Search NASA⌕ Search

SEARCH · Search NASA

Results for “PULSED LASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Pulsed Airborne Lidar Measurements of Atmospheric CO2 Column Absorption and Line Shapes from 3-13 km Altitudes

We have developed a lidar technique for measuring the tropospheric C02 concentrations as a candidate for NASA's planned ASCENDS mission. Our technique uses two pulsed laser transmitters allowing simultaneous measurement of a C02 absorption line in the 1570 nm band, 02 extinction in the Oxygen A-band and surface height and backscatter. The lidar measures the energy and time of flight of the laser echoes reflected from the atmosphere and surface. The lasers are stepped in wavelength across the C02 line and an 02 line region during the measurement. The receiver uses a telescope and photon counting detectors, and measures the background light and energies of the laser echoes from the surface along with scattering from any aerosols in the path. The gas extinction and column densities for the C02 and 02 gases are estimated from the ratio of the on- and off- line signals via the DIAL technique. Time gating is used to isolate the laser echo signals from the surface, and to reject laser photons scattered in the atmosphere. We have developed an airborne lidar to demonstrate the C02 measurement from the NASA Glenn Lear 25 aircraft. The airborne lidar steps the pulsed laser's wavelength across a selected C02 line with 20 steps per scan. The line scan rate is 450 Hz and laser pulse widths are I usec. The time resolved laser backscatter is collected by a 20 cm telescope, detected by a photomultiplier and is recorded by a photon counting system. We made initial airborne measurements on flights during October and December 2008. Laser backscatter and absorption measurements were made over a variety of land and water surfaces and through thin and broken clouds. Atmospheric C02 column measurements using the 1571.4, 1572.02 and 1572.33 nm C02 lines. Two flights were made above the DOE SGP ARM site at altitudes from 3-8 km. These nights were coordinated with DOE investigators who Hew an in-situ C02 sensor on a Cessna aircraft under the path. The increasing C02 line absorptions with altitudes were evident and comparison with in-situ measurements showed agreements to 6 ppm. This spring we improved the aircraft's nadir window. During July and August 2009 we made 9 additional 2 hour long flights and measured the atmospheric C02 absorption and line shapes using the 1572.33 nm C02 line. Measurements were made at stepped altitudes from 3-13 km over a variety of surface types in Nebraska, Illinois, the SGP ARM site, and near and over the Chesapeake Bay in North Carolina and Virginia. Strong laser signals and clear line shapes were observed at all altitudes, and some measurements were made through thin clouds. The flights over the ARM site were underflown with in-situ measurements made from the DOE Cessna. The Oklahoma and east coast t1ights were coordinated with a LaRC/ITT C02 lidar on the LaRC UC-12 aircraft, a LaRC in~situ C02 sensor, and the Oklahoma flights also included a JPL C02 lidar on a Twin Otter aircraft. Ed Browell and Gary Spiers led the LaRC and JPL teams. More details of the t1ights, measurements and analysis will be described in the presentation.

Abshire, J. B.↗

Computer modeling of pulsed CO2 lasers for lidar applications

The object of this effort is to develop code to enable the accurate prediction of the performance of pulsed transversely excited (TE) CO2 lasers prior to their construction. This is of particular benefit to the NASA Laser Atmospheric Wind Sounder (LAWS) project. A benefit of the completed code is that although developed specifically for the pulsed CO2 laser much of the code can be modified to model other laser systems of interest to the lidar community. A Boltzmann equation solver has been developed which enables the electron excitation rates for the vibrational levels of CO2 and N2, together with the electron ionization and attachment coefficients to be determined for any CO2 laser gas mixture consisting of a combination of CO2, N2, CO, He and CO. The validity of the model has been verified by comparison with published material. The results from the Boltzmann equation solver have been used as input to the laser kinetics code which is currently under development. A numerical code to model the laser induced medium perturbation (LIMP) arising from the relaxation of the lower laser level has been developed and used to determine the effect of LIMP on the frequency spectrum of the LAWS laser output pulse. The enclosed figures show representative results for a laser operating at 0.5 atm. with a discharge cross-section of 4.5 cm to produce a 20 J pulse with aFWHM of 3.1 microns. The first four plots show the temporal evolution of the laser pulse power, energy evolution, LIMP frequency chirp and electric field magnitude. The electric field magnitude is taken by beating the calculated complex electric field and beating it with a local oscillator signal. The remaining two figures show the power spectrum and energy distribution in the pulse as a function of the varying pulse frequency. The LIMP theory has been compared with experimental data from the NOAA Windvan Lidar and has been found to be in good agreement.

