Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLVING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Temporal Gain Correction for X-Ray Calorimeter Spectrometers

Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-HSXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 104 over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

X-ray detector X-ray spectrometer X-ray calorimete↗

In-Flight Performance of the Soft X-Ray Spectrometer Detector System on ASTRO-H

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 microsecond. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.

X-ray astrophysics↗

Fabrication of Ultrasensitive Transition Edge Sensor Bolometric Detectors for HIRMES

The high resolution mid-infrared spectrometer (HIRMES) is a high resolving power (R approx. 100,000) instrument operating in the 25-122 micron spectral range and will fly on board the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA) in 2019. Central ot HIRMES are its two transition edge sensor (TES) bolometric cameras, an 8x16 detector high resolution array and a 64x16 detector low resolution array. Both types of detectors consist of MoAu TES fabricated on leg-isolated Si membranes. Whereas the high resolution detectors, with noise equivalent power (NEP) approx. 2 aW/square root of (Hz), are fabricated on 0.45 micron Si substrates, the low resolution detectors, with NEP approx. 10 aW/square root of (Hz), are fabricated on 1.40 micron Si. Here we discuss the similarities and difference in the fabrication methodologies used to realize the two types of detectors.

Detectors↗

NASA's Orgins Space Telescope Mission and Its Synergies with SOFIA

The Origins Space Telescope (OST) is the mission concept for the Far Infrared Surveyor, a study in development by NASA in preparation for the 2020 Astronomy and Astrophysics Decadal Survey. The science program that has been selected to drive the OST performance requirements is broad, covering four main themes: Charting the Rise of Metals, Dust, and the First Galaxies; Unveiling the Growth of Black Holes and Galaxies Over Cosmic Time; Tracing the Signatures of Life and the Ingredients of Habitable Worlds; and Characterizing Small Bodies in the Solar System. The OST telescope itself will have a primary mirror diameter of 8-15 m (depending on the launch vehicle that is selected), will be diffraction-limited at 40m, and will be actively cooled to approximately 5K. Five science instruments have been base-lined for the observatory: a heterodyne instrument covering 150-500 m with a spectral resolving power of R1e7; a low-spectral resolution (R500) spectrometer covering 35-500 m; a high-spectral resolution (R1e5) spectrometer covering 50-500 m; a far-infrared imager (R15) covering 35-500m; and a mid-infrared imagerspectrometer (R15-500) covering 6-40m. In addition to having a vastly higher sensitivity than the corresponding SOFIA instrumentation that will allow more detailed follow-up of SOFIAs discoveries, the OST mission will be configured to provide efficient large-area mapping, which will further complement SOFIAs science capabilities by providing new targets for study by SOFIA. Furthermore, new SOFIA instruments can provide an excellent testbed for the advanced far-infrared detector technologies what will be required to achieve the anticipated OST performance.

Mission↗

The Magellan Evolution of Galaxies Spectroscopic and Ultraviolet Reference Atlas (MegaSaura). I. the Sample and the Spectra

We introduce Project MEGaSaURA: the Magellan Evolution of Galaxies Spectroscopic and Ultraviolet Reference Atlas. MEGaSaURA comprises medium-resolution, rest-frame ultraviolet spectroscopy of N = 15 bright gravitationally lensed galaxies at redshifts of 1.68 less than z less than 3.6, obtained with the MagE spectrograph on the Magellan telescopes. The spectra cover the observed-frame wavelength range 3200 less than (lamda(sub o)) less than 8280 Angstroms; the average spectral resolving power is R = 3300. The median spectrum has a signal-to-noise ratio (S/N) = 21 per resolution element at 5000 Angstroms. As such, the MEGaSaURA spectra have superior S/N and wavelength coverage compared to what COS/HST provides for starburst galaxies in the local universe. This paper describes the sample, the observations, and the data reduction. We compare the measured redshifts for the stars, the ionized gas as traced by nebular lines, and the neutral gas as traced by absorption lines; we find the expected bulk outflow of the neutral gas, and no systemic offset between the redshifts measured from nebular lines and the redshifts measured from the stellar continuum. We provide the MEGaSaURA spectra to the astronomical community through a data release.

