Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Restoration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Mixed-Mode Decohesion Finite Elements for the Simulation of Delamination in Composite Materials

A new decohesion element with mixed-mode capability is proposed and demonstrated. The element is used at the interface between solid finite elements to model the initiation and non-self-similar growth of delaminations. A single relative displacement-based damage parameter is applied in a softening law to track the damage state of the interface and to prevent the restoration of the cohesive state during unloading. The softening law for mixed-mode delamination propagation can be applied to any mode interaction criterion such as the two-parameter power law or the three-parameter Benzeggagh-Kenane criterion. To demonstrate the accuracy of the predictions and the irreversibility capability of the constitutive law, steady-state delamination growth is simulated for quasistatic loading-unloading cycles of various single mode and mixed-mode delamination test specimens.

Camanho, Pedro P.↗

Quantifying Distribution System Resilience From Utility Data: Large Event Risk and Benefits of Investments

We focus on blackouts in electric distribution systems that have a large cost to customers. To quantify resilience to these events, we show how to calculate risk metrics from the historical outage data routinely collected by utilities' outage management systems. Risk is defined using a customer cost exceedance curve. The exceedance curve has a heavy tail that implies large fluctuations in large blackout costs, and this makes estimating the mean large cost in the usual way impractical. To avoid this problem, we use new resilience metrics describing the large event risk; these metrics are the probability of a large cost event, the annual log cost resilience index, and the average of the logarithm of the cost of large-cost events or the slope magnitude of the tail on a log–log exceedance curve. Resilience can be improved by planned investments to upgrade system components or speed up restoration. The benefits that these investments would have had if they had been made in the past can be quantified by “rerunning history” with the effects of the investment included, and then recalculating the large event risk to find the improvement in resilience. An example using utility data shows a 2% reduction in the probability of a large cost event due to 10% wind hardening and 6%–7% reduction due to 10% faster restoration in two different areas of a distribution utility. This new data-driven approach to quantify resilience and resilience investments is realistic and much easier to apply than complicated approaches based on modeling all the phases of resilience. Moreover, an appeal to improvements to past lived experience may well be persuasive to customers and regulators in making the case for resilience investments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic pre-event preparation for enhancing resilience of distribution systems

Extreme weather events are the common causes for power supply interruptions and power outages in electrical distribution systems. Improving the distribution system and enhancing its resilience is becoming crucial due to the increased frequency of extreme weather events. Preparation and allocation of multiple flexible resources, such as mobile resources, fuel resources, and labor resources before extreme weather events can mitigate the effects of extreme weather events and enhance the resilience of power distribution systems. Here, in this paper, a two-stage stochastic mixed-integer linear programming (SMILP) is proposed to optimize the preparation and resource allocation process for upcoming extreme weather events, which leads to faster and more efficient post-event restoration. The objective of the proposed two-stage SMILP is to maximize the served load and minimize the operating cost of flexible resources. The first stage in the optimization problem selects the amounts and locations of different resources. The second stage considers the operational constraints of the distribution system and repair crew scheduling constraints. The proposed stochastic pre-event preparation model is solved by a scenario decomposition method, Progressive Hedging (PH), to ease the computational complexity introduced by a large number of scenarios. Furthermore, to show the impact of solar photovoltaic (PV) generation on system resilience, three types of PV systems are considered during a power outage and the resilience improvements with different PV penetration levels are compared. Numerical results from simulations on a large-scale (more than 10,000 nodes) distribution feeder have been used to validate the effectiveness and scalability of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-phase flows within systems with ambient pressure

In systems where the design inlet and outlet pressures are maintained above the thermodynamic critical pressure, it is often assumed that two phase flows within the system cannot occur. Designers rely on this simple rule of thumb to circumvent problems associated with a highly compressible two phase flow occurring within the supercritical pressure system along with the uncertainties in rotordynamics, load capacity, heat transfer, fluid mechanics, and thermophysical property variations. The simple rule of thumb is adequate in many low power designs but is inadequate for high performance turbomachines and linear systems, where two phase regions can exist even though outlet pressure is greater than critical pressure. Rotordynamic-fluid-mechanic restoring forces depend on momentum differences, and those for a two phase zone can differ significantly from those for a single-phase zone. Using the Reynolds equation the angular velocity, eccentricity, geometry, and ambient conditions are varied to determine the point of two phase flow incipience.

