Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

AquaPV: Foundational Analysis and Industry Guidance on Floating PV Results

This dataset contains results of the technical potential analysis of floating photovoltaics (FPV) on federally owned or permitted reservoirs in the United States. Estimates of the area of reservoirs that is technically feasible for FPV development are provided for reservoirs that are owned by the US Army Corps of Engineers or the US Bureau of Reclamation, or are associated with hydropower dams licensed by the Federal Energy Regulatory Commission. Other associated data are included, such as estimates of the potential evaporative losses of FPV development, and whether the waterbody is associated with an energy community or disadvantaged community that could qualify it for investment or production tax credits. Data is provided both as a spreadsheet and in a geospatial format including the waterbody geometries. Please read the included readme for more detailed field definitions.

area↗

Heavy Oil Polymer EOR in the Challenging Alaskan Arctic - It Works!

Under co-sponsorship of the US Department of Energy and Hilcorp Alaska LLC the first ever polymer field pilot commenced on 8/28/2018 in the Schrader Bluff heavy oil reservoir at the Milne Point Field on Alaska North Slope (ANS). The primary objective of the pilot is to prove the efficacy of polymer Enhanced Oil Recovery (EOR) to unlock the vast heavy oil resources on ANS. More than two and half years after startup, the polymer injection, supporting laboratory experiments and simulation studies steadily continue. The pilot started injecting hydrolyzed polyacrylamide (HPAM), at a concentration of 1,750 ppm to achieve a target viscosity of 45 cP, into the two horizontal injectors in the flood pattern. Production is monitored in the two horizontal producers. Based on laboratory measurements of polymer viscosity at reservoir conditions, the team decided to reduce polymer concentration to 1,200 ppm since July 2020 in an effort to control injection pressure and optimize polymer utilization. Quality control (QC) on the field ensures uniform polymer solution properties. Representative rock and fluid systems and test conditions are utilized in the corefloods on polymer retention, effect of injection water salinity, polymer loading, and their combinations on oil recovery. A history matched reservoir simulation model for forecasting oil recovery was developed on the basis of all the available field data. Field concerns related to the post-polymer breakthrough impact on flow assurance is addressed via specialized laboratory tests. Notwithstanding early operational disruptions and hydration issues, continuous polymer injection in both injectors has been achieved. To date, 950,000 lbs of polymer or 2 million barrels of polymer solution, equating to 13% of total pore volume (PV), has been placed in the flood pattern, serving as an effective indicator of adequate polymer injectivity. So far, the success of polymer EOR is evident from drastically reduced water cut in the producers, an estimated incremental 1,000 bopd over waterflood, and a favorable polymer utilization of 1.7 lbs/barrel of incremental oil. Polymer breakthrough was observed 26 months after the start of polymer injection. Main observations from corefloods are unusually high polymer retention values in some cases and a positive response to low salinity water. Although the heterogeneity in the flood pattern and exceptionally low water cut pose some challenges, persistent novel and justifiable simulation approaches have resulted in a robust history matched model. Experimental results on produced fluids treatment provide operational guidance for improved oil-water separation and mitigation of heater tube fouling. The ongoing success of the pilot is a key indicator of bringing the team ever closer to meeting the project’s primary objective. The encouraging results of the pilot is one of the drivers that has provided the impetus to apply polymer EOR throughout the Milne Point Field, which would increase oil recovery and extend the economic life of the Trans Alaska Pipeline System. The scientific knowledge, including the many lessons learned from this pilot also has referential value for other potential heavy oil EOR projects throughout the world. The collected data, operational lessons learned, and the overall success of the pilot are summarized in the paper.

None, None↗

Tropopause Structure as Revealed by the Satellite Water Vapor Channel During STRAT: The Relationship to Small and Mesoscale Structure as Shown in Aircraft Measurements

This paper examines the use of 6.5 micron geostationary satellite imagery during the Stratospheric Radiation And Transport (STRAT) field mission, the first pha:ie of which is during May, 1995. The 6.5 micron imagery is being us4!d to define the horizontal structure of areas where the tropopause is particularly low. Regions of high PV on, say, a 350K surface have been shown to coincide roughly with regions of enhanced radiance. These regions of enhanced 6.5 micron radiance coincide with dryness in the 5-10 km region, since the dryness enables radiation from lower (and warmer) levels to penetrate through the atmosphere into space. Such dryness is associated with downward penetrations of dry stratospheric, high potential vorticity air. We explore the extent to which such regions of high radiance are related to stratospheric intrusions into the troposphere as observed by aircraft data.

