Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIOACTIVE SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of online pulse-finding algorithms for the Mu2e Stopping Target Monitor and an evaluation of the signal to background ratio for the Mu2e stopped-muon rate determination

This thesis presents a determination of the acceptance of the Mu2e Stopping Target Monitor (STM) detector for both signal and background events. The rate of X-rays of a specific energy in the STM is used to determine the rate of stopped muons in the aluminium stopping target, which is used as the normalisation for all Mu2e measurements, particularly the branching ratio for a charged lepton flavour violating (cLFV) process. The acceptance for the 347\,keV $2p-1s$ aluminium signal X-ray is determined to be $(8.03 \pm 0.05) \times 10^{-10}$\,cm$^{-2}$ and the acceptance for the background photons (at 347\,keV) to be $(3.19 \pm 0.21) \times 10^{-8}$\,cm$^{-2}$. This results in a signal-to-background ratio of approximately two which is significantly higher than had previously been estimated. These signal-to-background rates are used to determine the time required to achieve a statistical uncertainty of 10\% on the number of 347\,keV X-rays as a function of the detector resolution and back ground rate. For a resolution of 2\,keV, and the background rate determined in this thesis, approximately one minute of data is required. The three corrections needed to be applied to the measured 347\,keV rate to determine the rate of stopped muons are also determined and potential sources of bias arising from the background shape, background fit range and energy calibration are investigated and found to be insignificant. The raw energy of the particles in the STM detector comes from a 16-bit ADC digitising at $\sim 300$\,MHz. It is not possible to store all the raw digitisations and online algorithms have been developed to rapidly select pulses in the detector and reconstruct their energy. The performance of these algorithms has been characterised with simulated data as a function of detector rate and resolution and optimum operating points for the algorithms have been defined. The integrity of the algorithms has also been demonstrated and characterised on test-beam data at high r ates and with radioactive sources at low rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-fidelity photoneutron detection via neutron activation analysis

To interdict illicit radioactive sources and prevent nuclear terror, governments have deployed portal monitor systems at ports of entry. Such portal monitors rely upon the detection of spontaneously-emitted radiation signatures, however, detection scenarios become more challenging for highly enriched uranium, which emits relatively few spontaneous radiation signatures. Photon active interrogation techniques can augment current cargo inspection scenarios and improve detection capabilities for illicit nuclear material. A high-energy photon interrogation source can induce photofission in nuclear material, producing strong radiation signatures for detection. Prompt fission signals are of specific interest because prompt neutrons are greater than 99% of the fission signal. When using detectors capable of spectroscopy, e.g., pulse shape discrimination-capable organic scintillators, the intense interrogating source often will cause pulse pile-up, degrading particle classification. In this work, we demonstrate photoneutron detection via neutron activation of aluminum and iron. The experiments rely upon nuclear reactions that can only be induced by neutrons, and are robust against pile-up, thereby providing high-confidence neutron rates. In this work, we apply neutron activation analysis for the detection of high-energy neutrons produced by high-energy photon irradiation; the depleted uranium sample was irradiated with a 9-MeV bremsstrahlung beam. We find that the irradiated depleted uranium produced an aluminum activation flux of 1.77 × 10 5 n cm –2 s –1 and an iron-56 activation flux of 1.05 × 10 5 n cm –2 s –1 . Furthermore, the ability to detect radioactivity induced by neutrons created in (, n) and photofission reactions demonstrates a new approach for photon active interrogation to identify nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probabilistic Risk Assessment of Spent Fuel Pool Cooling System Failure Considering Safety and Security Initiating Events

