Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle identication methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-G-JeP1-10: Feasibility of CyberKnife Tracking Using the Previously-Implanted Permanent Brachytherapy Seed Cloud

Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from the MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received research support and speaker honoraria from Accuray.

60 APPLIED LIFE SCIENCES↗

Effects of pulse duration on magnetostimulation thresholds

Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number of cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse durations. Results: The magnetostimulation limits decreased with increasing pulse duration (T{sub pulse}). For T{sub pulse} < 18 ms, the thresholds were significantly higher than at the longest pulse durations (p < 0.01, paired Wilcoxon signed-rank test). The normalized magnetostimulation threshold (B{sub Norm}) vs duration curve at all three frequencies agreed almost identically, indicating that the observed effect is independent of the operating frequency. At the shortest pulse duration (T{sub pulse} ≈ 2 ms), the thresholds were approximately 24% higher than at the asymptotes. The thresholds decreased to within 4% of their asymptotic values for T{sub pulse} > 20 ms. These trends were well characterized (R{sup 2} = 0.78) by a stretched exponential function given by B{sub Norm}=1+αe{sup −(T{sub p}{sub u}{sub l}{sub s}{sub e}/β){sup γ}}, where the fitted parameters were α = 0.44, β = 4.32, and γ = 0.60. Conclusions: This work shows for the first time that the magnetostimulation thresholds decrease with increasing pulse duration, and that this effect is independent of the operating frequency. Normalized threshold vs duration trends are almost identical for a 20-fold range of frequencies: the thresholds are significantly higher at short pulse durations and settle to within 4% of their asymptotic values for durations longer than 20 ms. These results emphasize the importance of matching the human-subject experiments to the imaging conditions of a particular setup. Knowing the dependence of the safety limits to all contributing factors is critical for increasing the time-efficiency of imaging systems that utilize time-varying magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ENSEMBLE SIMULATIONS OF PROTON HEATING IN THE SOLAR WIND VIA TURBULENCE AND ION CYCLOTRON RESONANCE

Protons in the solar corona and heliosphere exhibit anisotropic velocity distributions, violation of magnetic moment conservation, and a general lack of thermal equilibrium with the other particle species. There is no agreement about the identity of the physical processes that energize non-Maxwellian protons in the solar wind, but a traditional favorite has been the dissipation of ion cyclotron resonant Alfvén waves. This paper presents kinetic models of how ion cyclotron waves heat protons on their journey from the corona to interplanetary space. It also derives a wide range of new solutions for the relevant dispersion relations, marginal stability boundaries, and nonresonant velocity-space diffusion rates. A phenomenological model containing both cyclotron damping and turbulent cascade is constructed to explain the suppression of proton heating at low alpha-proton differential flow speeds. These effects are implemented in a large-scale model of proton thermal evolution from the corona to 1 AU. A Monte Carlo ensemble of realistic wind speeds, densities, magnetic field strengths, and heating rates produces a filled region of parameter space (in a plane described by the parallel plasma beta and the proton temperature anisotropy ratio) similar to what is measured. The high-beta edges of this filled region are governed by plasma instabilities and strong heating rates. The low-beta edges correspond to weaker proton heating and a range of relative contributions from cyclotron resonance. On balance, the models are consistent with other studies that find only a small fraction of the turbulent power spectrum needs to consist of ion cyclotron waves.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-07: A Comparison of SSD and Field Size Dependence of Output for Megavoltage Electron Beams for Different Manufacturers

