Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Detecting Phase-Resolved Magnetization Dynamics by Magneto-Optic Effects at 1550 nm Wavelength

We demonstrate the detection of phase-resolved magnetization dynamics with combinatorial magneto-optic Kerr and Faraday effects. The method uses a continuous-wave laser that is amplitude-modulated at the spin dynamic frequencies, and thus allows for coherent tracking of the spin dynamics, akin a “lock-in” type measurement. In particular, our method, using a single 1550-nmwavelength, probes simultaneously the ferromagnetic resonance of Y 3 Fe 5 O 12 (YIG) and Permalloy (Py = Ni 80 Fe 20 ) in a YIG-Pyhetero structure. The fiber-based magneto-optic components also have the advantage of being made into a compact, tabletop or even portable system with yet robust measurement performances. We believe that our method will be found useful in studying hybrid quantum magnonic systems and/or investigating phase-resolved spin dynamics in nanomagnet structures involving both ferromagnetic insulators and metals.

42 ENGINEERING↗

Automating the interpretation of PM 2.5 time–resolved measurements using a data–driven approach

The rapid development of automated measurement equipment enables researchers to collect greater quantities of time-resolved data from indoor and outdoor environments. While significant, the interpretation of the resulting data can be a time-consuming effort. This paper introduces an automated process of interpreting PM 2.5 time-resolved data and differentiating PM 2.5 emissions resulting from indoor and outdoor sources. Here, we use Random Forest (RF), a machine learning approach, to study a dataset of 836 indoor emission events that occurred over a 2-week period in 18 apartments in California. In this paper, we show model development and evaluate its performance as the sample size and source vary. We discuss the characteristics of the dataset that tended to help the source identification and why. For example, we show that data from many events and from different apartments are essential for the model to be suitable for analyzing a new separate dataset. We also show that longitudinal data appear to be more helpful than the time frequency of measurements within a given apartment. We use the resulting RF model to analyze PM 2.5 data of an entirely separate dataset collected from 65 new homes in California. The RF model identifies 442 indoor emission events, with only a few misidentifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

A new mechanism for void-cascade interaction from nondestructive depth-resolved atomic-scale measurements of ion irradiation–induced defects in Fe

The nondestructive investigation of single vacancies and vacancy clusters in ion-irradiated samples requires a depth-resolved probe with atomic sensitivity to defects. The recent development of short-pulsed positron beams provides such a probe. Here, we combine depth-resolved Doppler broadening and positron annihilation lifetime spectroscopies to identify vacancy clusters in ion-irradiated Fe and measure their density as a function of depth. Despite large concentrations of dislocations and voids in the pristine samples, positron annihilation measurements uncovered the structure of vacancy clusters and the change in their size and density with irradiation dose. When combined with transmission electron microscopy measurements, the study demonstrates an association between the increase in the density of small vacancy clusters with irradiation and a remarkable reduction in the size of large voids. This, previously unknown, mechanism for the interaction of cascade damage with voids in ion-irradiated materials is a consequence of the high porosity of the initial microstructure.

36 MATERIALS SCIENCE↗

Time-resolving state-specific molecular dissociation with XUV broadband absorption spectroscopy

The electronic and nuclear dynamics inside molecules are essential for chemical reactions, where different pathways typically unfold on ultrafast timescales. Extreme ultraviolet (XUV) light pulses generated by free-electron lasers (FELs) allow atomic-site and electronic-state selectivity, triggering specific molecular dynamics while providing femtosecond resolution. Yet, time-resolved experiments are either blind to neutral fragments or limited by the spectral bandwidth of FEL pulses. Here, we combine a broadband XUV probe pulse from high-order harmonic generation with an FEL pump pulse to observe dissociation pathways leading to fragments in different quantum states. We temporally resolve the dissociation of a specific O 2 + state into two competing channels by measuring the resonances of ionic and neutral fragments. This scheme can be applied to investigate convoluted dynamics in larger molecules relevant to diverse science fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolved photons in S HERPA

We present the first complete simulation framework, in the SHERPA event generator, for resolved photon interactions at next-to leading order accuracy. It includes photon spectra obtained through the equivalent-photon approximation, parton distribution functions to parametrize the hadronic structure of quasi-real photons, the matching of the parton shower to next-to leading order QCD calculations for resolved photon cross sections, and the modelling of multiple-parton interactions. We validate our framework against a wide range of photo-production data from LEP and HERPA experiments, observing good overall agreement. We identify important future steps relevant for high-quality simulations at the planned Electron–Ion Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatially resolved characterization of optical and recombination losses for different industrial silicon solar cell architectures

