Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Grid Intensity Map-Based Source Model for Monte Carlo Modeling of IMRT Field Irradiation - Paper 5

An accurate source model is important for TPS (Treatment Planning System) dose calculation and verification, especially for IMRT (Intensity Modulated Radiotherapy) irregular and inhomogeneous fields. Monte Carlo simulation is the most accurate way to calculate dose distributions in the heterogeneous media like human bodies. A full radiotherapy modeling generally includes Linac modeling and phantom dose calculation. Full Linac modeling is very time-consuming and requires highly detailed knowledge of the accelerator composition and structure, however, which is very difficult to obtain for commercial interests. Often all relevant parameters are not known with sufficient accuracy, and thus a time-consuming tuning of e.g. the electron beam spot size and energy must be performed. A multiple source model (MSM) regards particles coming from different parts of an accelerator as if they are coming from different virtual sources. MSM uses a set of virtual sources representing the treatment beam (e.g. primary photons, head scatter, electron contamination) by a set of analytic functions or histograms with parameters derived from dosimetric measurements or a full MC simulation. Tillikainen et al built a three sub-source model by matching with measurement data using an automatic process to optimize the free model parameters for a Varian 2100 C/D accelerator. Lin et al have built a convenient five-photon-sub-source model for Varian 2300C 6 MV-X beam based on Monte Carlo simulated Linac for ARTS (Accurate Radiotherapy System). The particle generation of MSM is very fast compared to full Linac simulation, and its sampling efficiency is not limited by the size of the phase space file (PSF). However, generally MSM is generated based on regular field PSF and needs an irregular component to form the beam shape meanwhile apt to bringing error Linac modeling and MSM producing from PSF analysis actually both are multi-freedom optimization process by adjusting several parameters (e.g. electron energy and angular divergence). Linac modeling adjusts its parameters from the beginning of electron hitting target through all components to fit the simulation to the measurement. MSM tunes its PSF-derived parameters by optimizing to minimize the deviations between the simulation and the measurement. Since the full Linac modeling and the MSM model both need to fine tune their parameters to match the simulation to the measurement, and sometimes maybe offsets the real accelerator for its multi-parameter optimization process. So, why not fine tune directly all source model parameters just behind all Linac components to fit the simulation to the measurement? A grid intensity-based surface source model was suggested here, which assumed the particle emitting from the bottom surface of Linac last beam trimmer MLC (Multi Leaf Collimator). The particle emitting position is sampled on the grid intensity map optimized by TPS, and the particle weight is adjusted by its original grid intensity. This source model not only takes advantage of the Monte Carlo method in the heterogeneous media, but also avoids effectively the transportation speed shortcoming of Monte Carlo simulation through Linac components. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Coherent Scattering of a Multiphoton Quantum Superposition by a Mirror BEC

We present the proposition of an experiment in which the multiphoton quantum superposition consisting of Napprox =10{sup 5} particles generated by a quantum-injected optical parametric amplifier, seeded by a single-photon belonging to an Einstein-Podolsky-Rosen entangled pair, is made to interact with a mirror-Bose-Einstein condensate (BEC) shaped as a Bragg interference structure. The overall process will realize a macroscopic quantum superposition involving a microscopic single-photon state of polarization entangled with the coherent macroscopic transfer of momentum to the BEC structure, acting in spacelike separated distant places.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the HAE activity in the TJ-II stellarator using a Landau closure model

