Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Spectrotemporal CT data acquisition and reconstruction at low dose

Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

60 APPLIED LIFE SCIENCES↗

Molecular structure determination from x-ray scattering patterns of laser-aligned symmetric-top molecules.

We investigate the molecular structure information contained in the x-ray diffraction patterns of an ensemble of rigid CF{sub 3}Br molecules aligned by an intense laser pulse at finite rotational temperature. The diffraction patterns are calculated at an x-ray photon energy of 20 keV to probe molecular structure at angstrom-scale resolution. We find that a structural reconstruction algorithm based on iterative phase retrieval fails to extract a reliable structure. However, the high atomic number of Br compared with C or F allows each diffraction pattern to be treated as a hologram. Using this approach, the azimuthal projection of the molecular electron density about the alignment axis may be retrieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PLATFORM DEFORMATION PHASE CORRECTION FOR THE AMiBA-13 COPLANAR INTERFEROMETER

We present a new way to solve the platform deformation problem of coplanar interferometers. The platform of a coplanar interferometer can be deformed due to driving forces and gravity. A deformed platform will induce extra components into the geometric delay of each baseline and change the phases of observed visibilities. The reconstructed images will also be diluted due to the errors of the phases. The platform deformations of The Yuan-Tseh Lee Array for Microwave Background Anisotropy (AMiBA) were modeled based on photogrammetry data with about 20 mount pointing positions. We then used the differential optical pointing error between two optical telescopes to fit the model parameters in the entire horizontal coordinate space. With the platform deformation model, we can predict the errors of the geometric phase delays due to platform deformation with a given azimuth and elevation of the targets and calibrators. After correcting the phases of the radio point sources in the AMiBA interferometric data, we recover 50%-70% flux loss due to phase errors. This allows us to restore more than 90% of a source flux. The method outlined in this work is not only applicable to the correction of deformation for other coplanar telescopes but also to single-dish telescopes with deformation problems. This work also forms the basis of the upcoming science results of AMiBA-13.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Turbulent Mixing of Multiphase Flow

Thus we conduct numerical simulations of multiphase fluids stirred by two-dimensional turbulence to assess the possibility of self-similar drop size distribution in turbulence. In our turbulence simulations, we also explore the non-diffusive limit, where molecular mobility for the interface is vanishing. Special care is needed to transport the non-diffusive interface. Numerically, we use the particle level set method to evolve the interface. Instead of using the usual methods to calculate the surface tension force from the level set function, we reconstruct the interface based on phase- field modeling, and calculate the continuum surface tension forcing from the reconstructed interface.

Young, Y.-N.↗

Phase Screen Determination for the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency airborne radar interferometric mapping instrument designed to obtain high resolution and high accuracy digital elevation models. The X-band inteferometric antennas are mounted beneath the fuselage with a separation distance of 2.6 m. Midway between the antennas along the aircraft centerline is a large fairing housing the Laser Baseline metrology System (LBMS) and Inertial Navigtion Units (INUs). The P-band antennas are mounted in wingtip pods approximately 10 m from the aircraft centerline. Multipath signals reflected from the LBMS fairing cause phase distortions corrupting the topograhic height measurements for both the X-band and P-band systems. In addition multipath off the wing affects the P-band phase measurements. In this paper we discuss a technique used to mitigate the amount of X-Band multipath and methods calibrating and correcting the phase for both X-Band and P-Band using a high accuracy DEM. Height differences between the interferometrically derived elevations and a photogrammetrically derived DEM are converted into phase differences. Multipath phase errors are sinusoidal with spatial frequency and amplitude related to the magnitude of reflection of the multipath reflection point and its distance from the interferometric antennas. These phase residuals are fitted using a Chebyshev polynomial sequence and used as a phase screen in the processor to correct the phase prior to height reconstruction. Based on the correction signal it is possible to estimate the location and magnitude of the multipath signal. This information can then be used to extend the domain of the phase screen over mapping angles not covered during the calibration passes. Keywords: SAR,interferometry,phase screen

