Thermal diffusivity measurements of particulates using the differentiated line source

A method is described in which thermal diffusivity measurements can be made on particulate materials using the identical instrumentation as described in previous papers for measuring thermal conductivity. The measurements for the two properties can be made simultaneously, thus eliminating the changes in conditions when they are made separately. This system has particular application for studies of simulated lunar, planetary, or asteroidal surfaces in which laboratory measurements can be correlated with astronomical observations of thermal inertia. A representative set of data is shown which gives thermal diffusivity and thermal conductivity measurements on a particulate basalt in which the values for each temperature were taken simultaneously. A value for specific heat is calculated for measurements taken at each temperature.

West, E. A.↗

Scattering of light from particulate surfaces. I - A laboratory assessment of multiple-scattering effects

In planetary applications it is sometimes important to know the degree to which multiple scattering is influencing the photometric properties of a surface. An investigation is conducted concerning the point at which the single-scattering approximation used in the theory developed by Hapke (1963) and Irvine (1966) breaks down. It is shown that the Hapke-Irvine photometric function provides an adequate representation of the scattering properties of particulate surfaces whose geometric albedos (or normal reflectances) do not exceed 0.3. An experiment is conducted to estimate the normal reflectance below which the Hapke-Irvine equation considered provides an adequate representation of the scattering properties of a particulate surface. The investigation makes use of a set of samples which were prepared by mixing magnesium oxide and charcoal powders. The samples have a range in normal reflectance from 0.04 to 1.04.

Veverka, J.↗

Enhanced hydrophilicity of chlorided aluminum oxide particulates

An enhancement of hydrophilicity for chlorided aluminas was demonstrated by the results obtained from gaseous H2O sorptions at 70-, 80-, and 86-percent relative humidity on alpha and gamma aluminum oxide particulates and on alpha and gamma aluminum oxide particulates with a chemisorbed surface chloride phase (produced by reactions of gaseous HCl + H2O on alumina). Continuous sorption histories for H2O on chlorided aluminas having specific surface areas that range from 7 to 227 sq m/g before chloriding indicated that initial sorption rates were directly linked to the extent of chemisorbed chlorided coverage and implied the same relationship for sorption capacities. The initial sorption rate on chlorided aluminas was found to be slower for the first exposure to H2O than for subsequent exposures (which reached equilibrated H2O coverages much faster), suggesting that slow chemical reactions between H2O and chlorided alumina may have been operative during initial exposures. Chlorided alumina particles were found to remain very hydrophilic (relative to nonchlorided analogs) for several H2O sorption/desorption cycles.

Cofer, W. R., III↗

Economic comparison of fabric filters and electrostatic precipitators for particulate control on coal-fired utility boilers

The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.

Cukor, P. M.↗

Quantitative mapping of particulate iron in an ocean dump using remotely sensed data

A remote sensing experiment was conducted at the industrial acid waste ocean dump site located approximately 38 n mi SE of Cape Henlopen, Delaware, to see if there was a relationship between aircraft remotely sensed spectral signatures and the iron concentration measured in the plume. Results are presented which show that aircraft remotely sensed spectral data can be used to quantify and map an acid waste dump in terms of its particulate iron concentration. A single variable equation using the ratio of band 2 (440-490 nm) radiance to band 4 (540-580 nm) radiance was used to quantify the acid plume and the surrounding water. The acid waste varied in age from freshly dumped to 3 1/2 hours old. Particulate iron concentrations in the acid waste were estimated to range up to 1.1 mg/liter at the 0.46 meter depth. A classification technique was developed to remove sunglitter-affected pixels from the data set.

Ohlhorst, C. W.↗

Optical polarimetry of particulate surfaces

Reflection polarimetry is a remote-sensing tool sensitive to the refractive index and microtexture of solid surfaces. Mechanisms producing linear polarization within a rough, porous, or particulate surface are discussed, and laboratory techniques for precise measurements are described in some detail. Polarimetry of atmosphereless solar-system bodies provides valuable indications of albedo for objects too small and distant for direct diameter determinations, and reveals that even quite small asteroids and satellites have particulate surfaces

Zellner, B.↗

Remote sensing of environmental particulate pollutants - Optical methods for determinations of size distribution and complex refractive index

A unifying approach, based on a generalization of Pearson's differential equation of statistical theory, is proposed for both the representation of particulate size distribution and the interpretation of radiometric measurements in terms of this parameter. A single-parameter gamma-type distribution is introduced, and it is shown that inversion can only provide the dimensionless parameter, r/ab (where r = particle radius, a = effective radius, b = effective variance), at least when the distribution vanishes at both ends. The basic inversion problem in reconstructing the particle size distribution is analyzed, and the existing methods are reviewed (with emphasis on their capabilities) and classified. A two-step strategy is proposed for simultaneously determining the complex refractive index and reconstructing the size distribution of atmospheric particulates.