Purpose: The purpose of this study was to compare the electron beam in-air output factor (H) for Varian and Siemens accelerators. Methods: Measurements were performed among four accelerators: Varian CL2300ix, Varian TrueBeam, Siemens Oncor, and Siemens Primus. The nominal electron energy measured ranges from 6 to 21 MeV. Measurements were made in air using a diode detector for different square cone sizes (6 – 25cm) with circular field inserts with radius r between 1 cm and 8 cm and for different SSD (100 – 120 cm). H is defined asH(r,SSD){sup =} X(r,SSD)/X(open,SSD), where X is the charge measured by the diode detector without buildup cap in air. Results: For the same nominal energy, cone size, radius of circular cutout, and SSD, H agreed within a maximum deviation of 2.3% and standard deviation of 1% among Varian accelerators but can be as much as 8.7% different between the Varian and the Siemens accelerators. H is a function of electron energy and cutout radius only when the field radius for H measured at different SSD is renormalized as r = r0*5/(SSD-95), where r{sub 0} is the physical field radius at the end of the cone. The radius dependence of H for five cone sizes (6×6, 10×10, 15×15, 20×20 and 25×25cm{sup 2}) and three SSD(100, 110 and 120cm) for three energies was measured. Conclusion: The in air output factor (H) measured for the same manufacturer can be treated as identical to within 1.1% for Varian machines and to within 1.6% for Siemens machines, but the difference in H measured for the different manufacturers is large enough (>2%) to require machine specific data set.

43 PARTICLE ACCELERATORS↗

Nb3Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for Energy recovery linac (ERL) applications. Nb3Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities fabricated at JLab and were proposed to be coated with Nb3Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavities needs to be improved to coat these cavities. This devel-opment advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb3Sn coated twin axis cavities.

Tiskumara, J.↗

Time evolution, Lamb shift, and emission spectra of spontaneous emission of two identical atoms

A unitary transformation method is used to investigate the dynamic evolution of two multilevel atoms, in the basis of symmetric and antisymmetric states, with one atom being initially prepared in the first excited state and the other in the ground state. The unitary transformation guarantees that our calculations are based on the ground state of the atom-field system and the self-energy is subtracted at the beginning. The total Lamb shifts of the symmetric and antisymmetric states are divided into transformed shift and dynamic shift. The transformed shift is due to emitting and reabsorbing of virtual photons, by a single atom (nondynamic single atomic shift) and between the two atoms (quasi-static shift). The dynamic shift is due to the emitting and reabsorbing of real photons, by a single atom (dynamic single atomic shift) and between the two atoms (dynamic interatomic shift). The emitting and reabsorbing of virtual and real photons between the two atoms result in the interatomic shift, which does not exist for the one-atom case. The spectra at the long-time limit are calculated. If the distance between the two atoms is shorter than or comparable to the wavelength, the strong coupling between the two atoms splits the spectrum into two peaks, one from the symmetric state and the other from the antisymmetric state. The origin of the red or blue shifts for the symmetric and antisymmetric states mainly lies in the negative or positive interaction energy between the two atoms. In the investigation of the short time evolution, we find the modification of the effective density of states by the interaction between two atoms can modulate the quantum Zeno and quantum anti-Zeno effects in the decays of the symmetric and antisymmetric states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commissioning a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of the quadrupoles. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing such a system. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). A previous study investigated the error associated with each step by using a permanent quadrupole magnet on an optical mover system. The study reported an error of 11{micro}m for step 1 and a repeatability of 4{micro}m for step 2. However, the set up used a FARO arm to measure tooling balls and didn't allow to accurately check step 2 for errors; an uncertainty of 100{micro}m was reported. Therefore, even though the repeatability was good, there was no way to check that the error in step 2 was small. Following the recommendations of that study, we used a CMM (Coordinate Measuring Machine) instead of the FARO arm for measuring the tooling balls. In addition, a roller cam positioner system replaced the optical movers for moving the quadrupole. With the exception of the quadrupole itself, the system was identical to what will be used in fiducializing the undulator quadrupoles. In this study, we investigate the new vibrating wire set up, including the error associated with each step of fiducialization. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note is a continuation of previous work to study the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

SU-E-T-377: Evaluation of a Novel Transmission Detector as a Reference Chamber for Use in Beam Measurements

