Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

On Final Results From the Muon $g\mathrm{-}2$ Experiment at Fermilab

The Muon g-2 Experiment at Fermilab has measured the muon anomalous magnetic moment, a_mu, with unprecedented precision, leveraging a dataset from Runs 1 6 that is 21 times larger than its Brookhaven predecessor. This talk will present the experiment s final result, which serves as a benchmark for testing the Standard Model with high precision. The measurement was performed in a storage ring with a highly uniform magnetic field, where precise beam dynamics understanding is vital to determine the muon anomalous precession frequency. Key to this effort were advanced simulation tools including COSY INFINITY, precise fringe field modeling, and calculations of beam dynamics characteristics like tunes and chromaticity. We will conclude by exploring how the experiment's findings reshape our understanding of particle physics.

Valetov, Eremey [Michigan State U.]↗

Analog Systems for Edge Optimization

Over the past decade, analog computing has the subject of substantial research interest providing a path toward improved computational efficiency in the post-Dennard era. Analog matrix vector multiplication (MVM) accelerators provide a popular approach given the ubiquity of MVM operations in numerous applications. However, historically analog computing systems can struggle with applications requiring high precision due to the inherent susceptibility of these systems to analog non-idealities. Therefore, prior work on analog systems has focused either on applications known to be tolerant of limited precision (e.g., neural network inference), or using expensive techniques to emulate high-precision using many analog MVM operations. In this work, we propose an alternative approach. Motivated by recent advances in inexact nonlinear solvers and optimizers, we explore the potential of co-designing optimization algorithms which can take full advantage of the fundamentally inexact analog MVM operations. To enable these co-designed algorithms we also develop a general mathematical theory of the precision and energy efficiency of analog operations, and a new system architecture for tightly-coupled analog and digital computation. Finally, we examine the applicability of analog computing to a wider class of symmetric positive definite systems and find potential in using analog operations as a sparse approximate inverse preconditioner. With these core innovations, this project provides a path toward effectively implementing optimization algorithms on power-constrained autonomous and semi-autonomous systems.

97 MATHEMATICS AND COMPUTING↗

Dynamic Modeling, Trajectory Optimization, and Linear Control of Cable-Driven Parallel Robots for Automated Panelized Building Retrofits

The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.

CDPR↗

The NuMI Flux Prediction at ICARUS

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment seeking to probe fundamental symmetries within the structure of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix, and perform precision measurements its parameters including the neutrino mass ordering via the sign of $\Delta m^2_{31}$, and the charge-parity violating phase, $\delta_{CP}$. To make these measurements with high precision, DUNE will require external $\nu$-Ar scattering cross section data as a crucial input to the oscillation fit. Imaging Cosmic And Rare Underground Signals (ICARUS) is a 476 t liquid argon neutrino detector located at Fermi National Accelerator Laboratory (FNAL) where it is serving as the far detector for the Short-Baseline Neutrino (SBN) program along the Booster Neutrino Beam (BNB) axis. ICARUS additionally lies 795 m downstream and 100.1 mrad off-axis of the Neutrinos at the Main Injector (NuMI) neutrino beam. From this position, ICARUS is exposed to a large flux of NuMI (anti-)electron and (anti-)muon neutrinos, and poses a unique opportunity to provide high-statistics measurements of quasi-elastic and single pion-production cross sections for four neutrino flavors ($\nu_{\mu}$, $\nu_{e}$, $\bar{\nu}_{\mu}$, $\bar{\nu}_{e}$). This dissertation is centered around accurately characterizing the models and estimating their precision for use in making these measurements. This includes identifying major sources of uncertainty in the models such that they can be properly propagated to the cross section measurements. Specifically, this work focused on the model of the NuMI beamline and its impact on the neutrino fluxes, but also delved into the detector response model and its impact on reconstructed observables in the detector. Significant efforts were made to improve the characterization to enhance precision and thus reduce the level of propagated uncertainty. In particular, the NuMI flux was determined to be composed of 57% $\nu_{\mu}$, 38% $\bar{\nu}_{\mu}$, 3% $\nu_{e}$, and 2% $\bar{\nu}_{e}$ while the horns are operating in the positive-particle focusing configuration. The total uncertainty on the $\nu_{\mu} + \bar{\nu}_{\mu}$ ($\nu_{e} + \bar{\nu}_{e}$) flux while operating in the forward horn operating mode was determined to be 10.84% (9.04%). Compared to the on-axis flux, mesons that eventually decay to neutrinos more frequently reinteract within the NuMI structure, resulting in elevated uncertainty as these processes are not well-constrained by existing hadron interaction cross section measurements. Covariance matrices were calculated to propagate the flux uncertainty characterization to NuMI analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