Hendricks, R. C.↗

Two-Phase Accumulator

Two-phase accumulator maintains pressure and temperature in thermal-bus system within predetermined range during variations in heat load on system. Stores liquid and vapor ammonia. Exchanges liquid ammonia with condenser to adjust level of liquid in condenser. Prototype has capacity of 13 gallons (49 liters). Simple and highly reliable. Responds quickly, restoring pressure and temperature to proper values within minutes. Low in cost and requires little further development. Used to dispose of waste heat, such as that from electronic equipment or power-plant.

Kalb, Charles E.↗

Irradiation By Neutrons And Annealing of SiGe Alloys

Heat treatment restores thermoelectric performance having deteriorated under irradiation by neutrons. Discovery suggests SiGe materials used in radioisotope thermoelectric generators and other applications up to fluences of 5.4 X 10(to the 19th power)cm(to the negative 2nd power) and operating at temperatures of 600 to 1,000 degrees C.

Vandersande, Jan W.↗

CloudSat Anomaly Recovery and Operational Lessons Learned

In April 2011, NASA's pioneering cloud profiling radar satellite, CloudSat, experienced a battery anomaly that placed it into emergency mode and rendered it operations incapable. All initial attempts to recover the spacecraft failed as the resultant power limitations could not support even the lowest power mode. Originally part of a six-satellite constellation known as the "A-Train", CloudSat was unable to stay within its assigned control box, posing a threat to other A-Train satellites. CloudSat needed to exit the constellation, but with the tenuous power profile, conducting maneuvers was very risky. The team was able to execute a complex sequence of operations which recovered control, conducted an orbit lower maneuver, and returned the satellite to safe mode, within one 65 minute sunlit period. During the course of the anomaly recovery, the team developed several bold, innovative operational strategies. Details of the investigation into the root-cause and the multiple approaches to revive CloudSat are examined. Satellite communication and commanding during the anomaly are presented. A radical new system of "Daylight Only Operations" (DO-OP) was developed, which cycles the payload and subsystem components off in tune with earth eclipse entry and exit in order to maintain positive power and thermal profiles. The scientific methodology and operational results behind the graduated testing and ramp-up to DO-OP are analyzed. In November 2011, the CloudSat team successfully restored the vehicle to consistent operational collection of cloud radar data during sunlit portions of the orbit. Lessons learned throughout the six-month return-to-operations recovery effort are discussed and offered for application to other R&D satellites, in the context of on-orbit anomaly resolution efforts.

cloud profiling radar satellite↗

Blockchain for Fault-Tolerant Grid Operations

Distribution system fault/failure has a direct impact on customers. Distribution systems are not designed with the contingency of one or more elements failing as the transmission system, however, distribution systems are more likely to have faults in comparison to transmission and generation systems. Most of the distribution systems have a radial design with the protection system assumption of unidirectional power flow. The radial design results in the disconnection of customers for any given component failure. The rapid deployment of distributed energy resources conflicts with the assumption of unidirectional power flow. To maintain/improve the distribution system fault tolerance for a grid with high penetration of distributed energy resources requires improvement. Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain’s core features of distributed consensus-based decision-making process and immutability. In the process of preparing for an event or system restoration, there is a need for reliable data and system situational awareness. The system situational awareness enables accurate planning for possible scenarios and system restoration after an event, an area where blockchain’s distributed architecture can help. The value of blockchain for a fault-tolerant grid operation is elaborated with three use cases: 1) fault location, isolation, and service restoration; 2) topology identification; and 3) data configuration. These use cases demonstrate how blockchain-based architecture can facilitate bridging the vulnerabilities of the existing implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Mechanical Cryogenic Cooler for the Hubble Space Telescope

