivity leads to high Curie temperature ferromagnetism (T c ~ 650 K) along with a large reduction in the effective carrier density within the HH matrix. It is believed that the embedded magnetic FH nanoinclusions interact with the spin of itinerant carriers, leading to charge localization and the formation of overlapping bound magnetic polarons (BMPs). This gives rise to significant enhancements of both carrier mobility and thermopower, which minimizes the reduction in the overall power factor, simultaneously with a large drop in the total thermal conductivity owing to the reduction of the electronic contribution to the thermal conductivity. Here, whe implementation of the magnetic nanoinclusions strategy in a variety of state-of-the-art thermoelectric materials could pave the way towards even larger figures of merit.

36 MATERIALS SCIENCE↗

Earth Abundant High Temperature Materials for Radioisotope Power Conversion System

Advances in high temperature thermoelectric materials were made and published. Two major developments are out lined in this final report. Alkaline earth Zintl phases represent the starting point of a series of compounds selected for development due to their high abundance as the supply chain and as the availability of certain rare earths (i.e. Yb) are limited and can be difficult to obtain. A new Zintl phase, Ca 14 MnSb 11-x Sn x , where Sb is replaced by Sn resulting in changes to the band structure and properties. The structures are investigated by powder diffraction and samples consolidated into fully dense pellets for thermoelectric measurements. The band structure of a reasonable structure, Ca 14 MgSb 7 Sn 4 , is calculated in order to better understand the properties. These Sn containing phases show improved thermoelectric properties over Ca 14 MgSb 11 by increasing the Seebeck while decreasing resistivity without significant impact to the already low thermal conductivity. In addition, a composite phase of Yb 14 MgSb 11 was investigated. Composite phases have been shown to improve both the thermoelectric efficiency and mechanical properties of materials. Here we demonstrate an improved thermoelectric figure of merit, power factor, and mechanical properties for the high-temperature p-type Zintl phase Yb 14 MgSb 11 . Composites with 0, 1, 2, 3, 4, 6, 8 volume % 6 – 10 µm reduced Fe powder were prepared via a fast, scalable mechanical milling and spark plasma sintering procedure. Powder X-ray diffraction, scanning electron microscopy, and transmission electron microscopy show that Fe is not incorporated into the Yb 14 MgSb 11 structure. First order reversal curves and scanning electron microscopy images show that the Fe inclusions are larger and closer together with increasing Fe content. Thermogravimetric and differential scanning calorimetry show that the composites are stable up to 1273 K. The elastic constants of the 8 volume % Fe composite were measured by resonant ultrasound spectroscopy and show that Yb 14 MgSb 11 becomes stiffer with increasing Fe volume % and SEM after indentations show crack arresting occurs at the Fe interface. Thermoelectric properties on dense pellets are measured from 300 K – 1273 K. The thermoelectric power factor (PF= $\frac{S^2}{ρ}$) increases with increasing Fe content, with the 8 volume % Fe resulting in 40% higher PF than pristine Yb 14 MgSb 11 . The increase in PF is attributed to a systematic reduction in electrical resistivity. Peak thermoelectric figure of merit (zT= ($\frac{S^2T}{κρ}$) is observed at 3 volume % Fe, an 11% improvement in zT compared to Yb 14 MgSb 11 . Yb 14 MgSb 11 composites with Fe are compatible with Ce 0.9 Fe 3.5 Co 0.5 Sb 12 for thermoelectric generator couple segmentation.

30 DIRECT ENERGY CONVERSION↗

Design Considerations of a Transverse Flux Machine for Direct-Drive Wind Turbine Applications

This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The TFM has a modular structure with quasi-U stator cores and ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating arrangement to achieve high air gap flux density. The design considerations for this TFM with respect to initial sizing, pole number selection, key design ratios, and pole shaping are presented in this paper. Pole number selection is critical in the design process of a TFM because it affects both the torque density and power factor under fixed magnetic and changing electrical loading. Several key design ratios are introduced to facilitate the design procedure. The effect of pole shaping on back-emf and inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis. A prototype is under construction for experimental verification.