“Unification” of BSM searches and SM measurements: the case of lepton+E T and m W

We develop the idea that the unprecedented precision in Standard Model (SM) measurements, with further improvement at the HL-LHC, enables new searches for physics Beyond the Standard Model (BSM). As an illustration, we demonstrate that the measured kinematic distributions of the ℓ + E T final state not only determine the mass of the W boson, but are also sensitive to light new physics. Such a search for new physics thus requires a simultaneous fit to the BSM and SM parameters, “unifying” searches and measurements at the LHC and Tevatron. In this paper, we complete the program initiated in our earlier work [1]. In particular, we analyze (i) novel decay modes of the W boson with a neutrinophilic invisible scalar or with a heavy neutrino; (ii) modified production of W bosons, namely, associated with a hadrophilic invisible Z′ gauge boson; and (iii) scenarios without an on-shell W boson, such as slepton-sneutrino production in the Minimal Supersymmetric Standard Model (MSSM). Here, we complement our previous MSSM analysis in [1] by considering a different kinematic region. Our results highlight that new physics can still be directly discovered at the LHC, including light new physics, via SM precision measurements. Furthermore, we illustrate that such BSM signals are subtle, yet potentially large enough to affect the precision measurements of SM parameters themselves, such as the W boson mass.

Electroweak Precision Physics↗

An effective field theory for muon conversion and muon decay-in-orbit

Muon conversion is one of the best probes of charged lepton flavor violation. The experimental limit is soon expected to improve by four orders of magnitude, thus calling for precise predictions of the shape of the signal spectrum. Equally important are precise predictions for muon decay-in-orbit, the main background for muon conversion. While the calculation of electromagnetic corrections to the two processes above the nuclear scale does not involve significant challenges, it becomes substantially more complex below that scale due to multiple scales, bound-state effects and experimental setup. Here, we present a systematic framework that addresses these challenges by resorting to a series of effective field theories. Combining Heavy Quark Effective Theory (HQET), Non-Relativistic QED (NRQED), potential NRQED, Soft-Collinear Effective Theory I and II, and boosted HQET, we derive a factorization theorem and present the renormalization group equations. Our framework allows for the proper calculation of precise predictions for the rates of the two processes, with crucial implications for the upcoming muon conversion searches. We also provide the most accurate prediction of the signal shape for those searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EFT approach to the endpoint of muon decay-in-orbit

As upcoming experiments aim to probe muon conversion with unprecedented precision, equally precise theoretical predictions are crucial to maximize discovery potential. This applies not only to the new physics signal, muon-electron conversion, but also to its only irreducible background, muon decay-in-orbit (DIO) near the endpoint. Accurate computation of higher-order corrections in bound states is a long-standing challenge due to the difficulty of systematically organizing contributions. In previous work, we developed an Effective Field Theory framework to address this issue and applied it to muon conversion. Here, we extend this approach to the DIO endpoint, a more complex problem due to the presence of a neutrino-antineutrino pair in the final state. We present the most precise prediction to date of the background spectrum relevant for future muon conversion searches, achieving next-to-leading logarithmic prime accuracy for QED corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Purity Quantum Emission from an Au 24 (S-CH 2 Ph- t Bu) 20 Nanocluster at Room Temperature

Atomically precise gold nanoclusters have garnered significant attention for their diverse applications, ranging from biological labeling to optoelectronics. Their potential in optical quantum computing, which calls for ideal single-photon sources, has recently become a key area of interest. In the current work, we use photon antibunching experiments to explore the single-photon emission efficiency of atomically precise Au 24 nanoclusters protected by 4-tert-butylbenzyl mercaptan ligands (Au 24 (TBBM) 20 ). This cluster exhibits quantum emission with good photostability and without any observable blinking or spectral drift at room temperature under an inert gas atmosphere, with antibunching dips (g 2 (0)) as low as 0.07 in the solid state or, equivalently, a single-photon purity of 93% under time-gated conditions. Transient absorption and time-gated antibunching studies reveal that the short emission lifetime of this cluster and its high photoluminescence quantum yield in the solid state play critical roles in enhancing the emitted single-photon purity. This research advances the understanding of single-emitter behavior in atomically precise gold nanoclusters, contributing to the development of stable quantum emitters that are essential for quantum computing and cryptography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Stopping Ages for Colorectal Cancer Screening

