Search NASA⌕ Search

SEARCH · Search NASA

Results for “Patient Support System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Endovascular Treatment of Iatrogenic and Traumatic Carotid Artery Dissection

This paper reports on the early and midterm results of endovascular treatment of acute carotid artery dissections, its specific problems, and its limitations. We encountered seven patients with symptomatic extracranial carotid artery dissection, three cases of which occurred after carotid endarterectomy, two after carotid angioplasty and stenting, and two after trauma. Balloon-expandable and self-expanding stents were placed using a transfemoral approach. Success in restoring the carotid lumen was achieved in all patients. No procedure-related complications occurred. All patients experienced significant clinical improvement while in the hospital and achieved complete long-term recovery. At follow-up (mean, 22.4 months), good luminal patency of the stented segments was observed. In conclusion, in this small series, primary stent-supported angioplasty seems to be a safe and effective strategy in the treatment of selected patients having acute traumatic extracranial carotid artery dissection, with excellent early and midterm results. Larger series and longer-term follow-up are required before definitive recommendations can be made.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Computer-Aided Differential Diagnosis System to Distinguish Between Usual Interstitial Pneumonia and Non-specific Interstitial Pneumonia Using Texture- and Shape-Based Hierarchical Classifiers on HRCT Images

A computer-aided differential diagnosis (CADD) system that distinguishes between usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP) using high-resolution computed tomography (HRCT) images was developed, and its results compared against the decision of a radiologist. Six local interstitial lung disease patterns in the images were determined, and 900 typical regions of interest were marked by an experienced radiologist. A support vector machine classifier was used to train and label the regions of interest of the lung parenchyma based on the texture and shape characteristics. Based on the regional classifications of the entire lung using HRCT, the distributions and extents of the six regional patterns were characterized through their CADD features. The disease division index of every area fraction combination and the asymmetric index between the left and right lungs were also evaluated. A second SVM classifier was employed to classify the UIP and NSIP, and features were selected through sequential-forward floating feature selection. For the evaluation, 54 HRCT images of UIP (n = 26) and NSIP (n = 28) patients clinically diagnosed by a pulmonologist were included and evaluated. The classification accuracy was measured based on a fivefold cross-validation with 20 repetitions using random shuffling. For comparison, thoracic radiologists assessed each case using HRCT images without clinical information or diagnosis. The accuracies of the radiologists’ decisions were 75 and 87%. The accuracies of the CADD system using different features ranged from 70 to 81%. Finally, the accuracy of the proposed CADD system after sequential-forward feature selection was 91%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-BRB-06: Commissioning and Evaluation of EPID-Based in Vivo Dosimetry Software Using a Tissue-Maximum Ratio Approach

Purpose: To commission and evaluate an in vivo EPID-based transit dosimetry software (EPIgray, DOSIsoft, Cachan, France) using simple fields and TG119-based IMRT treatment plans. Methods: EPIgray was commissioned on a Truebeam based on finite tissue-maximum ratio (fTMR) measurements with solid water blocks of thicknesses between 0 and 37 cm. Field sizes varied from 2×2 to 20×20 cm{sup 2}. Subsequently, treatment plans of single and opposed beams with field sizes between 4×4 and 15×15 cm{sup 2} as well as IMRT plans were measured to evaluate the dose reconstruction accuracy. Single field dose predictions were made for anterior-posterior and lateral beams. IMRT plans were created based on TG119 recommendations. The reconstructed dose was compared to the planned dose for selected points at isocenter and away from isocenter. Results: For single square fields, the dose in EPIgray was reconstructed within 3% accuracy at isocenter relative to the planned dose. Similarly, the relative deviation of the total dose was accurately reconstructed within 3% for all IMRT plans with points placed inside a high dose region near the isocenter. Predictions became less accurate than 5% when the evaluation point was outside the majority of IMRT beam segments. Additionally, points 5 cm or more away from the isocenter or within an avoidance structure were predicted less reliably. Conclusion: EPIgray formalism accuracy is adequate for an efficient error detection system. It provides immediate intra-fractional feedback on the delivery of treatment plans without affecting the treatment beam. Besides the EPID, no additional hardware is required, which makes it accessible to all clinics. The software evaluates point dose measurements to verify treatment plan delivery and patient positioning within 5% accuracy, depending on the placement of evaluation points. EPIgray is not intended to replace patient-specific quality assurance but should be utilized as an additional layer of safety for continuous patient treatment verification. This research is supported by DOSIsoft.

