Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Component-based SHGC determination of BIPV glazing for product comparison

Building-integrated photovoltaic (BIPV) systems are intrinsically designed to generate electricity and to provide at least one building-related function. When BIPV modules act as glazing products in windows, skylights or curtain walls, their ability to control the transmission of solar energy into the building must be characterised by a Solar Heat Gain Coefficient (SHGC) or g value (also known as Total Solar Energy Transmittance – TSET – or “solar factor”). For the comparison of BIPV glazing products consisting of one PV laminate and possibly further, conventional glazing layers separated by gas-filled cavities, the procedures documented in international standards for architectural glazing (e.g. ISO 9050 and EN 410) form a suitable starting point. Easily implemented modifications to these procedures are proposed to take both optical inhomogeneity (if relevant) and extraction of electricity from BIPV glazing units into account. Geometrically complex glazing and shading devices, and light-scattering glazing layers, are outside the scope of the proposed methodology; SHGC determination for obliquely incident solar radiation is also excluded. For these cases, the experimental calorimetric approach documented in [ISO 19467:2017; ISO 19467-2:2021] is recommended. The paper also presents results and conclusions from an implementation exercise and sensitivity study carried out by participants of the IEA-PVPS Task 15 on BIPV. The cell coverage ratio in the PV laminate, the thermal resistance offered by the glazing configuration, the choice of boundary conditions and the effect of extracting electricity were all identified as parameters which significantly affect the SHGC value determined for a given type of BIPV glazing. A practicable approach to accommodate the great variety of dimensions typical for BIPV glazing is also proposed. These findings should pave the way for modifying the existing component-based standards for architectural glazing to take the specific features of BIPV glazing into account.

14 SOLAR ENERGY↗

Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces

Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Cyber-Attack Detection for Active Neutral Point Clamped (ANPC) Photovoltaic (PV) Converter using Kalman Filter

With the upgrading of communication technology, cyber threats to power converters are increasing. In this paper, a model-based cyber-attack detection methodology is proposed for the interleaved Active neutral point clamped (ANPC) Photovoltaic (PV) converter. The proposed methodology identifies cyber-attacks using two estimations based on the Kalman filter and the state-space model of the ANPC PV converter. The residual between the two estimations is analyzed from a statistical perspective. Based on the Cumulative Sum (CUSUM) Control Chart, the standard errors shift of the residual is used to identify cyber-attacks. Besides, to validate the feasibility of the proposed methodology, several conditions are considered in the simulation, including white noise in the sensor, irradiance variation, and cyber-attacks in the PV converter. Furthermore, the simulation result demonstrates the proposed method can identify cyber-attacks in the ANPC PV converter.

14 SOLAR ENERGY↗

Novel stochastic methods to predict short-term solar radiation and photovoltaic power

Solar forecasting has evolved towards becoming a key component of economical realization of high penetration levels of photovoltaic (PV) systems. This paper presents two novel stochastic forecasting models for solar PV by utilizing historical measurement data to outline a short-term high-resolution probabilistic behavior of solar. First, an uncertain basis functions method is used to forecast both solar radiation and PV power. Three possible distributions are considered for the uncertain basis functions - Gaussian, Laplace, and Uniform distributions. Second, stochastic state-space models are applied to characterize the behaviors of solar radiation and PV power output. A filter-based expectation-maximization and Kalman filtering mechanism is employed to recursively estimate the system parameters and state variables. This enables the system to accurately forecast small as well as large fluctuations of the solar signals. The introduced forecasting models are suitable for real-time tertiary dispatch controllers and optimal power controllers. The PV forecasting models are tested using solar radiation and PV power measurement data collected from a 13.5 kW PV panel installed on the rooftop of our laboratory. Furthermore, the results are compared with standard time series forecasting mechanisms and show a substantial improvement in the forecasting accuracy of the total energy produced.

