Search NASA⌕ Search

SEARCH · Search NASA

Results for “Range Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Electric Utility Distribution Costs: Scoping Study on Trends, Drivers, and Possible Response Strategies [Slides]

This scoping study synthesizes information that will help stakeholders understand the scope, scale, and drivers of recent increases in investor-owned utility (IOU) expenditures on local distribution power grids, while providing regulators and other decision-makers with potential strategies to keep electricity bills down. The study includes five distinct components. Drawing first on data from FERC Form 1, it summarizes key trends in past and recent IOU distribution costs. Next, through a review of a sample of distribution-system plans, it characterizes material drivers of planned distribution expenditures. Ultimately, regulators must approve cost recovery for IOU expenditures, including those for the distribution system. The study therefore also: examines trends in utility requests and regulatory approvals related to changes in retail rates and return on equity; identifies areas where utility shareholder and customer incentives may be misaligned; and develops a menu of options that state regulators might consider to optimize distribution system expenditures. Some of the key findings include: - IOU distribution spending at a national level has grown by 6%/yr since 2014 in real dollar terms, 4x faster than in the prior 20 years and consisting mostly of capital (not operating) expenditure. - On a per-kWh basis, increases in IOU distribution costs since 2014 represent over 30% of the overall national-average increase in retail electricity rates. - Regional spending growth has ranged from 2-8%/yr, with larger estimated rate impacts in CAISO, then NYISO & ISO-NE, and then the Southeast, MISO & PJM (see figure). - Some utilities are planning for significantly increased distribution system spending. Planned spending on managing the existing system (asset replacement, safety & reliability, and resilience are all important drivers) exceeds that for capacity expansion. - IOU rate increase requests ($18 billion in 2025) and public utility commission (PUC) approval levels (average of 64% of requested amounts from 2021-2025) have recently hit multi-decadal highs. - PUCs in New England and the Southeast have recently approved a greater fraction of rate requests (>75%, on average) than in ther regions, while PUCs in California and the Southeast have generally authorized higher equity returns than in other regions. - Regulators have many tools to tackle potential misalignments between utility and customer interests and, more specifically, to optimize and reduce distribution costs. Shorter-term options include those related to return on equity, capital structure, depreciation, trackers, construction work in progress, and securitization. Longer-term options include performance-based regulation and a wide variety of planning-related requirements. All options embed important tradeoffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiplex detection and identification of viral, bacterial, and protozoan pathogens in human blood and plasma using an expanded high-density resequencing microarray platform

Introduction: Nucleic acid tests for blood donor screening have improved the safety of the blood supply; however, increasing numbers of emerging pathogen tests are burdensome. Multiplex testing platforms are a potential solution. Methods: The Blood Borne Pathogen Resequencing Microarray Expanded (BBP-RMAv.2) can perform multiplex detection and identification of 80 viruses, bacteria and parasites. This study evaluated pathogen detection in human blood or plasma. Samples spiked with selected pathogens, each with one of 6 viruses, 2 bacteria and 5 protozoans were tested on this platform. The nucleic acids were extracted, amplified using multiplexed sets of primers, and hybridized to a microarray. The reported sequences were aligned to a database to identify the pathogen. To directly compare the microarray to an emerging molecular approach, the amplified nucleic acids were also submitted to nanopore next generation sequencing (NGS). Results: The BBP-RMAv.2 detected viral pathogens at a concentration as low as 100 copies/ml and a range of concentrations from 1,000 to 100,000 copies/ml for all the spiked pathogens. Coded specimens were identified correctly demonstrating the effectiveness of the platform. The nanopore sequencing correctly identified most samples and the results of the two platforms were compared. Discussion: These results indicated that the BBP-RMAv.2 could be employed for multiplex detection with potential for use in blood safety or disease diagnosis. The NGS was nearly as effective at identifying pathogens in blood and performed better than BBP-RMAv.2 at identifying pathogen-negative samples.

