A reference atmosphere for patrick afb, florida, annual /1963 revision/
Reference atmosphere for cape kennedy based on statistical parameters of pressure-height, temperature, and relative humidity at constant pressure levels
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Reference atmosphere for cape kennedy based on statistical parameters of pressure-height, temperature, and relative humidity at constant pressure levels
Troposphere relative humidity and cloud surface temperature determination by radiation data from TIROS III satellite
Effect of environmental temperatures and relative humidities on curing times of polyurethane and polysulfide potting compounds
Satellite radiation data application to synoptic weather analysis including cloud pattern mapping, tropospheric relative humidity and vertical cloud structure inference
Decontamination of spacecraft components with ethylene oxide as function of parameters of gas concentration, time, temperature, and relative humidity
Adsorbed formaldehyde levels from vaporized paraformaldehyde on various surfaces as function of relative humidity and chemical concentration
The experiments carried out to determine the effects of temperature and relative humidity on the survival rate of Bacillus subtillis var. niger spores are reported. The experiments were conducted in environmental chambers at temperatures of 75 and 90 C. Data are also included on the survival characteristics of the spores suspended in sucrose solutions at 90 C with water activities of 0.99, 0.9, and 0.85
A set of conditions in which 90 C was a more lethal temperature than 125 C for the destruction of Bacillus subtilis var. niger was identified as a function of relative humidity, with maximum effectiveness at 100% R.H. A systematic study of the influence of head-space moisture and temperature on the destruction of B. subtilis var. niger is reported.
Data showing that 90 C was a more effective temperature than 125 C for the destruction of Bacillus subtilis var. niger when the head-space moisture was fixed at 474 micrograms H2O/ml have been confirmed and are summarized. The influence of head-space moisture at 90 C was investigated and it was observed that as the head-space moisture was increased 474 micrograms H2O/ml, there was a corresponding increase in lethality of the system. This moisture level corresponded to 100% relative humidity at 90 C, and additional water in the cans should have had no effect. A profound descrease was observed in the destruction of the organisms when additional water was added. The discontinuity observed in these data is troublesome and must be resolved as the first step in an orderly exploration of low temperature inactivation of B. subtilis var. niger.
The mechanical properties of bare ZM-21 magnesium alloy flat tensile specimens were determined for test temperatures of +400 F, +300 F, +200 F, +80 F, 0 F, -100 F, -200 F, and -320 F. The ultimate tensile and yield strengths of the material increased with decreasing temperature with a corresponding reduction in elongation values. Stress corrosion tests performed under: (1) MSFC atmospheric conditions; (2) 95% relative humidity; and (3) submerged in 100 ppm chloride solution for 8 weeks indicated that the alloy is not susceptible to stress corrosion. The corrosion tests indicated that the material is susceptible to attack by crevice corrosion in high humidity and chemical type attack by chloride solution. Atmospheric conditions at MSFC did not produce any adverse effects on the material, probably due to the rapid formation of a protective oxide coating. In both the mechanical properties and the stress corrosion evaluations the test specimens which were cut transverse to the rolling direction had superior properties when compared to the longitudinal properties.
The development of an inorganic separator material for use in construction of 40 ampere-hour silver zinc cells is discussed. Acceptance tests were conducted to determine real quality, physical defects and ampere-hour capacity. All acceptance tests were performed at an ambient temperature of 23 to 27 C at existing relative humidity and atmospheric pressure. Of the 63 cells tested, only one failed to meet the equipment specifications.
Constant force creep measurements were made at three stress levels on samples of an ammonium perchlorate filled butadiene-acrylic acid copolymer in vacuum and in the atmosphere (air, 50% relative humidity) at a temperature of 28 C. The creep compliance of the samples decreased as much as 50% after 14 days of vacuum exposure. Shift factors were developed which, when applied to the atmospheric compliance measurements, predicted the behavior in vacuum. The experimental results led to the following conclusions: (1) shift factors can be applied to predict compliance behavior in vacuum from measurements in air, and (2) the shift factors are independent of stress but increase in magnitude with increasing vacuum exposure.
Research is reported on the effects of increasing the CO2, aerosols, and water content of the atmosphere on the surface temperature and climatology. An atmospheric model is described with the incoming solar radiation for a planetary albedo of 33 percent, surface temperature of 288 K, relative humidity of 75 percent, cloud cover of 48 percent, CO2 of 0.3 parts per thousand, and aerosol density of two million per square centimeter. The results show that if the CO2 increases by a factor of 1000 or more, the total pressure of the atmosphere increases, and the earth may become as hot as Venus. It is also shown that as the amount of dust particles in the atmosphere increases, the solar radiation decreases, and the surface temperature lowers.
A study of shelf stability in intermediate moisture foods was made. Major efforts were made to control lipid oxidation and nonenzymatic browning. In order to determine means of preventing these reactions, model systems were developed having the same water activity content relationship of intermediate moisture foods. Models were based on a cellulose-lipid and protein-lipid system with glycerol added as the humectant. Experiments with both systems indicate that lipid oxidation is promoted significantly in the intermediate moisture range. The effect appeared to be related to increased mobility of either reactants or catalysts, since when the amount of water in the system reached a level where capillary condensation occurred and thus free water was present, the rates of oxidation increased. With added glycerol, which is water soluble and thus increases the amount of mobile phase, the increase in oxidation rate occurs at a lower relative humidity. The rates of oxidation were maximized at 61% RH and decreased again at 75% RH probably due to dilution. No significant non-enzymatic browning occurred in the protein-lipid systems. Prevention of oxidation by the use of metal chelating agents was enhanced in the cellulose system, whereas, with protein present, the lipid soluble chain terminating antioxidants (such as BHA) worked equally as well. Preliminary studies of foods adjusted to the intermediate moisture range bear out the results of oxidation in model systems. It can be concluded that for most fat containing intermediate moisture foods, rancidity will be the reaction most limiting stability.
Fertile chicken eggs were incubated in an altitude chamber in a near 100% O2 atmosphere at 225 torr. Both N2 and CO2 were kept under 0.5%. Temperature was a standard 37.5 C but a high relative humidity of 90% was required to prevent dehydration. In ten trials involving 382 eggs, hatchability averaged 21% of controls and weight of chicks was 11% less than controls, but embryo mortality was distributed similarly. Low pressure per se and small differences in O2 tension may have affected the results, but similarities to incubation in 21% O2-79% He call attention to absence of nitrogen as a possible explanation.
Internal reflection spectroscopy may be used to determine presence of water in thin film pores. Presence of water in such pores is function of relative humidity and pore size. Thus, one can determine pore size by controlling humidity. Fluids with surface tension different from that of water can be used to detect pores.
A description is given of conditions of atmospheric temperature and relative humidity under which hydrochloric acid aerosol is expected upon interaction of the proposed space shuttle rocket exhaust products with the atmosphere.
This study examines the changes in resistivity of rock samples as induced by atmospheric moisture. Experiments were performed on samples of hematitic sandstone, pyrite, and galena. The sandstone underwent a change in resistivity of four orders of magnitude when it was measured in a vacuum of 500 ntorr and in air of 37% relative humidity. Pyrite and galena showed no variations in resistivity when they were measured under the same conditions. These results, plus others obtained elsewhere, indicate that rocks of the resistive type are affected in their electrical properties by atmospheric moisture, whereas rocks of the conductive type are not. The experimental evidence obtained is difficult to reconcile with a model of aqueous electrolytic conduction on the sample surface. It is instead suggested that adsorbed water molecules alter the surface resistivity in a manner similar to that observed in semiconductors and insulators.