The aim of this study is to analyze the stability of helical Alfvén eigenmodes (HAEs) in TJ-II discharges and the stabilizing effect of the energetic particles generated by the neutral beam injector (NBI) on pressure gradient-driven modes (PGDMs). HAE and PGDM stability is studied using the linear version of the gyro-fluid code FAR3d and the continuous structure by the STELLGAP code. First, Alfvén eigenmode (AE) and PGDM activity observed in the experiments is reproduced by the simulations, identifying unstable m/n = 4/7 − 2/3 and 7/12 − 5/8 HAEs triggered around ρ = 0.66 showing a frequency of 209 and 204 kHz, respectively, as well as 5/3 PGDM. Next, a parametric study is performed with respect to the thermal ion density and iota profile in the middle-outer plasma region to verify the robustness of the simulation results with respect to the uncertainty of experimental profiles. The analysis confirms that experimental uncertainty does not cause large deviations in the simulation results, showing the destabilization of the same HAEs for all the configurations tested. The simulations also indicate the decay of the 5/3 PGDM growth rate as the energetic particle (EP) population in the plasma increases, consistent with the experiment. Stability analysis of the n = 3, 7, 11, n = 5, 9, 13, n = 6, 10, 14, and n = 8, 12 helical families is performed with respect to the NBI operational regime for different EP energies, β as well as deposition profiles. The most unstable configuration is the radially localized on-axis NBI operation (stiff EP density profile gradients nearby the magnetic axis). Using the simulation model that reproduces the observed Alfvén activity, we extend the study to analyze NBI performance within a theoretical framework. It shows that increasing NBI voltage (which raises EP energy) leads to a degradation in NBI performance for a given power (related to EP β and their density). To achieve better NBI operation, higher voltage must be balanced with lower injection power, ensuring stable AEs while keeping the same EP β.

Plasma confinement↗

Proposal for high pressure RF cavity test in the MTA

In order to demonstrate the feasibility of high pressure hydrogen gas filled RF (HPRF) cavities for muon ionization cooling, an HPRF cavity must be tested with a high intensity charged beam. When an HPRF cavity is irradiated with an intense beam each incident particle generates about 1000 electrons and ions per cubic centimeter in a high pressure cavity via ionization. These ionization electrons are influenced by the RF field and the RF quality factor goes down. This Q factor reduction will be a problem with a multi bunch beam, e.g., a muon beam for a muon collider consists of a 12 to 20 bunch train beam with 5 ns timing gap. Thus, the RF field must recover in few nano seconds. We propose to use a 400 MeV proton beam in the MTA and measure a beam loading effect in the HPRF cavity and study the recovery mechanism of the RF field.

43 PARTICLE ACCELERATORS↗

In situ monitoring of the stopped muon flux at Mu2e

The specific object of Mu2e search is the neutrino-less coherent $\mu^-\rightarrow e^-$ conversion in the field of an aluminum nucleus and the signal is a monoenergetic electron of energy $ \approx 104.97$ MeV. This process is forbidden in the Standard Model but allowed in many of its extensions: with minimal changes to include neutrino masses and oscillation, the Branching Ratio of this process, or the similarly interesting $\mu\rightarrow e \gamma$ decay, is expected to be of the order of $\mathcal{O}(10^{-54})$. Values like these are below any currently achievable experimental sensitivity, and the observation of a signal would be unambiguous evidence of New Physics. The upper limit on the muon conversion was set by SINDRUM II at $7\times10^{-13}$ (90\% C.L.) and the goal of the Mu2e collaboration is an improvement of 4 order of magnitudes.\\ The Mu2e experiment can be conceptually divided into three stages: interaction of the primary proton pulse with the tungsten target a nd production of $\pi$ and $\mu$; collection and transport of the produced particles down to the aluminum stopping target; interaction with the stopping target and measurement of the output particles. The measurement of the stopped muon flux is of cardinal importance for the normalization of the Mu2e results. The baseline design includes two detectors developed to measure this flux, counting $\gamma$ emitted by the muonic atoms: HPGe and LaBr$_3$(Ce). The studies performed by the Mu2e Collaboration show that these two systems can be reliably used to determine the overall normalization.\\ The number of stopped muons is proportional to the number of protons on target, which itself depends on the extraction system for the proton beam. The Mu2e beam delivery system will use a resonant extraction to create the proton pulses and this method is characterized by intensity fluctuations on the time scale of milliseconds. These fluctuations, aside from the proportional fluctuation of t he number of muons, have a non-trivial impact on the overall! performance of the apparatus. For example, higher intensity proton bunches translate into higher veto rates by the Cosmic Rays Veto system, which is triggered by secondary particles generated by the proton interaction. Another example is the effect of the instantaneous luminosity on the reconstruction efficiency: higher intensity translates into higher detector occupancy, which in turn reduces the reconstruction efficiency.\\ The two cited detectors encounter limitations when trying to monitor the flux at the millisecond timescales: HPGe is by construction a slow detector while the rate of emission of the $\gamma (1809\textrm{ keV})$ the LaBr$_3$(Ce) will measure is too low. As of today, no system allows to monitor these fluctuations and the goal of this Thesis is to try filling this gap. The method we developed to monitor the fluctuations of the stopped muon flux, and by extension, the fluctuation in the proton pulses intensity is based on counting the number of muons capt ured in the stopping target by counting the number of protons produced in the process of the nuclear muon capture. This is one of the possible processes a stopped muon can undergo and it can lead to the ejection of charged particles.\\ The reconstruction algorithms were developed by the Mu2e collaboration with the explicit (and sometimes implicit) aim to reconstruct tracks of electrons in an energy range of a conversion electron. The protons we are interested in behave quite differently from these electrons and the cardinal task of this study has been to tailor the reconstruction routines to these particles. This has been done by analyzing simulated events consisting of a single proton to optimize the procedure and understand the features of these tracks. A major difference with respect to the electrons is the non-relativistic nature of $100\div300$ MeV$/c$ protons: accounting for the low velocity is both a challenge and a unique signature of the tracks.\\ The use of a pulse d beam and the need to allow produced $\pi$ to decay and $\m! u$ to int! eract in the stopping target forces the definition of a Mu2e \textit{event}: an event is comprised by everything which happens in a $1.7\ \mu$s window between the incidence two consecutive proton pulses. This means that the reconstruction will be performed in an environment crowded by many different particles. The next step of this study has been to estimate the performance of the method in a fully-fledged Mu2e simulated event and to study what kind of selections would improve it.\\ Our results are satisfactory since the number of reconstructed protons is significant (few per event), and show that a monitor on the timescale of milliseconds is indeed possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anomalous radon emission as precursor of medium to strong earthquakes