59 BASIC BIOLOGICAL SCIENCES↗

Lithium Plating Characteristics in High Areal Capacity Li-Ion Battery Electrodes

Li-ion battery degradation and safety events are often attributed to undesirable metallic lithium plating. Since their release, Li-ion battery electrodes have been made progressively thicker to provide a higher energy density. However, the propensity for plating in these thicker pairings is not well understood. Herein, we combine an experimental plating-prone condition with robust mesoscale modeling to examine electrode pairings with capacities ranging from 2.5 to 6 mAh/cm 2 and negative to positive (N/P) electrode areal capacity ratio from 0.9 to 1.8 without the need for extensive aging tests. Using both experimentation and a mesoscale model, we identify a shift from conventional high state-of-charge (SOC) type plating to high overpotential (OP) type plating as electrode thickness increases. Further, these two plating modes have distinct morphologies, identified by optical microscopy and electrochemical signatures. We demonstrate that under operating conditions where these plating modes converge, a high propensity of plating exists, revealing the importance of predicting and avoiding this overlap for a given electrode pairing. Further, we identify that thicker electrodes, beyond a capacity of 3 mAh/cm 2 or thickness >75 μm, are prone to high OP, limiting negative electrode (NE) utilization and preventing cross-sectional oversizing the NE from mitigating plating. Here, it simply contributes to added mass and volume. The experimental thermal gradient and mesoscale model either combined or independently provide techniques capable of probing performance and safety implications of mild changes to electrode design features.

25 ENERGY STORAGE↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AGR-2 Loose Particle Heating Tests in the Furnace for Irradiated TRISO Testing

A furnace system was developed to thermally expose individual tristructural-isotropic (TRISO) coated particles to expand upon established postirradiation examination (PIE) safety testing that is used to explore particle failures and fission product release from compacts. Two systems were installed in the Irradiated Fuels Examination Facility (IFEL) at Oak Ridge National Laboratory (ORNL). The targeted design was intended to be simple and flexible to allow a range in conditions to be explored. Initial inert atmosphere testing indicated the presence of particle failures, so modifications to the testing approach were implemented to improve the furnace operation. Ultimately, burnback particles were analyzed to provide a direct measurement of fission product release, thus avoiding the complications from integral release that were observed during whole compact testing. Particles were exposed to temperatures ranging 1,150–1,300°C for up to 1,500 h and 1,600°C up to 500 h. No indication of uniform release of fission products such as 106 Ru, 125 Sb, or 154 Eu was observed, however, indication of particle dependent 154 Eu release was suggested for select particles. Exploration of 110m Ag release was limited to 1,150°C and 1,300°C up to 500 h. The analysis indicated that there was nonuniform release of 110m Ag and supports a possible bimodal temperature dependence on silver release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Traditional Registrational Trial End Points: Development and Application of a Desirability of Outcome Ranking End Point for Complicated Urinary Tract Infection Clinical Trials

Abstract Background Traditional end points used in registrational randomized, controlled trials (RCTs) often do not allow for complete interpretation of the full range of potential clinical outcomes. Desirability of outcome ranking (DOOR) is an approach to the design and analysis of clinical trials that incorporates benefits and risks of novel treatment strategies and provides a global assessment of patient experience. Methods Through a multidisciplinary committee of experts in infectious diseases, clinical trial design, drug regulation, and patient experience, we developed a DOOR end point for infectious disease syndromes and demonstrated how this could be applied to 3 registrational drug trials (ZEUS, APEKS-cUTI, and DORI-05) for complicated urinary tract infections (cUTIs). ZEUS compared fosfomycin to piperacillin/tazobactam, APEKS-cUTI compared cefiderocol to imipenem, and DORI-05 compared doripenem to levofloxacin. Using DOOR, we estimated the probability of a more desirable outcome with each investigational antibacterial drug. Results In each RCT, the DOOR distribution was similar and the probability that a patient in the investigational arm would have a more desirable outcome than a patient in the control arm had a 95% confidence interval containing 50%, indicating no significant difference between treatment arms. DOOR facilitated improved understanding of potential trade-offs between clinical efficacy and safety. Partial credit and subgroup analyses also highlight unique attributes of DOOR. Conclusions DOOR can effectively be used in registrational cUTI trials. The DOOR end point presented here can be adapted for other infectious disease syndromes and prospectively incorporated into future clinical trials.