Importance Prior studies have shown that the benefits, harms, and costs of colorectal cancer (CRC) screening at older ages are associated with a patient’s sex, health, and screening history. However, these studies were hypothetical exercises and not directly informed by data on CRC risk. Objective To identify the optimal stopping ages for CRC screening by sex, comorbidity, and screening history from a cost-effectiveness perspective. Design, Setting, and Participants This economic evaluation first validated the MISCAN-Colon (Microsimulation Screening Analysis–Colon) model against community-based CRC incidence and mortality rates for 2 subcohorts of the PRECISE (Optimizing Colorectal Cancer Screening Precision and Outcomes in Community-Based Populations) cohort. Subsequently, different CRC screening scenarios were simulated in older individuals. Cohorts of US adults aged 76 to 90 years varied by sex and comorbidity status (none, low, moderate, or severe). Statistical and sensitivity analyses were performed from March 2023 to May 2024. Exposures CRC screening histories including fecal immunochemical test (FIT) or colonoscopy, such as a negative colonoscopy result from 10, 15, 20, 25, or 30 years before the index age; 1 to 5 negative FIT results within 5 years of the index age, with different patterns of recency; or a combination of negative colonoscopy and negative FIT results. Main Outcomes and Measures The main outcomes included estimated lifetime clinical outcomes, incremental costs, and quality-adjusted life-years gained (QALYG) associated with 1 additional FIT or colonoscopy. Optimal stopping age for screening, defined as the oldest age for which the incremental cost-effectiveness ratio was still below the willingness-to-pay threshold of $\$$100 000 per QALYG, was evaluated. Results The first of the 2 PRECISE subcohorts used in validating the simulation model included 25 974 adults (15 060 females [58.0%]; 54.7% aged 76 to 80 years) with a negative colonoscopy result 10 years before the index date. The second subcohort consisted of 118 269 adults (67 058 females [56.7%]; 90.5% aged 76 to 80 years) with a negative FIT result 1 year before the index date. Older age, male sex, higher comorbidity levels, and recent CRC screenings were associated with reduced incremental benefit and cost-effectiveness of additional screening. For the reference cohort of 76-year-old females without comorbidities and a negative colonoscopy result 10 years before the index age, 1 additional colonoscopy cost $\$$38 226 per QALYG. For cohorts with otherwise equivalent characteristics, associated costs increased to $\$$1 689 945 per QALYG for females at age 90 years without comorbidities and a negative colonoscopy results 10 years before the index age, $\$$51 604 per QALYG for males at age 76 years without comorbidities and a negative colonoscopy result 10 years before the index age, and $\$$108 480 per QALYG for females at age 76 years with severe comorbidities and a negative colonoscopy result 10 years before the index age and decreased to $\$$16 870 per QALYG for females without comorbidities and a negative colonoscopy result 30 years before the index age. The optimal stopping ages across different cohorts ranged from younger than 76 to 86 years for colonoscopy and younger than 76 to 88 years for FIT. Conclusions and Relevance In this economic evaluation, age, sex, screening history, comorbidity, and future screening modality were associated with the clinical outcomes, cost-effectiveness, and optimal stopping age for CRC screening. These results can inform guideline development and patient-directed informed decision-making.

Harlass, Matthias [Erasmus Erasmus University Medi↗

Defect‐Free Nanowelding of Bilayer SnSe Nanoplates

Nanowelding is a bottom‐up technique to create custom‐designed nanostructures and devices beyond the precision of lithographic methods. Here, a new technique is reported based on anisotropic lubricity at the van der Waals interface between monolayer and bilayer SnSe nanoplates and a graphene substrate to achieve precise control of the crystal orientation and the interface during the welding process. As‐grown SnSe monolayer and bilayer nanoplates are commensurate with graphene's armchair direction but lack commensuration along graphene's zigzag direction, resulting in a reduced friction along that direction and a rail‐like, 1D movement that permits joining nanoplates with high precision. This way, molecular beam epitaxially grown SnSe nanoplates of lateral sizes 30–100 nm are manipulated by the tip of a scanning tunneling microscope at room temperature. In situ annealing is applied afterward to weld contacting nanoplates without atomic defects at the interface. This technique can be generalized to any van der Waals interfaces with anisotropic lubricity and is highly promising for the construction of complex quantum devices, such as field effect transistors, quantum interference devices, lateral tunneling junctions, and solid‐state qubits.