60 APPLIED LIFE SCIENCES↗

Objective Structured Clinical Evaluation (OSCE) of an Artificial Intelligence (AI) Clinical Decision Support System (CDSS) Tool

BACKGROUND Objective Structured Clinical Evaluations (OSCEs) have long been established as a robust methodology for summative assessment of clinical skills and decision-making during medical education. The recent integration of Artificial Intelligence (AI) into clinical decision-making processes has prompted the need for novel evaluation frameworks to assess the efficacy and reliability of AI clinical decision support system (CDSS) tools. This abstract outlines the process of quantitatively evaluating a novel CDSS (“Doc in a Box” Google 2024) trained on curated medical spaceflight data in the psychomotor domain as it interfaces with a human volunteer acting as the crew medical officer (CMO). PURPOSE The AI CDSS under review was developed as part of the Lunar Command and Control Interoperability (LuCCI) project, which is intended to address a gap in how Lunar Surface Systems (LSS) would interoperate across multiple programs, commercial partners, and international partners. The project objective is to define, prototype, integrate, and evaluate an interoperable lunar command, control, data, and software reference architecture to enable autonomy and informatics capability through common standards across LSS. A multi-modal AI-based CDSS compatible with Federated LSS will assist clinicians in diagnosing and managing complex medical conditions by providing evidence-based recommendations through predictive analytics. Given the critical role of decision-support as NASA continues to evolve its Earth-independent medical operations (EIMO), it is imperative to ensure that such AI tools perform reliably and align with clinical standards during progressive lunar and Martian exploration class missions. METHODS The OSCE framework, traditionally used for evaluating human clinicians, was adapted to assess the AI tool's decision-making capabilities in simulated clinical scenarios. In this adapted OSCE, the AI CDSS was tested across a series of structured clinical scenarios designed to mimic real-life spaceflight patient cases. These scenarios included a range of conditions and complexities, allowing for comprehensive assessment of the tool's performance. Key evaluation metrics included accuracy of diagnosis, timeliness of decision-making, and appropriate recommendations for therapies. The OSCE was scored by human physician evaluators who assessed the AI's recommendations in comparison with expert clinicians' medical decision making to ensure alignment with best practices and the standard of care. RESULTS Preliminary results indicate that the AI CDSS demonstrated high accuracy in diagnostic recommendations and decision support across various scenarios. However, certain limitations were noted, such as occasional discrepancies in handling complex or nuanced cases that required a more contextual understanding. Additionally, the tool scored higher on the diagnostic portion of the rubric, with lower scores in the therapeutic recommendations. These findings highlight the importance of continuous refinement and validation of AI tools through rigorous evaluation frameworks like the OSCE. The adaptation of OSCEs for AI tools presents several advantages, including a structured and reproducible approach to evaluation, the ability to test AI systems in diverse clinical scenarios, and the opportunity to benchmark AI performance against established clinical standards to permit charting of future progress as aerospace medicine evolves as a discipline. Remaining challenges include ensuring that these evaluations capture the full spectrum of clinical decision-making scenarios that will be confronted by CMOs during missions and adequately reflecting real-world variability of the austere spaceflight environment. CONCLUSION Employing OSCEs to evaluate AI clinical decision support tools offers a promising approach to validating their clinical utility and efficacy. This methodology not only provides insights into the tool's performance but also fosters ongoing improvement and alignment with standard of care practices. Future research should focus on refining these evaluation processes and addressing limitations to enhance the integration of AI tools in clinical spaceflight settings. REFERENCES Scott S, Hearns V, Barker MA. Testing Clinical Skills: A Look at the OSCE and USMLE Clinical Skills Exams. S D Med. 2019 Oct;72(10):451-453. Majumder MAA, Kumar A, Krishnamurthy K, Ojeh N, Adams OP, Sa B. An evaluative study of objective structured clinical examination (OSCE): students and examiners perspectives. Adv Med Educ Pract. 2019 Jun 5;10:387-397. Karam VY, Park YS, Tekian A, Youssef N. Evaluating the validity evidence of an OSCE: results from a new medical school. BMC Med Educ. 2018 Dec 20;18(1):313.