Spiers, Gary D.↗

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

Method and circuit for controlling the evolution time interval of a laser output pulse

The invention is a method and circuit for controlling the evolution time interval of a laser output pulse used for making precise spectral measurements. It comprises the means for pumping a laser medium in a resonator that includes a Q-switch and polarizer that act in combination to control the loss in the resonator. A photodiode senses the resulting fluorescence which is applied to a two level Q-switch and polarizer from high to intermediate to substantially zero loss states to control the evolution time interval of the resulting laser output pulse.

Barnes, Norman P.↗

A study of transient stimulated Raman scattering and self-focusing in the picosecond time regime

Two third order processes, stimulated Raman scattering and self-focusing, with picosecond pulses are studied. In the case of transient stimulated scattering, the gain is reduced from the steady state value, and qualitatively new features, such as shortening and delay of the Stokes pulse relative to the laser pulse, appear. These predictions are extended to realistic laser pulses, and experiments confirm all of the theoretical predictions. The self-focusing and frequency broadening of picosecond pulses is studied in the absence of stimulated Raman scattering in several materials with large orientational Kerr constants. Measurements of the relaxation time indicate that the orientational Kerr effect is important in the self-focusing of picosecond pulses. Self-focused filaments are observed to propagate with constant diameters over a distance greater than 10 cm, but disappear before the end of a 20 cm cell. The filaments radiate light continuously along their path and the spectrum of the light shows that the frequency content extends symmetrically for several hundred wave numbers on either side of the laser frequency.

Reintjes, J. F.↗

Single-source pulsed laser-deposited perovskite solar cells with enhanced performance via bulk and 2D passivation

Single-source vapor deposition of halide perovskites has, to date, remained challenging due to the dissimilar volatilities of the precursors, limiting the controlled transfer of multiple elements at once. Here, we demonstrate that pulsed laser deposition (PLD) addresses the rate-control challenges of single-source evaporation, enabling perovskite solar cells with power conversion efficiencies above 19% after passivation. Combining dry mechanochemical synthesis and PLD, we fabricated (Cl-passivated) MA1−xFAxPbI3 films from a single-source target. These films grow on hole-selective self-assembled monolayers, initially forming a thin PbI2-rich layer, which fully converts to perovskite. An oleylammonium iodide (OAmI) post-treatment is then applied to passivate the perovskite’s top surface by forming a 2D perovskite film. Incorporating PbCl2 in the target and applying OAmI-based 2D passivation results in a remarkable 19.7% efficiency for p-i-n perovskite solar cells with enhanced device stability. This highlights the appeal of PLD to fully unlock the potential of single-source vapor-deposited perovskites.

Soto-Montero, Tatiana↗

Droplet field visualization and characterization via digital image analysis

This paper describes techniques that have been developed at JPL for visualization and measurements of droplet fields in a moving airstream. The techniques have been applied to a variety of problems which include simulation of heavy rain conditions in a wind tunnel, engine ingestion of wheel spray, analysis of fuel nozzle sprays and aerodynamic breakup of non-Newtonian liquids. The approach pursued here is direct imaging using a pulsed laser illumination source, followed by digital processing of photographic images. A laser double pulse technique has been used for determination of droplet velocities. Laser induced fluorescence has been used to enhance droplet definition in photographic images. The image processing software developed is capable of distinguishing between out-of-focus and in-focus drops, retaining only the latter for size determination.

Hernan, M. A.↗

Generation of high-power nanosecond pulses from laser diode-pumped Nd:YAG lasers

Simulation results are used to compare the pulse energy levels and pulse energy widths that can be achieved with LD-pumped Nd:YAG lasers for both the pulse-transmission mode (PTM) and pulse-reflection mode (PRM) Q-switching methods for pulse energy levels up to hundreds of microjoules and pulse widths as short as 1 ns. It is shown that high-power pulses with pulse widths as short as 1 ns can be generated with PTM Q-switched in LD-pumped Nd:YAG lasers. With the PRM Q-switching method, pulse widths as short as 2 ns and pulse energy at the level of a few hundred microjoules can also be achieved but require pumping with 8-10-mJ AlGaAs laser diode arrays.