14 SOLAR ENERGY↗

FAIRification, Quality Assessment, and Missingness Pattern Discovery for Spatiotemporal Photovoltaic Data

The growth of the photovoltaic market has pushed the demand for power forecasting and performance evaluation for a huge population of PV power plants. Many of these power plants have spatiotemporal coherence that can be utilized for improving model accuracy. We have demonstrated in this paper the FAIRification of spatiotemporal PV time series data. Through the creation of a solar power plant ontology, we propose standards for the naming and structure of metadata used to describe the data from these power plants. Using the structure from this ontology, we have developed both R and Python packages for the automation of the FAIRification process. Going further, we have also developed an R package that automates the analysis of the quality of a data set through the designation of letter grades. To solve the issue of data missingness, we propose the use of St-GNN autoencoders to detect and impute missing values from a data set by utilizing data from power plants nearby.

14 SOLAR ENERGY↗

Real-Time Local Volt/VAR Control Under External Disturbances with High PV Penetration

Volt/var control (VVC) of smart PV inverter is becoming one of the most popular solutions to address the voltage challenges associated with high PV penetration. This work focuses on the local droop VVC recommended by the grid integration standards IEEE1547, rule21 and addresses their major challenges i.e. appropriate parameters selection under changing conditions, and the control being vulnerable to instability (or voltage oscillations) and significant steady state error (SSE). This is achieved by proposing a two-layer local real-time adaptive VVC that has two major features i.e. a) it is able to ensure both low SSE and control stability simultaneously without compromising either; and b) it dynamically adapts its parameters to ensure good performance in a wide range of external disturbances such as sudden cloud cover, cloud intermittency, and substation voltage changes. A theoretical analysis and convergence proof of the proposed control is also discussed. The proposed control is implementation friendly as it fits well within the integration standard framework and depends only on the local bus information. Furthermore, the performance is compared with the existing droop VVC methods in several scenarios on a large unbalanced 3-phase feeder with detailed secondary side modeling.

14 SOLAR ENERGY↗

FAIRification, Quality Assessment, and Missingness Pattern Discovery for Spatiotemporal Photovoltaic Data

The ongoing growth of the photovoltaic market has pushed the demand for power forecasting and performance evaluation for a huge population of PV power plants. Through access to a large number of time series data sets from different power plants, we have found common issues that impede the modeling process. Namely, the time series data are hard to transfer between groups due to differences in variable nomenclature, and the quality of the data sets can vary. We address the issue of variable nomenclature by FAIRifying spatiotemporal PV time series data. Through the creation of a solar power plant ontology, we propose standards for the naming and structure of metadata used to describe the data from these power plants. Using the structure from this ontology, we have developed both R and Python packages for the automation of the FAIRification process. We have also developed an R package that automates the analysis of the quality of a data set through the designation of letter grades. With access to large time series data sets across many power plants, we can utilize spatiotemporal coherence between the sites in order to improve the quality of our data. To solve the issue of data missingness, we propose the use of Spatiotemporal-GNN autoencoders to detect and impute missing values from a data set by utilizing data from power plants nearby.

14 SOLAR ENERGY↗

Role of Energy Storage with Renewable Electricity Generation

Renewable energy sources, such as wind and solar, have vast potential to reduce dependence on fossil fuels and greenhouse gas emissions in the electric sector. Climate change concerns, state initiatives including renewable portfolio standards, and consumer efforts are resulting in increased deployments of both technologies. Both solar photovoltaics (PV) and wind energy have variable and uncertain (sometimes referred to as intermittent) output, which are unlike the dispatchable sources used for the majority of electricity generation in the United States. The variability of these sources has led to concerns regarding the reliability of an electric grid that derives a large fraction of its energy from these sources as well as the cost of reliably integrating large amounts of variable generation into the electric grid. In this report, we explore the role of energy storage in the electricity grid, focusing on the effects of large-scale deployment of variable renewable sources (primarily wind and solar energy).

