Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTOCOLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Generalized echo squeezing protocol with near-Heisenberg-limit sensitivity and strong robustness against detection noise and variation in squeezing parameter

We present a generalized echo squeezing protocol (GESP) as a generalization of the Schrödinger cat state protocol with the value of the squeezing parameter being an arbitrary number rather than π / 2 . We show analytically that over a very broad range of the squeezing parameter the sensitivity of the GESP reaches the Heisenberg limit within a factor of 2 . For a large number of atoms, N , this plateau interval is almost the whole range from zero to π / 2 , and the sensitivity is independent of the parity of N . Therefore, it is possible to operate a sensor over a wide interval of the squeezing parameter without changing the sensitivity. This is to be contrasted with the conventional echo squeezing protocol (CESP) which only works for a very small interval of the squeezing parameter. We also show that, in contrast to the CESP, the sensitivity of the GESP is close to the quantum Cramér-Rao bound over the whole range of the squeezing parameter, indicating that the phase-shift information contained in the quantum state is near-optimally extracted. We find that the enhancement in sensitivity in the case of the GESP is due to a combination of two parameters: the phase magnification factor (PMF) and the noise amplification factor (NAF). As the value of the squeezing parameter increases, both PMF and NAF increase, while keeping the ratio of the PMF to the NAF essentially constant, yielding a net enhancement of sensitivity at the Heisenberg limit within a factor of 2 over the whole plateau interval. An important consequence of this behavior is that the robustness of the GESP against detection noise easily exceeds that of the CESP for a broad range of values of the squeezing parameter. As such, in the context of an experimental study, it should be possible to achieve a net enhancement in sensitivity higher than that for the CESP, under typical conditions where detection noise exceeds the quantum projection noise of an unsqueezed state with the same number of atoms. Finally, we consider the fragility of the GESP against decoherence mechanisms, and show how a balance between the fragility against the decoherence mechanisms and the robustness against detection noise would in practice determine the optimal choice of parameters for the GESP.

Li, Jinyang↗

Optimizing local protocols for implementing bipartite nonlocal unitary gates using prior entanglement and classical communication

We present a method of optimizing recently designed protocols for implementing an arbitrary nonlocal unitary gate acting on a bipartite system. These protocols use only local operations and classical communication with the assistance of entanglement, and they are deterministic while also being 'one-shot', in that they use only one copy of an entangled resource state. The optimization minimizes the amount of entanglement needed, and also the amount of classical communication, and it is often the case that less of each of these resources is needed than with an alternative protocol using two-way teleportation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comment on 'Two-way protocols for quantum cryptography with a nonmaximally entangled qubit pair'

Three protocols of quantum cryptography with a nonmaximally entangled qubit pair [Phys. Rev. A 80, 022323 (2009)] were recently proposed by Shimizu, Tamaki, and Fukasaka. The security of these protocols is based on the quantum-mechanical constraint for a state transformation between nonmaximally entangled states. However, we find that the second protocol is vulnerable under the correlation-elicitation attack. An eavesdropper can obtain the encoded bit M although she has no knowledge about the random bit R.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Insecurity of position-based quantum-cryptography protocols against entanglement attacks

Recently, position-based quantum cryptography has been claimed to be unconditionally secure. On the contrary, here we show that the existing proposals for position-based quantum cryptography are, in fact, insecure if entanglement is shared among two adversaries. Specifically, we demonstrate how the adversaries can incorporate ideas of quantum teleportation and quantum secret sharing to compromise the security with certainty. The common flaw to all current protocols is that the Pauli operators always map a codeword to a codeword (up to an irrelevant overall phase). We propose a modified scheme lacking this property in which the same cheating strategy used to undermine the previous protocols can succeed with a rate of at most 85%. We prove the modified protocol is secure when the shared quantum resource between the adversaries is a two- or three-level system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing a dynamical decoupling protocol for solid-state electronic spin ensembles in diamond