2D ferroelectrics↗

Nanometer Resolution Structure‐Emission Correlation of Individual Quantum Emitters via Enhanced Cathodoluminescence in Twisted Hexagonal Boron Nitride

Understanding the atomic structure of quantum emitters, often originating from point defects or impuritie, is essential for designing and optimizing materials for quantum technologies such as quantum computing, communication, and sensing. Despite the availability of atomic-resolution scanning transmission electron microscopy and nanoscale cathodoluminescence microscopy, experimentally determining the atomic structure of individual emitters is challenging due to the conflicting needs for thick samples to generate strong cathodoluminescence signals and thin samples for structural analysis. To overcome this challenge, significantly enhanced cathodoluminescence at twisted interfaces is leveraged to achieve sub-nanometer localization precision for the first time in mapping individual quantum emitters in carbon-implanted hexagonal boron nitride. This unprecedent spatial sensitivity, together with correlative electron energy loss spectroscopy quantitative scanning transmission electron microscopy imaging, and first principles density functional theory calculations, enables the identification of the atomic structure of the 440 nm blue emitter in hexagonal boron nitride as a substituted vertical carbon dimer. Building on the atomic structure insights, nanoscale spatially precise creation of blue emitters is demonstrated by electron beam irradiation of carbon-coated hexagonal boron nitride. This advancement in correlating atomic structures with optical properties lays the foundation for a deeper understanding and precise engineering of quantum emitters, significantly advancing the development of cutting-edge quantum information technologies.

2D material↗

Utilization of Data Augmentation Techniques in Automated Inspection Systems for Defect Detection in Metals With Limited Data

Accurate identification of defects on metal surfaces is of great interest to many industry sectors, such as the automotive and aerospace industries. In contrast to conventional manual inspection techniques, recent automated inspection systems employ deep learning models trained to detect defects rapidly and precisely. The development of these models often requires a substantial image dataset to acquire adequate knowledge of defect features and enhance their predictive accuracy. When data is limited, augmentation techniques are often used to improve the precision and accuracy of defect detection systems. This study examined the prediction performance of two object detection models, namely Faster Region‐based Convolutional Neural Network (Faster R‐CNN) and You Only Look Once version 8 (YOLOv8), to identify dent defects in limited images of cast iron cylinder head surfaces. The original image set contains 46 images with 563 dents. To overcome limited data availability, common image augmentation techniques along with a copy‐paste method were applied. Results show that standard augmentation improved YOLOv8 accuracy by 8.00% and average precision (AP) by 3.00%. On the other hand, the copy‐paste technique achieved a 20.00% increase in accuracy and a 1% increase in AP with just 200 synthetic dents. Furthermore, these results provide support for using the copy‐paste augmentation strategy to enhance defect detection performance, with a limited dataset, contributing to more accurate defect identification in remanufacturing processes.

36 MATERIALS SCIENCE↗

Comparison of removal and spatial mark‐resight models for estimating wild pig density

Density estimation is critical to effectively manage invasive species and elucidate areas of highest concern. For wild pigs (Sus scrofa), the ability to estimate density is complicated because of their variable home range sizes and social structure. Common methods for estimating density (e.g., mark-recapture) may be unsuitable in management applications because additional data needs to be collected before and after management. Removal models offer a suitable alternative to estimate density changes following management and can be applied broadly across areas where management of wild pigs is ongoing. We collected wild pig removal and camera trap data from 25 private properties ranging in size from approximately 0.5 km 2 to 95 km 2 across 3 ecoregions in South Carolina, USA, from 2020–2023. We compared factors affecting consistency and precision of property-level density estimates between removal and spatial mark-resight (SMR) models. In general, excluding 1 large outlier, density estimates from removal models were between 0.60 and 15.85 wild pigs/km 2 (median = 5.34) with a median coefficient of variation (CV) of 0.76 and 95% confidence intervals for the CV between 0.70 and 0.94. Similarly, excluding 1 large outlier, density estimates from SMR were between 0.22 and 30.97 wild pigs/km 2 (median = 5.48) with a median CV of 0.39 and 95% confidence intervals for the CV between 0.38 and 1.20. We found the precision of removal models was affected primarily by the number of wild pigs dispatched in the removal period (3 months) and the ecoregion in which they were removed. None of the covariates, including the number of recaptures (a corresponding measure of sample size), influenced precision of the SMR models, although recaptures did influence the density estimates. At the individual property level, density estimates from our 2 estimators were dissimilar from each other in approximately 80% of instances, although none of the covariates we examined influenced dissimilarity. Our results provide unique insight into how sample size affects density estimates using 2 common methods and into novel SMR models that incorporate both marked and unmarked detections. In addition, the density estimates in this study can be used as a reference for wild pig densities in common land cover types throughout the southeastern United States.