In this work, spatially resolved characterization methods are used to identify loss mechanisms for common p -type silicon solar cell architectures, including multicrystalline aluminum back surface field (Al-BSF), monocrystalline Al-BSF, monocrystalline passivated emitter and rear cells (PERC), and bifacial monocrystalline PERC. The characterization methods used in this work include suns-V OC , photoluminescence imaging, and spatially resolved external quantum efficiency and reflectance measurements. The optical and recombination losses are driven by the material properties, cell processing conditions, and device architecture. These losses are quantified and categorized in terms of underlying mechanisms (e.g., front reflectance, escape reflectance, front recombination, and parasitic optical absorption and recombination in the bulk and rear). The ability to create images of these loss parameters can be used to gain more insight into the materials and manufacturing processes used to produce solar cells, and examples are given in this work to illustrate how these images can help reveal the origin of defects.

14 SOLAR ENERGY↗

The Simple Cloud-Resolving E3SM Atmosphere Model Running on the Frontier Exascale System

We present an efficient and performance portable implementation of the Simple Cloud Resolving E3SM Atmosphere Model (SCREAM). SCREAM is a full featured atmospheric global circulation model with a nonhydrostatic dynamical core and state-of-the-art parameterizations for microphysics, moist turbulence and radiation. It has been written from scratch in C++ with the Kokkos library used to abstract the on-node execution model for both CPUs and GPUs. SCREAM is one of only a few global atmosphere models to be ported to GPUs. As far as we know, SCREAM is the first such model to run on both AMD GPUs and NVIDIA GPUs, as well as the first to run on nearly an entire Exascale system (Frontier). On Frontier, we obtained a record setting performance of 1.26 simulated years per day for a realistic cloud resolving simulation.

Taylor, Mark↗

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗

Climate Sensitivity and the Direct Effect of Carbon Dioxide in a Limited-Area Cloud-Resolving Model

Even in a small domain, it can be prohibitively expensive to run cloud-resolving greenhouse gas warming experiments due to the long equilibration time. Here, a technique is introduced that reduces the computational cost of these experiments by an order of magnitude: instead of fixing the carbon dioxide concentration and equilibrating the sea surface temperature (SST), this technique fixes the SST and equilibrates the carbon dioxide concentration. Using this approach in a cloud-resolving model of radiative–convective equilibrium (RCE), the equilibrated SST is obtained as a continuous function of carbon dioxide concentrations spanning 1 ppmv to nearly 10 000 ppmv, revealing a dramatic increase in equilibrium climate sensitivity (ECS) at higher temperatures. This increase in ECS is due to both an increase in forcing and a decrease in the feedback parameter. In addition, the technique is used to obtain the direct effects of carbon dioxide (i.e., the rapid adjustments) over a wide range of SSTs. Overall, the direct effect of carbon dioxide offsets a quarter of the increase in precipitation from warming, reduces the shallow cloud fraction by a small amount, and has no impact on convective available potential energy (CAPE).

Romps, David M.↗

Vertically Resolved Convective–Stratiform Echo-Type Identification and Convectivity Retrieval for Vertically Pointing Radars

Using data from the airborne HIAPER Cloud Radar (HCR), a partitioning algorithm (ECCO-V) that provides vertically resolved convectivity and convective versus stratiform radar-echo classification is developed for vertically pointing radars. The algorithm is based on the calculation of reflectivity and radial velocity texture fields that measure the horizontal homogeneity of cloud and precipitation features. The texture fields are translated into convectivity, a numerical measure of the convective or stratiform nature of each data point. The convective–stratiform classification is obtained by thresholding the convectivity field. Subcategories of low, mid-, and high stratiform, shallow, mid-, deep, and elevated convective, and mixed echoes are introduced, which are based on the melting-layer and divergence-level altitudes. As the algorithm provides vertically resolved classifications, it is capable of identifying different types of vertically layered echoes, and convective features that are embedded in stratiform cloud layers. Its robustness was tested on data from four HCR field campaigns that took place in different meteorological and climatological regimes. The algorithm was adapted for use in spaceborne and ground-based radars, proving its versatility, as it is adaptable not only to different radar types and wavelengths, but also different research applications.

54 ENVIRONMENTAL SCIENCES↗

Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.

