Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plutonium Simulants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Systematic effects in neutron coincidence and multiplicity counting

Correlated neutron counting, including neutron coincidence and multiplicity counting, is an important tool in nuclear material accountancy verification. The accuracy of such measurements is of interest to the safeguards community because as the accuracy of NDA improves, the number of samples that are required to undergo destructive analysis (DA) decreases. The accuracy of a neutron mUltiplicity measurement can be affected by a number of variables. Monte Carlo neutron transport simulations with MCNPX have been performed to understand how the properties of the sample affect the count rate. These resultant count rates have been analyzed with the 'point model' in order to determine the effect on the deduced plutonium mass. The sample properties that have been investigated are density, sample position within the detector cavity, moisture content, isotopic composition, plutonium to total actinide ratio and heavy metal fraction. These parameters affect the Singles, Doubles and Triples count rates in different ways. In addition, different analysis methods use these measured quantities in different combinations, so that the final sensitivity of the {sup 240}Pu mass to each parameter also depends on the analysis method used. For example, the passive calibration curve method only used the Doubles rate to produce the {sup 240}Pu mass and so is not sensitive to changes in the Singles rate (to first order). The analysis methods considered here were passive calibration curve (non-multiplication corrected), known alpha (multiplication corrected) and multiplicity with known efficiency. The effects were studied on both a small mass MOX sample (1 g Pu) and a large MOX sample (6000 g Pu) both measured in high efficiency neutron multiplicity counters. In order to determine the final effect of each parameter it is necessary to know not only the sensitivity of the plutonium mass to that parameter, but also the range over which the parameter can realistically vary. Some estimates are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Melting temperatures of the ZrO{sub 2}-MOX system

Severe accidents occurred at the Fukushima Daiichi Nuclear Power Plant Units 1-3 on March 11, 2011. MOX fuels were loaded in the Unit 3. For the thermal analysis of the severe accident, melting temperature and phase state of MOX corium were investigated. The simulated coriums were prepared from 4%Pu-containing MOX, 8%Pu-containing MOX and ZrO{sub 2}. Then X-ray diffraction, density and melting temperature measurements were carried out as a function of zirconium and plutonium contents. The cubic phase was observed in the 25%Zr-containing corium and the tetragonal phase was observed in the 50% and 75%Zr-containing coria. The lattice parameter and density monotonically changed with Pu content. Melting temperature increased with increasing Pu content; melting temperature were estimated to be 2932 K for 4%Pu MOX corium and 3012 K for 8%Pu MOX corium in the 25%ZrO{sub 2}-MOX system. The lowest melting temperature was observed for 50%Zr-containing corium. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring key Sm isotope ratios in irradiated UO 2 for use in plutonium discrimination nuclear forensics

As part of an experimental validation of a nuclear forensics methodology for Pu source reactor-type discrimination, destructive analysis has been performed here on two irradiated UO 2 pellets with different irradiation histories. Analysis has focused on measuring key Sm fission product isotope ratios used in a previously published maximum likelihood methodology to determine the most likely irradiation history of the pellets. A total of 21 Sm isotope ratios were measured within the irradiated pellets, and generally agreed within 20% of the irradiations as simulated using the Monte Carlo Radiation Transport and material depletion code, MCNP6. Results indicate the chosen approach can accurately measure the isotope ratios within 5% experimental error.

07 ISOTOPE AND RADIATION SOURCES↗

Atomistic Modeling of the Negative Thermal Expansion in δ- Plutonium Based on the Two-State Description

The δ phase of plutonium with the fcc structure exhibits an unusual negative thermal expansion (NTE) over its narrow temperature range of stability, 593–736 K. An accurate description of the anomalous high-temperature volume effect of plutonium goes beyond the current capability of electronic-structure calculations. We propose an atomistic scheme to model the thermodynamic properties of δ-Pu based on the two-state model of Weiss for the Invar alloys, inspired by the simple free-energy analysis previously conducted by Lawson et al. The two-state mechanism is incorporated into the atomistic description of a many-body interacting system. Two modified embedded atom method potentials are employed to represent the binding energies of two competing electronic states in δ-Pu. We demonstrate how the NTE takes place in δ-Pu by means of Monte Carlo simulations implemented with the two-state mechanism.