In this study, we demonstrate significant improvements of the spin coherence time of a dense ensemble of nitrogen-vacancy (NV) centers in diamond through optimized dynamical decoupling (DD). Cooling the sample down to 77 K suppresses longitudinal spin relaxation T 1 effects and DD microwave pulses are used to increase the transverse coherence time T 2 from ~0.7ms up to ~30ms. Furthermore, we extend previous work of single-axis (Carr-Purcell-Meiboom-Gill) DD towards the preservation of arbitrary spin states. Following a theoretical and experimental characterization of pulse and detuning errors, we compare the performance of various DD protocols. We also identify that the optimal control scheme for preserving an arbitrary spin state is a recursive protocol, the concatenated version of the XY8 pulse sequence. The improved spin coherence might have an immediate impact on improvements of the sensitivities of ac magnetometry. Moreover, the protocol can be used on denser diamond samples to increase coherence times up to NV-NV interaction time scales, a major step towards the creation of quantum collective NV spin states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Free-energy estimates from nonequilibrium trajectories under varying-temperature protocols

The Jarzynski equality allows the calculation of free-energy differences using values of work measured from nonequilibrium trajectories. The number of trajectories required to accurately estimate free-energy differences in this way grows sharply with the size of work fluctuations, motivating the search for protocols that perform desired transformations with minimum work. However, protocols of this nature can involve varying temperature, to which the Jarzynski equality does not apply. Here, we derive a variant of the Jarzynski equality that applies to varying-temperature protocols, and show that it can have better convergence properties than the standard version of the equality. We derive this modified equality and the associated fluctuation relation within the framework of Markovian stochastic dynamics, complementing related derivations done within the framework of Hamiltonian dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unified, Geometric Framework for Nonequilibrium Protocol Optimization

Controlling thermodynamic cycles to minimize the dissipated heat is a long-standing goal in thermodynamics, and more recently, a central challenge in stochastic thermodynamics for nanoscale systems. Here, we introduce a theoretical and computational framework for optimizing nonequilibrium control protocols that can transform a system between two distributions in a minimally dissipative fashion. These protocols optimally transport a system along paths through the space of probability distributions that minimize the dissipative cost of a transformation. Furthermore, we show that the thermodynamic metric—determined via a linear response approach—can be directly derived from the same objective function that is optimized in the optimal transport problem, thus providing a unified perspective on thermodynamic geometries. As a result, we investigate this unified geometric framework in two model systems and observe that our procedure for optimizing control protocols is robust beyond linear response.

36 MATERIALS SCIENCE↗

Excitation protocols for nonlinear phononics in bismuth and antimony

Here, we study the optical generation and control of coherent phonons in elemental bismuth (Bi) and antimony (Sb) using a classical equation of motion informed by first-principles calculations of the potential energy surface and the frequency-dependent macroscopic dielectric function along the zone-centered optical phonon coordinates. Using this approach, we demonstrate that phonons with the largest optomechanical couplings also have the strongest degree of anharmonicity among the zone-centered modes, a result of the broken-symmetry structural ground state of Bi and Sb. We show how this anharmonicity, explaining the light-induced phonon softening observed in experiments, prevents the application of standard phonon-amplification and annihilation protocols. We introduce a simple linearization protocol that extends the use of such protocols to the case of anharmonic phonons in broken-symmetry materials, and demonstrate its efficiency at high displacement amplitudes. Our formalism and results provide a path for improving optical control in nonlinear phononics.

36 MATERIALS SCIENCE↗

Transmission of Images With Ultrasonic Elastic Shear Waves on a Metallic Pipe Using Amplitude Shift Keying Protocol

Transmission of information using ultrasonic elastic waves on existing metallic pipes provides an alternative communication option across physical barriers in a highly partitioned industrial complex, such as a nuclear facility. This work investigates the feasibility of the transmission of digital images over metallic pipes. Ultrasonic communication systems for transmission of images on a nuclear-grade stainless steel pipe were assembled for bench-scale demonstration. Information carriers in this system are refracted shear waves transmitted and received with piezoelectric transducers (PZTs) operating at 2-MHz nominal frequency. The refraction and propagation of ultrasonic shear waves were modeled with COMSOL software. An amplitude shift keying (ASK) communication protocol for image transmission was developed and implemented in the GNURadio software-defined radio (SDR) environment. Digital information was converted to analog ultrasonic signals using Red Pitaya electronic boards. The performance of the ASK protocol is evaluated at the output of every block in the GNURadio program by monitoring the transmission of select characters. Using the ASK communication protocol, the transmission of the 32-KB image was demonstrated at 2-Kbps bitrate across 6-ft-long stainless steel pipe. Finally, preliminary evaluation of ultrasonic communication on the piping of a nuclear facility, such as signal transmission on bent pipes, was performed with COMSOL computer simulations.