Immunology↗

A Software/Hardware Framework for Efficient and Safe Emergency Response in Post-Crash Scenarios of Battery Electric Vehicles

The adoption rate of battery electric vehicles (EVs) is rapidly increasing. Electric vehicles differ significantly from conventional internal combustion engine vehicles and vary widely across different manufacturers. Emergency responders (ERs) and recovery personnel may have less experience with EVs and lack timely access to critical information such as the extent of the stranded energy present, high-voltage safety hazards, and post-crash handling procedures in a user-friendly manner. This paper presents a software/hardware interactive tool named Electric Vehicle Information for Incident Response Solutions (EVIRS) to aid in the quick access to emergency response and recovery information. The current prototype of EVIRS identifies EVs using the VIN or Make, Model, and Year, and offers several useful features for ERs and recovery personnel. These features include integration and easy access to emergency response procedures tailored to an identified EV, vehicle structural schematics, the quick identification of battery pack specifications, and more. For EVs that are not severely damaged, EVIRS can perform calculations to estimate stranded energy in the EV’s battery and discharge time for various power loads using either EV dashboard information or operational data accessed through the CAN interface. Knowledge of this information may be helpful in the post-crash handling, management, and storage of an EV. The functionality and accuracy of EVIRS were demonstrated through laboratory tests using a 2021 Ford Mach-E and associated data acquisition system. The results indicated that when the remaining driving range was used as an input, EVIRS was able to estimate the pack voltage with an error of less than 3 V. Conversely, when pack voltage was used as an input, the estimated state of charge (SOC) error was less than 5% within the range of 30–90% SOC. Additionally, other features, such as retrieving emergency response guides for identified EVs and accessing lessons learned from archived incidents, have been successfully demonstrated through EVIRS for quick access. EVIRS can be a valuable tool for emergency responders and recovery personnel, both in action and during offline training, by providing crucial information related to assessing EV/battery safety risks, appropriate handling, de-energizing, transport, and storage in an integrated and user-friendly manner.

25 ENERGY STORAGE↗

Code validation of SAM using natural-circulation experimental data from the compact integral effects test (CIET) facility

The primary objective of this study is to validate the system analysis code, SAM, using experimental data from the Compact Integral Effects Test (CIET) experimental loop. SAM is a modern system analysis code being developed at Argonne National Laboratory for safety analysis of designs for advanced non-light water reactors (non-LWRs), such as sodium-cooled fast reactors, high-temperature gas-cooled reactors, and fluoride salt-cooled high-temperature reactors (FHRs). To support SAM code development for the wide range of non-LWR applications, it is of paramount importance to validate the code against experiments highly relevant to these reactor concepts. Additionally, the CIET facility, which was designed to reproduce the thermal-hydraulics response of FHRs under both forced- and natural-circulation conditions, has been identified and selected as one of the benchmark test facilities for SAM code validation. In this study, two sets of available CIET tests were selected for SAM code validation purposes, namely, power step change transient tests and steady-state natural-circulation tests. For all selected tests, SAM-predicted results show very good agreement with experimental data. The successful validation of SAM against these selected CIET experiments demonstrates that the computer code is well suited for thermal-hydraulics analysis of FHR designs.

42 ENGINEERING↗

Non-Ionizing Millimeter Waves Non-Thermal Radiation of Saccharomyces cerevisiae—Insights and Interactions

Non-ionizing millimeter-waves (MMW) interact with cells in a variety of ways. Here the inhibited cell division effect was investigated using 85–105 GHz MMW irradiation within the International Commission on Non-Ionizing Radiation Protection (ICNIRP) non-thermal 20 mW/cm 2 safety standards. Irradiation using a power density of about 1.0 mW/cm 2 SAR over 5–6 h on 50 cells/μL samples of Saccharomyces cerevisiae model organism resulted in 62% growth rate reduction compared to the control (sham). The effect was specific for 85–105 GHz range and was energy- and cell density-dependent. Irradiation of wild type and Δrad52 (DNA damage repair gene) deleted cells presented no differences of colony growth profiles indicating non-thermal MMW treatment does not cause permanent genetic alterations. Dose versus response relations studied using a standard horn antenna (~1.0 mW/cm 2 ) and compared to that of a compact waveguide (17.17 mW/cm 2 ) for increased power delivery resulted in complete termination of cell division via non-thermal processes supported by temperature rise measurements. We have shown that non-thermal MMW radiation has potential for future use in treatment of yeast related diseases and other targeted biomedical outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