Ariana M Nelson↗

Immune inhibitory receptor LILRB2 is critical for the endometrial cancer progression

Although leukocyte immunoglobulin-like receptor subfamily B member 2 (LILRB2) is known as an immune inhibitory receptor to suppress the immune system, its function in cancer development remains largely unknown. Herein, we provide the first body of information showing that LILRB2 is highly expressed in the endometrial cancer. More importantly, the expression levels of LILRB2 are inversely correlated with the overall patients’ survival. Knockdown of LILRB2 results in a dramatic decrease in the proliferation, colony formation and migration in several endometrial cancer cell lines in vitro. Furthermore, in vivo xenograft experiments reveal a notable reduction of tumor cell growth. Mechanistically, LILRB2 enhances the SHP2/CaMK1/CREB signaling pathways to support the expansion and migration of the endometrial cancer cells. These findings unravel an unexpected role of LILRB2 in solid cancers except for its canonical role in immune surveillance, which may serve as a potential endometrial stem cell marker and may benefit the development of novel strategies for the treatment of endometrial cancers.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-00: Online Adaptive Radiotherapy - Considerations for Practical Clinical Implementation

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-01: Online Adaptive MR-Guided RT: Workflow and Clinical Implementation

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-02: MRI-Guided Online Adaptive Radiotherapy: The UCLA Approach to Quality Management

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

MO-E-BRC-03: Fast Online Replanning Techniques

Online adaptive radiation therapy has the potential to ensure delivery of optimal treatment to the patient by accounting for anatomical and potentially functional changes that occur from one fraction to the next and over the course of treatment. While on-line adaptive RT (ART) has been a topic of many publications, discussions, and research, it has until very recently remained largely a concept and not a practical implementation. However, recent advances in on-table imaging, use of deformable image registration for contour generation and dose tracking, faster and more efficient plan optimization, as well as fast quality assurance method has enabled the implementation of ART in the clinic in the past couple of years. The introduction of these tools into routine clinical use requires many considerations and progressive knowledge to understand how processes that have historically taken hours/days to complete can now be done in less than 30 minutes. This session will discuss considerations to perform real time contouring, planning and patient specific QA, as well as a practical workflow and the required resources. Learning Objectives: To understand the difficulties, challenges and available technologies for online adaptive RT. To understand how to implement online adaptive therapy in a clinical environment and to understand the workflow and resources required. To understand the limitations and sources of uncertainty in the online adaptive process I have research funding from ViewRay Inc. and Philips Medical Systems.; R. Kashani, I have research funding from ViewRay Inc. and Philips Medical Systems.; X. Li, Research supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Design of a digital beam attenuation system for computed tomography: Part I. System design and simulation framework

Purpose: The purpose of this work is to introduce a new device that allows for patient-specific imaging-dose modulation in conventional and cone-beam CT. The device is called a digital beam attenuator (DBA). The DBA modulates an x-ray beam by varying the attenuation of a set of attenuating wedge filters across the fan angle. The ability to modulate the imaging dose across the fan beam represents another stride in the direction of personalized medicine. With the DBA, imaging dose can be tailored for a given patient anatomy, or even tailored to provide signal-to-noise ratio enhancement within a region of interest. This modulation enables decreases in: dose, scatter, detector dynamic range requirements, and noise nonuniformities. In addition to introducing the DBA, the simulation framework used to study the DBA under different configurations is presented. Finally, a detailed study on the choice of the material used to build the DBA is presented. Methods: To change the attenuator thickness, the authors propose to use an overlapping wedge design. In this design, for each wedge pair, one wedge is held stationary and another wedge is moved over the stationary wedge. The composite thickness of the two wedges changes as a function of the amount of overlap between the wedges. To validate the DBA concept and study design changes, a simulation environment was constructed. The environment allows for changes to system geometry, different source spectra, DBA wedge design modifications, and supports both voxelized and analytic phantom models. A study of all the elements from atomic number 1 to 92 were evaluated for use as DBA filter material. The amount of dynamic range and tube loading for each element were calculated for various DBA designs. Tube loading was calculated by comparing the attenuation of the DBA at its minimum attenuation position to a filtered non-DBA acquisition. Results: The design and parametrization of DBA implemented FFMCT has been introduced. A simulation framework was presented with which DBA-FFMCT, bowtie filter CT acquisitions, and unmodulated CT acquisitions can be simulated. The study on wedge filter design concluded that the ideal filter material should have an atomic number in the range of 21-34. Iron was chosen for an experimental relative-tube-loading measurement and showed that DBA-FFMCT scans could be acquired with negligible increases in tube power demands. Conclusions: The basic idea of DBA implemented fluence field modulated CT, a simulation framework to verify the concept, and a filter selection study have been presented. The use of a DBA represents another step toward the ultimate in patient specific CT dose delivery as patient dose can be delivered uniquely as a function of view and fan angle using this device.