Rigby, J. R.↗

A Hybrid Line List for CH4 and Hot Methane Continuum

Molecular line lists (a catalogue of transition frequencies and line strengths) are important for modelling absorption and emission processes in atmospheres of different astronomical objects, such as cool stars and exoplanets. In order to be applicable for high temperatures, line lists for molecules like methane must contain billions of transitions, which makes their direct (line-by-line) application in radiative transfer calculations impracticable. Here we suggest a new, hybrid line list format to mitigate this problem, based on the idea of temperature-dependent absorption continuum. Methods. The line list is partitioned into a large set of relatively weak lines and a small set of important, stronger lines. The weaker lines are then used either to construct a temperature-dependent (but pressure-independent) set of intensity cross sections or are blended into a greatly reduced set of super-lines. The strong lines are kept in the form of temperature independent Einstein A coefficients. Results. A line list for methane is constructed as a combination of 17 million strong absorption lines relative to the reference absorption spectra and a background methane continuum in two temperature-dependent forms, of cross sections and super-lines. This approach eases the use of large high temperature line lists significantly as the computationally expensive calculation of pressure dependent profiles only need to be performed for a relatively small number of lines. Both the line list and cross sections were generated using a new 34 billion methane line list (34 to10), which extends the 10to10 line list to higher temperatures (up to 2000 K). The new hybrid scheme can be applied to any large line lists containing billions of transitions. We recommend to use super-lines generated on a high resolution grid based on resolving power R = 1,000,000 to model the molecular continuum as a more flexible alternative to the temperature dependent cross sections.

Line Profiles↗

Infrared Transmission Spectroscopy of the Exoplanets HD 209458b and XO-1b Using the Wide Field Camera-3 on the Hubble Space Telescope

Exoplanetary transmission spectroscopy in the near-infrared using the Hubble Space Telescope (HST) NICMOS (Near Infrared Camera and Multi-Object Spectrometer) is currently ambiguous because different observational groups claim different results from the same data, depending on their analysis methodologies. Spatial scanning with HST/WFC3 (Wide Field Camera-3) provides an opportunity to resolve this ambiguity.We here report WFC3 spectroscopy of the giant planets HD 209458b and XO-1b in transit, using spatial scanning mode for maximum photon-collecting efficiency. We introduce an analysis technique that derives the exoplanetary transmission spectrum without the necessity of explicitly decorrelating instrumental effects, and achieves nearly photon-limited precision even at the high flux levels collected in spatial scan mode. Our errors are within 6 percent (XO-1) and 26 percent (HD 209458b) of the photon-limit at a resolving power of lambda divided by delta times lambda approximating 70, and are better than 0.01 percent per spectral channel. Both planets exhibit water absorption of approximately 200 ppm at the water peak near 1.38 m. Our result for XO-1b contradicts the much larger absorption derived from NICMOS spectroscopy. The weak water absorption we measure for HD209458b is reminiscent of the weakness of sodium absorption in the first transmission spectroscopy of an exoplanet atmosphere by Charbonneau et al. Model atmospheres having uniformly distributed extra opacity of 0.012 square centimeters per gram account approximately for both our water measurement and the sodium absorption. Our results for HD 209458b support the picture advocated by Pont et al. in which weak molecular absorptions are superposed on a transmission spectrum that is dominated by continuous opacity due to haze and or dust. However,the extra opacity needed for HD 209458b is grayer than for HD 189733b, with a weaker Rayleigh component.

planetary systems↗

The GeoCarb Mission: One Tool in the Evolving Understanding of Methane and Carbon Monoxide Budgets