Purpose: To evaluate a new transmission chamber for use as a reference chamber in measurements of beam data Methods: We assessed the performance of a new transmission detector, the Stealth Chamber, manufactured by IBA (IBA Dosimetry). The chamber has an active volume of 249 cm{sup 3}, with an attenuation equivalent of <0.5mm Al. We mounted the chamber to a TrueBeam linac (Varian Medical Systems, Palo Alto, CA) such that the active area is perpendicular to the beam direction. We performed PDD and profile measurements on field sizes from 1×1 cm{sup 2} to 10×10 cm{sup 2}, as well as for a 4 mm cone. The field detector was either a CC-13 chamber (IBA Dosimetry) with an active volume of 0.13 cm{sup 3} or an Edge Detector (Sun Nuclear, Melbourne, FL) with an active volume of 0.019 cm{sup 3}. For comparison we repeated all measurements using a CC-13 or CC-01 (active volume 0.01 cm{sup 3} ) chamber as reference detectors (IBA Dosimetry).All scans were acquired using a Blue Phantom2 (IBA Dosimetry) and IBA OmniPro-Accept v7.4.24 software. Results: All measurements with the Stealth Chamber were identical to those with ion reference chambers. For both regular and filter free 6MV beams there was agreement in PDDs and profiles, including the penumbra region, for all field sizes. This was true for the 4mm cone measurement, as well. The deviation between the Stealth and ion chamber measurements was on average 0.3%. Conclusion: The Stealth Chamber gives identical beam data as a conventional ion chamber for all field sizes. The advantage of the Stealth chamber over ion chambers is its efficiency. Once mounted, there is no need to reposition the chamber with varying field sizes. This translates into a huge savings in measurement time, as well as a reduction in potential errors due to reference chamber mispositioning.

43 PARTICLE ACCELERATORS↗

SELECTIVE REMOVAL OF STRONTIUM AND CESIUM FROM SIMULATED WASTE SOLUTION WITH TITANATE ION EXCHANGERS IN A FILTER CARTRIDGE CONFIGURATION

This report describes experimental results for the selective removal of strontium and cesium from simulated waste solutions using monosodium titanate (MST) and crystalline silicotitanate (CST)-laden filter cartridges. Four types of ion exchange cartridge media (CST and MST designed by both 3M and POROX{reg_sign}) were evaluated. In these proof-of-principle tests effective uptake of both Sr-85 and Cs-137 was observed. However, the experiments were not performed long enough to determine the saturation levels or breakthrough curve for each filter cartridge. POREX{reg_sign} MST cartridges, which by design were based on co-sintering of the active titanates with polyethylene particles, seem to perform as well as the 3M-designed MST cartridges (impregnated filter membrane design) in the uptake of strontium. At low salt simulant conditions (0.29 M Na{sup +}), the instantaneous decontamination factor (D{sub F}) for Sr-85 with the 3M-design MST cartridge measured 26, representing the removal of 96% of the Sr-85. On the other hand, the Sr-85 instantaneous D{sub F} with the POREX{reg_sign} design MST cartridge measured 40 or 98% removal of the Sr-85. Strontium removal with the 3M-design MST and CST cartridges placed in series filter arrangement produced an instantaneous decontamination factor of 41 or 97.6% removal compared to an instantaneous decontamination factor of 368 or 99.7% removal of the strontium with the POREX{reg_sign} MST and CST cartridge design placed in series. At high salt simulant conditions (5.6 M Na{sup +}), strontium removal with 3M-designed MST cartridge only and with 3M-designed MST and CST cartridges operated in a series configuration were identical. The instantaneous decontamination factor and the strontium removal efficiency, under the above configuration, averaged 8.6 and 88%, respectively. There were no POREX{reg_sign} cartridge experiments using the higher ionic strength simulant solution. At low salt simulant conditions, the uptake of Cs-137 with POREX{reg_sign} CST cartridge out performed the 3M-designed CST cartridges. The POREX{reg_sign} CST cartridge, with a Cs-137 instantaneous decontamination factor of 55 and a Cs-137 removal efficiency of 98% does meet the Cs-137 decontamination goals in the low salt simulant liquor. The Cs-137 removal with 3M-designed CST cartridge produced a decontamination factor of 2 or 49% removal efficiency. The Cs-137 performance graph for the 3M-designed CST cartridge showed an early cessation in the uptake of cesium-137. This behavior was not observed with the POREX{reg_sign} CST cartridges. No Cs-137 uptake tests were performed with the POREX{reg_sign} CST cartridges at high salt simulant conditions. The 3M-designed CST cartridges, with an instantaneous Cs-137 decontamination factor of less than 3 and a Cs-137 removal efficiency of less than 50% failed to meet the Cs-137 decontamination goals in both the low and high salt simulant liquors. This poor performance in the uptake of Cs-137 by the 3M CST cartridges may be attributed to fabrication flaws for the 3M-designed CST cartridges. The reduced number of CST membrane wraps per cartridge during the cartridge design phase, from 3-whole wraps to about 1.5, may have contributed to Cs-137 laden simulant channeling/by-pass which led to the poor performance in terms of Cs-137 sorption characteristics for the 3M designed CST cartridges. The grinding of CST ion exchange materials, to reduce the particle size distribution and thus enhance their easy incorporation into the filter membranes and the co-sintering of MST with polyethylene particles, did not adversely affect the sorption kinetics of both CST and MST in the uptake of Cs-137 and Sr-85, respectively. In general, the POREX{reg_sign} based cartridges showed more resistance to simulant flow through the filter cartridges as evidenced by higher pressure differences across the cartridges. Based on these findings they conclude that incorporating MST and CST sorbents into filter membranes represent a promising method for the semi-continuous removal of radioisotopes of strontium and cesium from waste solutions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-G-JeP1-04: Characterization of a High-Definition Optical Patient Surface Tracking System Across Five Installations