60 APPLIED LIFE SCIENCES↗

Structure and antigenicity of the divergent human astrovirus VA1 capsid spike

Human astrovirus (HAstV) is a known cause of viral gastroenteritis in children worldwide, but HAstV can cause also severe and systemic infections in immunocompromised patients. There are three clades of HAstV: classical, MLB, and VA/HMO. While all three clades are found in gastrointestinal samples, HAstV-VA/HMO is the main clade associated with meningitis and encephalitis in immunocompromised patients. To understand how the HAstV-VA/HMO can infect the central nervous system, we investigated its sequence-divergent capsid spike, which functions in cell attachment and may influence viral tropism. Here we report the high-resolution crystal structures of the HAstV-VA1 capsid spike from strains isolated from patients with gastrointestinal and neuronal disease. The HAstV-VA1 spike forms a dimer and shares a core beta-barrel structure with other astrovirus capsid spikes but is otherwise strikingly different, suggesting that HAstV-VA1 may utilize a different cell receptor, and an infection competition assay supports this hypothesis. Furthermore, by mapping the capsid protease cleavage site onto the structure, the maturation and assembly of the HAstV-VA1 capsid is revealed. Finally, comparison of gastrointestinal and neuronal HAstV-VA1 sequences, structures, and antigenicity suggests that neuronal HAstV-VA1 strains may have acquired immune escape mutations. Overall, our studies on the HAstV-VA1 capsid spike lay a foundation to further investigate the biology of HAstV-VA/HMO and to develop vaccines and therapeutics targeting it.

60 APPLIED LIFE SCIENCES↗

Architecture for Adaptive Intelligent Systems

We identify a class of niches to be occupied by 'adaptive intelligent systems (AISs)'. In contrast with niches occupied by typical AI agents, AIS niches present situations that vary dynamically along several key dimensions: different combinations of required tasks, different configurations of available resources, contextual conditions ranging from benign to stressful, and different performance criteria. We present a small class hierarchy of AIS niches that exhibit these dimensions of variability and describe a particular AIS niche, ICU (intensive care unit) patient monitoring, which we use for illustration throughout the paper. We have designed and implemented an agent architecture that supports all of different kinds of adaptation by exploiting a single underlying theoretical concept: An agent dynamically constructs explicit control plans to guide its choices among situation-triggered behaviors. We illustrate the architecture and its support for adaptation with examples from Guardian, an experimental agent for ICU monitoring.

ACTIVE CONTROL↗

Squamous Cell Carcinoma of the Anal Canal: Patterns and Predictors of Failure and Implications for Intensity-Modulated Radiation Treatment Planning

Purpose: Intensity-modulated radiation treatment (IMRT) is increasingly used in the treatment of squamous cell carcinoma of the anal canal (SCCAC). Prevention of locoregional failure (LRF) using IMRT requires appropriate clinical target volume (CTV) definition. To better define the CTV for IMRT, we evaluated patterns and predictors of LRF in SCCAC patients given conventional radiation treatment. Methods and Materials: We reviewed records of 180 SCCAC patients treated with conventional radiation with or without chemotherapy at our institution between January 1990 and March 2007. All patients received radiation; the median primary tumor dose was 45 Gy. A total of 173 patients also received mitomycin-based chemotherapy. Results: Median follow-up was 40 months. Actuarial 3-year colostomy-free survival was 89% and overall survival (OS) 88%. Actuarial 3-year LRF was 23%. A total of 45 patients had LRF, with 35 (78%) occurring locally in the primary site (25 local only, 10 local and regional); however, 20 (44%) had regional components of failure within the pelvis or inguinal nodes (10 regional only, 10 local and regional). Cumulative sites of LRF (patients may have one or more site of failure) were as follows: primary, 35; inguinal, 8; external perianal, 5; common iliac, 4; presacral, 3; distal rectum, 2; external iliac, 2; and internal iliac, 2. All patients with common iliac failure had cT3 or N+ disease. Conclusions: The observed patterns of failure support inclusion of the inguinal and all pelvic nodal groups in the CTV for IMRT. In patients with advanced tumor or nodal stage, common iliac nodes should also be included in the CTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-BRD-05: Results From Multi-Institutional Measurements with An Anthropomorphic Spine Phantom