NASA plans to operate an instrument in geostationary orbit over the Americas beginning in 2022. This mission allows a coordinated study of climate-determining carbon species. Prime focus is on CO2 fluxes, but the reactive species CO and CH4 are particularly relevant to IGAC. Measurements of solar-induced fluorescence will describe plant photosynthesis contemporaneous with emissions. To outline the technology: Grating mapping spectrometery, using a single slit and four focal planes set at 0.76, 1.60, 2.07, and 2.32 microns and ~17000 resolving power. Retrieval profiting from the rich heritage of OCO-2, GOSAT, TropOMI, and GOME/SCIAMACHY. Column concentrations of CO2, CH4, and CO, with finest resolution at 3 km x 6 km. A selection of scans allowing appreciable refinement in fluxes of CO2 and CH4. Rapid re-pointing allowing at least one synoptic observation of all North and South America daily, and 3 observations through the day for selected areas.This presentation is an appeal to IGAC community to use GeoCarb to help improve the attribution of fluxes by sector and by geography. Cost constraints allow GeoCarb only limited listed goals. For example, GeoCarb aspires to constrain CH4 emissions for the whole US, closing the ~60% gap between US EPA estimation and 3-d models. Detailed CO measurements should also aid photochemical and aerosol studies. NASA's TEMPO (UV-Vis geostationary) instrument will overlap GeoCarb. Consequently, HCHO, NO2, aerosol, and CO may be intercompared, allowing elucidation of chemical sources and also transformation timescales. We expect that Sentinel-5P's TropOMI will lead the way here; geostationary imaging will allow diurnal views and reduced cloud obscuration of interesting areas. Analysis of current data suggests interesting questions: (a) puzzling XCH4 diel variations in the Amazonian rainforest; (b) time-varying CO/NO2 relationships in urban plumes. We also urge the suite of airborne and small-sat measurements needed to complete the story at fine scales.

Chatfield, Robert B.↗

Picture this SELFI: Submillimeter Enceladus Life Fundamentals Instrument

The Submillimeter Enceladus Life Fundamentals Instrument (SELFI) is a passive remote sensing submillimeter heterodyne spectrometer being developed at NASA GSFC under NASA's Maturation of Instruments for Solar System Exploration (MatISSE) program. SELFI will advance submillimeter receiver technology by 1) investigating the chemical and isotopic compositions and corresponding densities of Enceladus' plume material, their vertical thermal structures, and the transport mechanisms within the plumes, and 2) characterizing the source regions from which the plumes emerge. The Enceladus plumes are important in the context of life and habitability of its subsurface ocean environment. SELFI remote sensing measurements will 1) measure the spatial and temporal variabilities in the plume chemical compositions, 2) provide insight in to Enceladus' subsurface ocean environment by monitoring H2O, HDO, d18O, and d17O, 3) constrain the oxidation state of the subsurface ocean using H2O2 and O3, and 4) utilize the SO2 and H2S spectral signatures to constrain the impact arising from both the sea-floor volcanoes and pre-biotic molecules. Moreover, the detection of the remaining molecular species (14 in total) is vital to improving the current state of knowledge of Enceladus' subsurface ocean habitability this also permits us to explore the chemical alteration processes arising from primordial volatiles that have been observed in comets. Lastly, SELFI's continuum observations enable the correlation between observed variations in plume activity with surface temperatures.SELFI is currently being developed under a technology maturation program that will advance the RF-to-digital electronics of a submillimeter-wave heterodyne spectrometer to simultaneously observe fourteen molecular species with resonances between 530 GHz and 600 GHz. SELFI will have fine radiometric resolution, high spectral resolution (resolving power R > 106), multiple continuum channels and a high dynamical range, necessary to map Enceladus across its 30 K to 250 K temperature range. Under the MatISSE program, SELFI will advance from TRL 4 to 6 four key technologies of the RF-to-digital subsystem, which are: 1) the RF low noise amplifier design; 2) the single-sideband (SSB) mixer and local oscillator; 3) the IF assembly down-converter that maps the fourteen species to 2 x 500 MHz bandwidth; and 4) the digital spectrometer electronics.

