Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Properties, Propagation, and Excitation of EMIC Waves Properties, Propagation, and Excitation of EMIC Waves

Electromagnetic ion cyclotron (EMIC) waves (0.1-5 Hz) play an important role in particle dynamics in the Earth's magnetosphere. EMIC waves are preferentially excited in regions where hot anisotropic ions and cold dense plasma populations spatially overlap. While the generation region of EMIC waves is usually on or near the magnetic equatorial plane in the inner magnetosphere, EMIC waves have both equatorial and off-equator source regions on the dayside in the compressed outer magnetosphere. Using field and plasma measurements from the Magnetospheric Multiscale (MMS) mission, we perform a case study of EMIC waves and associated local plasma conditions observed on 19 October 2015. From 0315 to 0810 UT, before crossing the magnetopause into the magnetosheath, all four MMS spacecraft detected long-lasting He(exp +)-band EMIC wave emissions around local noon (MLT = 12.7 - 14.0) at high L-shells (L = 8.8 - 15.2) and low magnetic latitudes (MLAT = -21.8deg - -30.3deg). Energetic (greater than 1 keV) and anisotropic ions were present throughout this event that was in the recovery phase of a weak geomagnetic storm (min. Dst = -48 nT at 1000 UT on 18 October 2015). The testing of linear theory suggests that the EMIC waves were excited locally. Although the wave event is dominated by small normal angles, its polarization is mixed with right- and left-handedness and its propagation is bi-directional with regard to the background magnetic field. The short inter-spacecraft distances (as low as ~15 km) of the MMS mission make it possible to accurately determine the k vector of the waves using the phase difference technique. Preliminary analysis finds that the k vector magnitude, phase speed, and wavelength of the 0.3-Hz wave packet at 0453:55 UT are 0.005 km(exp -1), 372.9 km/s, and 1242.9 km, respectively.

Zhang, Jichun↗

Benzo[a]pyrene (BaP) metabolites predominant in human plasma following escalating oral micro-dosing with [ 14 C]-BaP

Benzo[a]pyrene (BaP) is formed by incomplete combustion of organic materials (petroleum, coal, tobacco, etc.). BaP is designated by the International Agency for Research on Cancer as a group 1 known human carcinogen; a classification supported by numerous studies in preclinical models and epidemiology studies of exposed populations. Risk assessment relies on toxicokinetic and cancer studies in rodents at doses 5–6 orders of magnitude greater than average human uptake. Using a dose–response design at environmentally relevant concentrations, this study follows uptake, metabolism, and elimination of [ 14 C]-BaP in human plasma by employing UPLC - accelerator mass spectrometry (UPLC-AMS). Volunteers were administered 25, 50, 100, and 250 ng (2.7–27 nCi) of [ 14 C]-BaP (with interceding minimum 3-week washout periods) with quantification of parent [ 14 C]-BaP and metabolites in plasma measured over 48 h. [ 14 C]-BaP median T max was 30 min with C max and area under the curve (AUC) approximating dose-dependency. Marked inter-individual variability in plasma pharmacokinetics following a 250 ng dose was seen with 7 volunteers as measured by the C max (8.99 ± 7.08 ng × mL -1 ) and AUC0-48hr (68.6 ± 64.0 fg × hr -1 × mL -1 ). Approximately 3–6% of the [ 14 C] recovered (AUC 0-48 hr ) was parent compound, demonstrating extensive metabolism following oral dosing. Metabolite profiles showed that, even at the earliest time-point (30 min), a substantial percentage of [ 14 C] in plasma was polar BaP metabolites. The best fit modeling approach identified non-compartmental apparent volume of distribution of BaP as significantly increasing as a function of dose (p = 0.004). Bay region tetrols and dihydrodiols predominated, suggesting not only was there extensive first pass metabolism but also potentially bioactivation. AMS enables the study of environmental carcinogens in humans with de minimus risk, allowing for important testing and validation of physiologically based pharmacokinetic models derived from animal data, risk assessment, and the interpretation of data from high-risk occupationally exposed populations.