Pfister, Leonhard↗

Bringing Solar Energy to Low- and Moderate-Income Communities

The U.S. solar photovoltaics (PV) industry has taken off over the past decade, but without deliberate action low- and moderate-income communities could be left behind. Key recommendations for policymakers and funders in the renewable energy and community development fields that emerged from this process include the following: • Help to capitalize and support community-based lenders to provide flexible, low-cost, and long- term financing to mission-driven solar projects— including providing guarantees or other forms of credit enhancement. • Provide a grant-in-lieu-of-credits option for the Investment Tax Credit as was done during the last recession. • Develop pools of government and philanthropic support that can complement financing from community-based lenders to complete the capi- tal stack for mission-driven projects, as well as to support education and technical assistance to both consumers and potential project sponsors. • Create a national Renewable Energy Credits pro- gram that includes social equity targets to provide a baseline of support for clean energy generation. • Change utility regulations to remove barriers to low-income solar projects, provide greater certainty for developers, and measure progress toward equity in renewable energy policy implementation.

14 SOLAR ENERGY↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Albedo Measurement of the Terra Pave White Albedo Product: Cooperative Research and Development Final Report

The Terra Pave team is creating an eco-friendly, cost-effective road coating that controls dust and dirt on high-traffic roads near solar field installations to reduce the dirt cover on panels, which lowers energy output. The Terra Pave White Albedo product also has the capability to increase the amount of solar radiation reflected from the ground to the backside of bifacial PV modules, thereby increasing the amount of electricity generated. This work will quantify the amount of solar radiation reflected from the Terra Pave White albedo product by measuring its albedo, which is the ratio of the reflected radiation to the incoming radiation. Albedo is measured with two horizontal pyranometers with one ground-facing and the other sky-facing.

14 SOLAR ENERGY↗

Energy Northwest - Horn Rapids Solar and Storage: An Assessment of Battery Technical Performance

Chartered in 1957 as a joint action agency of the state, Energy Northwest (ENW) is a consortium of 27 public utility districts and municipalities across Washington state. ENW takes advantage of economies of scale and shared services to help utilities run their operations more efficiently and at lower cost, to the benefit of more than 1.5 million customers. ENW develops, owns, and operates a diverse mix of electricity generating resources, including hydro, solar, and wind projects – and the Northwest’s only active nuclear energy facility. These projects provide enough reliable, affordable, and environmentally responsible energy to power more than a million homes each year, and that carbon-free electricity is provided at the cost of generation. The agency continually explores new generation projects to meet its members’ needs. In 2017, as part of the second round of funding from the Washington state Clean Energy Fund, the Washington State Department of Commerce granted up to $3 million in matching funds to develop an estimated $6.5 million project that deployed a 4-MW, 20-acre solar generating array of photovoltaic (PV) panels coupled with a 1 MW/5.5 MWh lithium-iron-phosphate battery energy storage system (BESS) in Richland, Washington. The combination of PV and BESS will provide a predictable, renewable generating source and will also serve as a training ground for solar and battery technicians throughout the nation. The City of Richland will purchase the power from the project and utilize the benefits of the energy storage. The project provides Washington state with its first opportunity to integrate a large-scale solar and storage facility into its clean mix of hydro, nuclear, and wind resources. This first-of-its-kind facility combines solar generation with battery storage and technician training. In 2019, Pacific Northwest National Laboratory (PNNL) worked with ENW to assess the integrated PV and BESS in representative use cases that could benefit the City of Richland. Between March and May 2022, extensive testing was conducted, and the results were used to assess the technical performance of the BESS subjected to actual field operations. Both reference performance and use case tests were performed: (A) Reference performance tests assess the general technical capabilities of the BESS, such as energy capacity, round-trip efficiency (RTE), ramp rate, and signal tracking capability. These are the first tests performed (baseline), and they are repeated after use case tests (post cycle). A standardized U.S. Department of Energy (DOE) energy storage performance protocol was used to characterize the BESS, including representative duty cycle profiles, test procedure guidance, and calculation guidance for determining key characteristics. (B) Use case tests examine the performance of the BESS for specific use cases using duty cycles developed by PNNL in collaboration with ENW. Five use cases were selected for testing: 1) demand charge reduction, 2) load shaping, 3) transmission charge reduction, 4) Volt-VAR service, and 5) outage mitigation. The use case duty cycles were developed based on utility and site-specific characteristics in addition to the technical characteristics and physical capabilities of the BESS. Use case tests were performed between the baseline and post cycle tests. This report describes the BESS and its components, presents testing and performance analysis results, and shares key insights and lessons learned from this project. Outcomes of the tests and analyses will help ENW understand the performance of the Horn Rapids BESS in its current state and design appropriate operational strategies for this and other BESSs over the long term.

