At least 325 records · Page 18

High-R Walls for New Construction Structural Performance: Integrated Rim Header Testing

Two prominent approaches within the Building America Program to construct higher R-value walls have included use of larger dimension framing and exterior rigid foam insulation. These approaches have been met with some success; however for many production builders, where the cost of changing framing systems is expensive, the changes have been slow to be realized. In addition, recent building code changes have raised some performance issues for exterior sheathing and raised heel trusses, for example, that indicates a need for continued performance testing for wall systems. The testing methods presented in this report evaluate structural rim header designs over openings up to 6 ft wide and applicable to one- and two-story homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygric Redistribution in Insulated Assemblies. Retrofitting Residential Envelopes Without Creating Moisture Issues

The Building America program has recognized that most of the current housing stock is in need of energy related retrofits. One of the best ways of reducing the space conditioning energy consumption is to improve the thermal performance of the enclosure by adding exterior board foam insulation. This report quantifies the amount of water that can become trapped in the drainage cavity of typical wall systems, and measures the effect of water trapped in the drainage cavity on the moisture content of the sheathing. This study also attempts to explain the discrepancy between hygrothermal simulations and field performance of low permeance, low R-value exterior insulation (e.g. ¾-in. foil faced polyisocyanurate) in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates

The Consortium for Advanced Residential Buildings (CARB) monitored three houses in Jacksonville, FL, to investigate the effectiveness of encapsulated and encapsulated/buried ducts in reducing thermal losses and gains from ductwork in unconditioned attics. Burying ductwork beneath loose-fill insulation has been identified as an effective method of reducing thermal losses and gains from ductwork in dry climates, but it is not applicable in humid climates where condensation may occur on the outside of the duct jacket. By encapsulating the ductwork in closed cell polyurethane foam (ccSPF) before burial beneath loose-fill mineral fiber insulation, the condensation potential may be reduced while increasing the R-value of the ductwork.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Foundation Insulation Strategies for the 2012 International Energy Conservation Code in Cold Climate New Home Construction

While the International Energy Conservation Code 2012 (IECC 2012) has been adopted at a national level, only two cold climate states have adopted it as their new home energy code. Understanding the resistance to adoption is important in assisting more states accept the code and engage deep energy strategies nationwide. This three-part assessment by the NorthernSTAR Building America Partnership was focused on foundation insulation R-values for cold climates and the design, construction, and performance implications. In Part 1 a literature review and attendance at stakeholder meetings held in Minnesota were used to assess general stakeholder interest and concerns regarding proposed code changes. Part 2 includes drawings of robust foundation insulation systems that were presented at one Minnesota stakeholder meeting to address critical issues and concerns for adopting best practice strategies. In Part 3 a sampling of builders participated in a telephone interview to gain baseline knowledge on insulation systems used to meet the current energy code and how the same builders propose to meet the new proposed code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expert Meeting Report: Cladding Attachment Over Exterior Insulation

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. The location of the insulation to the exterior of the structure has many direct benefits including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on thestructure, as well as other commonly associated improvements such as increased air tightness and improved water management (Hutcheon 1964, Lstiburek 2007). The intent of the meeting was to review the current state of industry knowledge regarding cladding attachment over exterior insulation with a specific focus on: 1. Gravity load resistance, 2. Wind load resistance. The presentations explorethese topics from an engineering design, laboratory testing, field monitoring, as well as practical construction perspective. By bringing various groups together (who have been conduction research or have experience in this area), a more holistic review of the design limits and current code language proposals can be completed and additional gaps identified. The results of which will help informdesign standards and criteria.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiochemistry and the Study of Fission

These are slides from a lecture given at UC Berkeley. Radiochemistry has been used to study fission since its discovery. Radiochemical methods are used to determine cumulative mass yields. These measurements have led to the two-mode fission hypothesis to model the neutron energy dependence of fission product yields. Fission product yields can be used for the nuclear forensics of nuclear explosions. The mass yield curve depends on both the fuel and the neutron spectrum of a device. Recent studies have shown that the nuclear structure of the compound nucleus can affect the mass yield distribution. The following topics are covered: In the beginning: the discovery of fission; forensics using fission products: what can be learned from fission products, definitions of R-values and Q-values, fission bases, K-factors and fission chambers, limitations; the neutron energy dependence of the mass yield distribution (the two mode fission hypothesis); the influence of nuclear structure on the mass yield distribution. In summary: Radiochemistry has been used to study fission since its discovery. Radiochemical measurement of fission product yields have provided the highest precision data for developing fission models and for nuclear forensics. The two-mode fission hypothesis provides a description of the neutron energy dependence of the mass yield curve. However, data is still rather sparse and more work is needed near second and third chance fission. Radiochemical measurements have provided evidence for the importance of nuclear states in the compound nucleus in predicting the mass yield curve in the resonance region.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of SNL/MSU/DOE Fatigue Database Trends for Wind Turbine Blade Materials 2010-2015.

