Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

NG-CT Peaker Upgrades with Bottoming Cycle: Preliminary Analysis

The National Energy Technology Laboratory (NETL) has conducted a preliminary analysis exploring a significant opportunity to increase the nation's power grid capacity and reliability. The study focuses on retrofitting under-utilized natural gas combustion turbines (NG-CTs), often called "peaker" plants, with a bottoming cycle to capture waste heat and generate additional electricity. This analysis shows that upgrading these existing assets could add approximately 26,250 MW of new power capacity across the United States. A detailed study of the PJM Interconnection, the nation's largest grid operator, confirmed the benefits of these upgrades. Key findings for the PJM region include: - A median increase in the plants' capacity factor by 17 percentage points. - A projected 36.2% median reduction in the levelized cost of electricity (LCOE) for the upgraded plants, with nearly 88% of them expected to break even. - An average reduction in the regional wholesale price of electricity by approximately 3.0% in the year 2030. - A significant boost to grid reliability, with a 46% reduction in projected Loss of Load Hours (LOLH). These findings suggest that retrofitting peaker plants is a promising and economically viable strategy to enhance grid performance, reduce electricity costs, and meet future demand without the challenges associated with building entirely new facilities.

bottoming cycle↗

Comparative Study of Data-Driven Area Inertia Estimation Approaches on WECC Power Systems

With the increasing integration of inverter-based resources into the power grid, there has been a notable reduction in system inertia, potentially compromising frequency stability. To assess the suitability of existing area inertia estimation techniques for real-world power systems, this paper presents a rigorous comparative analysis of system identification, measurement reconstruction, and electromechanical oscillation-based area inertia estimation methodologies, specifically applied to the large-scale and multi-area WECC 240-bus power system. Comprehensive results show that the system identification-based approach exhibits superior robustness and accuracy relative to its counterparts.

area inertia estimation↗

Nuclear Propulsion through Direct Conversion of Fusion Energy: The Fusion Driven Rocket

The future of manned space exploration and development of space depends critically on the creation of a dramatically more proficient propulsion architecture for in-space transportation. A very persuasive reason for investigating the applicability of nuclear power in rockets is the vast energy density gain of nuclear fuel when compared to chemical combustion energy. Current nuclear fusion efforts have focused on the generation of electric grid power and are wholly inappropriate for space transportation as the application of a reactor based fusion-electric system creates a colossal mass and heat rejection problem for space application.

Propulsion↗

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

SPS overview: Requirements, alternatives, and reference system

Basic requirements for the SPS were established. The SPS is considered to be nondepletable with a large positive energy payback over its useful life, capable of base-load operation with no fundamental constraints on capacity. It is compatible with power grids, economically competitive and environmentally acceptable. It should not make excessive use of critical resources, and should be capable of development with reasonable cost, time, and risk. Several of the power generation options and equipment considered are discussed. The reference set of efficiencies defined to represent goals for each step in the power conversion-transmission-reception chain is also described.

Livingston, L. E.↗

Multilayered Cu-Carbon Nanotube Composites for Advanced Conductors

Improving the efficiency of electrical components is critical in reducing energy consumption for various industrial and residential applications, ranging from rotating machinery to all electric devices and electric vehicle (EV) components to power grid systems. Substituting Cu wires with reduced resistance conductors that incorporate carbon nanotubes (CNTs) into Cu─ultraconductive Cu (UCC) composites─has recently been considered a promising strategy to improve energy efficiency, power density, and/or performance across various applications. Here, in this study, we created stable material formulations [CNT-containing polyvinylpyrrolidone (PVP) in dimethylformamide (DMF) solution] and utilized commercially viable fabrication approaches (electrospinning and magnetron sputtering) that produced high-performance multilayered tape-based UCC composite architectures. Increasing the CNT volume fraction by sequential layering of the structure with additional Cu-CNT layers showed a nearly stepwise improved performance in electrical and mechanical properties. This study also provides valuable insight into the effectiveness of nitrogen doping in modifying the conductivity of the CNT matrix. Fabricated prototypes demonstrated a >10% increase in current carrying capacity and >10% improvement in mechanical strength compared to those obtained on pure Cu. We believe that the properties demonstrated here, combined with the scalable manufacturing pathway of our approach, pave the way in designing future advanced conductors for diverse energy efficient and high-performance electrical systems and applications.