14 SOLAR ENERGY↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Multimode Characterization Approach for Understanding Cell-Level PV Performance and Degradation

Cell-level degradation processes impact the economic viability and large-scale deployment prospects for both established and emerging photovoltaic (PV) technologies. This project addresses the need to develop experimental and device-modeling approaches for studying cell-level degradation processes in photovoltaic (PV) devices using a variety of characterization techniques that provide access to complementary material and device properties. Our results demonstrate that by coupling characterization results with device modeling it is possible to develop comprehensive understanding of processes leading to performance limitations and degradation. This project developed a suite of novel measurement techniques including pulsed-light-bias operando X-ray and photoelectron spectroscopy (popXPS), light-biased scanning microwave impedance microscopy (sMIM), and near-field transport imaging (TI). In addition, operando characterization methodologies and in situ stressing capabilities have been developed and applied for techniques including electron-beam-induced current (EBIC), cathodoluminescence (CL), and Kelvin probe force microscopy (KPFM). Device-physics models were developed and applied to simulate correlative, multi-mode measurements to extract material and device parameters that control performance degradation. These characterization and modeling techniques were applied in a multi-mode approach to probe cell-level degradation mechanisms in Cd(Se,Te) and hybrid perovskite PV devices. Together these efforts contribute to foundational PV degradation science by establishing a framework for understanding PV performance degradation at the cell level and benefit the U.S. PV industry by providing resources in the form of novel experimental capabilities, knowledge gained, and available expertise that can accelerate research and development of improved PV device materials and architectures. The project provided a comprehensive understanding of degradation in baseline Cd(Se,Te) solar cells provided by our collaborators at Colorado State University (CSU). EBIC and CL-based measurements and revealed unusual collection and recombination profiles in these devices, which underwent significant changes with during stressing. KPFM and operando XPS measurements showed that device stressing permanently alters energy-band alignments at the (Mg,Zn)O/Cd(Se,Te) interface, which in turn account for an observed loss in fill factor. Studies on hybrid perovskite devices were hampered to a significant extent by delays related to the pandemic. Nevertheless, a set of hybrid perovskite devices (supplied through an NREL-industry partnership) were stress tested and characterized with techniques including EBIC, sMIM, popXPS/popUPS and optically excited TI. Available results from these measurements informed the device modeling effort and suggest that defects and related band offsets at the C60/LiF/hybrid perovskite interface are the primary source of degradation in these devices.

14 SOLAR ENERGY↗

Simulating Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on compliant solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within single-axis, solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare time series and statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability and the differences between positive and negative tilt angles.

fluid↗

A Simulation and Optimization Framework for Managing Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability as measured by both acceleration and deformation, focusing on the stability differences between positive and negative tilt angles.

fluid structure interaction↗

Solar Transposition Modeling via Deep Neural Networks With Sky Images

This article presents a notable advance toward the development of a new method of increasing the single-axis tracking photovoltaic (PV) system power output by improving the determination and near-term prediction of the optimum module tilt angle. The tilt angle of the plane receiving the greatest total irradiance changes with Sun position and atmospheric conditions including cloud formation and movement, aerosols, and particulate loading, as well as varying albedo within a module's field of view. In this article, we present a multi-input convolutional neural network that can create a profile of plane-of-array irradiance versus surface tilt angle over a full 180° arc from horizon to horizon. As input, the neural network uses the calculated solar position and clear-sky irradiance values, along with sky images. The target irradiance values are provided by the multiplanar irradiance sensor (MPIS). In order to account for varying irradiance conditions, the MPIS signal is normalized by the theoretical clear-sky global horizontal irradiance. Using this information, the neural network outputs an N -dimensional vector, where N is the number of points to approximate the MPIS curve via Fourier resampling. The output vector of the model is smoothed with a Gaussian kernel to account for error in the downsamping and subsequent upsampling steps, as well as to smooth the unconstrained output of the model. Furthermore, these profiles may be used to perform near-term prediction of angular irradiance, which can then inform the movement of a PV tracker.