Anomalous radon (Rn{sup 222}) emissions enhanced by forthcoming earthquakes is considered to be a precursory phenomenon related to an increased geotectonic activity in seismic areas. Rock microfracturing in the Earth’s crust preceding a seismic rupture may cause local surface deformation fields, rock dislocations, charged particle generation and motion, electrical conductivity changes, radon and other gases emission, fluid diffusion, electrokinetic, piezomagnetic and piezoelectric effects as well as climate fluctuations. Space-time anomalies of radon gas emitted in underground water, soil and near the ground air weeks to days in the epicentral areas can be associated with the strain stress changes that occurred before the occurrence of medium and strong earthquakes. This paper aims to investigate temporal variations of radon concentration levels in air near or in the ground by the use of solid state nuclear track detectors (SSNTD) CR-39 and LR-115 in relation with some important seismic events recorded in Vrancea region, Romania.

58 GEOSCIENCES↗

Self-Destructing Dark Matter

We present Self-Destructing Dark Matter (SDDM), a new class of dark matter models which are detectable in large neutrino detectors. In this class of models, a component of dark matter can transition from a long-lived state to a short-lived one by scattering off of a nucleus or an electron in the Earth. The short-lived state then decays to Standard Model particles, generating a dark matter signal with a visible energy of order the dark matter mass rather than just its recoil. This leads to striking signals in large detectors with high energy thresholds. We present a few examples of models which exhibit self destruction, all inspired by bound state dynamics in the Standard Model. The models under consideration exhibit a rich phenomenology, possibly featuring events with one, two, or even three lepton pairs, each with a fixed invariant mass and a fixed energy, as well as non-trivial directional distributions. This motivates dedicated searches for dark matter in large underground detectors such as Super-K, Borexino, SNO+, and DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

α-Particle Detection and Charge Transport Characteristics in the A 3 M 2 I 9 Defect Perovskites (A = Cs, Rb; M = Bi, Sb)