Carbon nanotubes↗

Deliberate Design: Creating Electricity Rates with Purpose

Today’s electricity rates often are legacy designs that do not reflect the dynamics of an evolving power grid or align with current policy objectives. Four steps will assist utilities, regulators, and industry stakeholders in modernizing outdated electricity rate designs. 1. Understand the context for rate design change: The power system is changing at a pace that the industry has not experienced for decades. It is essential to understand the implications of these changes so rates can evolve to remain consistent with changes to the underlying cost profile, customer preferences, and power system requirements. 2. Establish ratemaking objectives: Rates can do more than recover utility costs. They can be a tool for promoting desired outcomes such as improved energy affordability, flexible and efficient electricity consumption, or promoting technology adoption. First, these objectives must be clearly defined and prioritized. 3. Account for tradeoffs when designing new rates: Rate design is the art of balancing tradeoffs. It is essential to understand these tradeoffs when designing new rates, particularly if the rates are being used as a tool for accomplishing policy objectives that extend beyond the basic goal of cost reflectivity. 4. Transition to the new rates with a plan: The move to well-designed rates requires a transition plan. This will ensure that rate design changes do not happen in isolation and are consistent with a long-term, holistic vision. The report, published as an interactive web tool for which the content can be separately downloaded as a standalone document, is intended to allow state energy regulators, utility rates staff, and other industry stakeholders with an interest in rate design to selectively “drill down” on content that is relevant to their interests and situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Feasible Actuator Range Modifier (FARM), a Tool Aiding the Solution of Unit Dispatch Problems for Advanced Energy Systems

Integrated energy systems (IESs) seek to minimize power generating costs in future power grids through the coupling of different energy technologies. To accommodate fluctuations in load demand due to the penetration of renewable energy sources, flexible operation capabilities must be fully exploited, and even power plants that are traditionally considered as base-load units need to be operated according to unconventional paradigms. Thermomechanical loads induced by frequent power adjustments can accelerate the wear and tear. If a unit is flexibly operated without respecting limits on materials, the risk of failures of expensive components will eventually increase, nullifying the additional profits ensured by flexible operation. In addition to the bounds on power variations (explicit constraints),the solution of the unit dispatch problem needs to meet the limits on the variation of key process variables, including temperature, pressure and flow rate (implicit constraints).The FARM (Feasible Actuator Range Modifier) module was developed to enable existing optimization algorithms to identify solutions to the unit dispatch problem that are both economically favorable and technologically sustainable. Thanks to the iterative dispatcher–validator scheme, FARM permits addressing all the imposed constraints without excessively increasing the computational costs. In this work, the algorithms constituting the module are described, and the performance was assessed by solving the unit dispatch problem for an IES composed of three units, i.e., balance of plant, gas turbine, and high-temperature steam electrolysis. Finally, the FARM module provides dedicated tools for visualizing the response of the constrained variables of interest during operational transients and a tool aiding the operator at making decisions. These techniques might represent the first step towards the deployment of an ecological interface design (EID) for IES units.

47 OTHER INSTRUMENTATION↗

Computational Analysis and Optimized Modeling of Geomagnetically Induced Currents in Power Transformers

In this project we aim to better understand the effect of geomagnetically induced currents (GIC) on power transformers. Expanding upon our previous work focused on producing a methodology for accuracy-enhanced computation of GIC signatures (i.e., time-domain current magnitude variation for the event duration) from a combination of physics-based and data-driven computational tools, we propose the use of these GIC signatures as inputs for a physically-detailed and optimized model of the power transformer to investigate how GIC determination and transformer modeling influence the evaluation of GIC effects on the transformer operation, as well as in its interaction with the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proposed Algorithm for Placement and Sizing of Generation and Storage Stations in Urban Environments

The placement of generation and storage stations (GSSs) in distribution grids has been extensively investigated. Most traditional methods are applicable to rural or homogeneous environments and do not account for external restrictions on generation placement in urban or semi-urban environments. In this article, we propose a method for generation placement considering externality constraints. New utility-scale generation in distribution grids potentially occupies footprint and interferes in areas with existing infrastructure with architectural, historical, or touristic value. Urban environments are often regulated by municipal legislation. The placement of utility-scale generation in urban landscapes is economically and physically restricted by such externalities, and existing methods for generation placement in distribution grids based on technical optimization fail to account for this important nuance. The proposed algorithm flexibly adapts to changes in government energy policies and priorities. The selection of the type of generation suitable for the power grid is left to the preference of external high-level stakeholders, such as urban planners, industry development leaders, and energy policymakers. The proposed algorithm is a unique tool for determining the placement and sizing of generation in realistic conditions in distribution grids; it is adaptable to urban externalities and sensitive to stakeholder preferences.

generation and storage station placement↗

Seasonal Reconfiguration of Electrical Distribution Systems to Mitigate the Impact of Electric Vehicle Charging

Power grids face challenges in their infrastructure related to the integration of electric vehicles (EV). In particular, EV charging stations may induce instability in key system parameters such as substantial voltage drops, active power losses, and transformer overload due to high demand during charging periods. This article presents a seasonal reconfiguration strategy based on the differential evolution (DE) algorithm, aimed at enhancing system performance under highly variable and stochastic load profiles, particularly those driven by EV charging. The DEA algorithm is hybridized with the find-union (FU) algorithm to efficiently ensure network radiality throughout the optimization process. The proposed methodology is validated on a hybrid distribution system composed of the IEEE 33-bus network, a modified IEEE 13-bus system, and a specific 13-bus microgrid. Results have demonstrated that seasonal reconfiguration significantly reduces active power losses and mitigates transformer loading during critical demand hours, thereby quantifiably increasing the system’s performance. As an integral component of the proposed approach, an analysis of CO2 emissions associated with energy losses is included, allowing a contextualized assessment of the environmental benefits of seasonal reconfiguration in various geographical areas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tools and Techniques for Measuring and Improving Grid Performance

This viewgraph presentation provides information on NASA's geographically dispersed computing resources, and the various methods by which the disparate technologies are integrated within a nationwide computational grid. Many large-scale science and engineering projects are accomplished through the interaction of people, heterogeneous computing resources, information systems and instruments at different locations. The overall goal is to facilitate the routine interactions of these resources to reduce the time spent in design cycles, particularly for NASA's mission critical projects. The IPG (Information Power Grid) seeks to implement NASA's diverse computing resources in a fashion similar to the way in which electric power is made available.