In order to quantify the probable risk associated with a safety system, nuclear safety risk evaluation process is applied which is generally performed in three steps. The first step is to calculate the damage frequency of a critical system. This step is followed by the radioactive source term estimation due to the potential system damage. The final step is the assessment of off-site consequences. The safety risk formula is shown by Eq. (1). P{sub F} is the probability of safety system failure (the probability used describes a random, independent event), and C is the consequence value. R{sub SAF} = P{sub F} * C (1) The security risk associated with an attack on critical infrastructure and/or special nuclear materials theft is usually evaluated using three- term risk equation (probability of attack, probability of adversary success, and consequence). A security threat and the related initiating events are not considered in a pure safety risk analysis. The vulnerability of the physical protection system is performed independently even though the consequence resulting from a security initiating event can be similar to a safety related initiating event and thus gets double counted. The security risk can be calculated using Eq. (2) R{sub SEC} = P{sub A} * P{sub S} * C (2) PA is the probability of attack, P{sub S} is the probability of adversary success (P{sub S} = 1 - P{sub I} P{sub N}). P{sub I} being the probability of interruption which accounts for the probabilities of detection of all timely detection elements along an adversary path. PN being the probability of neutralization: the result of engagement of the response force with the adversaries after the interruption has occurred. C is the consequence magnitude from a successful attack. The two security probabilities do not describe random, independent events. As a result, because of the differences in the randomness and independence of the respective safety and security probabilities, the safety and the security risks are currently calculated separately. The consequence term in nuclear safety and security risk evaluation have the same definition. An effort is made here to study the effect on the overall risk by considering security initiating events along with the subsequent failure of the intermediate safety element. The target selected is a spent fuel storage pool for analyzing the public risk arising from the interplay between nuclear security and safety initiating events. EASI (Estimate of Adversary Sequence Interruption) model is used to calculate the probability of interruption related to a security system that leads to the calculation of the security initiating event frequency. Further progression of this initiating security event to a top event is analyzed using a Probabilistic Safety Assessment (PSA) tool, SAPHIRE (version 8) to obtain a joint pool damage frequency. For the progression of events leading to a top event, the failure of the intermediate safety elements is assumed to be external random events such as heavy load drop and fire events. The objectives of this study is to (1) determine the double accounting of frequency of failure, risk and allocated resources in the scenario of a non-random security initiating event leading to a safety random event chain (2) compare the damage frequency from pure security with the frequency of combined security-safety failure event and pure safety failure events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anisotropy Characterization of I-125 Seed with Attached Encapsulated Cobalt Chloride Complex Contrast Agent Markers for MRI-Based Prostate Brachytherapy

We have developed a novel MRI marker for prostate brachytherapy. The purpose of this study was to evaluate the changes in anisotropy when cobalt chloride complex contrast agent encapsulated contrast agent markers (C4-ECAM) were placed adjacent to an iodine-125 (I-125) titanium seed, and to verify that the C4-ECAMs were visible on magnetic resonance imaging (MRI) after radiation exposure. Two C4-ECAMs were verified to be MRI visible in a phantom before radiation exposure. The C4-ECAMs were then attached to each end of a 12.7-U (10-mCi) I-125 titanium seed in a polymer tube. Anisotropy was measured and analyzed with the seed alone and with attached C4-ECAMs by suspending thermoluminescent dosimeters in a water phantom in 2 circles surrounding the radioactive source with radius of 1 or 2 cm. A T1-weighted MRI evaluation of C4-ECAMs was then performed after exposure to the amount of radiation typically delivered during 1 month of prostate brachytherapy. Measured values of the anisotropy function F(r, {theta}) for the I-125 seed with and without the C4-ECAMs were mutually statistically indistinguishable (standard error of the mean <4.2%) and agreed well with published TG-43 values for the bare seed. As expected, the anisotropy function {phi}{sub an}(r) for the 2 datasets (with and without C4-ECAMs) derived from the measured F(r, {theta}) did not exhibit statistically measurable difference. Both datasets showed agreement with the published TG-43 {phi}{sub an}(r) for the bare seed. The C4-ECAMs were well visualized by MRI after 1 month of radiation exposure. There were no changes in anisotropy when the C4-ECAMs were placed next to an I-125 radioactive seed, and the C4-ECAMs were visualized after radiation exposure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Moessbauer spectrometer for mineralogical analysis of the Mars surface: Moessbauer source considerations

Development of space rocketry and cosmic instrument making has made it possible to create interplanetary stations to be sent to the solar system bodies. In the last decade of the century the planet Mars will be in the focus of planetary science problems. Russia, USA (the NASA) and Europe (the ESA) plan to do a new step in the study of the planetary system by spacecraft missions to Mars. One part of the programs of these missions is Martian surface measurements of iron, which is a dominant element in both the Martian soil and rocks (about 13 percent by weight). The chemistry of iron in space is strongly coupled to the chemistry of abundant elements (to begin with hydrogen, carbon, oxygen) and it is this coupling of chemical cycles of abundant elements that gives us the possibility of understanding some features of the chemical evolution of matter. In this connection of extremely great importance for the understanding of the evolution of the solar system are the oxidation state of the iron and its mineral composition of the Mars surface. Being highly successful, the Viking landers had no instrumentation to answer these questions. Such instrumentation has to be specifically sensitive to mineralogy. For this purpose the back scattering Moessbauer spectrometer (MS-96) was proposed to be installed on a rover to be launched on board the Russian spacecraft Mars-96 mission to Mars. Due to power and mass restrictions three systems of the device MS-96 (velocity transducer, detector and electronic components) have been extremely miniaturized in comparison to a standard system. In this paper we intend to place for consideration a radioactive source to find out what characteristics it should have to be suitable for purposes of the experiment.