Data Testing with Zero Power Reactor (ZPR), Zero Power Physics Reactor (ZPPR), and New Thermal Epithermal eXperiments (TEX) Plutonium Benchmarks [Slides]

This presentation states that new TSLs in ENDF/B-VIII.0 will reduce the overprediction of the library for the most moderated cases. The differences between VII.1 and VIII.0 are driven by the 239 Pu changes and are consistently higher for all configurations. The VIII.0 239 Pu thermal cross sections were specifically adjusted lower to better predict plutonium thermal solutions criticality benchmarks, yet they overpredict the TEX thermal configurations, moderated by PE. Other, smaller differences have been seen for 240 Pu and 56 Fe. PMM-002 has shown utility in testing cross sections over a wide range of neutron energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comprehensive framework for data-driven model form discovery of the closure laws in thermal-hydraulics codes

The two-phase two-fluid model is a basis of many thermal-hydraulics codes used in design, licensing, and safety considerations of nuclear power plants. Thermal-hydraulics codes rely on the closure laws to close the system of conservation equations and describe the interactions between phases. These laws, derived from years of experimental investigations, are semi-empirical correlations that lack generality and have a limited range of applicability. Increase of computational power, availability of new experiments, and development of high-fidelity simulations has increased the number of validation data. The discrepancies between the code predictions and the validation data are a great source of knowledge. Missing physics that are not included in the model but are important for the considered phenomena can be discovered by propagating the information from the experimental results through the model. Furthermore, physics-discovered data-driven model form (P3DM) methodology integrates available integral effect tests and separate effects tests to determine the necessary corrections to the model form of the closure laws. In contrast to existing calibration techniques, the methodology modifies the functional form of the closure laws. Based on the functional form of the correction, the missing physics that were not included in the original model can be discovered. The methodology provides the alternative to the machine learning approach, in which the model is discovered in the form of the intractable black-box relation. In this work, the methodology was applied to the CTF subchannel code to improve the prediction of the two-phase flow phenomena.

42 ENGINEERING↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulations of Water Flow in Relation to a Steady Criticality in an Unsaturated Alluvial Repository

Oak Ridge National Laboratory (ORNL) is examining the conditions under which a criticality event could be ruled out for large packages placed in an unsaturated alluvial repository. This work specifically examines the water level in a stylized waste package that is assumed (1) to fail on the top, and (2) to empty as water is driven away—not by boiling—but by fluid flow phenomena driven by thermal gradients. This analysis uses the PFLOTRAN code package. Specifically, this year’s work includes examination of the heat rate at which water is driven away for various percolation rates using the same assumptions listed in the 2022 annual report. The STANDARDS (formerly UNF-ST&DARDS) package has predicted dual-purpose canister (DPC) neutron multiplication factors (k-effectives) ranging above 1.1 (unitless) with failed components. The DPC designs were not created with the intent to use for disposal purposes. Emplacing such packages may be worth consideration if it can be shown that criticality is either extremely unlikely or of very low consequence to the repository’s safety case. This work aims to help establish hydrologic boundary conditions for a highly hypothetical, highly stylized subsurface criticality event. The approach to critical is assumed to be slow, producing steady heating rates under a few kilowatts. For a DPC containing capillary media, the simulated power required for dry-out was proportional to the percolation rate but was unaffected by the size of a large breech on top of the DPC. Results for single cases with no capillary media in the DPC suggest that higher infiltration rates may be required in those cases to cause flooding. Bounding mechanisms and assumptions must be identified and characterized further by performing additional perturbations to various input parameters to demonstrate robustness of the results. This might be accomplished by examining responses to power pulses to determine the system transfer function required to enable a reduced order feedback model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring the Potential of Second-Life Batteries for Mobile Charging Infrastructure: A Review