Fymat, A. L.↗

Determination of the ground albedo and the index of absorption of atmospheric particulates by remote sensing. I - Theory

A statistical technique is developed for inferring the optimum values of the ground albedo and the effective imaginary term of the complex refractive index of atmospheric particulates. The procedure compares measurements of the ratio of the hemispheric diffuse to directly transmitted solar flux density at the earth's surface with radiative transfer computations of the same as suggested by Herman et al. (1975). A detailed study is presented which shows the extent to which the ratio of diffuse to direct solar radiation is sensitive to many of the radiative transfer parameters. Results indicate that the optical depth and size distribution of atmospheric aerosol particles are the two parameters which uniquely specify the radiation field to the point where ground albedo and index of absorption can be inferred. Varying the real part of the complex refractive index of atmospheric particulates as well as their vertical distribution is found to have a negligible effect on the diffuse-direct ratio. The statistical procedure utilizes a semi-analytic gradient search method from least-squares theory and includes a detailed error analysis.

King, M. D.↗

Reduction of particulate carryover from a pressurized fluidized bed

A bench-scale pressurized fluidized bed combustor (PFBC) constructed with a conical shape to reduce the particulate carryover is examined. The combustor was fed coal and limestone with the coal to air ratio varying from 0.033 to 0.098 (all lean) and the coal to limestone ratio varying from 0.06 to 0.36. Two cone angles were used and it is shown that the average particulate carryover of 2.5 grains/SCF is appreciably less than cylindrical fluidized bed combustors. In addition the carryover was correlated by multiple regression analysis to yield the dependence on bed depth and hence the collection efficiency, which was 20%. Finally, a comparison with a model indicated that the exhaust port may be below the transport disengaging height for most of the tests showing that further improvements could be achieved by increasing the freeboard height of the exhaust port above the bed.

Patch, R. W.↗

Atmospheric particulate analysis using angular light scattering

Using the light scattering matrix elements measured by a polar nephelometer, a procedure for estimating the characteristics of atmospheric particulates was developed. A theoretical library data set of scattering matrices derived from Mie theory was tabulated for a range of values of the size parameter and refractive index typical of atmospheric particles. Integration over the size parameter yielded the scattering matrix elements for a variety of hypothesized particulate size distributions. A least squares curve fitting technique was used to find a best fit from the library data for the experimental measurements. This was used as a first guess for a nonlinear iterative inversion of the size distributions. A real index of 1.50 and an imaginary index of -0.005 are representative of the smoothed inversion results for the near ground level atmospheric aerosol in Tucson.

Hansen, M. Z.↗

Upwelled spectral radiance distribution in relation to particulate matter in sea water

Spectral analysis of water color and concurrent measurements of the relative concentration of various particulate and dissolved constituents within a broad range of water types are necessary to quantify ocean color observations and successfully relate them to various biological and physical processes that can be monitored by remote sensing. Some of the results of a Nimbus-G prelaunch cruise in connection with the Coastal Zone Color Scanner (CZCS) experiment, which was carried out in the Gulf of Mexico in October 1977, are presented and discussed. Based upon a small but diverse sample of near-surface measurements, it appears possible to estimate total suspended particulate matter (SPM) to useful accuracies by forming ratios of the spectral radiances measured at wavelengths falling near the centers of certain CZCS bands, viz., 440 nm:550 nm and 440 nm:520 nm. Furthermore, the analysis suggests a very high degree of covariation between SPM and phytoplankton pigments except for certain well-defined special cases.