Here, we have investigated the defect perovskites A 3 M 2 I 9 (A = Cs, Rb; M = Bi, Sb) as materials for radiation detection. The phase purity of Bridgman-grown A 3 M 2 I 9 single crystals was confirmed via high-resolution synchrotron X-ray diffraction, while density functional theory calculations (DFT) show surprisingly dispersive bands in the out-of-plane direction for these layered materials, with low effective masses for both holes and electrons. Accordingly, each of the four A 3 M 2 I 9 defect perovskites showed response to 241 Am α-particle irradiation for hole and electron electrode configurations, a remarkable ambipolar response that resembles the 3D halide perovskites. The electron response spectra were used to estimate the mobility–lifetime product (μτ) e for electrons in these materials, with Rb 3 Bi 2 I 9 showing the lowest (μτ) e value of 1.7 × 10 – 6 cm 2 V –1 and Cs 3 Bi 2 I 9 the highest (μτ) e of 5.4 × 10 –5 cm 2 V –1 . The rise time of the α-particle-generated pulse was used to estimate the electron mobility μ e of the A 3 M 2 I 9 defect perovskites, which ranged from 0.32 cm 2 V –1 s–1 for Rb 3 Sb 2 I 9 to 4.3 cm 2 V –1 s –1 in Cs 3 Bi 2 I 9 . Similar analysis of the hole response spectra yielded (μτ) h values for each A 3 M 2 I 9 compound, with Cs 3 Bi 2 I 9 again showing the highest (μτ) h value of 1.8 × 10 –5 cm 2 V –1 , while Rb 3 Bi 2 I 9 showed the lowest (μτ) h with 2.0 × 10 –6 cm 2 V –1 . Rise time analysis gave hole mobilities ranging from 1.7 cm 2 V –1 s –1 for Cs 3 Bi 2 I 9 to 0.14 cm 2 V –1 s –1 for Cs 3 Sb 2 I 9 . Comparing the experimental electron and hole mobilities to the effective masses obtained from DFT calculations revealed sizable discrepancies, possibly indicating self-trapping of charge carriers due to electron–phonon interactions. The α-particle response of the A 3 M 2 I 9 defect perovskites demonstrates their potential as semiconductor radiation detectors, with Cs 3 Bi 2 I 9 and Cs 3 Sb 2 I 9 showing the most promise.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-initiated p – 11 B fusion reactions in petawatt high-repetition-rate laser facilities

Driving of the nuclear fusion reaction p + 11 B → 3α + 8.7 MeV under laboratory conditions by interaction between high-power laser pulses and matter has become a popular field of research, owing to its numerous potential applications: as an alternative to deuterium–tritium for fusion energy production, astrophysics studies, and alpha-particle generation for medical treatment. One possible scheme for laser-driven p– 11 B reactions is to direct a beam of laser-accelerated protons onto a boron (B) sample (the so-called “pitcher-catcher” scheme). This technique has been successfully implemented on large high-energy lasers, yielding hundreds of joules per shot at low repetition. We present here a complementary approach, exploiting the high repetition rate of the VEGA III petawatt laser at CLPU (Spain), aiming at accumulating results from many interactions at much lower energy, to provide better control of the parameters and the statistics of the measurements. Despite a moderate energy per pulse, our experiment allowed exploration of the laser-driven fusion process with tens (up to hundreds) of laser shots. The experiment provided a clear signature of the reactions involved and of the fusion products, accumulated over many shots, leading to an improved optimization of the diagnostics for experimental campaigns of this type. In this paper, we discuss the effectiveness of laser-driven p– 11 B fusion in the pitcher–catcher scheme, at a high repetition rate, addressing the challenges of this experimental scheme and highlighting its critical aspects. Our proposed methodology allows evaluation of the performance of this scheme for laser-driven alpha particle production and can be adapted to high-repetition-rate laser facilities with higher energy and intensity.

