Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Upstream Extraction of Tellurium from Copper Concentrates

A major barrier to increasing CdTe PV module production is the availability of tellurium (Te), an element necessary to manufacture CdTe PV cells that currently has a very limited supply. Most Te is obtained from ore extracted for copper mining, but the current processing methods only extract 3-4% of the available Te in this ore, with the rest being discarded during other processing steps. This project aims to increase Te supply by developing an innovative extraction method that will recover more Te from the copper ore earlier in the process. This method will also extract toxic elements like antimony and arsenic, making the copper mining process more environmentally friendly.

14 SOLAR ENERGY↗

Updates to the Instant Online PV LCOE Calculator Tool

Levelized cost of energy (LCOE) is an important metric for techno-economic analysis of PV modules, systems, and performance. An NREL team within DuraMAT has developed a simplified PV-specific LCOE calculator as an alternative to the NREL System Advisor Model (SAM) for applications that do not have the degree of detail required by SAM. This webinar will review recent data and new features that have been added to the simplified calculator this year, including breakeven buttons, commercial system options, and inverter loading ratios. It will also review the structure of the source code on GitHub, how to edit a local version of the calculator, and walk through some example use cases for the calculator.

calculator↗

Annual Supply Chain for Photovoltaics (ASC-PV) in the United States: 2024 in Review

This report analyzes U.S. PV and BESS supply chains and costs in 2024, for PV module and battery technologies, structural and electrical balance of system (BOS) components, as well as PV recycling. The report concludes with an analysis of technology installation trends, government support for domestic manufacturing, manufacturing jobs, and the domestic content of PV systems installed in the United States in 2024.

14 SOLAR ENERGY↗

Durable Module Materials (DuraMAT) Consortium (Final Technical Report)

The DuraMAT Consortium brings together DOE national lab and university research capabilities with the photovoltaic (PV) and supply-chain industries to accelerate a sustainable, just, and equitable transition to zero carbon electricity generation by 2035 through our five core objectives: development of a central data resource for PV modules, multi-scale and multi-physics modeling, disruptive acceleration science, forensic tools for fielded modules, and materials solutions for more durable, reliable, and resilient modules.

14 SOLAR ENERGY↗

Review of the environmental effects of the Space Station Freedom photovoltaic power module

An overview is provided of the environment in the low Earth orbit (LEO), the interaction of this environment with the Photovoltaic (PV) Power system of the Space Station Freedom is reviewed, and the environmental programs are described that are designed to investigate the interactions of the LEO environment with the photovoltaic power system. Such programs will support and impact the design of the subsystems of the PV module in order to survive the design lifetime in the LEO natural and induced environment.

Nahra, Henry K.↗

Review of the environmental effects on the Space Station Freedom photovoltaic power module

An overview is provided of the environment in the low earth orbit (LEO), the interaction of this environment with the photovoltaic (PV) power system of the Space Station Freedom is reviewed, and the environmental programs are described that are designed to investigate the interaction of the LEO environment with the photovoltaic power system. Such programs will support and impact the design of the subsystems of the PV module in order to survive the design lifetime in the LEO natural and induced environment.

Nahra, Henry K.↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

bifacial↗

Uncertainty Quantification of Bifacial Performance Modeling: Preprint

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Enhancing lifetime, forecasting, and economic benefits of photovoltaic technologies undergoing UV-induced degradation with optical filtering

Ultraviolet-induced degradation (UV-ID) of various PV cell types was analyzed under optical UV filters with different cutoff wavelengths. Cell types studied included interdigitated back contact (IBC), passivated emitter and rear totally diffused (PERT), and heterojunction technology (HJT) based on crystalline Si (c-Si), and metal halide perovskite (MHP) cells. Analyzing degradation rates in two distinct regimes proved beneficial for all cell types. We used empirical linearizing functions ln(t) for c-Si technologies and 2 √t for MHP samples where t is time. These were applied to extrapolate UV-induced degradation over the lifetime of PV modules under various levels of optical UV filtering and used to predict the relative economic benefits for PV power plants. Degradation rates for all technologies were generally faster under the long pass optical filters having shorter cutoff wavelengths transmitting more UV irradiation and at elevated temperatures when testing MHP samples in the range between 60 °C and 90 °C.

14 SOLAR ENERGY↗

Multiple Hail Impact Testing

For resilient energy delivery PV modules and systems must withstand extreme weather events such as hailstorms, which are the leading cause of PV insurance claims. Currently, the industry testing is limited to one strike at a time, but in real hailstorms multiple hail strikes can occur within a fraction of a second. In this project we test if multiple simultaneous or near-simultaneous hail strikes cause more damage than with single hail strike testing.

14 SOLAR ENERGY↗

Bifacial PV System Mismatch Loss Estimation & Parameterization

Non-uniform irradiance on the rear-side of bifacial PV systems can cause additional mismatch loss which may not be appropriately captured in PV energy production estimates and software. We have evaluated several rooftop mounted systems over high albedo reflective roofs. Mismatch losses of up to 2% annual loss for very close-mounted (0.15 m) rooftop systems were found, but losses for high ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically the mean absolute difference of irradiance) to the resulting mismatch loss factor, with a R2 fit better than 0.985. This approximate relationship has been validated by experiments on mismatched PV modules, and provides a basis for fast estimation of bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM.