Purpose: To assess the performance of Varian’s real-time, Optical Surface Monitoring System (OSMS) by measuring relative regular and irregular surface detection accuracy in 6 degrees of motion (6DoM), across multiple installations. Methods: Varian’s Intracranial SRS Package includes OSMS, which utilizes 3 HD camera/projector pods to map a patient surface, track intra-fraction motion, and gate the treatment beam if motion exceeds a threshold. To evaluate motion-detection accuracy of OSMS, we recorded shifts of a cube-shaped phantom on a single Varian TrueBeam linear accelerator as known displacements were performed incrementally across 6DoM. A subset of these measurements was repeated on identical OSMS installations. Phantom motion was driven using the TrueBeam treatment couch, and incremented across ±2cm in steps of 0.1mm, 1mm, and 1cm in the cardinal planes, and across ±40° in steps of 0.1°, 1°, and 5° in the rotational (couch kick) direction. Pitch and Roll were evaluated across ±2.5° in steps of 0.1° and 1°. We then repeated this procedure with a frameless SRS setup with a head phantom in a QFix Encompass mask. Results: Preliminary data show OSMS is capable of detecting regular-surfaced phantom displacement within 0.03±0.04mm in the cardinal planes, and within 0.01±0.03° rotation across all planes for multiple installations. In a frameless SRS setup, OSMS is accurate to within 0.10±0.07mm and 0.04±0.07° across 6DoM. Additionally, a reproducible “thermal drift” was observed during the first 15min of monitoring each day, and characterized by recording displacement of a stationary phantom each minute for 25min. Drift settled after 15min to an average delta of 0.26±0.03mm and 0.38±0.03mm from the initial capture in the Y and Z directions, respectively. Conclusion: For both regular surfaces and clinical SRS situations, OSMS exceeds quoted detection accuracy. To reduce error, a warm-up period should be employed to allow camera/projector pod thermal stabilization.