This paper presents a description of the Hubble Space Telescope (HST) Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) Cryo Cooler (NCC), the cutting edge technology involved, its evolution, performance, and future space applications. The NCC is the primary hardware component of the NICMOS Cooling System comprised of the NCC, an Electronics Support Module, a Capillary Pumped Loop/Radiator, and associated interface harnessing. The system will be installed during extravehicular activities on HST during Servicing Mission 3B scheduled for launch in February 2002. The NCC will be used to revive the NICMOS instrument, which experienced a reduced operational lifetime due to an internal thermal short in its dewar structure, and restore HST scientific infrared capability to operational status. The NCC is a state-of-the-art reverse Turbo-Brayton cycle cooler employing gas bearing micro turbo machinery, driven by advanced power conversion electronics, operating at speeds up to 7300 revolutions per second (rps) to remove heat from the NICMOS instrument.

Jedrich, Nicholas↗

Microgrid Resilience: A Holistic and Context-Aware Resilience Metric

Microgrids present an effective solution for the coordinated deployment of various distributed energy resources and furthermore provide myriad additional benefits such as resilience, decreased carbon footprint, and reliability to energy consumers and the energy system as a whole. Boosting the resilience of distribution systems is another major benefit of microgrids. This is because they can also serve as a backup power source when the utility grid's operations are interrupted due to either high-probability low-impact events like a component failure or low-probability high-impact events - be it a natural disaster or a planned cyberattack. However, the degree to which any particular system can defend, adapt, and restore normal operation depends on various factors including the type and severity of events to which a microgrid is subjected. These factors, in turn, are dependent on the geographical location of the deployed microgrid as well as the cyber risk profile of the site where the microgrid is operating. Therefore, in this work, we attempt to capture this multi-dimensional interplay of various factors in quantifying the ability of the microgrid to be resilient in these varying aspects. This paper, thus, proposes a customized site-specific quantification of the resilience strength for the individual microgrid's capability to absorb, restore, and adapt to the changing circumstances for sustaining the critical load when a low-probability high-impact event occurs - termed as - context-aware resilience metric. We also present a case study to illustrate the key elements of our integrated analytical approach.

microgrid↗

Synchrophasor spoofing detection and remediation for wide-area damping control

Evolving cyber-attack threats put at risk automatic closed-loop systems to be incorporated in the smart grid. Wide-area control systems are particularly vulnerable to signal spoofing attacks due to sensor remoteness and dependence on satellite communication for time synchronization. A successful cyber-attack on a wide-area controller has the potential to reduce relative stability of the power system or worse, destabilize it. As such, detection algorithms must be deployed as defense against such attacks with the ability to autonomously correct for detected tampering or misoperation. The Spoof Catch and Restore Routine (SCR 2 ), a combination of three real-time spoof detectors, each requiring limited information about the plant, is reported here. Nonlinear simulations of a compromised wide-area control system deployed in the Western Interconnection show the effectiveness of SCR 2 in detecting both delay-type and counterfeit-type spoofing attacks on wide-area sensors.

42 ENGINEERING↗

Secondary Frequency Control for Reconfigurable Interconnecting Microgrids

Microgrids and microgrid technologies offer an operations and control framework for realizing the needed aggregation of a growing share of distributed energy resources. As the number of microgrids increases, so will the incentive to interconnect them, leading to a combinatorial growth of potential operating states. At the same time, their growing complexity nudges interconnected microgrids conceptually closer to balancing authorities in the bulk power system. This paper focuses on secondary frequency control and leverages the conceptual similarity between balancing authorities and interconnected microgrids to adopt an automatic generation control design with some adaptations. Frequency control and restoration is demonstrated via several use-cases with switching and reconfiguration events.