42 ENGINEERING↗

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetry protocol for the preclinical trials in white-beam minibeam radiation therapy

Purpose: In the quest of a curative radiotherapy treatment for gliomas, new delivery modes are being explored. At the Biomedical Beamline of the European Synchrotron Radiation Facility, a new spatially fractionated technique, called minibeam radiation therapy (MBRT), is under development. The aims of this work were to assess different dosimetric aspects and to establish a dosimetry protocol to be applied in the forthcoming animal (rat) studies in order to evaluate the therapeutic index of this new radiotherapy approach. Methods: Absolute dosimetry was performed with a thimble ionization chamber (PTW semiflex 31010) whose center was positioned at 2 g cm{sup -2} depth. To translate the dose measured in broad beam configuration to the dose deposited with a minibeam, the scatter factors were used. Those were assessed by using the Monte Carlo simulations and verified experimentally with Gafchromic films and a Bragg Peak chamber. The comparison of the theoretical and experimental data were used to benchmark the calculations. Finally, the dose distributions in a rat phantom were evaluated by using the validated Monte Carlo calculations. Results: The absolute dosimetry in broad beam configuration was measured in reference conditions. The dose rate was in the range between 168 and 224 Gy/min, depending on the storage ring current. A scatter factor of 0.80 {+-} 0.04 was obtained. Percentage depth dose and lateral profiles were evaluated both in homogenous and heterogeneous slab phantoms. The general good agreement between Monte Carlo simulations and experimental data permitted the benchmark of the calculations. Finally, the peak doses in the rat head phantom were assessed from the measurements in reference conditions. In addition, the peak-to-valley dose ratio values as a function of depth in the rat head were evaluated. Conclusions: A new promising radiotherapy approach is being explored at the ESRF: Minibeam Radiation Therapy. To assess the therapeutic index of this new modality, in vivo experiments are being planned, for which an accurate knowledge of the dosimetry is essential. For that purpose, a complete set of measurements and Monte Carlo simulations was performed. The first dosimetry protocol for preclinical trials in minibeam radiation therapy was established. This protocol allows to have reproducibility in terms of dose for the different biological studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-19: CTDI Values for All Protocols: Using the Ratio of the DLP Measured in CTDI Phantoms to the Measured Air Exposure

Purpose: To propose a method other than CTDI phantom measurements for routine CT dosimetry QA. This consists of taking a series of air exposure measurements and calculating a factor for converting from this exposure measurement to the protocol's associated head or body CTDI value using DLP. The data presented are the ratios of phantom DLP to air exposure ratios for different scanners, as well as error in the displayed CTDI. Methods: For each scanner, the CTDI is measured at all available tube voltages using both the head and body phantoms. Then, the exposure is measured using a pencil chamber in air at isocenter. A ratio of phantom DLP to exposure in air for a given protocol may be calculated and used for converting a simple air dose measurement to a head or body CTDI value. For our routine QA, the exposure in air for different collimations, mAs, and kVp is measured, and displayed CTDI is recorded. Therefore, the ratio calculated may convert these exposures to CTDI values that may then be compared to the displayed CTDI for a large range of acquisition parameter combinations. Results: It was found that all scanners tend to have a ratio factor that slightly increases with kVp. Also, Philips scanners appear to have less of a dependence on kVp; whereas, GE scanners have a lower ratio at lower kVp. The use of air exposure times the DLP conversion yielded CTDI values that were less than 10% different from the displayed CTDI on several scanners. Conclusion: This method may be used as a primary method for CT dosimetry QA. As a result of the ease of measurement, a dosimetry metric specific to that scanner may be calculated for a wide variety of CT protocols, which could also be used to monitor display CTDI value accuracy.