60 APPLIED LIFE SCIENCES↗

Results of stainless steel canister corrosion studies and environmental sample investigations

This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of used nuclear fuel. The work involves both characterization of the potential physical and chemical environment on the surface of the storage canisters and how it might evolve through time, and testing to evaluate performance of the canister materials under anticipated storage conditions. To evaluate the potential environment on the surface of the canisters, SNL is working with the Electric Power Research Institute (EPRI) to collect and analyze dust samples from the surface of in-service SNF storage canisters. In FY 13, SNL analyzed samples from the Calvert Cliffs Independent Spent Fuel Storage Installation (ISFSI); here, results are presented for samples collected from two additional near-marine ISFSI sites, Hope Creek NJ, and Diablo Canyon CA. The Hope Creek site is located on the shores of the Delaware River within the tidal zone; the water is brackish and wave action is normally minor. The Diablo Canyon site is located on a rocky Pacific Ocean shoreline with breaking waves. Two types of samples were collected: SaltSmart™ samples, which leach the soluble salts from a known surface area of the canister, and dry pad samples, which collected a surface salt and dust using a swipe method with a mildly abrasive ScotchBrite™ pad. The dry samples were used to characterize the mineralogy and texture of the soluble and insoluble components in the dust via microanalytical techniques, including mapping X-ray Fluorescence spectroscopy and Scanning Electron Microscopy. For both Hope Creek and Diablo Canyon canisters, dust loadings were much higher on the flat upper surfaces of the canisters than on the vertical sides. Maximum dust sizes collected at both sites were slightly larger than 20 μm, but Phragmites grass seeds ~1 mm in size, were observed on the tops of the Hope Creek canisters. At both sites, the surface dust could be divided into fractions generated by manufacturing processes and by natural processes. The fraction from manufacturing processes consisted of variably-oxidized angular and spherical particles of stainless steel and iron, generated by machining and welding/cutting processes, respectively. Dust from natural sources consisted largely of detrital quartz and aluminosilicates (feldspars and clays) at both sites. At Hope Creek, soluble salts were dominated by sulfates and nitrates, mostly of calcium. Chloride was a trace component and the only chloride mineral observed by SEM was NaCl. Chloride surface loads measured by the Saltsmart™ sensors were very low, less than 60 mg m –2 on the canister top, and less than 10 mg m –2 on the canister sides. At Diablo Canyon, sea-salt aggregates of NaCl and Mg-SO 4 , with minor K and Ca, were abundant in the dust, in some cases dominating the observed dust assemblage. Measured Saltsmart™ chloride surface loads were very low (<5 mg m –2 ); however, high canister surface temperatures damaged the Saltsmart™ sensors, and, in view of the SEM observations of abundant sea-salts on the package surfaces, the measured surface loads may not be valid. Moreover, the more heavily-loaded canister tops at Diablo Canyon were not sampled with the Saltsmart™ sensors. The observed low surface loads do not preclude chloride-induced stress corrosion cracking (CISCC) at either site, because (1) the measured data may not be valid for the Diablo Canyon canisters; (2) the surface coverage was not complete (for instance, the 45º offset between the outlet and inlet vents means that near-inlet areas, likely to have heavier dust and salt loads, were not sampled); and (3) CISCC has been experimentally been observed at salt loads as low as 5-8 mg/m 2 . Experimental efforts at SNL to assess corrosion of interim storage canister materials include three tasks in FY14. First, a full-diameter canister mockup, made using materials and techniques identical to those used to make interim storage canisters, was designed and ordered from Ranor Inc., a cask vendor for Areva/TN. The mockup will be delivered prior to the end of FY14, and will be used for evaluating weld residual stresses and degrees of sensitization for typical interim storage canister welds. Following weld characterization, the mockup will be sectioned and provided to participating organizations for corrosion testing purposes. A test plan is being developed for these efforts. In a second task, experimental work was carried out to evaluate crevice corrosion of 304SS in the presence of limited reactants, as would be present on a dustcovered storage canister. This work tests the theory that limited salt loads will limit corrosion penetration over time, and is a continuation of work carried out in FY13. Laser confocal microscopy was utilized to assess the volume and depth of corrosion pits formed during the crevice corrosion tests. Results indicate that for the duration of the current experiments (100 days), no stifling of corrosion occurred due to limitations in the amount of reactants present at three different salt loadings. Finally, work has been carried out this year perfecting an instrument for depositing sea-salts onto metal surfaces for atmospheric corrosion testing purposes. The system uses an X-Y plotter system with a commercial airbrush, and deposition is monitored with a quartz crystal microbalance. The system is capable of depositing very even salt loadings, even at very low total deposition rates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A search for sterile neutrinos at the MINOS experiment