36 MATERIALS SCIENCE↗

Temperature sensitivity of the equilibrium neutronics and accident analysis of the HTR-10

Pebble-Bed High-Temperature Gas-cooled Reactors (PB-HTGR) are moderated by the graphite in the fuel pebbles and the graphite reflector surrounding the pebble-bed. Because graphite is by far the most abundant material in PB-HTGRs and the primary moderator, accurate modeling of the graphite material, including density, impurities, and temperatures, is crucial for accurate computational modeling and simulation of these reactors. While main characteristics of the graphite components are often known, the local temperature is less well known and often averaged over all components. Here, this work studies the impact of considering accurate temperature profiles in the graphite material on the generation of a small PB-HTGR model at the state of equilibrium operation and on short-term accident progression. The fuel compositions for the PB-HTGR were determined using a jump-in equilibrium modeling method, the Axial Radial Zone Equilibrium Modeling (AR-ZEM) method. In contrast to previous work, the AR-ZEM method was used considering thermal-hydraulic feedback from the MELCOR code to determine temperatures of the fuel pebbles and the surrounding graphite reflector. The consideration of an axial and radial temperature profile in the core and reflector, as opposed to uniform material temperatures, had an impact of almost 1,300 pcm on the equilibrium core eigenvalue and caused significant differences in the discharged plutonium fuel inventory with up to 4.9% and 11.0% for Pu-239 and Pu-242, respectively. To assess the impact on short-term accident progression, two Anticipated Transient Without SCRAM (ATWS) events, a Pressurized Loss of Forced Coolant (PLOFC) and a Control Rod Withdrawal (CRW) with loss of flow, were simulated with MELCOR. The use of temperature profiles in the equilibrium core models did not reveal a significant impact on the temperature, power, or reactivity responses during the transients. In conclusion, a need for consideration of accurate temperature profiles, in particular for the graphite reflector, was found for the generation of equilibrium PB-HTGRs core models using jump-in methods, but detailed temperature profiles may not be necessary when performing conservative transient analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Passive Gamma Spectroscopy to Verify Spent Nuclear Fuel Content

Measurement of passive gamma rays emitted by the decay of radioactive isotopes is a widely used and fundamental technique to verify and determine characteristics of nuclear materials. Several initiatives are currently under way to investigate the use of advanced nondestructive assay methods for application to independently measure the fissile material and plutonium content in spent nuclear fuel. Although no single technique is capable of accurately measuring the actinide inventory, the integration of multiple measures has the potential to dramatically improve nondestructive analysis capability. These methods are likely to involve the use of high-resolution gamma detectors with the resolving power necessary for isotopic identification. Recent high-resolution gamma-ray spectroscopy measurements of spent nuclear fuel rod segments performed at Oak Ridge National Laboratory provided an important opportunity to analyze and identify the dominant and minor gamma-ray signatures that can be acquired using conventional HPGe detectors. The spent fuel source and detector spectra were simulated to identify potential low-intensity gamma signatures in the fuel that could be observed with modest improvements in detector capability. The measurements represent important experimental benchmarks for code and detector model simulations that will be needed to better determine advance detector design requirements for spent fuel measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary verification of the MCNP perturbation and fixed-source tally sensitivity tools

Integral benchmark experiments are vital in the adjustment and validation of the nuclear data that govern predictive simulations across the nuclear community. The nuclear data sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®) transport code are currently limited; however, expanding sensitivity capabilities will allow benchmark experiments to be designed to resolve compensating errors and adjust nuclear data where previously prohibitively difficult. This paper provides details of a preliminary verification for the use of (i.) the recently revised perturbation and (ii.) developmental fixed-source sensitivity tools within MCNP to calculate sensitivities of tallied responses (such as current integrated over a surface, F1, and flux averaged over a cell, F4) to nuclear data in fixed-source simulations. Energy-binned and energy-integrated sensitivities calculated with these tools are compared against sensitivities calculated using a central-difference approximation. Here, the verification is completed for four configurations of a benchmarked system using a 4.5-kg plutonium sphere surrounded by varying amounts of copper and/or polyethylene. The results show that sensitivities calculated with the perturbation and fixed-source sensitivity tools agree with the central-difference-based approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermodynamic Properties of Actinide-Zirconium Dioxide Solid-Solutions Relevant for Advanced Nuclear Fuels