14 SOLAR ENERGY↗

Role of Energy Storage with Renewable Electricity Generation (Report Summary) (Presentation)

Renewable energy sources, such as wind and solar, have vast potential to reduce dependence on fossil fuels and greenhouse gas emissions in the electric sector. Climate change concerns, state initiatives including renewable portfolio standards, and consumer efforts are resulting in increased deployments of both technologies. Both solar photovoltaics (PV) and wind energy have variable and uncertain(sometimes referred to as 'intermittent') output, which are unlike the dispatchable sources used for the majority of electricity generation in the United States. The variability of these sources has led to concerns regarding the reliability of an electric grid that derives a large fraction of its energy from these sources as well as the cost of reliably integrating large amounts of variablegeneration into the electric grid. In this report, we explore the role of energy storage in the electricity grid, focusing on the effects of large-scale deployment of variable renewable sources (primarily wind and solar energy).

14 SOLAR ENERGY↗

Qualification Plus: Performance and Durability Tests Beyond IEC 61215 (Presentation)

Qualification Plus is an accelerated test protocol and quality management system that gives higher confidence in field performance of PV modules compared with conventional qualification testing. The test sequences are being developed as consensus standards, but the early publication of these tests enables the community to begin benefiting from them sooner.

14 SOLAR ENERGY↗

Streamlining the Bankability Process using International Standards

NREL has supported the international efforts to create a streamlined process for documenting bankability and/or completion of each step of a PV project plan. IECRE was created for this purpose in 2014. This poster describes the goals, current status of this effort, and how individuals and companies can become involved.

14 SOLAR ENERGY↗

Economic Analysis of Integrated Solar Power, Hydrogen Production, and Electricity Markets

Hydrogen is a versatile energy carrier that is used in a wide variety of chemical and industrial processes. Producing hydrogen using electrolysis can enable integration of multiple sectors including electricity, heating, and industrial sectors; however, the cost of producing hydrogen from electrolysis remains a challenge for encouraging greater adoption. To help improve the economics for both solar PV and hydrogen production using electrolyzers, we explore the benefit of combining PV and electrolysis systems. Using the Revenue Operation and Device Optimization Model (RODeO) model, the optimal breakeven hydrogen production cost for six unique market participation configurations is calculated at six candidate locations in California where PV is already installed. Costs include production, storage, and compression in preparation for gaseous delivery trucks. Revenue streams included in the optimization are the sale of hydrogen, Low Carbon Fuel Standard (LCFS) credits, renewable electricity sold to the grid, and Renewable Energy Credits (REC). The costs included are the electricity costs, capital and fixed operation and maintenance cost (FOM) for the electrolyzer, PV, and storage and compression systems as well as taxes and financing costs. In addition, cost reductions are achieved through retail and wholesale electricity use optimization, by which electricity is purchased at the lowest price and sold, if possible, at the highest price. For all locations analyzed, the breakeven hydrogen production cost results show that, in order of decreasing cost, the system configurations are islanded (highest), separated, NEM, retail, hybrid retail/wholesale, and wholesale (lowest). This report also explores other aspects of hydrogen systems including optimal renewable sizing and resulting energy mixture to the electrolyzer, value of renewable premiums, competition with incumbent technologies, cost sensitivity to a variety of parameters.

decarbonized economy↗

Agent-Based Modeling for the Circular Economy: Lessons Learned From Three Case Studies