Purpose: To analyze the results from an anthropomorphic spine phantom used for credentialing institutions for National Cancer Institute (NCI) sponsored clinical trial. Methods: An anthropomorphic phantom that contains left and right lungs, a heart, an esophagus, spinal cord, bony material and a PTV was sent to institutions wishing to be credentialed for NCI trials. The PTV holds 4 TLD and radiochromic film in the axial and sagittal planes. The heart holds one TLD. Institutions created IMRT plans to cover ≥90% of the PTV with 6 Gy and limit the cord dose to <0.35cc receiving 3.75 Gy and <1.2cc receiving 2.63 Gy. They were instructed to treat the phantom as they would a patient, including making plan specific IMRT/SBRT QA measurements before treatment. The TLD results in the PTV were required to be within ±7% of the plan dose. A gamma calculation was performed using the film results and the submitted DICOM plan. ≥85% of the analyzed region was required to pass a 5%/3 mm criteria. Results: 176 institutions irradiated the spine phantom for a total of 255 results. The pass rate was 73% (187 irradiations) overall. 44 irradiations failed only the gamma criteria, 2 failed only the dose criteria and 22 failed both. The most used planning systems were Eclipse (116) and Pinnacle (52) and they had pass rates of 76% and 71%, respectively. The AAA algorithm had a pass rate of 77% while superposition type algorithms had a 71% pass rate. The average TLD measurement to institution calculation ratio was 0.99 (0.04 std dev.). The average percent pixels passing the gamma criteria for films was 89% (12% std dev.) Conclusion: Results show that this phantom is an important part of credentialing and that we have room for improvement in IMRT/SBRT spine treatments. This work was supported by PHS CA180803 and CA037422 awarded by NCI, DHHS.

60 APPLIED LIFE SCIENCES↗

SU-E-T-508: End to End Testing of a Prototype Eclipse Module for Planning Modulated Arc Therapy On the Siemens Platform

Purpose: The latest clinical implementation of the Siemens Artiste linac allows for delivery of modulated arcs (mARC) using full-field flattening filter free (FFF) photon beams. The maximum doserate of 2000 MU/min is well suited for high dose treatments such as SBRT. We tested and report on the performance of a prototype Eclipse TPS module supporting mARC capability on the Artiste platform. Method: our spine SBRT patients originally treated with 12/13 field static-gantry IMRT (SGIMRT) were chosen for this study. These plans were designed to satisfy RTOG0631 guidelines with a prescription of 16Gy in a single fraction. The cases were re-planned as mARC plans in the prototype Eclipse module using the 7MV FFF beam and required to satisfy RTOG0631 requirements. All plans were transferred from Eclipse, delivered on a Siemens Artiste linac and dose-validated using the Delta4 system. Results: All treatment plans were straightforwardly developed, in timely fashion, without challenge or inefficiency using the prototype module. Due to the limited number of segments in a single arc, mARC plans required 2-3 full arcs to yield plan quality comparable to SGIMRT plans containing over 250 total segments. The average (3%/3mm) gamma pass-rate for all arcs was 98.5±1.1%, thus demonstrating both excellent dose prediction by the AAA dose algorithm and excellent delivery fidelity. Mean delivery times for the mARC plans(10.5±1.7min) were 50-70% lower than the SGIMRT plans(26±2min), with both delivered at 2000 MU/min. Conclusion: A prototype Eclipse module capable of planning for Burst Mode modulated arc delivery on the Artiste platform has been tested and found to perform efficiently and accurately for treatment plan development and delivered-dose prediction. Further investigation of more treatment sites is being carried out and data will be presented.