Evlanov, E. N.↗

Radioembolization Dosimetry: The Road Ahead

Methods for calculating the activity to be administered during yttrium-90 radioembolization (RE) are largely based on empirical toxicity and efficacy analyses, rather than dosimetry. At the same time, it is recognized that treatment planning based on proper dosimetry is of vital importance for the optimization of the results of RE. The heterogeneous and often clustered intrahepatic biodistribution of millions of point-source radioactive particles poses a challenge for dosimetry. Several studies found a relationship between absorbed doses and treatment outcome, with regard to both toxicity and efficacy. This should ultimately lead to improved patient selection and individualized treatment planning. New calculation methods and imaging techniques and a new generation of microspheres for image-guided RE will all contribute to these improvements. The aim of this review is to give insight into the latest and most important developments in RE dosimetry and to suggest future directions on patient selection, individualized treatment planning, and study designs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical significance of the sterile-neutrino hypothesis in the context of reactor and gallium data

We evaluate the statistical significance of the 3+1 sterile-neutrino hypothesis using $v_e$ and $\bar{v}_e$ disappearance data from reactor, solar and gallium radioactive source experiments. Concerning the latter, we investigate the implications of the recent BEST results. For reactor data we focus on relative measurements independent of flux predictions. For the problem at hand, the usual χ 2 -approximation to hypothesis testing based on Wilks’ theorem has been shown in the literature to be inaccurate. We therefore present results based on Monte Carlo simulations, and find that this typically reduces the significance by roughly 1σ with respect to the naïve expectation. We find no significant indication in favor of sterile-neutrino oscillations from reactor data. On the other hand, gallium data (dominated by the BEST result) show more than 5σ of evidence supporting the sterile-neutrino hypothesis, favoring oscillation parameters in agreement with constraints from reactor data. This explanation is, however, in significant tension (~3 σ) with solar neutrino experiments. In order to assess the robustness of the signal for gallium experiments we present a discussion of the impact of cross-section uncertainties on the results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broad sterile neutrinos & the reactor/gallium tension

Significant evidence exists for the apparent disappearance of electron-type neutrinos in radioactive source experiments. Yet, interpreted within the standard ‘3+1 sterile neutrino scenario’, precision short-baseline measurements of electron antineutrinos from nuclear reactors strongly disagree with these results. Recently, it has been demonstrated that allowing for a finite wavepacket size for the reactor neutrinos can ameliorate such a tension, however the smallness of the required wavepackets is a subject of intense debate. In this work, we demonstrate that a ‘broad’ sterile neutrino may relax this tension in much the same way. Such a phenomenological possibility can arise in plausible hidden sector scenarios, such as a clockwork-style sector, for which we provide a concrete microscopic model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle Response of Antenna-Coupled TES Arrays: Results from SPIDER and the Laboratory

Future mm-wave and sub-mm space missions will employ large arrays of multiplexed transition-edge-sensor (TES) bolometers. Such instruments must contend with the high flux of cosmic rays beyond our atmosphere that induce ‘glitches’ in bolometer data, which posed a challenge to data analysis from the Planck bolometers. Future instruments will face the additional challenges of shared substrate wafers and multiplexed readout wiring. Here, we explore the susceptibility of modern TES arrays to the cosmic ray environment of space using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic microwave background polarimeter, and a laboratory exposure of SPIDER flight hardware to radioactive sources. We find manageable glitch rates and short glitch durations, leading to minimal effect on SPIDER analysis. We constrain energy propagation within the substrate through a study of multi-detector coincidences and give a preliminary look at pulse shapes in laboratory data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Self-absorption Effects on Alpha-Induced Atmospheric Nitrogen Fluorescence Yield