Schweitzer, Eran↗

Going Commercial

while the conditions are more rigorous today for the ISS than they were in the very early days of space travel, opportunities still abound, and we just need to overcome the hurdles. As Pogo put it, "By gosh, we seem to be surrounded by an insurmountable opportunity here." This really is a great time in human spaceflight. We re doing marvelous things up there from an engineering standpoint. We now have to put them to good use. We need to optimize the 30 percent of the ISS that our federal government and the international partners have available in terms of the Station s power, volume, and crew time. Despite the recent issues with cost and schedule, as Mr. Goldin has said, this Agency will find a way. This country and the partners will find a way to restore the ISS s capability. We need help from this government, from our Congress, from our partners to do that, but it will be done, and then this facility is going to be world class--nah, it will out-of-this- world class. I m pleased to be a part of not only the history of spaceflight and the history of industry s participation in spaceflight, but I m also pleased to be a part of the future, the future applications, the future benefits that our spaceflight program is going to bring to our economy, to our careers, and to those of us that are both taxpayers and participants as well, to the great joy of seeing success as part of this country, as a part of our intellect, applied to the great beyond.

Walker, Charles↗

Power Hibernation for Low-Cost Solar Powered Lunar Missions

Because the surface of the Moon drops to cryogenic temperatures, no solar-powered lunar spacecraft have reliably operated beyond a single lunar day. Passive thermal control cannot keep a spacecraft sufficiently warm for the 354-hour lunar night, and active thermal control requires a dramatic increase in battery mass at the expense of payload mass. Extreme conditions seen on the lunar surface suggest a radioisotope solution is ideal, but mass, cost, and schedule are inconsistent with low-cost frequent flight intent of the commercial lunar payload services (CLPS) program. To solve the issue of lunar night survivability without radioisotope sources of power and heat, a lunar power hibernation approach is being developed at the Glenn Research Center, which exploits the ability of common 18650 Lithium-ion cells to passively survive cryogenic freeze-thaw cycles and recover without apparent performance degradation. A key aspect of this hibernation approach is the use of cryogenically operable electronics that safely manage the restoration of the battery thermal environment at lunar dawn. A spacecraft utilizing this strategy will operate into the lunar night on batteries until the state of charge or spacecraft temperature reaches a predetermined threshold. At this point, systems are shut down and the battery is isolated from the main bus to prevent charge or discharge during the freezing and thawing transitions. The system remains passive until lunar dawn, where temperatures can reach as low as 50 K. All electronics must be tolerant to these conditions. When the solar arrays are finally illuminated at lunar dawn, the main bus power electronics will initiate a “cold start” and begin regulating array power. The main bus electronics must be designed to operate at cryogenic temperatures. Array power is used to warm the battery and passive electronics back to operational temperatures. Once batteries are returned to normal temperatures, diagnostics and precharging is performed, as needed, and the battery is reconnected. The overall spacecraft system reboots and returns to nominal operations until lunar night returns. To assure that we can develop batteries suited for many hibernation freeze/thaw cycles, STMD Space Technology Research Grant Program (STRG) has selected two principal investigators that will thoroughly characterize of the Li-ion cell through the freeze-thaw process, investigate degradation mechanisms, and identify potential diagnostic techniques. STMD STRG is also funding an investigation of Gallium-Nitride semiconductors for cryogenic power applications. This work includes physics-informed modeling that considers cryogenic conductivity, carrier mobility, and quantum effects that govern semiconductor performance at cryogenic temperatures. These models can enable engineers to develop accurate cryogenic simulation models that assist in the design of power controls stable over the entire lunar surface temperature range. Meanwhile, Glenn is performing cryogenic testing of batteries and electronics, establishing design guidelines for power applications in extreme cold lunar environment, and potentially developing a hibernation technology demonstrator. The hibernation approach will enable low-cost lunar robotic missions to extend their operating lifetime to many months while minimizing development costs and impact on payload capacity. The need for cryogenically operable electronics is restricted to only main bus power and battery controls, as the majority of systems simply need to passively tolerate cryogenic temperatures. This allows developers to continue to exploit the cost savings of legacy and COTS hardware with minimum modification. For these reasons, lunar power hibernation is a viable near-term solution for lunar night survivability for solar powered commercial landers.