14 SOLAR ENERGY↗

Bifacial PV System Mismatch Loss Estimation and Parameterization: Preprint

Non-uniform irradiance on the rear-side of bifacial PV systems can cause additional mismatch loss which may not be appropriately captured in PV energy production estimates and software. We have evaluated several scenarios including horizontal single-axis tracking (HSAT) and rooftop mounted systems over high albedo reflective roofs. Mismatch losses of up to 2% annual loss for very close-mounted (0.15 m) rooftop systems were found, but losses for HSAT systems and high ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically the mean absolute difference of irradiance) to the resulting mismatch loss factor, with a R2 fit better than 0.985. This approximate relationship has been validated by experiments on mismatched PV modules, and provides a basis for fast estimation of bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM.

14 SOLAR ENERGY↗

Material characterization of seven photovoltaic backsheets using seven accelerated test conditions

A variety of polymeric backsheet materials can be found in fielded photovoltaic (PV) modules, mostly based on fluoropolymer and polyethylene terephthalate (PET) materials. Cost reduction and sustainability considerations drive the recent development of alternative backsheet materials and designs [1]. In some fielded PV installations, polymeric materials are susceptible to environmental degradation in the form of backsheet cracking. To prevent backsheet degradation that can result in a module failure, thorough laboratory reliability testing is needed. In this report we studied the durability of seven commercial and experimental PV backsheets through accelerated stress testing using seven photolytic, hygrometric, and custom tests with the goal to understand if novel fluoropolymer-free backsheets are sufficiently environmentally durable to be commercialized. We divided the mechanisms observed during aging into two categories: core degradation and surface degradation. Although core degradation due to hydrolysis was observed in all commercial PET-, and polyamide (PA)-based backsheets aged with 85 degrees C/85% relative humidity, this test is unlikely to be field relevant. Photo-oxidative reactions on the exposed surface during UV weathering affected all seven backsheets regardless of the outer layer polymer material and additives. This degradation was limited to the outermost micrometers of the surface, except for backsheets containing PA-12, which resulted in surface cracking. A custom test combining UV with water spray caused the most severe backsheet degradation, including surface erosion and loss of insulating properties in polyolefin (PO)- and PA-based backsheets. This highlights the importance of combined accelerated stress testing to screen for complex backsheet degradation mechanisms. We also showed that, with material and design optimization, coextruded experimental PO-based backsheets have the potential to be a durable alternative to commercial PET- and fluoropolymer-based PV backsheets.

14 SOLAR ENERGY↗

BACKFLIP: A Comparison of Emerging Non-Fluoropolymer-Based, Co-Extruded PV Backsheets to Industry-Benchmark Technologies

As the photovoltaic (PV) industry is rapidly expanding around the world, there has been an increasing interest in extending the lifespan of PV modules. Concern has also emerged regarding the recyclability of modules and their component materials, including fluoropolymer-based backsheets. Laminated polyethylene-terephthalate (PET) core backsheets have traditionally been used in the PV industry, but new, co-extruded polyolefin (PO) backsheets show promise as an improved alternative. Mini-module and coupon samples of seven different backsheets (made of layers including contemporary PET and fluoropolymers, novel PO, and polyamide (PA) materials) were run through hygrometric- or UV photolytic-accelerated aging to identify and better understand each material’s degradation modes and the backsheets’ field reliability. In addition to the artificial aging, the natural weathering methods used in this study are described. The comprehensive set of chemical, mechanical, and structural characterizations at intermittent read points in this study is presented, including: visual appearance and color; gloss; mechanical tensile testing; I-V performance; electroluminescence (EL) imaging; dielectric breakdown; FTIR-chemical structure; X-ray-polymer structure (WAXS); and DSC-crystalline content. After 4000 h of aging, a strong correlation occurs between initial physical characteristics (mechanical tensile test) and operating performance (EL and I-V characteristics).

41 EE - Solar Energy Technologies Office (EE-4S)↗

BACKFLIP: A Comparison of Emerging Non-Fluoropolymer-Based, Co-Extruded PV Backsheets to Industry-Benchmark Technologies

As the photovoltaic (PV) industry is rapidly expanding around the world, there has been an increasing interest in extending the lifespan of PV modules. Concern has also emerged regarding the recyclability of modules and their component materials, including fluoropolymer-based backsheets. Laminated polyethylene-terephthalate (PET) core backsheets have traditionally been used in the PV industry, but new, co-extruded polyolefin (PO) backsheets show promise as an improved alternative. Mini-module and coupon samples of seven different backsheets (made of layers including contemporary PET and fluoropolymers, novel PO, and polyamide (PA) materials) were run through hygrometric- or UV photolytic-accelerated aging to identify and better understand each material's degradation modes and the backsheets' field reliability. In addition to the artificial aging, the natural weathering methods used in this study are described. The comprehensive set of chemical, mechanical, and structural characterizations at intermittent read points in this study is presented, including: visual appearance and color; gloss; mechanical tensile testing; I-V performance; electroluminescence (EL) imaging; dielectric breakdown; FTIR-chemical structure; X-ray-polymer structure (WAXS); and DSC-crystalline content. After 4000 h of aging, a strong correlation occurs between initial physical characteristics (mechanical tensile test) and operating performance (EL and I-V characteristics). This presentation focuses on gloss, FTIR, and breakdown voltage measurements. Results for MiMo power, grayness from EL imaging, optical micrscopy, and specimen morphology (on extraction when cut from MiMos) is also presented.

backsheet↗