Hensley, Scott↗

Markerless tracking of small lung tumors for stereotactic radiotherapy

Purpose: (1) To validate retrospective markerless tracking software for small lung tumors by comparing tracked motion in 4-dimensional planning computed tomography (4DCT) derived kV projection images and known tumor motion in the same 4DCT. (2) To evaluate variability of tumor motion using kV projection images from cone-beam computed tomography (CBCT) scans acquired on different days. Methods: Nonclinical tumor tracking software (TTS) used a normalized cross correlation algorithm to track the tumor on enhanced kV projection images (e.g., from a CBCT scan). The reference dataset consisted of digitally reconstructed radiographs (DRRs) from one phase of a planning 4DCT. TTS matches two in-plane coordinates and obtains the out-of-plane coordinate by triangulating with match results from other projections. (1) To validate TTS, tracking results were compared with known 4DCT tumor motion for two patients (A and B). Projection images (1 image/1°) were digitally reconstructed for each 4DCT phase. From these, kV projection series were composed simulating full breathing cycles every 20° of gantry rotation [breathing period = 20°/(6°/s) = 3.33 s]. Reference templates were 360 “tumor enhanced” DRRs from the 4DCT expiration phase. TTS-derived tumor motion was compared to known tumor motion on 4DCT. (2) For five patients, TTS-assessed motion during clinical CBCT acquisition was compared with motion on the planning 4DCT, and the motion component in the Y (cranio–caudal)-direction was compared with the motion of an external marker box (RPM, real-time position management). Results: (1) Validation results: TTS for case A (tumor 6.2 cm{sup 3}, 32 mm axial diameter) over 360° showed mean motion X (medial–lateral) = 3.4, Y = 11.5, and Z (ventral–dorsal) = 4.9 mm (1 SD < 1.0 mm). Corresponding 4DCT motion was X = 3.1, Y = 11.3, and Z = 5.1 mm. Correlation coefficients between TTS tumor motion and displacement of the tumor’s center of mass (CoM) on 4DCT were 0.64, 0.96, and 0.82 (X, Y, and Z, respectively). For case B (4.1 cm{sup 3}, 20 mm diameter), due to temporarily decreased tumor visibility preventing TTS from resolving the tumor, robust tracking data were only available between angles 300°–40° and 120°–220°. Mean motion according to TTS was X = 2.0, Y = 7.7, and Z = 8.2 mm (1 SD < 0.9 mm). Tumor motion on 4DCT was X = 1.8, Y = 7.6, and Z = 9.5 mm and correlation coefficients between TTS motion and CoM displacement were 0.59, 0.95, and 0.93 (X, Y, and Z, respectively). (2) Clinical results: TTS revealed a mean intrafraction variation in tumor motion in Y-direction of >2.0 mm (1 SD) in four of five patients. In addition, clinical tumor motion amplitude differed from that seen on planning 4DCT. Internal and external structures that create abrupt density change (e.g., table-top edge, interface between lung/mediastinum and lung/heart) were observed to prevent 360° tracking of the tumor. Correlation coefficients between TTS motion in the Y-direction and the RPM signal (22 observations) ranged from 0.78 to 0.96. In 2D, 241 TTS matches at end-inspiration and end-expiration were visually validated: mean difference was 0.8 mm (SD = 0.7) for both. Conclusions: TTS can track small lung tumors if these are visible in kV projections. A 4DCT dataset can be used to validate kV tracking of moving targets. TTS and 4DCT displacement agreed to within 2 mm. TTS and RPM motion were closely associated but tumor motion during CBCT can vary from the planning 4DCT.

60 APPLIED LIFE SCIENCES↗

Region-of-Interest Tomography for Grating-Based X-Ray Differential Phase-Contrast Imaging

We report numerical and experimental results demonstrating accurate region-of-interest computed tomography (CT) reconstruction based on differential phase-contrast projection (DPC) images. The approach removes the constraint of covering the entire sample within the field of view of the image detector. Particularly for biomedical applications, the presented DPC-CT region-of-interest approach will allow for the visualization of previously inaccessible details deep inside an entire animal or organ. We envisage that this development will also be of interest for potential future clinical applications, because grating-based DPC-CT can be implemented with standard x-ray tube sources.

60 APPLIED LIFE SCIENCES↗

Evaluation of intrinsic respiratory signal determination methods for 4D CBCT adapted for mice