MINOS is a long baseline neutrino oscillation experiment based at the Fermi National Accelerator Laboratory in Illinois, USA. The experiment was designed to study neutrino oscillation phenomena. The v μ beam produced by the NuMI beam facility at FNAL is used along with two functionally identical detectors. The Near Detector at FNAL and a Far Detector 735 km away in the Soudan Underground Laboratory in northern Minnesota. Comparison of the observed spectra of neutrinos at the two detectors provides the evidence for neutrino oscillations. This thesis presents work on the postulated phenomena of sterile neutrinos. Oscillations between active and sterile neutrinos will lead to a deficit in the expected rate of measured Neutral Current interactions at the Far Detector. A technique for selecting Neutral Current events utilizing an Artificial Neural Network is presented with resulting overall efficiency of 91.1% and purity of 66.0%. A method of predicting the expected Charged and Neutral Current energy spectra at the Far Detector given the data recorded at the Near Detector is presented. A model to search for oscillations between sterile and active neutrinos is developed. Sources of systematic uncertainty that can effect the results of the analysis are discussed. The analysis developed is applied to a Standard Model 3 flavour oscillation model as a cross check under the scenarios with and without v e appearance. The oscillation parameters measured by this model are Δm 32 2 = (2.39 -0.15 +0.23 ) x 10 -3 eV 2 and θ 23 = 0.727 -0.11 +0.22 for the no v e appearance result. An analysis of the resulting prediction reveals no evidence for active neutrino disappearance. The analysis is then performed using the 4 flavour neutrino oscillation model developed. Again this is done under the 2 scenarios of v e appearance and no v e appearance. The results of this analysis are Δm 31 2 = 2.44 -0.14 +0.23 x 10 -3 eV 2 , θ 23 = 0.755 -0.12 +0.19 and θ 34 = 0.00 +0.35 for no v e appearance and Δm 31 2 = (2.46 -0.14 +0.21 ) x 10 -3 eV 2 , θ 23 = 0.849 -0.19 +0.12 and θ 34 = 0.00 +0.60 for v e appearance. This is consistent with no oscillations between active and sterile neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Muon Neutrino Disappearance with the NOvA Experiment

The NOvA experiment consists of two functionally identical tracking calorimeter detectors which measure the neutrino energy and flavour composition of the NuMI beam at baselines of 1~km and 810~km. Measurements of neutrino oscillation parameters are extracted by comparing the neutrino energy spectrum in the far detector with predictions of the oscillated neutrino energy spectra that are made using information extracted from the near detector. Observation of muon neutrino disappearance allows NOvA to make measurements of the mass squared splitting $\Delta m^2_{32}$ and the mixing angle $\theta_{23}$. The measurement of $\theta_{23}$ will provide insight into the make-up of the third mass eigenstate and probe the muon-tau symmetry hypothesis that requires $\theta_{23} = \pi/4$. This thesis introduces three methods to improve the sensitivity of NOvA's muon neutrino disappearance analysis. First, neutrino events are separated according to an estimate of their energy resolution to distinguish well resolved events from events that are not so well resolved. Second, an optimised neutrino energy binning is implemented that uses finer binning in the region of maximum muon neutrino disappearance. Third, a hybrid selection is introduced that selects muon neutrino events with greater efficiency and purity. The combination of these improvements produces an increase in the sensitivity of the analysis equivalent to collecting 40-100\% more data across the range of possible values of $\Delta m^2_{32}$ and $\sin^2\theta_{23}$. This thesis presents new results using a 14~ktonne detector equivalent exposure of $6.05\times 10^{20}$~protons~on~target. A fit to the far detector data, assuming normal hierarchy, produces $\Delta m^2_{32}=2.45^{+0.087}_{-0.079}\times10^{-3}~\text{eV}^2$ and $\sin^2\theta_{23}$ in the range 0.429~-~0.593 with two statistically degenerate best fit points at 0.481 and 0.547. This measurement is consistent with maximal mixing where $\theta_{ 23} = \pi/4$. The data used for this thesis is 1/6 of the to! tal data that NOvA expects to collect.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preparation and testing of corrosion and spallation-resistant coatings

