At least 325 records · Page 18

Development of Site-Specific Soil Design Basis Earthquake (DBE) Parameters for the Integrated Waste Treatment Unit (IWTU)

Horizontal and vertical PC 3 (2,500 yr) Soil Design Basis Earthquake (DBE) 5% damped spectra, corresponding time histories, and strain-compatible soil properties were developed for the Integrated Waste Treatment Unit (IWTU). The IWTU is located at the Idaho Nuclear Technology and Engineering Center (INTEC) at the Idaho National Laboratory (INL). Mean and 84th percentile horizontal DBE spectra derived from site-specific site response analyses were evaluated for the IWTU. The horizontal and vertical PC 3 (2,500 yr) Soil DBE 5% damped spectra at the 84th percentile were selected for Soil Structure Interaction (SSI) analyses at IWTU. The site response analyses were performed consistent with applicable Department of Energy (DOE) Standards, recommended guidance of the Nuclear Regulatory Commission (NRC), American Society of Civil Engineers (ASCE) Standards, and recommendations of the Blue Ribbon Panel (BRP) and Defense Nuclear Facilities Safety Board (DNFSB).

58 GEOSCIENCES↗

TES Level 1 Algorithms: Interferogram Processing, Geolocation, Radiometric, and Spectral Calibration

The Tropospheric Emission Spectrometer (TES) on the Earth Observing System (EOS) Aura satellite measures the infrared radiance emitted by the Earth's surface and atmosphere using Fourier transform spectrometry. The measured interferograms are converted into geolocated, calibrated radiance spectra by the L1 (Level 1) processing, and are the inputs to L2 (Level 2) retrievals of atmospheric parameters, such as vertical profiles of trace gas abundance. We describe the algorithmic components of TES Level 1 processing, giving examples of the intermediate results and diagnostics that are necessary for creating TES L1 products. An assessment of noise-equivalent spectral radiance levels and current systematic errors is provided. As an initial validation of our spectral radiances, TES data are compared to the Atmospheric Infrared Sounder (AIRS) (on EOS Aqua), after accounting for spectral resolution differences by applying the AIRS spectral response function to the TES spectra. For the TES L1 nadir data products currently available, the agreement with AIRS is 1 K or better.

infrared remote sensing↗

GADRAS Detector Response Function.

The Gamma Detector Response and Analysis Software (GADRAS) applies a Detector Response Function (DRF) to compute the output of gamma-ray and neutron detectors when they are exposed to radiation sources. The DRF is fundamental to the ability to perform forward calculations (i.e., computation of the response of a detector to a known source), as well as the ability to analyze spectra to deduce the types and quantities of radioactive material to which the detectors are exposed. This document describes how gamma-ray spectra are computed and the significance of response function parameters that define characteristics of particular detectors.

Mitchell, Dean J.↗

FIER: Software for analytical modeling of delayed gamma-ray spectra

We report a new software package, the Fission Induced Electromagnetic Response (FIER) code, has been developed to analytically predict delayed γ-ray spectra following fission. FIER uses evaluated nuclear data and solutions to the Bateman equations to calculate the time-dependent populations of fission products and their decay daughters resulting from irradiation of a fissionable isotope. These populations are then used in the calculation of γ-ray emission rates to obtain the corresponding delayed γ-ray spectra. FIER output was compared to experimental data obtained by irradiation of a 235 U sample in the Godiva critical assembly. This investigation illuminated discrepancies in the input nuclear data libraries, showcasing the usefulness of FIER as a tool to address nuclear data deficiencies through comparison with experimental data. Finally, FIER provides traceability between γ-ray emissions and their contributing nuclear species, decay chains, and parent fission fragments, yielding a new capability for the nuclear science community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A COMPARISON OF GADRAS SIMULATED AND MEASURED GAMMA RAY SPECTRA

Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-46: Feasibility of Cerenkov Emission for Absorption Spectroscopy

Purpose: Cerenkov emission (CE) is a promising tool for online tumor microenvironment interrogation and targeting during radiotherapy. In this work, we utilize CE generated during radiotherapy as a broadband excitation source for real-time absorption spectroscopy. We demonstrate the feasibility of CE spectroscopy using a controlled experiment of materials with known emission/absorption properties. Methods: A water tank is irradiated with 20 MeV electron beam to induce Cerenkov emission. Food coloring dyes (Yellow #5, Red #40, and Blue #1), which have known emission/absorption properties were added to the water tank with increasing concentration (1 drop (0.05 mL), 2 drops, and 4 drops from a dispenser bottle). The signal is collected using a condensing lens which is coupled into a 20m optical fiber that is fed into a spectrometer that measures the emitted spectra. The resulting spectra from water/food coloring dye solutions were normalized by the reference spectrum, which is the Cerenkov spectrum of pure water, correcting for both the nonlinearity of the broadband Cerenkov emission spectrum as well as the non-uniform spectral response of the spectrometer. The emitted spectra were then converted into absorbance and their characteristics were analyzed. Results: The food coloring dye had a drastic change on the Cerenkov emission, shifting its wavelength according to its visible color. The collected spectra showed various absorbance peaks which agrees with tabulated peak positions of the dyes added within 0.3% for yellow, 1.7% for red, and 0.16% for blue. The CE peak heights proportionally increased as the dye concentration is increased. Conclusion: This work shows the potential for real-time functional spectroscopy using Cerenkov emission during radiotherapy. It was demonstrated that molecule identification as well as relative concentration can be extracted from the Cerenkov emission color shift.