Currently, spent nuclear fuel (SNF) from commercial reactors is composed of 95-99% UO{sub 2} and 1-5% fission products and transuranium elements. Thus, the primary waste form is the UO{sub 2} matrix, which over time will corrode to a variety of U(VI)-secondary phases. Alternative nuclear fuels, such as inert-matrix fuels and mixed-oxide fuels, have been studied for their in-reactor performance; however little research has been conducted to understand the behavior of these fuels as a wasteform. We use density functional theory and Monte-Carlo methods to understand the solid solution behavior of (Ac, Zr)O{sub 2} (Ac = Th, U, Np, Pu) phases. The end members of interest include ZrO{sub 2}, ThO{sub 2}, UO{sub 2}, NpO{sub 2}, and PuO{sub 2}, and all share the cubic-fluorite structure. The excess enthalpy of mixing ({delta}H{sub excess}), excess Gibbs free energy of mixing ({delta}G{sub excess}), and excess configurational entropy ({delta}S{sub excess}) are calculated for the above solid solution series, and from {delta}G{sub excess}, miscibility gaps are identified. In conclusion: Density functional theory and Monte Carlo simulations were used in this study to determine the thermodynamic properties of binary oxide solid solutions that are useful for advanced nuclear fuel applications. The DFT results for each solid solution series is of the single cubic unit cell; therefore, only one interaction parameter was calculated. Based on the Monte-Carlo results, on the order of 25% Zr can be incorporated into the AcO{sub 2} structures (Ac = Th, U, Np, or Pu). However, only trace amounts of the actinides can be incorporated into ZrO{sub 2}. Considering larger systems in the DFT calculations will improve results, because more cation-cation interaction parameters can be calculated. Configurational ordering can also be considered with larger systems. Molecular dynamic simulations will be used to determine the temperature dependence of the different solid solutions that is more specific to their respective lattice dynamics. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Access to Special Nuclear Material at the Idaho National Laboratory

Access to special nuclear material (SNM) such as enriched uranium or plutonium is critical to the experimental validation of measurement techniques for nuclear nonproliferation applications. It is especially important that realistic quantities be available for measurements in the field. Security and safety requirements have made such access nearly impossible at many U.S. facilities. The Idaho National Laboratory (INL) has been able to provide kilogram quantities of SNM for in situ measurements ranging from testing of equipment in laboratory facilities, to outdoor measurements simulating real conditions, to transfer of the SNM to the customer’s facility and back for measurements in the field. The INL will be working to make SNM more widely accessible for measurements by nuclear nonproliferation projects, including those with international researchers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors

Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. Furthermore, the Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached to the watch’s minute hand, and as it rotates, more of the underlying source is revealed. The alpha activity we measured increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. We also used data obtained using the Dynamic Radioactive Source to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.

07 ISOTOPE AND RADIATION SOURCES↗

Chabazite Zeolite Membranes for Krypton/Xenon Separation: Control of Membrane Properties and Process Modeling

Nuclear energy is considered to be a clean and economical means of carbon-free energy. As part of the overall process for recycling used nuclear fuel (UNF), it is necessary to develop technologies to separate the off-gases formed during the fission of uranium and plutonium in nuclear power reactors. The off-gas stream is generated during the shearing and chopping, voloxidation, and acid dissolution steps, and would have a flow rate of ∼2500 L/min assuming a typical 800 tons heavy metal/yr reprocessing facility. Kr separation from Xe is one of the steps in a proposed UNF off-gas processing flowsheet. The Kr/Xe mixture is approximately 10/90 by volume and hence the separation of Kr would reduce the volume of radioactive {sup 85}Kr waste by a factor of 10. Kr/Xe separation is challenging since they are both chemically inert species and physically very similar (0.036 nm size difference). There is no existing process for this separation that is suitable for use in UNF recycling since conventional cryogenic distillation requires highly intensive power and large system volume. Membrane-based separation using radiation-stable materials such as zeolites could be an attractive separation method, if membranes with sufficient Kr flux and selectivity can be fabricated. Zeolite membranes offer an opportunity to exploit the size difference of Kr (kinetic diameter 0.36 nm) and Xe (0.396 nm) to achieve preferential permeation of the minority component (Kr) from the mixture, leading to an efficient separation with very low energy requirements. An ideal membrane process would permeate a stream of pure Kr for storage and also produce pure Xe which has commercial value (> $8000/kg at 99+% purity). SAPO-34 is a silico-alumino-phosphate zeolite molecular sieve with CHA framework topology and containing uniform micropores (0.38 nm), intermediate in size between the kinetic diameters of Kr and Xe. It was hypothesized that SAPO-34 membranes can separate krypton and xenon by diffusivity differences. Previously we fabricated SAPO-34 membranes and showed that they are capable of separating Kr from Xe. Our previous work also indicated that there is much potential for engineering the separation properties of these membranes with a view to improving permeance and selectivity and evaluating the expected process performance. The main objectives of the present study are: 1) development of SAPO-34 membranes with enhanced membrane performance via thickness reduction and ion exchange, and 2) process modeling for technic-economic analysis of zeolite membrane systems for Kr/Xe separation.