Nitrogen fluorescence induced by alpha, beta and gamma radiation can be used to detect the presence of radioactive contamination in the environment. Successful measurement of fluorescence yield involves a number of factors, including: known fluorescence signal rate during the measurement; the effective alpha spectrum of the radioactive sources used in the measurement; optical attenuation length of the fluorescence signal in air during the measurement; the absolute throughput of the instrumentation; calibration of the instrumentation; and radiation transport modeling of the "effective" array exposure rate given the spectrum of the alpha particles. Field testing of optical instrumentation was conducted to measure the nitrogen fluorescence yield from the alpha radiation generated from americium-241 (241Am) decay. The 241Am test sources were prepared by direct evaporation of ~1 mCi in nitric acid solution, and some solids were visible on the surface of the sources. A laboratory study was conducted with lower activities of 241Am to determine whether the presence of solids on the surface of the sources prepared both by direct evaporation and by electrodeposition onto stainless steel disks produced sufficient self-absorption to cause a decrease in expected fluorescence. Alpha spectroscopy was used to determine the apparent activity of the sources versus the known activity deposited on the surface. Results from the self-absorption laboratory studies were used to correct the activity values in the model and calculate the nitrogen fluorescence generated by the 241Am during the field experiments.

36 MATERIALS SCIENCE↗

Gamma ray attenuation of hafnium dioxide- and tungsten trioxide-epoxy resin composites

Composites containing WO 3 or HfO 2 nanoparticles were prepared and investigated as alternative shielding materials. Their performance was assessed using radioactive sources emitting photons with energies between 122 and 1407 keV. At 122 keV, the mass attenuation coefficient of the nanocomposites was five times greater to that of the epoxy matrix, and it gradually decreased with increasing energy. An enhancement in the mass attenuation coefficient of the polymer between 15% and 50% was observed at E > 1 MeV when adding the nanoparticles. These results support the development of lightweight garments for radiological application made of nanomaterials and polymeric matrices.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Results from the third Galaxy Serpent tabletop exercise demonstrating the utility of nuclear forensics libraries in support of an investigation

Galaxy Serpent is a virtual, web-based international ongoing series of tabletop exercises designed to mature the concept of National Nuclear Forensics Libraries (NNFL) and illustrate their utility in answering investigative questions or providing investigative leads as part of an investigation involving nuclear or other radioactive material (R/N) out of regulatory control (MORC). Two prior versions of the exercise have been conducted; the first utilizing surrogate data for spent nuclear fuel as the material of interest, and the second using synthetic sealed radioactive source data. Teams participating in the recently concluded third version of the exercise were provided with synthetic uranium ore concentrate (UOC) data mimicking actual data characteristics (e.g. trace element concentrations), which was used to compile a model NNFL. Teams decided how to organize and interpret the data they were provided, dealt with real world features such as missing data, and assessed discriminating attributes. Next, a hypothetical scenario involving three UOC samples found out of regulatory control was provided, and each team had to assess the self-consistency of the individual sources in the unknown data, and employ their model NNFL as a comparative assessment instrument to determine whether the three UOC materials in question were consistent with any of the types of materials in their library. In conclusion, the design of the exercise, methodologies utilized by participating teams, and aggregate results of the exercise will be presented, along with challenges encountered and benefits realized.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Multifunctional Thin Film Based X-Ray Intensity Filters for Space-Based Payloads

We report the development, thorough characterizations and space worthiness studies of multifunctional aluminized film as x-ray intensity filter for space-based payloads, suitably designed to place in Sun–Earth Lagrangian (L1) point. The L1 point is the ideal location for uninterrupted observation of Sun to study the solar flares in hard x-rays. For our specific purpose, we make use of two different types of x-ray detectors (e.g., CdTe and CZT) which are generally used for hard x-ray studies in the energy band of 5 to 200 keV. Further, these aforesaid two detectors require specified thermal control characteristic for optimal performance. Aluminization of Kapton films is proposed which would satisfy the thermo-optical and x-ray transmission requirements of the proposed payload. The developed aluminized films are thoroughly studied by field emission scanning electron microscopy and atomic force microscopy techniques for micro-structural characteristic, x-ray diffraction for phase purity, nanoindentation for mechanical integrity at micro-structural length scale and spectrophotometer for thermo-optical properties. X-ray transmission test is carried out with two radioactive sources, namely {sup 55}Fe and {sup 241}Am, with various aluminized Kapton layer combinations. Finally, space worthiness of the aluminized Kapton films is examined by accelerated environments, e.g. humidity, thermal cycling and thermo-vacuum tests.

36 MATERIALS SCIENCE↗

Ir-192 radioisotope replacement with a hand-portable 1 MeV Ku-band electron linear accelerator

Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.

43 PARTICLE ACCELERATORS↗

American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee Report on Electronic Brachytherapy

The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