60 APPLIED LIFE SCIENCES↗

Balloon-borne measurements of the SN1987A hard x ray continuum

SN1987A hard x ray continuum spectra obtained on 29 Oct. 1987, 9-10 Apr. 1988, and 11 Nov. 1988, from balloon flight measurements are presented. The spectra, spanning the energy range from 25 keV to 300 keV, were analyzed using a detector response matrix inversion technique that converts the spectra from counts/sec-sq cm-kev to photons/sec-sq cm-kev allowing direct comparison with theoretical models. The results indicate that the bulk of the Co-56 is mixed moderately through the inner regions of the SN envelope but they do not preclude the mixing of a small amount of the Co-56 further out into the envelope necessary to account for the observed Co-56 line fluxes. The effect of the ratio of Co-57 to Co-56 on the 11 Nov. 1988, continuum spectrum is discussed.

Pendleton, Geoffrey N.↗

Evaluation of metal artifacts in MVCT systems using a model based correction method

Purpose: To evaluate the performance of a model based image reconstruction method in reducing metal artifacts in the megavoltage computed tomography (MVCT) images of a phantom representing bilateral hip prostheses and to compare with the filtered-backprojection (FBP) technique. Methods: An iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with an additional model for the pair/triplet production process and the energy dependent response of the detectors. The beam spectra for an in-house bench-top and TomoTherapy Trade-Mark-Sign MVCTs are modeled for use in IMPACT. The empirical energy dependent response of detectors is calculated using a constrained optimization technique that predicts the measured attenuation of the beam by various thicknesses (0-24 cm) of solid water slabs. A cylindrical (19.1 cm diameter) plexiglass phantom containing various cylindrical inserts of relative electron densities 0.295-1.695 positioned between two steel rods (2.7 cm diameter) is scanned in the bench-top MVCT that utilizes the bremsstrahlung radiation from a 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C and in the imaging beam of the TomoTherapy Trade-Mark-Sign MVCT. The FBP technique in bench-top MVCT reconstructs images from raw signal normalized to air scan and corrected for beam hardening using a uniform plexiglass cylinder (20 cm diameter). The IMPACT starts with a FBP reconstructed seed image and reconstructs the final image in 150 iterations. Results: In both MVCTs, FBP produces visible dark shading in the image connecting the steel rods. In the IMPACT reconstructed images this shading is nearly removed and the uniform background is restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding values in the absence of the steel inserts. In the FBP images of the bench-top MVCT, the shading causes 4%-9.5% underestimation of electron density at the central inserts with an average of (6.3 {+-} 1.8)% for the range of electron densities studied. In the uniform plexiglass background, the shadow creates 0.8%-4.7% underestimation of electron density with an average of (2.9 {+-} 1.2)%. In the corresponding IMPACT images, the underestimation in the shaded plexiglass background is 0.3%-1.8% with an average of (0.9 {+-} 0.5)% and 1.4%-6.8% with an average of (2.8 {+-} 2.7)% in the central insert region. In the FBP images of the TomoTherapy Trade-Mark-Sign MVCT, this shading creates 2.6%-6.7% underestimation of electron density with an average of (3.7 {+-} 1.4)% at the central inserts and 5.9%-7.2% underestimation in the background with an average of (6.4 {+-} 0.5)%. In the IMPACT images, the uniform background between the steel rods is restored with 0.3%-1.0% underestimation of electron density with an average of (0.7 {+-} 0.3)%. The corresponding underestimation at the central inserts of the IMPACT images is -0.4%-0.1% with an average of (-0.1 {+-} 0.2)%. Conclusions: The shading metal artifact has been nearly removed in MVCT images using the IMPACT algorithm with the accurate geometry of the system, proper modeling of energy dependent response of detectors, and all relevant photon interaction processes. This results less than 1% difference in electron density in the background plexiglass and less than 3% averaged over the range of electron densities investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Franck-Condon factors perturbed by damped harmonic oscillators: Solvent enhanced X {sup 1}A{sub g} ↔ A{sup 1}B{sub 1u} absorption and fluorescence spectra of perylene