59 BASIC BIOLOGICAL SCIENCES↗

ISS Charging Hazards and Low Earth Orbit Space Weather Effects

Current collection by high voltage solar arrays on the International Space Station (ISS) drives the vehicle to negative floating potentials in the low Earth orbit daytime plasma environment. Pre-flight predictions of ISS floating potentials Phi greater than |-100 V| suggested a risk for degradation of dielectric thermal control coatings on surfaces in the U.S. sector due to arcing and an electrical shock hazard to astronauts during extravehicular activity (EVA). However, hazard studies conducted by the ISS program have demonstrated that the thermal control material degradation risk is effectively mitigated during the lifetime of the ISS vehicle by a sufficiently large ion collection area present on the vehicle to balance current collection by the solar arrays. To date, crew risk during EVA has been mitigated by operating one of two plasma contactors during EVA to control the vehicle potential within Phi less than or equal to |-40 V| with a backup process requiring reorientation of the solar arrays into a configuration which places the current collection surfaces into wake. This operation minimizes current collection by the solar arrays should the plasma contactors fail. This paper presents an analysis of F-region electron density and temperature variations at low and midlatitudes generated by space weather events to determine what range of conditions represent charging threats to ISS. We first use historical ionospheric plasma measurements from spacecraft operating at altitudes relevant to the 51.6 degree inclination ISS orbit to provide an extensive database of F-region plasma conditions over a variety of solar cycle conditions. Then, the statistical results from the historical data are compared to more recent in-situ measurements from the Floating Potential Measurement Unit (FPMU) operating on ISS in a campaign mode since its installation in August, 2006.

Minow, Joseph↗

The structure of a cometary type I tail - Ground-based and ICE observations of P/Giacobini-Zinner

Comparison of ground-based and in situ observations of P/Giacobini-Zinner are used to investigate the morphology of a type I cometary tail. ICE magnetic field and plasma measurements show a well-defined cometary magnetotail composed of two magnetic lobes in pressure equilibrium with a central plasma sheet. A dependence of ion tail width on IMF direction is found which strongly suggests that the classical type I ion tails observed on the ground consist predominantly of emissions from the slab-shaped plasma sheet separating the magnetic lobes. The width of the G-Z magnetotail is determined to be 9.8 (+ or - 0.5) x 10 to the 3rd km with a quasi-circular cross section. The results of this study also indicate that some of the dynamical thinnings and thickenings observed in long type I tails may be caused by IMF variations changing the angle with which the plasma sheet is viewed at earth.

Slavin, J. A.↗

Radiation and Internal Charging Environments for Thin Dielectrics in Interplanetary Space

Spacecraft designs using solar sails for propulsion or thin membranes to shade instruments from the sun to achieve cryogenic operating temperatures are being considered for a number of missions in the next decades. A common feature of these designs are thin dielectric materials that will be exposed to the solar wind, solar energetic particle events, and the distant magnetotail plasma environments encountered by spacecraft in orbit about the Earth-Sun L2 point. This paper will discuss the relevant radiation and internal charging environments developed to support spacecraft design for both total dose radiation effects as well as dose rate dependent phenomenon, such as internal charging in the solar wind and distant magnetotail environments. We will describe the development of radiation and internal charging environment models based on nearly a complete solar cycle of Ulysses solar wind plasma measurements over a complete range of heliocentric latitudes and the early years of the Geotail mission where distant magnetotail plasma environments were sampled beyond X(sub GSE) = -100 Re to nearly L2 (X(sub GSE) ~-236 Re). Example applications of the environment models are shown to demonstrate the radiation and internal charging environments of thin materials exposed to the interplanetary space plasma environments.

Minow, Joseph I.↗

Absolute electron density fluctuation reconstruction for two-dimensional hydrogen beam emission spectroscopy

Scrape-off layer (SOL) and edge plasma turbulence significantly contribute to the radial particle and heat transport, lowering the plasma confinement and increasing the heat load on the plasma facing components. SOL turbulence is predominantly intermittent, which manifests in the occurrence of isolated density filaments or blobs. Filaments propagate radially outward toward plasma facing components, limiting their lifetime by erosion and sputtering. To characterize this phenomenon in detail, few diagnostic techniques are available. Beam emission spectroscopy is a diagnostic capable of measuring plasma turbulence in both SOL and edge plasmas. Due to the finite lifetime of the excitation states during the beam–plasma interaction and the misalignment between the optics and the magnetic field, spatial smearing is introduced in the measurement. In this paper, a novel method is introduced to overcome this hindering effect by inverting the fluctuation response matrix on an optimally smoothed signal. We show that this method is fast and provides significantly more accurate absolute density fluctuation reconstruction than the direct inversion technique. Here, the presented method is usable for all types of beam emission diagnostics where the spatial resolution is higher than the combined smearing of the atomic physics and the observation.