Alpha particles↗

MCNPX Simulation Study of STRAW Neutron Detectors

A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating (only 1 micron thick) of {sup 10}B as a neutron converter inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2 mils thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90%/10% of Ar/CO{sub 2}). The tubes operate in proportional counter mode and attract mobile charged particles ({alpha}'s) created in the nuclear interaction {sup 10}B(n, {sup 4}He){sup 7}Li. However, a single tube has about 1/7th the sensitivity of a {sup 3}He tube. Modeling is required to determine if enough such tubes could be placed in a neutron detection assembly of the current size to give comparable sensitivity to {sup 3}He. Detectors lined with {sup 10}B lie between {sup 3}He and {sup 10}BF{sub 3} proportional counters and fission chambers in terms of neutron detection efficiency and gamma ray insensitivity. The mean free path of thermal neutrons in {sup 10}B is about 18 {micro}m. It takes about 60 {micro}m of {sup 10}B layer to completely stop thermal neutrons, but the energetic {alpha}-particles generated in the reaction have a range of only 3.3 {micro}m in {sup 10}B environment - hence the thin layer of boron coating on the copper tube. The prototype design is shown in Figure 1. It consists of two panels of three staggered rows of 500-mm-long, 4-mm-diameter straws, with 20 in each row, embedded in 30-mm-thick high density polyethylene (HDPE). The project demonstrates a new application of thin neutron and gamma converter technique (1 micron thin {sup 10}B coated copper tube). It exploits fast timing from multiple straw detectors to count multiplicity of both gamma and neutrons from fissioning materials. The objective is to find a near-term replacement of {sup 3}He gas in neutron detection and measurement (with a very large neutron detection area). All the solid-state detectors developed thus far are small and inefficient. The thin size of the straws provides imaging capability with high enough resolution for radiation emitting sources. The prototype will provide the first aerial neutron detection system with directional sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the magnetic horn for the nuSTORM non-conventional neutrino beam using the genetic algorithm

This paper describes the strategy for optimizing the magnetic horn for the neutrinos from STORed Muons (nuSTORM) facility. The nuSTORM magnetic horn is the primary collection device for the secondary particles generated by bombarding a solid target with 120 GeV protons. As a consequence of the non-conventional beamline designed for nuSTORM, the requirements on the horn are different from those for a conventional neutrino beamline. At nuSTORM, muons decay while circulating in the storage ring, and the detectors are placed downstream of the production straight so as to be exposed to the neutrinos from muon decay. nuSTORM aims at precisely measuring the neutrino cross sections, and providing a definitive statement about the existence of sterile neutrinos. The nuSTORM horn aims at focusing the pions into a certain phase space so that more muons from pion decay can be accepted by the decay ring. The paper demonstrates a numerical method that was developed to optimize the horn design to gain higher neutrino flux from the circulating muons. A Genetic Algorithm (GA) was applied to the simultaneous optimization of the two objectives in this study. In conclusion, the application of the technique discussed in this paper is not limited to either the nuSTORM facility or muon based facilities, but can be used for other neutrino facilities that use magnetic horns as collection devices.

43 PARTICLE ACCELERATORS↗

Core-Cutoff Tool

A tool makes a cut perpendicular to the cylindrical axis of a core hole at a predetermined depth to free the core at that depth. The tool does not damage the surrounding material from which the core was cut, and it operates within the core-hole kerf. Coring usually begins with use of a hole saw or a hollow cylindrical abrasive cutting tool to make an annular hole that leaves the core (sometimes called the plug ) in place. In this approach to coring as practiced heretofore, the core is removed forcibly in a manner chosen to shear the core, preferably at or near the greatest depth of the core hole. Unfortunately, such forcible removal often damages both the core and the surrounding material (see Figure 1). In an alternative prior approach, especially applicable to toxic or fragile material, a core is formed and freed by means of milling operations that generate much material waste. In contrast, the present tool eliminates the damage associated with the hole-saw approach and reduces the extent of milling operations (and, hence, reduces the waste) associated with the milling approach. The present tool (see Figure 2) includes an inner sleeve and an outer sleeve and resembles the hollow cylindrical tool used to cut the core hole. The sleeves are thin enough that this tool fits within the kerf of the core hole. The inner sleeve is attached to a shaft that, in turn, can be attached to a drill motor or handle for turning the tool. This tool also includes a cutting wire attached to the distal ends of both sleeves. The cutting wire is long enough that with sufficient relative rotation of the inner and outer sleeves, the wire can cut all the way to the center of the core. The tool is inserted in the kerf until its distal end is seated at the full depth. The inner sleeve is then turned. During turning, frictional drag on the outer core pulls the cutting wire into contact with the core. The cutting force of the wire against the core increases with the tension in the wire and, hence, with the frictional drag acting on the outer sleeve. As the wire cuts toward the center of the core, the inner sleeve rotates farther with respect to the outer sleeve. Once the wire has cut to the center of the core, the tool and the core can be removed from the hole. The proper choice of cutting wire depends on the properties of the core material. For a sufficiently soft core material, a nonmetallic monofilament can be used. For a rubber-like core material, a metal wire can be used. For a harder core material, it is necessary to use an abrasive wire, and the efficiency of the tool can be increased greatly by vacuuming away the particles generated during cutting. For a core material that can readily be melted or otherwise cut by use of heat, it could be preferable to use an electrically heated cutting wire. In such a case, electric current can be supplied to the cutting wire, from an electrically isolated source, via rotating contact rings mounted on the sleeves.