Space power↗

Achieving Productivity to Recover and Restore Columbia River Stream-Type Chinook Salmon Relies on Increasing Smolt-To-Adult Survival

Abstract We analyzed and compared productivity and survival rates of populations of stream-type Chinook Salmon Oncorhynchus tshawytscha from the upper and middle ranges of their distribution in the Columbia River basin. These two groups of populations undergo vastly different exposures during migration through the Federal Columbia River Power System (FCRPS). Declines of the Snake River populations, listed as threatened under the U.S. Endangered Species Act, have been associated with the development and operation of the FCRPS. In contrast, John Day River stream-type Chinook Salmon populations, which were less affected by the FCRPS, have declined to a lesser extent and are not listed. Smolt-to-adult survival rates (SARs) accounted for a majority of the variation in life cycle survival rates of Snake River Chinook Salmon. Productivity declined to 13% and 44% of historical productivity levels for Snake River and John Day River populations, respectively. A synthesis of previous studies contrasting anthropogenic impacts between the two regions supports the conclusion that FCRPS impacts explain the large difference in population productivity. Our results suggest that SARs of 4% would result in an expected productivity of up to 70% of historical levels (a SAR level consistent with regional restoration objectives). The SARs have been shown to be highly influenced by conditions within the FCRPS (e.g., water velocity and passage through dam powerhouses). Marine conditions also influence SARs; however, meaningful management actions are only available to affect conditions within the FCRPS. Given the importance of SARs to overall life cycle productivity, recovery and restoration strategies need to prioritize actions that have potential to substantially increase SARs by addressing the significant impacts of main-stem dams. This study highlights the importance of considering river management options in the face of increasingly variable and warming ocean conditions.

Petrosky, Charles E.↗

Experimental evidence of electron-cyclotron current drive-based neoclassical tearing mode suppression threshold reduction during mode locking on DIII-D

The repetitive locking-unlocking process of a large $m/n = 2/1$ neoclassical tearing mode (NTM) is studied on the DIII-D tokamak. Cyclical periods of partial suppression are achieved when β p and the expected bootstrap current $J_{\mathrm{BS}}$ drop upon back-transitions to L-mode. Diminished L-mode bootstrap current is required to explain decreased island size as modeled by the generalized Rutherford equation. At EC power levels too low to fully suppress the NTM, partial suppression is enough to reduce the torque on the mode to the point where viscous drag from the background plasma overcomes the electromagnetic torque and restores fast plasma rotation and H-mode. Additional current drive is shown to further reduce the size of the mode until full suppression is achieved. These results suggest that the suppression of locked modes may be aided by the lower bootstrap current in L-mode plasmas, possibly improving chances of disruption avoidance in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ferrorotational domain walls revealed by electric quadrupole second harmonic generation microscopy

Domain walls are ubiquitous in materials that undergo phase transitions driven by spontaneous symmetry breaking. Domain walls in ferroics and multiferroics have received tremendous attention recently due to their emergent properties distinct from their domain counterparts—for example, their high mobility and controllability, as well as their potential applications in nanoelectronics. However, it is extremely challenging to detect, visualize, and study the ferrorotational (FR) domain walls because the FR order, in contrast to ferromagnetism and ferroelectricity, is invariant under both the spatial-inversion and the time-reversal operations and, thus, hardly couple with conventional experimental probes. Here, a FR candidate NiTi⁢O 3 is investigated by ultrasensitive electric quadrupole (EQ) second-harmonic generation rotational anisotropy (SHG RA) to probe the point symmetries of the two degenerate FR domain states, showing their relation by the vertical mirror operations that are broken below the FR critical temperature. We then visualize the real-space FR domains by scanning EQ SHG microscopy, and further, resolve the FR domain walls by revealing a suppressed SHG intensity at the domain walls. By taking local EQ SHG RA measurements, we show the restoration of the mirror symmetry at FR domain walls and prove their unconventional nonpolar nature. In conclusion, our findings not only provide a comprehensive insight into FR domain walls, but also demonstrate a unique and powerful tool for future studies on domain walls of unconventional ferroics both of which pave the way towards future manipulations and applications of FR domain walls.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