42 ENGINEERING↗

Cyber-Secure and Safe Operation of Solar Photovoltaic Power Distribution Systems

Solar photovoltaic (PV)-rich power distribution systems are networked Cyber-Physical Systems (CPS). These are control systems where multiple computing nodes and diverse intelligent agents interact with the physical world in real-time. However, the presence of networked components renders them vulnerable to potential cyber-attacks, cyber-intrusions, and other malicious events. This is because these systems depend on the measurements reported from their heterogeneous sensors. This makes them vulnerable to potential cyber-attacks where malicious agents can compromise the sensors or the communication networks carrying the sensor measurements. This paper proposes a novel methodology for enhancing the cyber-security and cyber-resilient post-attack safe operation of solar PV-rich power distribution systems against potential cyber-attacks through the Dynamic Watermarking (DW), using online system identification. The resiliency of the proposed technique is tested and validated with several attack scenarios on both a lab-scale 3kW grid-connected PV inverter and a Hardware-in-the-Loop (HiL) system. The proposed approach can be applied to other types of power distribution systems to enhance their cyber-secure and cyber-resilient safe operation. This paper thereby contributes to the field of cyber-security of Cyber-Physical Energy Systems (CPES).

Kim, Jaewon↗

Development of Fixtures and Methods to Assess the Durability of Balance of Systems Components

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were, therefore, examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using a benchtop prototype fixture to identify the most influential environmental stressors on BoS components as well as the effect of external mechanical perturbation. The prototype fixture was used to develop a perturbation capability for future use in the combined-accelerated stress testing chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 °C from ~40 °C) and a different failure mode (arcing at the metal pins rather than overheating of the fuse filament) were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (measured for static specimens, with failure occurring in the fuses) to 15 A (for tests with mechanical perturbation, with failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy). Chemical composition analysis included energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

14 SOLAR ENERGY↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗

Seasonal Variability of Saturn's Tropospheric Temperatures, Winds and Para-H2 from Cassini Far-IR Spectroscopy

Far-IR 16-1000 micrometer spectra of Saturn's hydrogen-helium continuum measured by Cassini's Composite Infrared Spectrometer (CIRS) are inverted to construct a near-continuous record of upper tropospheric (70-700 mbar) temperatures and para-H2 fraction as a function of latitude, pressure and time for a third of a saturnian year (2004-2014, from northern winter to northern spring). The thermal field reveals evidence of reversing summertime asymmetries superimposed onto the belt/zone structure. The temperature structure is almost symmetric about the equator by 2014, with seasonal lag times that increase with depth and are qualitatively consistent with radiative climate models. Localised heating of the tropospheric hazes (100-250 mbar) create a distinct perturbation to the temperature profile that shifts in magnitude and location, declining in the autumn hemisphere and growing in the spring. Changes in the para-H2 (f(sub p)) distribution are subtle, with a 0.02-0.03 rise over the spring hemisphere (200-500 mbar) perturbed by (i) low-f(sub p) air advected by both the springtime storm of 2010 and equatorial upwelling; and (ii) subsidence of high-f(sub p) air at northern high latitudes, responsible for a developing north-south asymmetry in f(sub p). Conversely, the shifting asymmetry in the para-H2 disequilibrium primarily reflects the changing temperature structure (and hence the equilibrium distribution of f(sub p)), rather than actual changes in f(sub p) induced by chemical conversion or transport. CIRS results interpolated to the same point in the seasonal cycle as re-analysed Voyager-1 observations (early northern spring) show qualitative consistency from year to year (i.e., the same tropospheric asymmetries in temperature and f(sub p)), with the exception of the tropical tropopause near the equatorial zones and belts, where downward propagation of a cool temperature anomaly associated with Saturn's stratospheric oscillation could potentially perturb tropopause temperatures, para-H2 and winds. Quantitative differences between the Cassini and Voyager epochs suggest that the oscillation is not in phase with the seasonal cycle at these tropospheric depths (i.e., it should be described as quasi-periodic rather than 'semi annual'). Variability in the zonal wind field derived from latitudinal thermal gradients is small (less than 10 m/s per scale height near the tropopause) and mostly affects the broad retrograde jets, with the notable exception of large variability on the northern flank of the equatorial jet. The meridional potential vorticity (PV) gradient, and hence the 'staircase of PV' associated with spatial variations in the vigour of vertical mixing, has varied over the course of the mission but maintained its overall shape. PV gradients in latitude and altitude are used to estimate the atmospheric refractive index for the propagation of stationary planetary (Rossby) waves, predicting that such wave activity would be confined to regions of real refractivity (tropical regions plus bands at 35-45 in both hemispheres). The penetration depth of these regions into the upper troposphere is temporally variable (potentially associated with stratification changes), whereas the latitudinal structure is largely unchanged over time (associated with the zonal jet system).

Fletcher, Leigh N.↗

Interoperable, Inverter-Based Distributed Energy Resources (DERs) Enable 100% Renewable and Resilient Utility Microgrids

Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.

battery energy storage systems↗