Purpose: 4D CT imaging in mice is important in a variety of areas including studies of lung function and tumor motion. A necessary step in 4D imaging is obtaining a respiratory signal, which can be done through an external system or intrinsically through the projection images. A number of methods have been developed that can successfully determine the respiratory signal from cone-beam projection images of humans, however only a few have been utilized in a preclinical setting and most of these rely on step-and-shoot style imaging. The purpose of this work is to assess and make adaptions of several successful methods developed for humans for an image-guided preclinical radiation therapy system. Methods: Respiratory signals were determined from the projection images of free-breathing mice scanned on the X-RAD system using four methods: the so-called Amsterdam shroud method, a method based on the phase of the Fourier transform, a pixel intensity method, and a center of mass method. The Amsterdam shroud method was modified so the sharp inspiration peaks associated with anesthetized mouse breathing could be detected. Respiratory signals were used to sort projections into phase bins and 4D images were reconstructed. Error and standard deviation in the assignment of phase bins for the four methods compared to a manual method considered to be ground truth were calculated for a range of region of interest (ROI) sizes. Qualitative comparisons were additionally made between the 4D images obtained using each of the methods and the manual method. Results: 4D images were successfully created for all mice with each of the respiratory signal extraction methods. Only minimal qualitative differences were noted between each of the methods and the manual method. The average error (and standard deviation) in phase bin assignment was 0.24 ± 0.08 (0.49 ± 0.11) phase bins for the Fourier transform method, 0.09 ± 0.03 (0.31 ± 0.08) phase bins for the modified Amsterdam shroud method, 0.09 ± 0.02 (0.33 ± 0.07) phase bins for the intensity method, and 0.37 ± 0.10 (0.57 ± 0.08) phase bins for the center of mass method. Little dependence on ROI size was noted for the modified Amsterdam shroud and intensity methods while the Fourier transform and center of mass methods showed a noticeable dependence on the ROI size. Conclusions: The modified Amsterdam shroud, Fourier transform, and intensity respiratory signal methods are sufficiently accurate to be used for 4D imaging on the X-RAD system and show improvement over the existing center of mass method. The intensity and modified Amsterdam shroud methods are recommended due to their high accuracy and low dependence on ROI size.

60 APPLIED LIFE SCIENCES↗

Phase-retrieval algorithm for the characterization of broadband single attosecond pulses

Recent progress in high-order harmonic generation with few-cycle mid-infrared wavelength lasers has pushed light pulses into the water-window region and beyond. These pulses have the bandwidth to support single attosecond pulses down to a few tens of attoseconds. However, the present available techniques for attosecond pulse measurement are not applicable to such pulses. Here we report a phase-retrieval method using the standard photoelectron streaking technique where an attosecond pulse is converted into its electron replica through photoionization of atoms in the presence of a time-delayed infrared laser. The iterative algorithm allows accurate reconstruction of the spectral phase of light pulses, from the extreme-ultraviolet (XUV) to soft x-rays, with pulse durations from hundreds down to a few tens of attoseconds. At the same time, the streaking laser fields, including short pulses that span a few octaves, can also be accurately retrieved. Furthermore, such well-characterized single attosecond pulses in the XUV to the soft-x-ray region are required for time-resolved probing of inner-shell electronic dynamics of matter at their own timescale of a few tens of attoseconds.

74 ATOMIC AND MOLECULAR PHYSICS↗

Reconstruction of simulated electrostatic potentials by automatic differentiation-based phase retrieval in electron microscopy imaging

Measuring interfacial electrostatic potentials is vital to understanding many fundamental materials properties. A variety of TEM methods exist for measuring electric potentials from the phase shift produced on an electron wave as it passes through a sample. However, most are either experimentally challenging or poorly suited to resolving nanoscale features. Here, we demonstrate the viability of a simple, automatic differentiation-based exit wave reconstruction from a focal series of images to accurately measure nanoscale electric potentials. Here, the analysis suggests that under optimal measurement conditions, electric potentials can be resolved to less than 0.06 V in magnitude and less than 1 nm in spatial extent.

36 MATERIALS SCIENCE↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

MO-FG-204-05: Evaluation of a Novel Algorithm for Improved 4DCT Resolution

Purpose: Accurate tumor motion characterization is critical for increasing the therapeutic ratio of radiation therapy. To accommodate the divergent fan-beam geometry of the scanner, the current 4D-CT algorithm utilizes a larger temporal window to ensure that pixel values are valid throughout the entire FOV. To minimize the impact on temporal resolution, a cos{sup 2} weighting is employed. We propose a novel exponential weighting (“exponential”) 4DCT reconstruction algorithm that has a sharper slope and provides a more optimal temporal resolution. Methods: A respiratory motion platform translated a lung-mimicking Styrofoam slab with several high and low-contrast inserts 2 cm in the superior-inferior direction. Breathing rates (10–15 bpm) and couch pitch (0.06–0.1 A.U.) were varied to assess interplay between parameters. Multi-slice helical 4DCTs were acquired with 0.5 sec gantry rotation and data were reconstructed with cos{sup 2} and exponential weighting. Mean and standard deviation were calculated via region of interest analysis. Intensity profiles evaluated object boundaries. Retrospective raw data reconstructions were performed for both 4DCT algorithms for 3 liver and lung cancer patients. Image quality (temporal blurring/sharpness) and subtraction images were compared between reconstructions. Results: In the phantom, profile analysis revealed that sharper boundaries were obtained with exponential reconstructions at transitioning breathing phases (i.e. mid-inhale or mid-exhale). Reductions in full-width half maximum were ∼1 mm in the superior-inferior direction and appreciable sharpness could be observed in difference maps. This reduction also yielded a slight reduction in target volume between reconstruction algorithms. For patient cases, coronal views showed less blurring at object boundaries and local intensity differences near the tumor and diaphragm with exponential weighted reconstruction. Conclusion: Exponential weighted 4DCT offers potential for improving image sharpness in 4DCT. Comparisons with true object extent using static CTs of varied phantom positions are necessary to confirm these findings. Future work with additional patient cases is warranted. Research partially sponsored by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-06: A Novel Retrospective 3D K-Space Sorting 4D-MRI Technique Using a Radial K-Space Acquisition MRI Sequence