60 APPLIED LIFE SCIENCES↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{cos θ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for exploring non-standard neutrino properties with argon-based CEvNS experiments

Coherent elastic neutrino-nucleus scattering (CEvNS) provides a powerful frame-work for testing the Standard Model (SM) and searching for new physics at low energies. In this work, we examine the prospects for argon-based CEvNS experiments at stopped-pion sources to perform precision measurements of weak interactions and probe non-standard neutrino properties. Our study focused on the CENNS-10 and CENNS-750 detectors at the Spallation Neutron Source at Oak Ridge National Laboratory, the Coherent Captain Mills (CCM) detector at Los Alamos National Laboratory, and the proposed PIP2-BD detector at Fermilab’s Facility for Dark Matter Discovery (F2D2). Using realistic neutrino fluxes and detector configurations corresponding to these facilities, we evaluate event rates and sensitivities to a range of observables. Within the SM, argon-based CEvNS detectors enable precision tests of electroweak parameters, including the weak mixing angle, at momentum transfers well below the electroweak scale. We also investigate the sensitivity of these experiments to neutrino electromagnetic properties, such as the magnetic moment and effective charge radius, as well as to possible non-standard neutrino interactions with quarks. Together, these studies highlight the potential of argon-based CEvNS experiments as a clean and versatile platform for precision exploration of non-standard neutrino properties.

Carey, Sam [Wayne State U.] (ORCID:000900029607531↗

Triple oxygen and hydrogen stable isotope composition of water in Murchison carbonaceous chondrite accessed by thermogravimetry-enabled laser spectroscopy

For this work, we have developed the capability to measure 17 O/ 16 O in H 2 O and OH - of hydrous minerals by a technique using thermogravimetric analysis coupled with isotope ratio infrared spectroscopy (TGA-IRIS) on a suite of liquid water standards, terrestrial mineral standards, multi-mineral synthetic mixtures of terrestrial samples, and Murchison carbonaceous chondrite. This 17 O/ 16 O analytical capability is combined with the previously developed TGA-IRIS capability of 18 O/ 16 O, which enables us to calculate Δ `17 O values. Additionally, we have made 2 H/ 1 H measurements by TGA-IRIS on the suite of materials. Analyses of 328 standard water samples sealed into silver tubes (0.25 μL, 174 VSMOW and 154 GISP) analyzed over the course of three years yielded δ 18 O values by TGA-IRIS with precision of ±0.30 ‰, δ 17 O of ±0.24 ‰, Δ `17 O of ±0.126 ‰, and δ 2 H ± 7.5 ‰ (± 1 Std. Dev.). TGA-IRIS analyses of a suite of hydrous minerals (oxy-hydroxide, mica, serpentines, sulfide, phyllosillicates) yields similar precision. TGA-IRIS analyses of the CM2 carbonaceous chondrite Murchison resulted in δ 18 O, δ 17 O, Δ `17 O, and δ 2 H values of the H 2 O and/or OH - from its hydrous minerals. Δ `17 O values of Murchison H 2 O range from 1.034 ‰ at 350 °C, to -0.368 ‰ at 650 °C, to -1.75 ‰ at 850 °C. TGA-IRIS can generate Δ `17 O values of H 2 O and/or OH - in hydrous materials that are well within the precision needed for the analysis of meteoritic samples, as well as samples returned from asteroids, such as Ryugu and Bennu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementing nonlinear optics from Off-Energy closed orbit at NSLS-II

To characterize the second-order (chromatic sextupole) magnet lattice with high precision, we implemented nonlinear optics from off-energy closed orbit (NOECO) tool based on the linear optics from closed orbit modulation (LOCOM) method, named LOCOM-NOECO. The preliminary numerical study indicates that 1–2% precision can be achieved for the calibration of chromatic sextupoles. Further, this accuracy could potentially help in resolving some long-standing challenges of NSLS-II (e.g., the discrepancy between the designed and measured dynamic apertures) if such high precision can be fulfilled. As an independent crosscheck, we also implemented NOECO based on the independent component analysis (ICA) method using turn-by-turn (TBT) BPM data, named ICA-NOECO. Both ICA-NOECO and LOCOM-NOECO have been successfully applied to identify the pre-dialed random errors of a chromatic sextupole family including five power supplies, and achieved the root mean square (RMS) residual error of 1% and peak error less than 2%. Moreover, to mitigate the chromatic sextupole error effect, we applied the correction and achieved significant improvements in the injection efficiency as well as the dynamic apertures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