Gheen, Darrell↗

Observation of Low-Frequency Electromagnetic Radiation from Laser-Plasmas

When an intense short laser pulse interacts with plasmas, the nonlinear interaction causes various phenomena such as high energy particle generation, strong radiation in the x-ray to THz frequency range. Formation of solitons is one of these interesting topics and has been studied mainly from theoretical aspects. Solitons are formed in an underdense plasma in the process of the laser pulse frequency downshift. They store a portion of the EM wave energy with the polarization inherited from the laser pulse-driver and emit it at the plasma-vacuum interface in the form of low frequency EM bursts. Solitons were observed experimentally by proton-beam imaging and in the visible-near-infrared emissions from the plasma. A low frequency EM radiation emission has also been observed in our experiments. The interpretation invokes the relativistic electromagnetic solitons. We present the results of the polarization-resolved measurements of low frequency radiation from the plasma region irradiated by the intense laser pulse. A dominant component of the observed THz radiation has the same polarization as the driver laser pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Universal tritium transmitter

At the Savannah River Site and throughout the National Nuclear Security Agency (NNSA) tritium is measured using Ion or Kanne Chambers. Tritium flowing through an Ion Chamber emits beta particles generating current flow proportional to tritium radioactivity. Currents in the 1 x 10{sup -15} A to 1 x 10{sup -6} A are measured. The distance between the Ion Chamber and the electrometer in NNSA facilities can be over 100 feet. Currents greater than a few micro-amperes can be measured with a simple modification. Typical operating voltages of 500 to 1000 Volts and piping designs require that the Ion Chamber be connected to earth ground. This grounding combined with long cable lengths and low currents requires a very specialized preamplifier circuit. In addition, the electrometer must be able to supply 'fail safe' alarm signals which are used to alert personnel of a tritium leak, trigger divert systems preventing tritium releases to the environment and monitor stack emissions as required by the United States federal Government and state governments. Ideally the electrometer would be 'self monitoring'. Self monitoring would reduce the need for constant checks by maintenance personnel. For example at some DOE facilities monthly calibration and alarm checks must be performed to ensure operation. NNSA presently uses commercially available electrometers designed specifically for this critical application. The problems with these commercial units include: ground loops, high background currents, inflexibility and susceptibility to Electromagnetic Interference (EMI) which includes RF and Magnetic fields. Existing commercial electrometers lack the flexibility to accommodate different Ion Chamber designs required by the gas pressure, type of gas and range. Ideally the electrometer could be programmed for any expected gas, range and high voltage output. Commercially available units do not have 'fail safe' self monitoring capability. Electronics used to measure extremely low current must have sufficient time to thermally equilibrate. Amplifiers, transistors, resistors all need time to stabilize before the electrometer circuit will measure accurately in the 10{sup -15} and 10{sup -14} ampere range. Existing electrometers give the user no indication when the unit has stabilized and is acceptable for low level measurements. Savannah River National Laboratory (SRNL) funded through the NNSA Plant Directed Research and Development (PDRD) program, has developed a truly Universal Tritium Transmitter (UTT) capable of solving many known problems with existing commercial electrometers. This UTT pushes the state-of-the-art in electrometer design and incorporates solutions to deficiencies found in commercial electrometers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of High Pulsed Magnetic Field on the Dislocations and Mechanical Properties of Al{sub 2}O{sub 3}/Al Composites