Clark, D. K.↗

Atmospheric particulate analysis using angular light scattering

Using light scattering matrix elements measured by a polar nephelometer, a procedure for estimating the characteristics of atmospheric particulates was developed. A theoretical library data set of scattering matrices derived from Mie theory was tabulated for a range of values of the size parameter and refractive index typical of atmospheric particles. Integration over the size parameter yielded the scattering matrix elements for a variety of hypothesized particulate size distributions. A least squares curve fitting technique was used to find a best fit for the experimental measurements. This was used as a first guess for a nonlinear iterative inversion of the size distribution. A real index of 1.50 and an imaginary index of -0.005 are representative of the smoothed inversion results for the near ground level atmospheric aerosol in Tucson.

Hansen, M. Z.↗

Airborne particulate soiling of terrestrial photovoltaic modules and cover materials

Results are presented for the first phase of a photovoltaic-module soiling study that was carried out with NASA participation to investigate the problem of the electrical performance degradation of flat-plate photovoltaic modules exposed at outdoor sites that is due to the accumulation of airborne particulates on sensitive optical surfaces. The results were obtained in both field and laboratory soiling experiments, as well as in materials field experiments using candidate encapsulants and top covers. It is concluded that: (1) the electrical performance degradation shows a significant time and site dependence, ranging from 2% to 60% power loss; (2) the rate of particulate accumulation appears to be largely material independent when natural removal processes do not dominate; (3) the effectiveness of natural removal processes, especially rain, is strongly material dependent; (4) top-cover materials of glass and plexiglass retain fewer particles than silicone rubber; and (5) high module voltages relative to ground do not appear to affect the rate of dirt accumulation on modules.

Hoffman, A. R.↗

Coprostanol as a potential tracer of particulate sewage effluent to shelf waters adjacent to the Chesapeake Bay

Samples were collected in the Chesapeake Bay entrance and contiguous shelf waters and were subsequently analyzed for particulate coprostanol and cholesterol concentrations. Surface coprostanol concentrations were fairly uniform, with a slight increase with depth. This increase with depth may be due to sewage-associated particulates settling as they leave the Bay, or the resuspension of contaminated sediment. Preliminary findings indicate sewage-associated materials are being transported from the Chesapeake Bay to shelf waters, where they may have a detrimental affect on living marine resources.

Brown, R. C.↗

Diesel Particulate Destruction

Pulsed electrical discharge eliminates particulates in diesel exhaust. Particulates in diesel exhaust gas destroyed by passing them through agglomerator and series of high voltage-biased grids.

Yang, L. C.↗

Remote sensing of atmospheric particulates: Technological innovation and physical limitations in applications to short-range weather prediction

Techniques for remote sensing of particles, from cloud droplet to hailstone size, using optical and microwave frequencies are reviewed. The inherent variability of atmospheric particulates is examined to delineate conditions when the signal can give information to be effectively utilized in a forecasting context. The physical limitations resulting from the phase, size, orientation and concentration variability of the particulates are assessed.

Curran, R. J.↗

The effects of particulates from solid rocket motors fired in space

The orbits attained by kick motor solid propellant particulates are modeled, and an estimate is made of the number of particulates which will remain in orbit. The fuel, Al2O3, is burned while inserting spacecraft into a transfer orbit and again while circularizing the GEO station. It is shown that 23 percent of 1 micron particles deorbit immediately, while most particles enter a retrograde orbit. The resulting flux is an order of magnitude larger than the micrometeoroid flux. The pressures exerted by solar radiation ensure that only 5 percent of the original flux is still in orbit after the first year. The estimates provided are valid for a large number of transfer orbit operations, but will vary widely over the short term.

Mueller, A. C.↗

Particulate contaminant relocation during shuttle ascent

The dislodgement, venting, and redeposition of particles on a surface in the shuttle bay by the vibroacoustic, gravitational, and aerodynamic forces present during shuttle ascent have been investigated. The particles of different sizes which are displaced, vented, and redistributed have been calculated; and an estimate of the increased number of particles on certain surfaces and the decrease on others has been indicated. The average sizes, velocities, and length of time for certain particles to leave the bay following initial shuttle doors opening and thermal tests have been calculated based on indirect data obtained during several shuttle flights. Suggestions for future measurements and observations to characterize the particulate environment and the techniques to limit the in-orbit particulate contamination of surfaces and environment have been offered.

Scialdone, J. J.↗