Chan, Kinpui↗

Optimizing a Laser Process for Making Carbon Nanotubes

A systematic experimental study has been performed to determine the effects of each of the operating conditions in a double-pulse laser ablation process that is used to produce single-wall carbon nanotubes (SWCNTs). The comprehensive data compiled in this study have been analyzed to recommend conditions for optimizing the process and scaling up the process for mass production. The double-pulse laser ablation process for making SWCNTs was developed by Rice University researchers. Of all currently known nanotube-synthesizing processes (arc and chemical vapor deposition), this process yields the greatest proportion of SWCNTs in the product material. The aforementioned process conditions are important for optimizing the production of SWCNTs and scaling up production. Reports of previous research (mostly at Rice University) toward optimization of process conditions mention effects of oven temperature and briefly mention effects of flow conditions, but no systematic, comprehensive study of the effects of process conditions was done prior to the study described here. This was a parametric study, in which several production runs were carried out, changing one operating condition for each run. The study involved variation of a total of nine parameters: the sequence of the laser pulses, pulse-separation time, laser pulse energy density, buffer gas (helium or nitrogen instead of argon), oven temperature, pressure, flow speed, inner diameter of the flow tube, and flow-tube material.

Arepalli, Sivaram↗

Water depth measurement using an airborne pulsed neon laser system

The paper presents the water depth measurement using an airborne pulsed neon laser system. The results of initial base-line field test results of NASA airborne oceanographic lidar in the bathymetry mode are given, with water-truth measurements of depth and beam attenuation coefficients by boat taken at the same time as overflights to aid in determining the system's operational performance. The nadir-angle tests and field-of-view data are presented; this laser bathymetry system is an improvement over prior models in that (1) the surface-to-bottom pulse waveform is digitally recorded on magnetic tape, and (2) wide-swath mapping data may be routinely acquired using a 30 deg full-angle conical scanner.

Hoge, F. E.↗

6 um Pulsed OP-GaAs OPO Laser for Unambiguous Water Ice Detection on the Moon and Other Planetary Bodies

NASA demands a laser transmitter for planetary remote sensing to detect water-ice on the Moon and other planetary bodies. Based on the measurement of the Moon Mineralogy Mapper (M3) instrument, the discovery of water ice on the Moon was acclaimed, but the measurement is disputed because OH- and/or H2O-bearing materials share the absorption line around 3 μm wavelength. Lunar Flashlight, another mission project exploring the surface of Moon which will be launched later this year, enables to map the minerals on dark area of the Moon, but could not resolve the above-mentioned ambiguity. The absorption of 6.08 μm light is uniquely associated with the bending resonance of H2O since there is no comparable vibration in confounding OH-bearing materials. 6.08 μm laser between the atmospheric windows: middle-wave infrared (3-5 μm) and long-wave infrared (8-12 μm) has not been commercially available. Our approach is a Q-switched Ho:YLF laser pumped the orientation-pattern Gallium Arsenide optical parametric oscillator (OP-GaAs OPO) for generating high-energy laser pulses at the wavelength of 6.08 μm. In the current design, a 1.94 μm Tm:fiber is used as the pump source. In the compact design, a 1.94 μm laser diode will replace the Tm:fiber laser as the pump source. We will combine this proposed mid-infrared laser with the latest HgCdTe avalanche photodiode (APD) array to design a lidar for detecting water ice on the Moon and Mars from their respective orbits, enabling novel science and in-situ resource utilization. Our instrument is an enabling technology aboard the Artemis program and others.

mid-infrared laser↗

A study of compressed spatially non-Gaussian optical pulses from mode-locked lasers.

The effect of the grating-induced phase and spatial modulations by multiple transverse modes simultaneously present in mode-locked laser pulses is investigated. Our analysis shows that the dispersions of the grating pair become strongly dependent on wavelength because of the energy exchanges occurring among transverse modes. As a result, the maximum-intensity trace at the output of the grating is shown to be curved and the grating-induced pulse-compression rate is shown to vary significantly across the beam cross section. Also, a discussion is presented relating our analysis to existing experimental data on the wavelength-dependent chirping rates of mode-locked laser beams.