The circular economy (CE) aims at decoupling human activities from resource use, creating wealth in the process. Recently, many scholars have questioned the link between increased circularity and sustainability, resulting in many methodological approaches being developed for that purpose. This presentation summarizes the insights gained from the application of agent-based modeling (ABM) to study the techno-economic and social conditions promoting circularity and sustainability of three technologies: photovoltaic (PV) modules, hard disk drives (HDDs), and wind blades. Four main categories of agents are defined in the ABM: asset owners, service providers (e.g., refurbishers), recyclers, and manufacturers. Two main CE strategies are represented: lifetime extension (through repair or reuse) and recycling. The developed models start by projecting installed capacities and end-of-life (EOL) quantities. Then the theory of planned behavior - a social psychology model explaining behavior adoption based on attitude, peer influence, and costs - is used to model the asset owners' EOL decision (i.e., landfill, recycle or extend the lifetime of the asset). Then, the quantities of assets flowing to the recycler and service provider agents and quantities of materials flowing to manufacturers are computed. Recyclers' economies of scale are dynamically modeled, and the value generated by the CE strategies for the recyclers, service providers, and manufacturers is computed within the model. When data are available, avoided greenhouse gas emissions resulting from the CE strategies adoption are calculated exogenously from the ABM simulations. Results show that with improved used PV modules warranties, the reuse CE strategy adoption increases from 1% to 23% between 2020 and 2050. Similarly, improved standards could enhance HDDs end-users trust in data-wiping - a prerequisite to reuse - leading to a 3-fold increase in the reuse rate and avoid about 5 million tons of CO2 eq by 2050. Regarding wind blades, 5-15 years lifetime extension could reduce EOL blade quantities by 13%. High costs and logistic issues prevent blades from being recycled in greater quantities. One insight from the case studies is the necessity to have mature secondary markets for reuse to be a viable option. Interestingly, PV reuse is limited by the willingness of PV owners to purchase used modules (on the demand side), while HDDs reuse is constrained by the lack of trust toward data-wiping (limiting the supply of used HDDs). The six limits of the CE concepts presented by Korhonen et al. (2018) are finally used to interpret the results. The HDD case study is an exemplary lock-in, where the first accepted practice (shredding) retains most of the market. The PV results illustrate the technical limitation to reuse, as the growing demand cannot be supplied entirely with used PV modules. The wind case study shows the relevance of clearly defining physical flows - what type of waste should wind blades be considered, how should they be transported and landfilled? - a crucial consideration that also applies to PV modules. Finally, the three case studies highlight the relevance of studying a technology's technical, economic, and market material efficiency potentials altogether and the potential benefit of coupling ABM to life cycle assessment.

agent-based modeling↗

Measurement of the Parity-Violating Asymmetry in Deep Inelastic Scattering at JLab 6 GeV

The parity-violating asymmetry in deep inelastic scattering (PVDIS) offers us a useful tool to study the weak neutral couplings and the hadronic structure of the nucleon, and provides high precision tests on the Standard Model. During the 6 GeV PVDIS experiment at the Thomas Jefferson National Accelerator Facility, the parity-violating asymmetries A{sub PV} of a polarized electron beam scattering off an unpolarized deuteron target in the deep inelastic scattering region were precisely measured at two Q 2 values of 1.1 and 1.9 (GeV/c) 2 . The asymmetry at Q 2 =1.9 (GeV/c) 2 can be used to extract the weak coupling combination 2C 2u - C 2d , assuming the higher twist effect is small. The extracted result from this measurement is in good agreement with the Standard Model prediction, and improves the precision by a factor of five over previous data. In addition, combining the asymmetries at both Q 2 values provides us extra knowledge on the higher twist effects. The parity violation asymmetries in the resonance region were also measured during this experiment. These results are the first A PV data in the resonance region beyond the Δ (1232). They provide evidence that the quark hadron duality works for A PV at the (10-15)% level, and set constraints on nucleon resonance models that are commonly used for background calculations to other parity-violating electron scattering measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Degradation in PV Encapsulant Transmittance: Results of the First PVQAT TG5 Study

Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. The latest versions of the safety and qualification apply ~40 - ~160 days cumulative dose of the AM1.5G total UV radiation. Essential information that might be used to screen encapsulation through product lifetime also remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a higher fidelity, more rigorous UV weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens were examined at 10 institutions using a variety of indoor chambers (including Xenon, UVA-340, and high pressure mercury light sources). Specimens were artificially weathered for 180 cumulative days at pre-designated accelerated test conditions. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.