17 WIND ENERGY↗

Residential Advanced Photovoltaic Inverter Pilot Study Results for Select Distribution Secondaries in Hawai'i

Penetration levels of residential rooftop solar photovoltaic (PV) generation on the Hawaiian island of O'ahu have increased significantly in recent years, with many circuits now at the limits of their PV hosting capacity. NREL and Hawaiian Electric have used this opportunity to deploy advanced inverters at new customer installations that would not otherwise have been approved, as a pilot study to gain first-hand operational field data and experience on the impact of inverter-based grid support functions. At each customer location, the deployed advanced inverters were remotely controlled and monitored. Additionally, customer AMI (smart meter) and secondary distribution transformer data was also available for the analysis. The analysis focused on quantifying the customer behind-the-meter voltage rise due to PV production, determining the customer voltage rise with advanced inverters in unity power factor as well as advanced grid support function modes, and estimating the curtailment when inverters have Volt-VAR and Volt-Watt enabled. The results show that: 1) Behind-the-meter voltage rise is often not negligible. 2) An inverter's operating point on a Volt-VAR/Volt-Watt curve depends strongly on the design of the secondary system on which it is installed. 3) The mitigation of voltage rise on the secondary system using Volt-VAR may not be effective if only a small proportion of inverters have grid support enabled, or if the reactance/resistance (X/R) ratio of the grid is low. 4) Volt-Watt curtailment can be estimated using co-located irradiance sensors but there may be opportunities to estimate it using inverter internal electrical measurements. 5) Estimated curtailment is very low for the locations analyzed to date.

14 SOLAR ENERGY↗

Bottom-up design of de novo thermoelectric hybrid materials using chalcogenide resurfacing

Hybrid organic/inorganic thermoelectric materials based on conducting polymers and inorganic nanostructures have been demonstrated to combine both the inherently low thermal conductivity of the polymer and the superior charge transport properties (high power factors) of the inorganic component. While their performance today still lags behind that of conventional inorganic thermoelectric materials, solution-processable hybrids have made rapid progress and also offer unique advantages not available to conventional rigid inorganic thermoelectrics, namely: (1) low cost fabrication on rigid and flexible substrates, as well as (2) engineering complex conformal geometries for energy harvesting/cooling. While the number of reports of new classes of viable hybrid thermoelectric materials is growing, no group has reported a general approach for bottom-up design of both p- and n-type materials from one common base. Thus, unfortunately, the literature comprises mostly of disconnected discoveries, which limits development and calls for a first-principles approach for property manipulation analogous to doping in traditional semiconductor thermoelectrics. Here, molecular engineering at the organic/inorganic interface and simple processing techniques are combined to demonstrate a modular approach enabling de novo design of complex hybrid thermoelectric systems. Here, we chemically modify the surfaces of inorganic nanostructures and graft conductive polymers to yield robust solution processable p- and n-type inorganic/organic hybrid nanostructures. Our new modular approach not only offers researchers new tools to perform true bottom-up design of thermoelectric hybrids, but also strong performance advantages as well due to the quality of the designed interfaces. For example, we obtain enhanced power factors in existing (by up to 500% in Te/PEDOT:PSS) and novel (Bi 2 S 3 /PEDOT:PSS) p-type systems, and also generate water-processable and air-stable high performing n-type hybrid systems (Bi 2 Te 3 /PEDOT:PSS), thus highlighting the potency of our ex situ strategy in opening up new material options for thermoelectric applications. Finally, this strategy establishes a unique platform with broad handles for custom tailoring of thermal and electrical properties through hybrid material tunability and enables independent control over inorganic material chemistry, nanostructure geometry, and organic material properties, thus providing a robust pathway to major performance enhancements.

36 MATERIALS SCIENCE↗

Adaptive Voltage Regulation for Solar Power Inverters on Distribution Systems

The most recent version of IEEE 1547 has incorporated four reactive power control modes, including constant power factor, voltage-reactive power (Volt-Var), active power-reactive power and constant reactive power. These modes are specified to be mutually exclusive, and they don’t include every smart inverter function proposed by industry collaboration. In earlier work, we found that Volt-Var settings could be optimized but were sensitive to changes in the normal grid voltage. This sensitivity can be mitigated by combining Volt-Var with dynamic reactive current (DRC), but neither DRC nor combined modes appear in IEEE 1547. One problem with Volt-Var is the default dead-band; it mitigates the sensitivity to setpoint, but also limits the effectiveness in managing voltage fluctuations. There has been continued interest in tuning smart inverter functions locally, and in combining central with local control, but this process still requires extensive simulations. The goal is to find a default inverter setting that will effectively mitigate voltage fluctuations even as grid conditions change. It must be compatible with the current version of IEEE 1547. It should also be compatible with advanced control methods when available. Otherwise, it should not require communications, detailed engineering studies or field commissioning of custom settings. This would facilitate the integration of distributed solar in larger amounts. Adaptive voltage regulation (AVR) is a Volt-Var implementation, but with “autonomously adjusting” setpoint as described below Table 8 in IEEE 1547. Through simulation of a test system in OpenDSS, it was shown that AVR having a high gain and a time constant of 300 seconds could work well in any location. This mode and setting should be considered for a new universal default setting on smart inverters.