At T6 state, Al–Zn–Mg–Cu aluminum matrix composites reinforced with Al{sub 2}O{sub 3} particles generated in situ were subjected to high pulsed magnetic fields at different magnetic induction intensities (B = 2, 3 and 4 T). The results show that the dislocation densities in the treated samples increased with increasing B, and the magnetoplastic effect was determined to be the primary cause. The effect of the magnetic field is believed to alter the spin state of free electrons between dislocations and obstacles from the singlet state (associated with high bonding energy) to the triplet state (low bonding energy). The maximum ultimate tensile strength of 532 MPa was obtained at B = 4 T with 30 pulses, which was 20.7% higher than that of the initial sample, primarily because of dislocation strengthening. At B = 2 T, the elongation was at its maximum of 9.3%, representing an increase of 12% compared with the initial sample, while the associated ultimate tensile strength (447 MPa) was still higher than that of the untreated sample (440 MPa). The relationship between mechanical properties and microstructure was analyzed, and the improved properties observed in this work are explained by the transition of the electron spin state and the piling up of dislocations.

36 MATERIALS SCIENCE↗

Foreword to the Special Issue on Ejecta

We report that ejecta physics is a young field, having developed over the last 60 years or so. Essentially, ejecta forms as a spray of dense particles generated from the free surface of metals subjected to strong shocks, but the detailed mechanisms controlling the properties of this particulate ejecta are only now being fully elucidated. The field is dynamic and rapidly growing, with military and industrial applications, and applications to areas such as fusion research. This Special Issue on Ejecta reports the current state of the art in ejecta physics, describing experimental, theoretical and computational work by research groups around the world. While much remains to be done, the dramatic recent progress in the field, some of it first reported here, means that this volume provides a particularly timely review. In this foreword, we provide a brief historical overview of the development of ejecta physics, to define the context for the work in the rest of this Special Issue.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation damage study of POCO ZXF-5Q graphite for neutrino production targets using 4.5 MeV helium ions

To address the challenges of increased beam power and target survivability associated with next-generation particle production beam lines, high dose, high-energy proton beam conditions are simulated using irradiation from low-energy ion beams. A low-energy ion irradiation study of POCO ZXF-5Q graphite under conditions similar to those of the NuMI NT-02 neutrino production target at the Fermi National Accelerator Laboratory is reported. Helium ion irradiation was performed at 100 ∘ C to a maximum damage level of 0.9 displacements per atom (DPA). Irradiation induced hardening, swelling of the irradiated region, inter-plane lattice expansion, and intraplane lattice contraction with increasing ion fluence was observed using micromechanical (nanoindentation, atomic force microscopy) and electron microscopy (high-resolution imaging, selected area diffraction) characterization. Similar changes were also observed in post irradiation examination of the NT-02 target indicating that ion irradiation can be a valuable tool for estimating radiation damage in proton beam targets. Caution must be exercised though, because the hardening, lattice alteration, and swelling occur to different magnitudes for a given damage level. The observed hardening and embrittlement were greater for ion irradiated graphite. For He ion irradiated samples the lattice spacing changes were smaller at low damage levels (78% less expansion and 71% less contraction at 0.1 DPA) and larger at high damage levels (38% more expansion and 5% more contraction at 0.9 DPA) relative to that observed in the NT-02 target. The magnitude of swelling was 8.5× greater under ion irradiation which is influenced by the differing damage gradients and inclusion of implanted He ions in the region of interest.

43 PARTICLE ACCELERATORS↗

Initial validation of ALFRED: A Monte Carlo code built on Geant4 for TREAT energy deposition

Predicting the energy deposited in the specimen during an experiment in the Transient Reactor Test (TREAT) Facility is a complex problem due to the nature of the transients occurring in the reactor. In addition, the many particles contributing to energy deposition have different behavior in time and space. ALFRED, a new Geant4 based code, is developed to transport and simulate each particle generated in the core. This code is verified against OpenMC (Open Monte Carlo) on the Godiva benchmark and a simple TREAT model. Next, the energy deposition in TREAT is calculated: 181.05 ± 0.01 MeV for the “instantaneous” energy deposition (which accounts for the energy deposited within 1 s after neutron emission) in fuel and 189.90 ± 0.01 MeV for the total energy deposition in fuel. We discuss these results in this paper with previous calculations and experimental evaluations. This work demonstrates ALFRED’s potential as a high-fidelity tool for computing the spatial and temporal energy deposition in TREAT paving the way for a better understanding of the energy coupling factors in TREAT.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