14 SOLAR ENERGY↗

A Spatially Resolved Evaluation of Accelerated Environmental Aging on Emerging Polypropylene-Based Photovoltaic Backsheets Using Raman Spectroscopy

For this work, accelerated aging was used to assess environmental degradation in emerging co-extruded polypropylene (PP)-based backsheets under three different environmental conditions (65°C/20% relative humidity (RH), 75°C/20% RH, and 75°C/50% RH). Although differential scanning calorimetry did not measure crystallinity changes with exposure, spatially resolved Raman spectroscopy identified crystallinity increases in the core layer of aged samples, indicating a heterogeneous postcrystallization process. The Raman results were in agreement with synchrotron-based microfocused wide-angle X-ray scattering measurements. Cross-sectional nanoindentation was used to correlate localized crystallinity shifts with changes in Young's modulus. A similar trend was found where increased modulus was measured in the core layer, supporting the relationship between modulus and crystallinity. Finally, dielectric characterization was used to assess the impact of these material property changes on performance. While changes in the backsheet material properties and dielectric performance were observed with accelerated aging, these shifts generally equilibrated with time, indicating overall stability in response to environmental stressors. Additionally, the identified heterogeneous material property changes indicate that spatially resolved crystallinity measurements may be a valuable early failure indicator to be used in the assessment of PV backsheet long-term durability.

36 MATERIALS SCIENCE↗

Direct Current Arc-Flash Hazards of Solar Photovoltaic Systems

An arc-flash is a rapid release of thermal energy, pressure waves, and electromagnetic interference from a high-power electrical system, caused by such events as unintentional shorting or equipment malfunction. Arc-flashes are hazardous to people and equipment. Incident energy (IE) is a means of quantifying the degree of thermal hazard posed by an arc-flash event. The calculated IE value dictates what level of personal protective equipment (PPE) workers are required to wear when servicing equipment. Overly burdensome PPE may increase a worker’s discomfort and decrease dexterity, which could lead to unintentional shorting, while inadequate PPE also comes with increased safety risks. The majority of arc-flash research to date has focused on alternating current (ac) systems. For example, IE calculations and PPE for ac systems are relatively well understood and have been applied across many equipment types and voltages. IE calculation methodologies in ac systems are backed by a wide range of industry tests and are included in Institute of Electrical and Electronics Engineers (IEEE) and National Fire Protection Association (NFPA) standards. However, very little is known about direct current (dc) arc-flash and its hazards. This is a significant knowledge gap, as an increasing number of dc systems are being deployed: solar photovoltaic (PV) plants, battery storage, and electric vehicles and their charging infrastructure. The dc arc-flash hazard publications are rooted primarily in theory, and their IE calculation methods contradict each other. Insufficient knowledge and data are preventing the formation of industry consensus and standards around dc arc-flash hazard assessment. Here, this white paper highlights the current status and research opportunities for assessing arc-flash hazards in dc systems, with a focus on PV plants. The nonlinear current-voltage characteristics of PV modules make them unique in comparison to other linear dc sources, such as batteries. Also, PV equipment has rapidly evolved from 600 Vdc to 1,500 Vdc (in the United States), increasing potential arc-flash hazards. The operating regime of a PV-array within its I-V characteristic curve during an arc-flash event and the sustainability of arc-flash events in a utility-scale PV plant need to be investigated. Arc-flash experiments on a 1-MWdc nameplate capacity utility-owned ground-mount photovoltaic plant suggest that the PV array acts as a constant-current supply with currents near the short-circuit portion of the I-V characteristic curve of the array, with median arc voltage as 1/3 of the rated voltage. Various engineering software packages (CYME7 by EATON, PTW by SKM, ArcFlash™ by EasyPower, ETAP, and so on) have started offering dc arc-flash calculation features to estimate the risk of arc-flash in dc and PV systems. However, they are reliant on the same simplified arc-flash models, which contradict each other due to differences in assumptions such as characteristics of the power source, arc current, voltage and impedance, arc-operating regime, and so on. Physical arc-flash testing and improved physics-based modeling with correct assumptions representing practical scenarios are two methods to improve understanding and quantify the risks associated with dc arc-flash hazards. The results would inform development of a more accurate calculation procedure for IE and proper PPE levels.

14 SOLAR ENERGY↗