Chan, George C. -Y.↗

Spatially Resolved Raman Spectroscopic Investigation of Uranyl Fluoride: A Case Study in the Importance of Instrument Optimization

Raman spectroscopy is an emerging technique for rapid and nondestructive analysis of nuclear materials for forensic and nonproliferation applications as it is a powerful tool for distinguishing multiple chemical forms of materials with similar stoichiometries. Recent developments in spectroscopic software have enabled rapid data collection with high-speed Raman spectroscopic mapping capabilities. However, some uranium-rich materials are susceptible to degradation in humid air and/or laser-induced phase transformations. To mitigate environmental or measurement-related sample degradation of potential samples of interest, we have taken a systematic approach to define optimized data collection parameters for high-throughput measurements of uranyl fluoride (UO 2 F 2 ), which is an important intermediate material in the nuclear fuel cycle. First, we systematically describe the influence of optical magnification (5× to 100×), laser power, and exposure time on obtained signal for identical particles of UO 2 F 2 and find that at low laser power and exposure times, comparable signal is obtained regardless of optical magnification. Second, we ensure sample integrity during data collection, and third, collect spectroscopic maps that employ optimized parameters to reduce the time required to obtain spatially resolved spectroscopic information. Reductions of 90% and 99% in measurement times are discussed as they relate to differences in resolving spectroscopic features of particles in identical mapping areas. Finally, during this work, we found that additional data processing options were needed and thus developed a customized Python script for importing, processing, analyzing, and visualizing Raman spectroscopic map data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High temporal frequency data from a four turbine, blade-resolved wind farm simulation with ExaWind

The data was generated with ExaWind (https://github.com/Exawind) which couples AMR-Wind (https://github.com/Exawind/amr-wind/), Nalu-Wind (https://github.com/Exawind/nalu-wind), TIOGA (https://github.com/Exawind/tioga), and OpenFAST (https://github.com/OpenFAST/openfast). This is a large-scale simulation of a blade-resolved wind farm using the ExaWind software stack. ExaWind couples together a background flow solver, AMR-Wind, and a near-body solver, Nalu-Wind, through an overset technique from the TIOGA application. Another application, OpenFAST, handles the structural dynamics of the turbine blades and towers, which informs the fluid-structure interaction of the wind turbines with the flow solvers. This particular simulation includes four blade-resolved wind turbines operating in a turbulent atmospheric boundary layer. The AMR-Wind solver uses 500 million cells and is being solved on 256 AMD GPUs of the Oakridge Leadership Computing Facility Frontier supercomputer. Each turbine is assigned its own Nalu-Wind solver with over 13 million elements per turbine and solved using 448 CPU cores, for a total of 1792 CPU cores. For each node, 56 cores contain Nalu-Wind, while 8 cores correspond to AMR-Wind operations on the GPUs. Consequently, ExaWind is entirely utilizing the CPUs and the GPUs of the nodes concurrently. The data used in the visualization is full flow field data output from the simulation. It is lossy-compressed to a specific accuracy using ZFP and written to disk every 16 time-steps to enable real-time flow visualization. The flow fields are sampled at a high temporal frequency to enable real-time, 24fps visualization. The flow fields are sampled every 12 simulation time steps (every 0.04132s).

17 WIND ENERGY↗

High-harmonic spin-shearing interferometry for spatially resolved EUV magneto-optical spectroscopy

We present a method for achieving hyperspectral magnetic imaging in the extreme ultraviolet (EUV) region based on high-harmonic generation (HHG). By interfering two mutually coherent orthogonally-polarized and laterally-sheared HHG sources, we create an EUV illumination beam with spatially-dependent ellipticity. By placing a magnetic sample in the beamline and sweeping the relative time delay between the two sources, we record a spatially resolved interferogram that is sensitive to the EUV magnetic circular dichroism of the sample. This image contains the spatially-resolved magneto-optical response of the sample at each harmonic order, and can be used to measure the magnetic properties of spatially inhomogeneous magnetic samples.

Optics↗

Expanding the range of the resolvable strain from distributed fiber optic sensors using a local adaptive reference approach

Optical frequency domain reflectometry (OFDR) is a spectral measurement technique in which shifts in the local Rayleigh backscatter spectra can be used to perform distributed temperature or strain measurements relative to a reference measurement using ordinary single-mode optical fibers. Here, we demonstrate a data processing methodology for improving the resolvable range of temperature and strain by adaptively varying the reference measurement position by position, based on the time evolution of the local optical intensities and the correlation between the reference and active measurements. These methods nearly double the resolvable range of temperature and strain compared with that achieved using the traditional static reference approach.

47 OTHER INSTRUMENTATION↗