36 MATERIALS SCIENCE↗

Caustic Precipitation of Plutonium and Uranium with Gadolinium as a Neutron Poison

Here, the caustic precipitation of plutonium (Pu) and uranium (U) from Pu and U containing waste solutions has been investigated to determine whether gadolinium (Gd) could be used as a neutron poison for precipitation with greater than a fissile mass containing both Pu and enriched U. Precipitation experiments were performed using both actual samples and simulant solutions with a range of 2.6-5.16 g/L U and 0-4.3 to 1 U to Pu. Analyses were performed on solutions at intermediate pH to determine the partitioning of elements for accident scenarios. When both Pu and U were present in the solution, precipitation began at pH 4.5 and by pH 7, 99% of Pu and U had precipitated. When complete neutralization was achieved at pH greater than 14 with 1.2 M excess OH - , greater than 99% of Pu, U, and Gd had precipitated. At pH greater than 14, the particles sizes were larger and the distribution was a single mode. The ratio of hydrogen to fissile atoms in the precipitate was determined after both settling and centrifuging and indicates that sufficient water was associated with the precipitates to provide the needed neutron moderation for Gd to prevent a criticality in solutions containing up to 4.3 to 1 U to Pu and up to 5.16 g/L U.

08 HYDROGEN↗

Predicted Radiation Output from Several Kilograms of Plutonium Oxide

Neutron and gamma signatures from 3.44 kg of plutonium oxide were predicted with MCNP6 in anticipation of a passive diagnostic measurement campaign. Calculated radiation fields are visualized through use of “FMESH” type tallies. This work is effectively an extension of previous efforts and application of MISC for the photon source term is the main advancement. Large sources of modeling uncertainty include physical can dimensions and thus internal volume and density estimates. Material age is unknown and will also affect the passive gamma signature. The measurement campaign will provide information for model refinement and subsequent simulations. The authors have requested passive data collection on the pair of cans with the largest and smallest mass and such data will be valuable for benchmarking purposes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Comparison Framework for Reactor Anti-Neutrino Detectors in Near-Field Nuclear Safeguards Applications

Electron anti-neutrino ( e) detectors can support nuclear safeguards, from reactor monitoring to spent fuel characterization. In recent years, the scientific community has developed multiple detector concepts, many of which have been prototyped or deployed for specific measurements by their respective collaborations. However, the diversity of technical approaches, deployment conditions, and analysis techniques complicates direct performance comparison between designs. We have begun development of a simulation framework to compare and evaluate existing and proposed detector designs for nonproliferation applications in a uniform manner. This report demonstrates the intent and capabilities of the framework by evaluating four detector design concepts, calculating generic reactor antineutrino counting sensitivity, and capabilities in a plutonium disposition application example.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutronics Simulations of 237Np Targets to Support Safety-Basis and 238Pu Production Assessment Efforts at the High Flux Isotope Reactor

Fueled by two highly enriched uranium-bearing fuel elements surrounded by a large concentric ring of beryllium reflector, the High Flux Isotope Reactor (HFIR) provides one of the highest neutron fluxes in the world and is used to produce unique isotopes like plutonium-238. The National Aeronautics and Space Administration use radioisotope thermoelectric generators powered by 238Pu for deep-space missions. As part of the US Department of Energy s task to reestablish the domestic production of 238Pu, a technology demonstration sub-project has been initiated to establish a new 238Pu supply chain. HFIR safety-basis neutronics calculations are being performed to ensure the target irradiations have no adverse impacts on reactor performance and to calculate data required as input to follow-on thermal-structural, thermal-hydraulic and radionuclide/dose analyses. Plutonium-238 production assessments are being performed to estimate the amount of 238Pu that can be produced in HFIR s permanent beryllium reflector. It is estimated that a total of 0.96 1.12 kg 238Pu (~1.28 1.49 kg PuO2 at 85% 238Pu/Pu purity) could be produced per year in HFIR s permanent beryllium reflector irradiation facilities if they are all utilized.

depletion↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Evolution of chemical conditions and estimated solubility controls on radionuclides in the residual waste layer during post-closure aging of high-level waste tanks