47 OTHER INSTRUMENTATION↗

Mechanisms of Ionospheric Mass Escape

The dependence of ionospheric O+ escape flux on electromagnetic energy flux and electron precipitation into the ionosphere is derived for a hypothetical ambipolar pick-up process, powered the relative motion of plasmas and neutral upper atmosphere, and by electron precipitation, at heights where the ions are magnetized but influenced by photo-ionization, collisions with gas atoms, ambipolar and centrifugal acceleration. Ion pick-up by the convection electric field produces "ring-beam" or toroidal velocity distributions, as inferred from direct plasma measurements, from observations of the associated waves, and from the spectra of incoherent radar echoes. Ring-beams are unstable to plasma wave growth, resulting in rapid relaxation via transverse velocity diffusion, into transversely accelerated ion populations. Ion escape is substantially facilitated by the ambipolar potential, but is only weakly affected by centrifugal acceleration. If, as cited simulations suggest, ion ring beams relax into non-thermal velocity distributions with characteristic speed equal to the local ion-neutral flow speed, a generalized "Jeans escape" calculation shows that the escape flux of ionospheric O+ increases with Poynting flux and with precipitating electron density in rough agreement with observations.

Moore, T. E.↗

High hydrogen coverage on graphene via low temperature plasma with applied magnetic field

The chemical functionalization of two-dimensional materials is an effective method for tailoring their chemical and electronic properties with encouraging applications in energy, catalysis, and electronics. One exemplary 2D material with remarkable properties, graphene, can be exploited for hydrogen storage and large on/off ratio devices by hydrogen termination. In this work, we describe a promising plasma-based method to provide high hydrogen coverage on graphene. A low pressure (~10 mtorr) discharge generates a fine-tunable low-temperature hydrogen-rich plasma in the applied radial electric and axial magnetic fields. Post-run characterization of these samples using Raman spectroscopy and X-ray photoelectron spectroscopy demonstrates a higher hydrogen coverage, 35.8%, than the previously reported results using plasmas. Plasma measurements indicate that with the applied magnetic field, the density of hydrogen atoms can be more than 10 times larger than the density without the magnetic field. With the applied electric field directed away from the graphene substrate, the flux of plasma ions towards this substrate and the ion energy are insufficient to cause measurable damage to the treated 2D material. As a result, the low damage allows a relatively long treatment time of the graphene samples that contributes to the high coverage obtained in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observations of moon-plasma interactions by orbital and surface experiments

Extensive magnetic field observations together with crucial plasma measurements by the Explorer 35 lunar orbiter and Apollo surface and orbital experiments have established the basic nature of the moon's interaction with the solar wind and interplanetary magnetic field. The effective absorption of the incident solar wind by the moon creates a plasma void or cavity behind the moon. The cavity-associated magnetic signature is characterized by an enhancement in magnetic field magnitude B within the cavity as compared with the mean level of B in the surrounding interplanetary plasma and dips or decreases in B near the cavity boundaries with the solar wind. Apollo particle and field measurements on the lunar surface have provided evidence of a regional interaction of the highly conducting solar wind with lunar remanent magnetic fields. Simultaneous plasma and magnetic field data, from the spectrometer and the lunar surface magnetometer at the Apollo 12 location, show the compression of the local remanent field by large solar wind and magnetosheath plasma dynamic pressures.

Schubert, G.↗

STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of the temperature pressure and plasma

Designed to withstand the thermal extremes of the STS-3 mission through the use of heaters and thermal blankets, the plasma diagnostics package sat on the release/engagement mechanism on the OSS-1 payload pallet without a coldplate and was attached to the RMS for two extended periods. Plots show temperature versus mission elapsed time for two temperature sensors. Pressure in the range of 10 to the -3 power torr and 10 to the -7 power torr, measured 3 inches from the skin of the package is plotted against GMT during the mission. The most distinctive feature of the pressure profile is the modulation at the obit period. It was found that pressure peaks when the atmospheric gas is rammed into the cargo bay. Electric and magnetic noise spectra and time variability due to orbiter systems, UHF and S-band transmitter field strengths, and measurements of the ion spectra obtained both in the cargo bay and during experiments are plotted.