Purpose: Current retrospective 4D-MRI provides superior tumor-to-tissue contrast and accurate respiratory motion information for radiotherapy motion management. The developed 4D-MRI techniques based on 2D-MRI image sorting require a high frame-rate of the MR sequences. However, several MRI sequences provide excellent image quality but have low frame-rate. This study aims at developing a novel retrospective 3D k-space sorting 4D-MRI technique using radial k-space acquisition MRI sequences to improve 4D-MRI image quality and temporal-resolution for imaging irregular organ/tumor respiratory motion. Methods: The method is based on a RF-spoiled, steady-state, gradient-recalled sequence with minimal echo time. A 3D radial k-space data acquisition trajectory was used for sampling the datasets. Each radial spoke readout data line starts from the 3D center of Field-of-View. Respiratory signal can be extracted from the k-space center data point of each spoke. The spoke data was sorted based on its self-synchronized respiratory signal using phase sorting. Subsequently, 3D reconstruction was conducted to generate the time-resolved 4D-MRI images. As a feasibility study, this technique was implemented on a digital human phantom XCAT. The respiratory motion was controlled by an irregular motion profile. To validate using k-space center data as a respiratory surrogate, we compared it with the XCAT input controlling breathing profile. Tumor motion trajectories measured on reconstructed 4D-MRI were compared to the average input trajectory. The mean absolute amplitude difference (D) was calculated. Results: The signal extracted from k-space center data matches well with the input controlling respiratory profile of XCAT. The relative amplitude error was 8.6% and the relative phase error was 3.5%. XCAT 4D-MRI demonstrated a clear motion pattern with little serrated artifacts. D of tumor trajectories was 0.21mm, 0.23mm and 0.23mm in SI, AP and ML directions, respectively. Conclusion: A novel retrospective 3D k-space sorting 4D-MRI technique has been developed and evaluated on human digital phantom. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

4D cone beam CT via spatiotemporal tensor framelet

Purpose: On-board 4D cone beam CT (4DCBCT) offers respiratory phase-resolved volumetric imaging, and improves the accuracy of target localization in image guided radiation therapy. However, the clinical utility of this technique has been greatly impeded by its degraded image quality, prolonged imaging time, and increased imaging dose. The purpose of this letter is to develop a novel iterative 4DCBCT reconstruction method for improved image quality, increased imaging speed, and reduced imaging dose. Methods: The essence of this work is to introduce the spatiotemporal tensor framelet (STF), a high-dimensional tensor generalization of the 1D framelet for 4DCBCT, to effectively take into account of highly correlated and redundant features of the patient anatomy during respiration, in a multilevel fashion with multibasis sparsifying transform. The STF-based algorithm is implemented on a GPU platform for improved computational efficiency. To evaluate the method, 4DCBCT full-fan scans were acquired within 30 s, with a gantry rotation of 200°; STF is also compared with a state-of-art reconstruction method via spatiotemporal total variation regularization. Results: Both the simulation and experimental results demonstrate that STF-based reconstruction achieved superior image quality. The reconstruction of 20 respiratory phases took less than 10 min on an NVIDIA Tesla C2070 GPU card. The STF codes are available at https://sites.google.com/site/spatiotemporaltensorframelet . Conclusions: By effectively utilizing the spatiotemporal coherence of the patient anatomy among different respiratory phases in a multilevel fashion with multibasis sparsifying transform, the proposed STF method potentially enables fast and low-dose 4DCBCT with improved image quality.

60 APPLIED LIFE SCIENCES↗

An experimental study on the static and dynamic characteristics of pump annular seals with two phase flow

A new test apparatus is reconstructed and is applied to investigate static and dynamic characteristics of annular seals leaked by two phase flow (gas and liquid) for turbopumps. The fluid forces acting on the seals are measured for various parameters such as void ratio, the preswirl velocity, the pressure difference between the inlet and outlet of the seal, the whirling amplitude, and the ratio of whirling speed to spinning speed of the rotor. Influence of these parameters on the static and dynamic characteristics is investigated from the experimental results. As a result, with regard to the two phase flow, as the void ratio increases, the flow induced force decreases. Another dynamic characteristic of two phase flow is as almost similar as that of the monophase flow.

Iwatsubo, T.↗