McDermott, Thomas E.↗

Vehicular Integration of Wireless Power Transfer Systems and Hardware Interoperability Case Studies

Several wireless charging methods are under development or available as an aftermarket option in the light-duty automotive market. However, there are not a sufficient number of studies detailing the vehicle integration methods, particularly a complete vehicle integration with higher power levels. This paper presents the design, development, implementation, and vehicle integration of wireless power transfer (WPT)-based electric vehicle (EV) charging systems for various test vehicles. Before having the standards effective, it is expected that WPT technology first will be integrated as an aftermarket retrofitting approach. Inclusion of this technology on production vehicles is contingent upon the release of the international standards. The power stages of the system are introduced with the design specifications and control systems including the active front-end rectifier with power factor correction, high frequency power inverter, high frequency isolation transformer, coupling coils, vehicle side full-bridge rectifier and filter, and the vehicle battery. The operating principles of the control, and communications, systems are presented. Aftermarket conversion approaches including the WPT on-board charger (OBC) integration, WPT CHAdeMO integration, and WPT direct battery connection scenarios are described. Furthermore, the experiments are carried out using the integrated vehicles and the results obtained to demonstrate the system performance including the stage-by-stage efficiencies.

42 ENGINEERING↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Integral inverter/battery charger for use in electric vehicles

The design and test results of a thyristor based inverter/charger are discussed. A battery charger is included integral to the inverter by using a subset of the inverter power circuit components. The resulting charger provides electrical isolation between the vehicle propulsion battery and ac line and is capable of charging a 25 kWh propulsion battery in 8 hours from a 220 volt ac line. The integral charger employs the inverter commutation components at a resonant ac/dc isolated converter rated at 3.6 kW. Charger efficiency and power factor at an output power of 3.6 kW are 86% and 95% respectively. The inverter, when operated with a matching polyphase ac induction motor and nominal 132 volt propulsion battery, can provide a peak shaft power of 34 kW (45 ph) during motoring operation and 45 kW (60 hp) during regeneration. Thyristors are employed for the inverter power switching devices and are arranged in an input-commutated topology. This configuration requires only two thyristors to commutate the six main inverter thyristors. Inverter efficiency during motoring operation at motor shaft speeds above 450 rad/sec (4300 rpm) is 92-94% for output power levels above 11 KW (15 hp). The combined ac inverter/charger package weighs 47 kg (103 lbs).

Thimmesch, D.↗

Methods of integrating a high penetration photovoltaic power plant into a micro grid.

The island of Lanai is currently one of the highest penetration PV micro grids in the world, with the 1.2 MWAC La Ola Solar Farm operating on a grid with a peak net load of 4.7 MW. This facility interconnects to one of Lanai's three 12.47 kV distribution circuits. An initial interconnection requirements study (IRS) determined that several control and performance features are necessary to ensure safe and reliable operation of the island grid. These include power curtailment, power factor control, over/under voltage and frequency ride through, and power ramp rate limiting. While deemed necessary for stable grid operation, many of these features contradict the current IEEE 1547 interconnection requirements governing distributed generators. These controls have been successfully implemented, tested, and operated since January 2009. Currently, the system is producing power in a curtailed mode according to the requirements of a power purchase agreement (PPA).

14 SOLAR ENERGY↗

Different Factors Affecting Short Circuit Behavior of a Wind Power Plant

A wind power plant consists of a large number of turbines interconnected by underground cable. A pad-mount transformer at each turbine steps up the voltage from generating voltage (690 V) to a medium voltage (34.5 kV). All turbines in the plant are connected to the substation transformer where the voltage is stepped up to the transmission level. An important aspect of wind power plant (WPP) impact studies is to evaluate the short-circuit (SC) current contribution of the plant into the transmission network under different fault conditions. This task can be challenging to protection engineers due to the topology differences between different types of wind turbine generators (WTGs) and the conventional generating units. This paper investigates the short circuit behavior of a wind power plant for different types of faults. The impact of wind turbine types, the transformer configuration, and the reactive compensation capacitor will be investigated. The voltage response at different buses will be observed. Finally, the SC line currents will be presented along with its symmetrical components.

17 WIND ENERGY↗