The goal of this project was to take a recently developed method of bonding oxide dispersion-strengthened (ODS) FeCrAl plating to nickel superalloys closer to commercial use in syngas-fired turbines. The project was designed to better understand and develop the bonding process and to determine if plating APMT®, a specific highly oxidation-resistant ODS FeCrAl alloy made by Kanthal, onto nickel-based superalloy turbine parts is a viable method for substantially improving the lifetimes and maximum use temperatures of the parts. The superalloys investigated for protection were CM247LC and Rene® 80, both alumina scale-forming alloys. The method for bonding the APMT plate to the superalloys is called evaporative metal bonding, which involves placing a thin foil of zinc between the plate and the superalloy, clamping them together, and heating in an atmosphere-controlled furnace. Upon heating, the zinc melts and dissolves the oxide skins of the alloys at the bond line, allowing the two alloys to diffuse into each other. The zinc then diffuses through the alloys and evaporates from their surfaces, creating a bond between the APMT and the superalloy that is stronger than the APMT itself. Testing showed that the diffusivity of zinc in both APMT and CM247LC is quite similar at 700°C but 15 times higher in the APMT at 1214°C. Coefficients of thermal expansion were determined for each of the alloys as a function of temperature. This information was entered into a finite-element model using ANSYS, which was used to design a clamping jig for pressing the APMT to the superalloys at the bonding temperature. Scanning electron microscopy analyses of representative joints showed that no zinc remained in the alloys after bonding Unfortunately, the analyses also showed some small pieces of broken aluminum oxide scale near the bond lines, indicating that its scale was not sufficiently removed during prebonding cleaning. Samples from each of the bonded blocks were sent to Siemens for its standard oxidation, spallation, and corrosion testing, which was scheduled for completion in the spring of 2016. However, because of commercial demands, the tests were not completed by the time of this report except some initial spallation tests at 1150°C. In those tests, several of the APMT plates separated from the CM247LC, likely because of the remaining aluminum oxide scale on the surface of the CM247LC. This implies that surface preparation may need to include machining to remove the oxide scale before bonding rather than just sandblasting. In previous tensile testing at 950°C, the breaks in the tensile samples always occurred in the APMT and not at the joints. Gasifier sampling was completed to determine what types of trace contaminants may occur in cleaned and combusted syngas and that could lead to corrosion or deposition in turbines firing coal syngas. The sampling was done from a pressurized fluidized-bed gasifier and a pressurized entrained-flow gasifier. The particles captured on a filter from syngas were typically 0.2 to 0.5 μm in diameter, whereas those captured from the combusted syngas were slightly larger and more spherical. X-ray photoelectron spectroscopy done at Oak Ridge National Laboratory showed that the particles do not contain any metals and have an atomic composition almost identical to that of the polycarbonate filter. This indicates that the particles are primarily soot-based and not formed from volatilization of metals in the gasifiers.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of the approximations applied in the continuum-distorted-wave-eikonal-initial-state theory for the evaluation of ionization cross sections: Post-prior discrepancy, axial symmetry, and ion-ion interaction