Racette, Paul↗

Optical Design for CETUS a Wide-Field 1.5-m Aperture UV Payload Being Studied for a NASA Probe Class Mission Study

As part of a study funded by NASA headquarters, we are developing a probe-class mission concept called the Cosmic Evolution through UV Spectroscopy (CETUS). CETUS includes a 1.5-m aperture diameter telescope with a large field of view (FOV). CETUS includes three scientific instruments: a far ultraviolet (FUV) and near ultraviolet (NUV) imaging camera (CAM); a NUV multiobject spectrograph (MOS); and a dual-channel point/slit spectrograph (PSS) in the Lyman ultraviolet (LUV), FUV, and NUV spectral regions. The large FOV three-mirror anastigmatic (TMA) optical telescope assembly (OTA) simultaneously feeds the three separate scientific instruments. That is, the instruments view separate portions of the TMA image plane, enabling parallel operation by the three instruments. The field viewed by the MOS, whose design is based on an Offner-type spectrographic configuration to provide wide FOV correction, is actively configured to select and isolate numerous field sources using a next-generation micro-shutter array. The two-channel CAM design is also based on an Offner-like configuration. The PSS performs high spectral resolution spectroscopy on unresolved objects over the NUV region with spectral resolving power, R ~ 40,000, in an echelle mode. The PSS also performs long-slit imaging spectroscopy at R ~ 20,000 in the LUV and FUV spectral regions with two aberration-corrected, blazed, holographic gratings used in a Rowland-like configuration. The optical system also includes two fine guidance sensors, and wavefront sensors that sample numerous locations over the full OTA FOV. In-flight wavelength calibration is performed by a wavelength calibration system, and flat-fielding is also performed, both using in-flight calibration sources. We describe the current optical design of CETUS and the major trade studies leading to the design.

space sensors↗

Decomposition of Electron Ionization Mass Spectra for Space Application Using a Monte-Carlo approach

Rationale: Quadrupole mass spectrometers equipped with an electron ionization (EI) sources have been widely used in space exploration to investigate the composition of planetary surfaces and atmospheres. However, the complexity of the samples and the minimal calibration for the fragmentation of molecules in the ionization chambers have prevented the deconvolution of the majority of the mass spectra obtained at different targets, thus limiting the determination of the exact composition of the samples analyzed. We propose a Monte‐Carlo approach to solve this issue mathematically. Methods: We decomposed simulated mass spectra of mixtures acquired with unit resolving power mass spectrometers and EI sources into the sum of the single components fragmentation patterns weighted by their relative concentration using interior‐point least‐square fitting. To fit compounds with poorly known fragmentation patterns, we used a Monte‐Carlo method to vary the intensity of individual fragment ions. We then decomposed the spectrum thousands of times to obtain a statistical distribution. Results: By performing the deconvolution on a mixture of seven different molecules with interfering fragmentation patterns (H2O, O2, CH4, Ar, N2, C2H4, and C2H6) we show that this approach retrieves the mixing ratio of the individual components more accurately than regular mass spectra decomposition methods that rely on fragmentation patterns from general databases. It also provides the probability density function for each species's mixing ratio. Conclusions: By removing the solution degeneracy in the decomposition of mass spectra, the method described herein could significantly increase the scientific retrieval from archived space flight mass spectrometry data, where calibration of the ionization source is no longer an option.

Thomas Gautier↗

A Computer Program to Generate Tri-Truss Structures for On- and Off-Axis Telescope Dishes

The size of traditional space telescopes has been limited by the size of the launch vehicle shroud size. Designs of space telescopes with larger apertures and greater resolving power can be achieved with multiple launches incorporating modular elements and in-space assembly techniques. The modular elements of an in-space assembled telescope include segmented reflectors supported on an assembled truss structure. The modular truss structures are most commonly based on a tessellation of triangles across a reflector’s surface, and in some cases utilize deployable trusses to simplify in-space assembly. One design effort, the in-Space Assembled Telescope (iSAT), proposes the use of deployable “tri-truss” modules to form an off-set parabolic reflector. In support of the iSAT, a computer program was developed to tesselate tri-truss modules over a parabolic surface. Based on several user-defined variables, the program renders a tri-truss structure and generates a stereolithography file of the generated truss structure for three dimensional (3D) printing. In addition, due to the importance of packing efficiency for space launch, the program attempts to minimize unnecessary differences in strut lengths using a grade parameter based on previous work.