Kim, D. M.↗

Ionization effects in single-shot carrier-envelope phase detection with gas-gap devices

The carrier-envelope phase (CEP) is a key parameter for attosecond waveform control of ultrashort laser pulses. For laser systems with high repetition rates, however, single-shot CEP detection is still challenging. Building on recent findings on phase detection with electric current generation in gases, we show that with an optimized detection method, a long-term stable single-shot phase detection is feasible. We investigate the achievable performance depending on various parameters such as pulse duration, gas pressure, or incident intensity. The latter exhibits a regime where the saturation of the ionization process boosts the phase sensitivity of the signal, which is elucidated by numerical calculations.

47 OTHER INSTRUMENTATION↗

Noncontact Acousto-Ultrasonics for Material Characterization

A NdYAG 1064 nm, laser pulse was employed to produce ultrasonic waves in specimens of SiC/SiC and SiC/Ti 6-4 composites which are high temperature materials of interest for aerospace applications. Air coupled transducers were used to detect and collect the signals used for acousto-ultrasonic analysis. Conditions for detecting ultrasonic decay signals were examined. The results were compared to those determined on the same specimens with contact coupling. Some non-contact measurements were made employing conventional air focused detectors. Others were performed with a more novel micromachined capacitance transducer. Concerns of the laser-in technology include potential destructiveness of the laser pulse. Repeated laser pulsing at the same location does lead to deterioration of the ultrasonic signal in some materials, but seems to recover with time. Also, unlike contact AU, the frequency regime employed is a function of laser-material interaction rather than the choice of transducers. Concerns of the air coupled-out technology include the effect of air attenuation. This imposes a practical upper limit to frequency of detection. In the case of the experimental specimens studied ultrasonic decay signals could be imaged satisfactorily.

Kautz, Harold E.↗

A description of the lunar ranging station at McDonald Observatory.

The equipment of this station which has been in operation since the deployment of the first corner reflector by the Apollo 11 astronauts. The McDonald 2.7-m telescope is used for both transmission and reception of pulsed ruby laser light during three 45-minute daily laser runs about three weeks in a month. The present laser pulse width, timing system, calibration procedures, and signal levels are designed to achieve ranging with an accuracy to 1 nanosecond. The data rates obtained since September, 1970, are consistent with the scientific commitments of the lunar ranging program. Most of the over 200 acquisitions obtained have an accuracy to better than plus or minus 30 cm. Details of the telescope matching optics, guiding and timing equipment, and calibration procedures are discussed. Representative lunar range data are included.

Silverberg, E. C.↗

Exploratory laser experiments

Experiments are described which were undertaken to explore the application of various dye laser methods for generating laser pulses which could be tuned over H2O absorption lines in the visible and near infrared. Specific topics discussed include: operation of a long pulse dye laser with a tunable, narrow band output at high energies near the 5915 A water vapor absorption bands; assembly and operation of a short duration dye laser near the 5915 A water vapor absorption bands; construction of a dye laser to be pumped to operate in the red and near infrared; and preliminary studies of the beam divergence of the output of the a laser-pumped system. Results are summarized.

Source record↗

Performance characteristics and statistics of a laser initiated microdetonator

The test results of 320 units of the laser initiated microdetonator are summarized. The commercially fabricated units used a lead styphnate/lead azide/HMX (1 mg/17.5 mg/13.5 mg) explosive train design contained in a miniature aluminum can and completed with a glass-metal seal window. The test parameters were the high and low laser energy, high and low temperature, laser pulse duration, laser wavelength and nuclear radiation (5 x 10 to the 6th rads of 1 MeV gamma ray). The performance parameters were the laser energy for ignition and the actuation response time. Included also is a description of the development of a flexible, continuously advanced train of explosive devices by using the units, miniature optics and fiber optics.

Yang, L. C.↗

Performance characteristics of a laser initiated microdetonator

The test results of 320 units of a laser initiated microdetonator are summarized. The commercially fabricated units used a lead styphnate/lead azide/HMX (1 mg/13.5 mg) explosive train design contained in a miniature aluminum can that was capped with a glass-metal seal window. The test parameters were the laser energy, temperature, laser pulse duration, laser wavelength and nuclear radiation (5,000,000 rad of 1 MeV gamma rays). The performance parameters were the laser energy for ignition and the actuation response time.

Yang, L. C.↗