Shawhan, S. D.↗

Plasma diagnostics package measurements of ionospheric ions and Shuttle-induced perturbations

The plasma diagnostics package (PDP) on the Space Shuttle STS-3 mission in March 1982 carried among its instrument complement a retarding potential analyzer. This instrument measured both the ambient ion plasma density and temperature, and perturbations to the plasma produced by Shuttle Orbiter effects. Whenever the plasma flow streamline at the instrument was more than a distance of the order of thermal ion gyroradii away from any Orbiter surface, the measurements were characteristic of the ambient ionosphere. In several situations, the PDP was positioned so as to scan the wake in the plasma flow produced by Orbiter surfaces. The density profile of the major species O(+) was consistent with a classic Mach cone. However, strong perturbations extended for several meters outside the Mach cone, which resulted in failure of flowing Maxwellian distributions to represent the data. Configurations where the plasma-flow-impacted Orbiter surfaced downstream of the PDP resulted in generation of a suprathermal ion component. The observations are discussed in terms of a recent model of the mechanism for generation of Shuttle glow.

Reasoner, David L.↗

Cold plasma heating in the plasma sheet boundary layer - Theory and simulations

Satellite observations in recent years have confirmed that the plasma sheet boundary layer is a permanent feature of the earth's magnetotail located between the lobe and central plasma sheet during both quiet and active magnetic periods. Distinct features of the boundary layer include field aligned ion beams and intense electrostatic emissions known as broadband electrostatic noise. Since the plasma sheet boundary layer is a spatial feature of the magnetotail, within it will occur thermal mixing of the resident warm boundary layer plasma with inflowing (convecting) cold ionospheric plasma. A theoretical study involving linear theory and nonlinear numerical particle simulations is presented which examines ion beam instabilities in the presence of a thermally mixed hot and cold background plasma. It is found that the free energy in the ion beams can heat the cool ionospheric plasma to ambient plasma sheet boundary layer temperatures via broadband electrostatic noise. These results, along with recent observational reports that ionospheric outflow can account for measured plasma sheet densities, suggest that the ionospheric role in plasma sheet dynamics and content may be as large as the solar wind.

Schriver, David↗

Three-dimensional measurements of fundamental plasma parameters in pulsed ICP operation

Radio frequency inductively coupled plasma sources are widely used in low temperature industrial processing. Recent computer simulations and experiments indicate significant improvement in processing results with the use of pulsed plasmas. We report three dimensional spatial and temporal measurements of fundamental plasma parameters in a pulsed Argon plasma in an industrial etch tool modified for diagnostic access. The pulse repetition rate is 1 kHz with 50% duty cycle. The density does not decay to zero at the end of the afterglow period, and this affects the initial conditions for the beginning of the next powered phase. At 5 mTorr, the plasma starts in the E-mode for each pulse and grows into a “ring” shape density profile. Subsequently, the profile evolves to peak in the middle of the chamber as it reaches a steady state toward the end of the active-glow. At 25 mTorr, the plasma density profile always peaks at the center of the chamber throughout the entire pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microphysics of the auroral acceleration region of other regions of the magnetosphere

Electric field and plasma measurements pertinent to the microphysics of the auroral acceleration region are reviewed. Observations in other regions of the magnetosphere, which appear to involve similar physical processes, are summarized in order to emphasize the requirement on Cluster instrumentation for wide dynamic range, high time resolution, time domain field, and particle measurements. It is suggested that the microphysics of current driven instabilities in the auroral acceleration region is duplicated in the high latitude boundary of the plasma sheet and that the macroscale structure of the tail is determined by this microphysics.

Mozer, F. S.↗

Efficiency Analysis of a High-Specific Impulse Hall Thruster

Performance and plasma measurements of the high-specific impulse NASA-173Mv2 Hall thruster were analyzed using a phenomenological performance model that accounts for a partially-ionized plasma containing multiply-charged ions. Between discharge voltages of 300 to 900 V, the results showed that although the net decrease of efficiency due to multiply-charged ions was only 1.5 to 3.0 percent, the effects of multiply-charged ions on the ion and electron currents could not be neglected. Between 300 to 900 V, the increase of the discharge current was attributed to the increasing fraction of multiply-charged ions, while the maximum deviation of the electron current from its average value was only +5/-14 percent. These findings revealed how efficient operation at high-specific impulse was enabled through the regulation of the electron current with the applied magnetic field. Between 300 to 900 V, the voltage utilization ranged from 89 to 97 percent, the mass utilization from 86 to 90 percent, and the current utilization from 77 to 81 percent. Therefore, the anode efficiency was largely determined by the current utilization. The electron Hall parameter was nearly constant with voltage, decreasing from an average of 210 at 300 V to an average of 160 between 400 to 900 V. These results confirmed our claim that efficient operation can be achieved only over a limited range of Hall parameters.

Jacobson, David↗

Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.

atmospheric pressure plasma↗