Structures↗

u-Spec Spectrometers for the EXCLAIM Instrument

The EXperiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases, and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM’s cryogenic telescope features sixμ-Spec spectrometers.μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from420−540 GHz with a resolving power R=λ/∆λ= 512, and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2×10−18W/√Hz (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9◦half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.

EXCLAIM Instrument↗

CARBO - The Carbon Observatory Instrument Suite - The Next Generation of Earth Observing Instruments for Global Monitoring of Carbon Gases

The Carbon Observatory Instrument Suite, or CARBO, consists of four carbon observing instruments sharing a common instrument bus, yet targeted for a particular wavelength band each with a unique science observation. They are: a) Instrument 1, wavelength centered at 756 nm for oxygen and solar-induced chlorophyll fluorescence (SIF) observations, b) Instrument 2, centered at 1629 nm, for carbon dioxide (CO2) and methane (CH4) observation, c) Instrument 3, centered at 2062 nm for carbon dioxide and d) Instrument 4, centered at 2328 for carbon monoxide (CO) and methane. From low-Earth orbit, these instruments have a field-of-view of 10 to 15 degrees, and a spatial resolution of 2 km square. These instruments have a spectral resolving power ranging from ten to twenty thousand, and can monitor columnaverage dry air mole fraction of carbon dioxide (XCO2) at 1.5 ppm, and methane (XCH4) at 7 ppb. These new instruments will advance the use of immersion grating technology in spectrometer instruments in order to reduce the size of the instrument, while improving performance. These compact, capable instruments are envisioned to be compatible with small satellites, yet modular to be configured to address the particular science questions at hand. Here we report on the current status of the instrument design and fabrication, focusing primarily on Instruments 1 and 2. We will describe the key science and engineering requirements and the instrument performance error budget. We will discuss the optical design with particular emphasis on the immersion grating, and the advantages this new technology affords compared to previous instruments. We will also discuss the status of the focal plane array and the detector electronics and housing. Finally, we report on a new approach – developed during this instrument design process - which enables simultaneous measurement of both orthogonal polarization states (S and P) over the field-of-view and optical bandpass. We believe this polarization sensing capability will enable science observations which were previously limited by instrumental and observational degeneracies. In particular: improved sensitivity to all species, better sensitivity to surface polarization effects, better constraints on aerosol scattering parameters, and superior discrimination of the vertical distribution of gases and aerosols.

Bernas, Michael↗

Origins Survey Spectrometer: revealing the hearts of distant galaxies and forming planetary systems with far-IR spectroscopy

The Origins Survey Spectrometer (OSS) is a multi-purpose far-IR spectrograph for Origins. Operating at the photon background limit, OSS covers the 25- to 588-μm wavelength range instantaneously at a resolving power (R) of 300 using six logarithmically spaced grating modules. Each module couples at least 30 and up to 100 spatial beams simultaneously, enabling true [three-dimensional (3D)] spectral mapping. In addition, OSS provides two high-resolution modes. The first inserts a long-path Fourier-transform spectrometer (FTS) into a portion of the incoming light in advance of the grating backends, enabling R up to 43,000 × [λ/112 μm] , while preserving the grating-based sensitivity for line detection. The second incorporates a scanning etalon in series with the FTS to provide R up to 300,000 for the 100-to 200-μm range.

Charles M. Bradford↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz (10¯11) crystal.

M. J. MacDonald↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through measurement of atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R=512 and employing microwave kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out an intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R = 512 and employing kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