Wind turbine blades are designed to several major structural conditions, including tip deflection, strength and b uckling during severe loading, as well as very high numbers of fatigue cycles and various service environments. The MSU Database Program has, since 1989, addressed the broad range of properties needed for current and potential blade materials through stati c and fatigue testing and test development in cooperation with Sandia National Laboratories and wind industry and supplier partners. This report is the latest in a series, giving test results and analysis for the period 2010 - 2015. Program data are compiled in a public database [1] and other reports and publications given in the cited references. The report begins with an executive summary and introductory material including background discussion of previous related studies. Section 3 describes experimental methods including processing, test methods, instrumentation and test development. Section 4 provides static tension, compression and shear stress - strain properties in three directions using coupons sectioned from a thick infused unidirectional glass/epoxy laminate. The nonlinear, shear dominated static properties were characterized with loading - u nloading - reloading (LUR) tests in tension and compression to increasing load levels, for +-45O laminates. Section 5 explores the origins of tensile fatigue sensitivity in glass fiber dominated laminates with variations in fabric architecture including speci ally prepared fabrics and aligned strand laminates. Several types of resins are considered, with variations in resin toughness and bonding to fibers, as well as cure cycle variations for an epoxy. Conclusions are drawn as to the limits of tensile fatigue r esistance and the effects of resin type and fabric architecture, including the behavior of a commercial aligned glass strand product. Interactions between cyclic fatigue response and creep are addressed for off - axis (+-45O) glass/epoxy laminates in Sectio n 6. The nonlinear fatigue and creep stress - strain and cumulative strain response are characterized in tension and compression as a function of stress level, cycles and cumulative time, using square and sinewave loading over a broad range of frequency. The results are analyzed in terms of the cycles and cumulative time under load. A cumulative strain failure criterion is established, and used to construct shear and tension constant life diagrams (CLD's) with data for nine R - values. The effects of a more duc tile urethne resin are also explored. A previous study of thick adhesives testing is extended to mixed mode fracture mechanics testing in Section 7. Mechanisms of static and fatigue crack extension near the laminate adherend interface are reported in deta il. Data are presented for mixed mode adhesive fracture, compared to mixed mode fracture in ply delamination. Fatigue crack growth exponents are also developed for a mixed mode cracked lap shear coupon. The data for fatigue trends and relative failure stra ins and exponents are compared for various blade component materials in Section 8. The effects of temperature and seawater saturation are considered for selected materials of interest for wind and hydrokinetic turbine blades in Section 9. Section 10 gives detailed conclusions for each section. A cknowledgements The research presented in this report was carried out under Sandia National Laboratories purchase orders 1325028 an d 1543945 between 2010 and 2015, with support from the DOE Wind and Water Technologies Office . In addition to the authors listed, significant contributions were made by Patrick Flaherty, Pancastya Agastra, Michael Schuster, and Michael Voth. Industry m aterials suppliers include Vectorply, Saertex, OCV, AGY, Bayer, Ashland, 3M and Nextel. Industry suppliers with significant contributions to the study were Hexion, PPG, Reichhold, Gurit and NEPTCO. Intentionally Left Blank

17 WIND ENERGY↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

First ARM Mobile Facility (AMF1) Aerosol Observing System (AOS01) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Mobile Aerosol Observing System – Aerosols (MAOS-A), designated AOS01, entered service in March of 2012 at the Los Alamos National Laboratory for the Pajarito Aerosol Coupling to Ecosystems (PACE) field campaign. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floor are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Second ARM Mobile Facility (AMF2) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s second mobile facility (AMF2) Aerosol Observing System, designated AOS02, entered service in October of 2010 at Steamboat Springs, Colorado for the Storm Peak Laboratory Cloud Property Validation Experiment (StormVEx). The Aerosol Observing S ystem is meant to be a standalone, autonomous, aerosol sampling system. It requires only power, 208 or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Third ARM Mobile Facility (AMF3) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy ARM user facility’s AMF3 AOS, designated AOS03, entered service in August of 2016 at the ARM Mobile Facility at Oliktok Point, Alaska. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Eastern North Atlantic (ENA) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy ARM user facility’s ENA AOS, designated AOS06, entered service in October of 2013 at the ARM Facility on Graciosa Island, Azores. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Fabrication and Characterization of Plutonium Targets for Irradiation in the Flattop Critical Assembly