When the continuum distorted wave with eikonal initial state (CDW-EIS) [D. S. Crothers and J. F. McCann, J. Phys B 16, 3229 (1983)] theory is applied to the evaluation of ionization cross sections, many additional approximations are assumed. However, usually, the influence of these approximations is not clear. Aiming to estimate them, we compare the differential and total cross sections obtained with diverse approximations for ionization of He atoms by proton impact. We analyze the post-prior discrepancy, which depends on the perturbative Hamiltonian applied in the scattering amplitude. We study the dependence of the cross sections on the description of the initial and final states. For this purpose, we use the 1Z and 5Z variational and numerical Optimized Potential Model (OPM) [J. D. Talman, Comput. Phys. Commun. 54, 85 (1989)] bound states for the initial target state, and for the final target state we set Coulomb waves with proper effective charges or the continuum state of an OPM potential model. The cross sections resulting from OPM post and prior versions are identical and show excellent agreement with experimental data in each case. Nevertheless, the cross section derived by the prior CDW-EIS, 5Z initial wave, and corresponding continuum state gives comparable results, requiring shorter computational work. Then we study the determination of the impact parameter ionization probability from the transition amplitudes, also including an axial symmetry for the ionization process. The hypothesis of this axial symmetry saves an angular integration in the evaluation of the probabilities. We analyze the variation of these probabilities within the post and prior formalisms and mention initial and final states, according to the supposed symmetry. We found that the probabilities derived with the axial symmetry concentrate at a lower impact parameter than the usual ones and are quite sensitive to the approximations used for the CDW-EIS evaluation. Furthermore, these probabilities underestimate distant collisions. In the last section we introduce the projectile-residual ion potential, and we discuss the effect of the diverse approximations on the dependence of the cross section as a function of the projectile scattering angle. We compare the projectile angular distribution resulting from a full Coulomb interaction between the ions with the one obtained by a screened potential, but in the latter case the theoretical distributions underestimate the experimental data. The OPM and 5Z functions give a good description of the experimental data.

74 ATOMIC AND MOLECULAR PHYSICS↗

A BAYESIAN ASSESSMENT OF P-VALUES FOR SIGNIFICANCE ESTIMATION OF POWER SPECTRA AND AN ALTERNATIVE PROCEDURE, WITH APPLICATION TO SOLAR NEUTRINO DATA

The usual procedure for estimating the significance of a peak in a power spectrum is to calculate the probability of obtaining that value or a larger value by chance (known as the 'p-value'), on the assumption that the time series contains only noise-typically that the measurements are derived from random samplings of a Gaussian distribution. However, since the use of p-values in other contexts is known to be misleading, it seems prudent to examine the implications of using p-values for significance estimation of power spectra. We really need to know the probability that the time series is-or is not-compatible with the 'null hypothesis' that the measurements are derived from noise. This probability can be calculated by Bayesian analysis, but this requires one to specify and evaluate a second hypothesis that the time series does contain a contribution other than noise. We show that the requirement that the p-value should be identical to the probability that the null hypothesis is true leads to an unacceptable form for the likelihood function associated with this hypothesis. We claim that, for this reason, the p-value is not an acceptable method for significance estimation of a power spectrum. In order to obtain an acceptable significance estimate, it is necessary to explicitly consider a second hypothesis, and the key challenge is to identify an appropriate likelihood function for this hypothesis. We first propose four simple conditions that it seems reasonable to impose on this function. We then examine a general functional form for the function, and find the simplest form (which has one free parameter) that meets these conditions. We then define two different ways of combining information derived from two independent power estimates. One procedure is to calculate the post-probabilities of the null hypothesis, convert these to odds-values, and sum the log-odds. The second procedure is to combine the p-values using a procedure due to R.A. Fisher, and to calculate the corresponding post-probability and hence the corresponding log-odds. It seems sensible-even if not logically essential-to seek a likelihood function for which the two procedures lead to the same answer. We find that this consistency condition may be satisfied, to good approximation, by a special case of the previously proposed likelihood function. We find that the resulting significance estimates are considerably more conservative than those usually associated with the p-values. As two examples, we apply the new procedure to two recent analyses of solar neutrino data: (1) power spectrum analysis of Super-Kamiokande data and (2) the combined analysis of radiochemical neutrino data and irradiance data.

79 ASTRONOMY AND ASTROPHYSICS↗