Biswas, Rupak↗

Regional Analysis for an Economically and Environmentally Viable Transition to Heavy-Duty Vehicles with Alternative Powertrains

The transportation sector is responsible for a significant portion of greenhouse gas emissions. Within the sector, truck freight is responsible for a third of the associated emissions. Alternative powertrains are seen as a viable approach to significantly reduce these emissions. Prior to making a large-scale transition, it is important to consider the following questions: will the power grid support a transition to alternative powertrains?; will the transition truly reduce carbon emissions?; and will the transition impose an unnecessary economic burden on companies within the industry? The answer to these questions, however, can vary by geography, maturity/capacity of the energy distribution network or predicted vehicle load. We focus on the latter two questions, investigating the variation in estimated total cost of ownership and carbon emissions across the United States at the zip code level for both heavy-duty battery electric vehicles and heavy-duty fuel cell electric vehicles. As a benchmark, we compare estimated emissions and costs of alternative powertrain vehicles to that of conventional heavy-duty vehicles powered by diesel internal combustion engines. This work highlights areas with electric grids primed for a transition to alternative powertrain vehicles, such as the Pacific Northwest, and areas that require further infrastructure investment in renewables, such as many of the Mountain states, Missouri, and Florida. Additionally, this work illustrates the current advantages in carbon emissions of battery electric vehicles compared to fuel-cell electric vehicles, while providing insights into required regional investments for narrowing the gap.

Goulet, Nate [ORNL] (ORCID:0000000237314965)↗

Riemannian Optimization Applied to AC Optimal Power Flow

The nonlinear, nonconvex AC optimal power flow problem is of growing importance as the nature of the power grid evolves. This problem can be difficult to solve for interior point methods. However, the advent of optimization algorithms over smooth Riemannian manifolds presents an alternative approach. The nonlinear, nonconvex constraints in the AC power flow problem form an embedded submanifold of Euclidean space. In this paper, the authors explore the performance of Riemannian optimization algorithms for the ACOPF problem where the optimization is performed directly on the AC power flow manifold. This is done by using the Julia programming language and the Julia packages PowerModels.jl and Manopt.jl.

AC optimal power flow↗

Deep Reinforcement Learning Based Control of Wind Turbines for Fast Frequency Response

In order to fulfill vital auxiliary grid services, such as load regulation, spin and non-spin reserve provision, and frequency support during emergencies, there is often a requirement for certain wind farms to operate in de-loaded modes. Leveraging the swift response capabilities of wind farms, this study demonstrates that reserving power in de-loaded modes can significantly enhance power grid stability and reliability during system contingencies. Controlling wind farms optimally for frequency support is intricate due to the nonlinearity of models and controllers and the complexity of wind farm interactions with power systems. Here, to address this challenge, this paper introduces a novel approach that integrates wind turbines into reinforcement learning-based solutions for frequency response. This innovative methodology utilizes the state-of-the-art reinforcement learning algorithm known as the surrogate-gradient-based evolutionary strategy. The proposed learning-based algorithm provides continuous control of wind farm output to rapidly stabilize system frequency and prevent unnecessary trips of under-frequency load shedding relays. To facilitate efficient training, parallel computing techniques are employed. The proposed methodology is evaluated on a modified IEEE-39 bus system, and simulation results reveal its efficacy in reliably supporting power system frequency and preventing the need for unnecessary load shedding.

Gao, Wei [Argonne National Laboratory (ANL), Argon↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

A 15 kWe (nominal) solar thermal-electric power conversion concept definition study: Steam Rankin reciprocator system

A conceptual design of a 3600 rpm reciprocation expander was developed for maximum thermal input power of 80 kW. The conceptual design covered two engine configurations; a single cylinder design for simple cycle operation and a two cylinder design for reheat cycle operation. The reheat expander contains a high pressure cylinder and a low pressure cylinder with steam being reheated to the initial inlet temperature after expansion in the high pressure cylinder. Power generation is accomplished with a three-phase induction motor coupled directly to the expander and connected electrically to the public utility power grid. The expander, generator, water pump and control system weigh 297 kg and are dish mounted. The steam condenser, water tank and accessory pumps are ground based. Maximum heat engine efficiency is 33 percent: maximum power conversion efficiency is 30 percent. Total cost is $3,307 or $138 per kW of maximum output power.

Wingenback, W.↗