In FY16, Pu targets were fabricated in support of the Nuclear Physics: Cumulative Fission Product Yields (Fission R-values) task of the F2016 venture project; these targets are suitable for irradiation in the Flattop critical assembly at the Nevada National Security Site (NNSS). This report documents an overview of the target design, preparation of the Pu metal materials by removing the oxide layer and appropriate sizing for the target holders, target fabrication including filling an inner aluminum cup with the Pu material and the sealing of an outer stainless steel capsule, target assay using gamma spectroscopy, and the He leak testing of the final targets. Four targets were fabricated with two containing 99% 239 Pu metal and two containing 93% 239 Pu metal. Additional samples of each material were set aside for mass spectrometric analysis at PNNL and Los Alamos National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the Thermal and Moisture Performance of Insulating Shades

Heat transfer through windows accounts for a significant percentage of a building’s energy use and adds substantially to the peak heating and cooling loads of a home. Over the past 20 years, residential window attachment retrofit technologies have been developed that significantly increase the number of options available to home builders, homeowners, and utilities when considering upgrades of overall window performance. Within the interior window attachments category, honeycomb cellular shades typically have the highest R-values because of their layered or concentric designs. During the winter when the window is fully covered, however, the added insulation reduces the amount of warm indoor air that reaches the window surface, thereby lowering the temperature of the window glass and frame and increasing the potential for condensation to collect on the interior surface of the window. The degree to which this potential is realized depends on the indoor and outdoor conditions as well as the overall thermal resistance of the window and the shades. To examine the condensation buildup potential on the interior surface of the window and the conditions under which this occurs, this report describes experimental research conducted by Pacific Northwest National Laboratory in collaboration with Hunter Douglas, using a a controlled environmental test chamber at the Hunter Douglas facility in Broomfield, Colorado. The results will be used to inform the Attachments Energy Rating Council, which provides energy performance information on all rated window attachments products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable and Cost-Effective Roll-To-Roll Additive Manufacturing of Highly Durable and Thermal Insulating Silica-Carbon Aerogel (Final Report)

The research objective of this project is to demonstrate low cost silica aerogel insulation materials with high R-value and low installed price of R7.5/inch, and $0.94/ft2-inch, respectively, which can meet the cost and performance targets of the Department of Energy’s 2030 Building Technology Office Emerging Technologies program. The main tasks of this project include the following three topics: a) Low-cost silica gel precursor: Repeat silica sol gel chemical approach which is reproducible and scalable. Also explore suitability of water-glass on silica aerogel system to further control cost efficiency. In addition, our aim is to synthesize hollow silica using low-cost precursors. Sodium silicate (water glass) was chosen as our silica source because of its availability and low price compared to the other precursors; b) In situ ambient pressure-drying (APD) and surface modification: confirm and improve silica aerogel under cost-effective continuous ambient pressure-drying and investigate silica aerogel performance under time and temperature dependence; c) Roll-to-Roll (R2R) manufacturing with the targeted structure, thermal and mechanical characteristics: evaluate 3D printing with silica aerogel precursor to modify aerogel formation.

36 MATERIALS SCIENCE↗

Validation Study of Experimental Insulating and Air-Sealing Technology for Enclosed Roof Cavities

Validation Study of Experimental Insulating and Air-Sealing Technology for Enclosed Roof Cavities, explores a new minimally invasive system known as Pinhole Insulation ® for retroft insulation of cathedral ceilings, flat roofs, dormer roofs, and other enclosed roof cavities. It also explores the validation of the associated equipment, software, and materials used in this application. The Pinhole Insulation process essentially consists of drilling a ¼” hole in the ceiling surface and then injecting closed cell polyurethane foam such that the foam is deposited on the interior surface of the exterior roof sheathing. In a typical cathedral ceiling with R19 batts, the R value will be improved by at least 60% and the cavity will become completely air sealed. The system is quick, minimally invasive and at least an order of magnitude less expensive than alternatives such as removing the ceiling surface and spraying closed cell foam.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