60 APPLIED LIFE SCIENCES↗

SU-E-J-07: A Functional MR Protocol for the Pancreatic Tumor Delineation

Purpose: Pancreatic cancer is one of the cancers with the poorest survival prognosis. At the time of diagnosis most of pancreatic cancers are unresectable and those patients can be treated by radiotherapy. Radiotherapy for pancreatic cancer is limited due to uncertainties in CT-based delineations. MRI provides an excellent soft tissue contrast. Here, an MR protocol is developed to improve delineations for radiotherapy treatment of pancreatic cancer. In a later stage this protocol can also be used for on-line visualization of the pancreas during MRI guided treatments. Methods: Nine pancreatic cancer patients were included. The MR protocol included T2 weighted(T2w), T1 weighted(T1w), diffusion weighted(DWI) and dynamic contrast enhanced(DCE) techniques. The tumor was delineated on T2w and T1w MRI by an experienced radiation oncologist. Healthy pancreas or pancreatitis (assigned by the oncologist based on T2w) areas were also delineated. Apparent diffusion coefficient(ADC), and area under the curve(AUC)/time to peak(TTP) maps were obtained from DWI and DCE scans, respectively. Results: A clear demarcation of tumor area was visible on b800 DWI images in 5 patients. ADC maps of those patients characterized tumor as an area with restricted water diffusion. Tumor delineations based on solely DCE were possible in 7 patients. In 6 of those patients AUC maps demonstrated tumor heterogeneity: a hypointense area with a hyperintense ring. TTP values clearly discriminated the tumor and the healthy pancreas but could not distinguish tumor and the pancreatitis accurately. Conclusion: MR imaging results in a more pronounced tumor contrast than contrast enhanced CT. The addition of quantitative, functional MRI provides valuable, additional information to the radiation oncologist on the spatial tumor extent by discriminating tumor from the healthy pancreas(TTP, DWI) and characterizing the tumor(ADC). Our findings indicate that tumor delineation in pancreatic cancer can greatly benefit from the addition of MRI and especially functional MR techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-05: Dosimetric Comparison of Protocol-Based SBRT Lung Treatment Modalities: Statistically Significant VMAT Advantages Over Fixed- Beam IMRT

Purpose: The purpose of this study is to inter-compare and find statistically significant differences between flattened field fixed-beam (FB) IMRT with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy SBRT. Methods: SBRT plans using FB IMRT and FFF VMAT were generated for fifteen SBRT lung patients using 6 MV beams. For each patient, both IMRT and VMAT plans were created for comparison. Plans were generated utilizing RTOG 0915 (peripheral, 10 patients) and RTOG 0813 (medial, 5 patients) lung protocols. Target dose, critical structure dose, and treatment time were compared and tested for statistical significance. Parameters of interest included prescription isodose surface coverage, target dose heterogeneity, high dose spillage (location and volume), low dose spillage (location and volume), lung dose spillage, and critical structure maximum- and volumetric-dose limits. Results: For all criteria, we found equivalent or higher conformality with VMAT plans as well as reduced critical structure doses. Several differences passed a Student's t-test of significance: VMAT reduced the high dose spillage, evaluated with conformality index (CI), by an average of 9.4%±15.1% (p=0.030) compared to IMRT. VMAT plans reduced the lung volume receiving 20 Gy by 16.2%±15.0% (p=0.016) compared with IMRT. For the RTOG 0915 peripheral lesions, the volumes of lung receiving 12.4 Gy and 11.6 Gy were reduced by 27.0%±13.8% and 27.5%±12.6% (for both, p<0.001) in VMAT plans. Of the 26 protocol pass/fail criteria, VMAT plans were able to achieve an average of 0.2±0.7 (p=0.026) more constraints than the IMRT plans. Conclusions: FFF VMAT has dosimetric advantages over fixed beam IMRT for lung SBRT. Significant advantages included increased dose conformity, and reduced organs-at-risk doses. The overall improvements in terms of protocol pass/fail criteria were more modest and will require more patient data to establish difference trends of more statistical significance.