This document provides information specific to H-Area waste tanks that enables a flow and transport model with limited chemical capabilities to account for varying waste release from the tanks through time. The basis for varying waste release is solubilities of radionuclides that change as pore fluids passing through the waste change in composition. Pore fluid compositions in various stages were generated by simulations of tank grout degradation. The first part of the document describes simulations of the degradation of the reducing grout in post-closure tanks. These simulations assume flow is predominantly through a water saturated porous medium. The infiltrating fluid that reacts with the grout is assumed to be fluid that has passed through the closure cap and into the tank. The results are three stages of degradation referred to as Reduced Region II, Oxidized Region II, and Oxidized Region III. A reaction path model was used so that the transitions between each stage are noted by numbers of pore volumes of infiltrating fluid reacted. The number of pore volumes to each transition can then be converted to time within a flow and transport model. The bottoms of some tanks in H-Area are below the water table requiring a different conceptual model for grout degradation. For these simulations the reacting fluid was assumed to be 10% infiltrate through the closure cap and 90% groundwater. These simulations produce an additional four pore fluid compositions referred to as Conditions A through D and were intended to simulate varying degrees of groundwater influence. The most probable degradation path for the submerged tanks is Condition C to Condition D to Oxidized Region III and eventually to Condition A. Solubilities for Condition A are estimated in the text for use in sensitivity analyses if needed. However, the grout degradation simulations did not include sufficient pore volumes of infiltrating fluid for the grout to evolve to Condition A. Solubility controls for use in a flow and transport model were estimated for 27 elements in each of the chemical stages generated in the grout simulations plus local groundwater. The grout simulations were run with the initial infiltrating fluid in equilibrium with atmospheric oxygen to account for degradation of the reduction capacity of the grout. However, a lower Eh was used in pore fluids in the oxidizing conditions used to estimate solubilities to be more consistent with measured Eh values and natural systems. Solubilities of plutonium are affected by this decision, but those of other elements are not. In addition, the baseline for H-Area tanks is that they will be washed with oxalic acid prior to being filled with grout. Hence, oxalate was included in the pore fluids by assuming equilibrium with calcium oxalate. Solubility estimates were done by equilibrating a solubility controlling phase for each element with the pore fluid compositions using The Geochemist’s Workbench®. Condition B pore fluids are similar to Condition D. Therefore, solubilities for Condition B were not estimated, but assumed to be the same as in Condition D. In general solubility controlling phases were selected to bias solubilities to higher values. Several elements had no solubility controls and solubility estimates for other elements were omitted because the elements had short half-lives or were present in residual waste in very low amounts. For these it is recommended that release from the tank be instantaneous when the tank liner is breached. There is considerable uncertainty in this approach to enabling a flow and transport model to account for variable waste release. Yet, it is also flexible and requires much less computing time than a fully coupled reactive transport model. This allows some of the uncertainty to be addressed by multiple flow and transport sensitivity cases. Some of the uncertainties are addressed within this document. These include uncertainty in infiltrate composition, grout mineralogy, and disposition of certain components during the simulations. Uncertainty in the solubility estimates is addressed in part by examining sensitivity of solubilities for four key elements to uncertainty in thermodynamic data, pH, Eh, total inorganic carbon concentration, and oxalate concentration. In addition, the solubilities for the elements estimated here are compared to two other compilations of solubilities in cementitious materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample Results from the Interim Salt Disposition Program Macrobatch 8 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 8 for the Interim Salt Disposition Program (ISDP). An Actinide Removal Process (ARP) and several Extraction-Scrub- Strip (ESS) tests were also performed. This document reports characterization data on the samples of Tank 21H as well as simulated performance of ARP and the Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU). No issues with the projected Salt Batch 8 strategy are identified. A demonstration of the monosodium titanate (MST) (0.2 g/L) removal of strontium and actinides provided acceptable average decontamination factors for plutonium of 2.62 (4 hour) and 2.90 (8 hour); and average strontium decontamination factors of 21.7 (4 hour) and 21.3 (8 hour). These values are consistent with results from previous salt batch ARP tests. The two ESS tests also showed acceptable performance with extraction distribution ratios (D(Cs)) values of 52.5 and 50.4 for the Next Generation Solvent (NGS) blend (from MCU) and NGS (lab prepared), respectively. These values are consistent with results from previous salt batch ESS tests. Even though the performance is acceptable, SRNL recommends that a model for predicting extraction behavior for cesium removal for the blended solvent and NGS be developed in order to improve our predictive capabilities for the ESS tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