This review paper investigates the potential applications of second-life batteries (SLBs) specifically for mobile charging stations. As the adoption of electric vehicles (EVs) continues to rise, the need for accessible and efficient charging infrastructure becomes increasingly critical to address range anxiety of EV owners. The repurposing of SLBs presents a promising solution to address this need, offering cost-effective and sustainable alternatives to traditional stationary charging infrastructure. This paper examines key technical considerations, including battery chemistry, state of health assessment, heterogeneity and battery management system design, and safety protocols tailored to SLBs. The paper also highlights economic and environmental implications of utilizing SLBs in mobile charging applications, encompassing techno-economic analysis techniques and sustainability metrics. Through an exploration of challenges, opportunities, and emerging trends, this review aims to provide valuable insights to stakeholders involved in the development and deployment of SLBs in mobile charging infrastructure.

Gautam, Mukesh (ORCID:0000000305715825)↗

A New 1D Model for Thermal Mixing and Stratification in Advanced Reactor Transients

Thermal mixing and stratification in large pools and enclosures play a critical role in the safety and performance of pool-type nuclear reactors, particularly during transient scenarios involving significant temperature differences between incoming and bulk coolant. Accurate modeling of these phenomena is essential for predicting system behavior and supporting passive safety features such as natural circulation. Here, this paper presents a new 1D model for thermal mixing and stratification, developed and implemented in the SAM code. The model represents a large pool as 1D coolant jet channels and zero-dimensional bulk pool volumes, enabling the simulation of a wide range of flow configurations, including hot and cold jet interactions, stratified layers, and the influence of complex geometries such as ceilings, free surfaces, and internal obstacles. Heat exchange between jet and pool regions is governed by closure relations calibrated against 3D computational fluid dynamics (CFD) simulations. The model improves upon earlier approaches by incorporating time-dependent jet characteristics and capturing the associated delay effects more accurately. Code-to-code comparisons and validation against experimental data from the Thermal Stratification Test Facility demonstrate the model’s accuracy and flexibility. This work offers two key contributions: (1) an efficient and robust method for simulating thermal mixing and stratification at the system level, eliminating the need for external coupling between system analysis codes and CFD, and (2) a significant enhancement of SAM’s capabilities to analyze thermal stratification phenomena in advanced reactor systems.

SAM↗

The Sensor Dilemma in Intelligent Transportation Systems

Intelligent Transportation Systems (ITS) are at the forefront in advancing the way we interact and perceive with the transportation network. This revolution is fueled by the significant advancement in sensor perception technologies such as Radar, LiDAR and Video Imaging which are the most popular modalities for ITS. Real-time perception data from these sensors allows intelligent infrastructure side decision making to improve the energy, efficiency and safety at traffic intersections. As traffic departments across the United States are transitioning from traditional loop detectors / emulators and embracing newer technologies, they are often left with a dilemma in choosing a sensor technology for infrastructure-based perception which is reliable, inexpensive, easy to setup and has robust performance in varying weather conditions. However, choosing a sensor which checks all boxes is not straightforward as every sensor type has unique benefits and drawbacks. Radar is excellent at detecting long range vehicles and weather resistance but lacks high resolution. LiDAR is expensive and weather-sensitive, while cameras provide rich visual data at a low cost but are constrained by lighting and visibility. This study examines Radar, LiDAR and camera sensors capabilities to ascertain whether any of these qualifies as the "best" sensor for ITS perception. Through this evaluation, we hope to draw attention to the necessity of National Renewable Energy Laboratory's (NREL) Infrastructure Perception and Control (IPC) framework which presents a multi-sensor track data fusion engine to assimilate multiple data streams in order to provide robust and reliable perception. While no single sensor can meet all the demands of ITS, a hybrid approach combining multiple sensor modalities like Radar, LiDAR and cameras, offers the most robust solution for enhancing the safety and efficiency in intelligent transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