60 APPLIED LIFE SCIENCES↗

SU-C-17A-02: Sirius MRI Markers for Prostate Post-Implant Assessment: MR Protocol Development

Purpose: Currently, CT is used to visualize prostate brachytherapy sources, at the expense of accurate structure contouring. MRI is superior to CT for anatomical delineation, but the sources appear as voids on MRI images. Previously we have developed Sirius MRI markers (C4 Imaging) to replace spacers to assist source localization on MRI images. Here we develop an MRI pulse sequence protocol that enhances the signal of these markers to enable MRI-only post-implant prostate dosimetric analysis. Methods: To simulate a clinical scenario, a CIRS multi-modality prostate phantom was implanted with 66 markers and 86 sources. The implanted phantom was imaged on both 1.5T and 3.0T GE scanners under various conditions, different pulse sequences (2D fast spin echo [FSE], 3D balanced steadystate free precession [bSSFP] and 3D fast spoiled gradient echo [FSPGR]), as well as varying amount of padding to simulate various patient sizes and associated signal fall-off from the surface coil elements. Standard FSE sequences from the current clinical protocols were also evaluated. Marker visibility, marker size, intra-marker distance, total scan time and artifacts were evaluated for various combinations of echo time, repetition time, flip angle, number of excitations, bandwidth, slice thickness and spacing, fieldof- view, frequency/phase encoding steps and frequency direction. Results: We have developed a 3D FSPGR pulse sequence that enhances marker signal and ensures the integrity of the marker shape while maintaining reasonable scan time. For patients contraindicated for 3.0T, we have also developed a similar sequence for 1.5T scanners. Signal fall-off with distance from prostate to coil can be compensated mainly by decreasing bandwidth. The markers are not visible using standard FSE sequences. FSPGR sequences are more robust for consistent marker visualization as compared to bSSFP sequences. Conclusion: The developed MRI pulse sequence protocol for Sirius MRI markers assists source localization to enable MRIonly post-implant prostate dosimetric analysis. S.J. Frank is a co-founder of C4 Imaging (manufactures the MRI markers)

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 20: CTDI Measurements using a Radiochromic Film-based clinical protocol

The purpose of the study was evaluating accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV-CBCT systems attached to linear accelerators. Energy dependence of Gafchromic XR-QA2 ® film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air-kerma (up to 10 cGy). Calibration curves for each beam quality were created (Film reflectance change Vs. Air-kerma in air). Film responses for same air-kerma values were compared. Film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured and tabulated CTDIvol values were compared. Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. Measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Results presented a mean variation for the same machine and protocol of 2.6%. Variation of film response is within ±5% resulting in ±15% systematic error in dose estimation if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom, as suggested by TG- 111.

07 ISOTOPE AND RADIATION SOURCES↗

A protocol for EBT3 radiochromic film dosimetry using reflection scanning

Purpose: To evaluate the performance of the EBT3 radiochromic film dosimetry system using reflection measurements and to suggest a calibration protocol for precise and accurate reflection film dosimetry. Methods: A set of 14 Gafchromic EBT3 film pieces were irradiated to various doses ranging from 0 to 8 Gy and subsequently scanned using both the reflection and transmission mode. Scanning resolution varied from 50 to 508 dpi (0.5–0.05 mm/pixel). Both the red and green color channels of scanned images were used to relate the film response to the dose. A sensitivity, uncertainty, and accuracy analysis was performed for all scanning modes and color channels. The total uncertainty, along with the fitting and experimental uncertainty components, was identified and analyzed. A microscope resolution target was used to evaluate possible resolution losses under reflection scanning. The calibration range was optimized for reflection scanning in the low (<2 Gy) and high (>2 Gy) dose regions based on the reported results. Results: Reflection scanning using the red channel exhibited the highest sensitivity among all modes, being up to 150% higher than transmission mode in the red channel for the lowest dose level. Furthermore, there was no apparent loss in resolution between the two modes. However, higher uncertainties and reduced accuracy were observed for the red channel under reflection mode, especially at dose levels higher than 2 Gy. These uncertainties were mainly attributed to saturation effects which were translated in poor fitting results. By restricting the calibration to the 0–2 Gy dose range, the situation is reversed and the red reflection mode was superior to the transmission mode. For higher doses, the green channel in reflection mode presented comparable results to the red transmission. Conclusions: A two-color reflection scanning protocol can be suggested for EBT3 radiochromic film dosimetry using the red channel for doses less than 2 Gy and the green channel for higher doses. The precision and accuracy are significantly improved in the low dose region following such a protocol.

60 APPLIED LIFE SCIENCES↗

SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3.2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers.

60 APPLIED LIFE SCIENCES↗