60 APPLIED LIFE SCIENCES↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxaliplatin Plus Dual Inhibition of Thymidilate Synthase During Preoperative Pelvic Radiotherapy for Locally Advanced Rectal Carcinoma: Long-Term Outcome

Purpose: To assess the safety and efficacy of oxaliplatin (OXA) plus dual inhibition of thymidilate synthase during preoperative pelvic radiotherapy (RT) in patients with poor prognosis for rectal carcinoma. Methods and Materials: Sixty-three patients with the following characteristics, a clinical (c) stage T4, cN1-2, or cT3N0 of {<=}5 cm from the anal verge and/or with a circumferential resection margin (CRM) of {<=}5 mm (by magnetic resonance imaging), received three biweekly courses of chemotherapy with OXA, 100 mg/m{sup 2}; raltitrexed (RTX), 2.5 mg/m{sup 2} on day 1, and 5-fluorouracil (5-FU), 900 mg/m{sup 2} (31 patients) or 800 mg/m{sup 2} (32 patients); levo-folinic acid (LFA), 250 mg/m{sup 2} on day 2, during pelvic RT (45 Gy). Pathologic response was defined as complete pathological response (ypCR), major (tumor regression grade(TRG) 2 to 3, with ypCRM-ve and ypN-ve) or minor or no response (TRG4 to -5, or ypCRM+ve, or ypN+ve). Adjuvant 5-FU/LFA regimen was given in cases of cT4, ypN+ve, or ypCRM+ve. Results: Overall, neutropenia (40%) and diarrhea (13%) were the most common grade {>=}3 toxicities, and tolerability was better with a 5-FU dose reduction. No significant difference in pathologic response was seen according 5-FU dosage: overall, a ypCR was obtained in 24 (39%) patients, and a major response in 20 (32%) patients. The 5-year probability of freedom from recurrence was 80% (95% confidence interval, 68%-92%); it was 56% for the minor/no response group, while it was around 90% for both the ypCR and the major response group. Conclusions: OXA, RTX, and 5-FU/LFA administered during pelvic RT produced promising early and long-term results in rectal carcinoma patients with poor prognosis. The postoperative treatment strategy applied in our study supports the risk-adapted approach in postoperative management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-537: Prone Breast Accelerated Partial Breast Irradiation Using Non-Coplanar Volumetric Arc Therapy

Purpose: To demonstrate that Volumetric Modulated Arc Therapy (VMAT) can be an alternative technique to Brachytherapy Accelerated Partial Breast Irradiation (APBI) for treating large breasted women. The non-coplanar VMAT technique uses a commercially available couch and a small number of angles. This technique with the patient in the prone position can reduce high skin and critical structure doses in large breasted women, which are usually associated with Brachytherapy APBI. Methods: Philips Pinnacle treatment planning system with Smart Arc was used to plan a left sided laterally located excision cavity on a standard prone breast patient setup. Three thirty-degree arcs entered from the lateral side at respective couch angles of 345, 0, and 15 degrees. A fourth thirty degree arc beam entered from the medial side at a couch angle of 0 degrees. The arcs were selected to avoid critical structures as much as possible. A test run was then performed to verify that the beams did not collide with the patient nor support structures. NSABP B-39/RTOG 0413 protocol guidelines were used for dose prescription, normal tissue, and target definition. Results: Dose Volume Histogram analysis indicated that all parameters were equal or better than RTOG recommendations. Of particular note regarding the plan quality:1.(a) For a prescribed dose of 3850cGy the PTV-EVAL target volume receiving 100 percent of the dose(V100) was 93; protocol recommendation is V90 > 90 percent. (b) Maximum dose was 110 percent versus the allowed 120 percent .2. Uninvolved percentage of normal breast V100 and V50 were 17 and 47 versus allowed 35 and 60 percent respectively.3. For the skin, V100 was 5.7cc and the max dose to 0.1 cc was 4190cGy. Conclusion: Prone Breast non-coplanar VMAT APBI can achieve better skin cosmesis and lower critical structure doses than Brachytherapy APBI.

60 APPLIED LIFE SCIENCES↗