Damped harmonic oscillators are utilized to calculate Franck-Condon factors within displaced harmonic oscillator approximation. This is practically done by scaling unperturbed Hessian matrix that represents local modes of force constants for molecule in gaseous phase, and then by diagonalizing perturbed Hessian matrix it results in direct modification of Huang–Rhys factors which represent normal modes of solute molecule perturbed by solvent environment. Scaling parameters are empirically introduced for simulating absorption and fluorescence spectra of an isolated solute molecule in solution. The present method is especially useful for simulating vibronic spectra of polycyclic aromatic hydrocarbon molecules in which hydrogen atom vibrations in solution can be scaled equally, namely the same scaling factor being applied to all hydrogen atoms in polycyclic aromatic hydrocarbons. The present method is demonstrated in simulating solvent enhanced X {sup 1}A{sub g} ↔ A{sup 1}B{sub 1u} absorption and fluorescence spectra of perylene (medium-sized polycyclic aromatic hydrocarbon) in benzene solution. It is found that one of six active normal modes v{sub 10} is actually responsible to the solvent enhancement of spectra observed in experiment. Simulations from all functionals (TD) B3LYP, (TD) B3LYP35, (TD) B3LYP50, and (TD) B3LYP100 draw the same conclusion. Hence, the present method is able to adequately reproduce experimental absorption and fluorescence spectra in both gas and solution phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploration of ion temperature profile measurements at JET using the upgraded neutron profile monitor

The neutron profile monitor (NPM), routinely used at the Joint European Torus for neutron emissivity profile measurements, consists of two fan-shaped arrays of collimators and each line of sight (LOS) is equipped with a NE213 liquid organic scintillator for simultaneous measurements of the 2.5 MeV and 14 MeV neutrons. A digital system developed in ENEA has replaced the analog acquisition electronics and now enables the NPM to perform spatially resolved neutron spectrometry by providing neutron pulse height spectra (PHS) for each LOS. However, the NPM was not originally designed as a spectrometer and, therefore, lacks several key features, such as detailed measurements of the detector response functions and the presence of detector stability monitors. We present a proof of principle of ion temperature profile measurements derived from the NPM PHS in high plasma current discharges using simulated detector response functions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ellipsometric characterization and density-functional theory analysis of anisotropic optical properties of single-crystal α-SnS

We report on the anisotropic optical properties of single-crystal tin monosulfide (SnS). The components ε{sub a}, ε{sub b}, and ε{sub c} of the pseudodielectric-function tensor (ε)=(ε₁)+i(ε₂) spectra are taken from 0.73 to 6.45 eV by spectroscopic ellipsometry. The measured (ε) spectra are in a good agreement with the results of the calculated dielectric response from hybrid density functional theory. The (ε) spectra show the direct band-gap onset and a total of eight above-band-gap optical structures that are associated with the interband-transition critical points (CPs). We obtain accurate CP energies by fitting analytic CP expressions to second-energy-derivatives of the (ε) data. Their probable electronic origins and implications for photovoltaic applications are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Balloon-borne measurements of the SN 1987A hard X-ray continuum

SN 1987A hard X-ray continuum spectra obtained on 1987 October 29, 1988 April 9-10, and 1988 November 11 from balloon-flight measurments are presented. The spectra, spanning the energy range from 25 keV to 300 keV, have been analyzed using a detector response matrix inversion technique that converts the spectra form counts/s/sq cm keV to photons/s/sq cm keV allowing direct comparison with theoretical models. The results indicate that the bulk of the (56)Co is mixed moderately through the inner regions of the supernova envelope but they do not preclude the mixing of a small amount of the (56)Co farther out into the envelope necessary to account for the observed (56)Co line fluxes. The effect of the ratio (57)Co to (56)Co on the 1988 November 11 continuum spectrum is discussed.

Pendleton, Geoffrey N.↗

Graphitic carbon nitride/Cu{sub 2}O heterojunctions: Preparation, characterization, and enhanced photocatalytic activity under visible light

As a metal-free semiconductor material, graphitic carbon nitride (C{sub 3}N{sub 4}), the high recombination rate of photogenerated charges and insufficient sunlight absorption limit its solar-based photocatalytic activity. Here, we reported the heterojunctions of C{sub 3}N{sub 4}–Cu{sub 2}O with a p–n junction structure, which was synthesized by a hydrothermal method. The HR-TEM result revealed an intimate interface between C{sub 3}N{sub 4} and Cu{sub 2}O in the heterojunction, and UV–vis diffuse reflection spectra showed their extended spectral response in the visible region compared with pure C{sub 3}N{sub 4}. These excellent structural and spectral properties, as well as p–n junction structures, endowed the C{sub 3}N{sub 4}–Cu{sub 2}O heterojunctions with enhanced photocatalytic activities. The possible photocatalytic mechanism that photogenerated holes as the mainly oxidant species in photocatalysis was proposed base on the trapping experiments. - Highlights: • A hydrothermal method was used to prepare C3N{sub 4}–Cu{sub 2}O heterojunction. • The resulting heterojunction possesses broader absorption in the visible region. • The material owns a high visible light activity and stability for dye degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural and optical analysis of Fe doped NiO nanoparticles synthesized by chemical precipitation route

Highlights: • The Fe doped NiO nanoparticles were synthesized by chemical precipitation route. • XRD analysis reveals cubic rock-salt fcc structure of the synthesized nanoparticles. • The Ni-O and Fe-O bonding were confirmed through FTIR spectroscopy. • Existence of nickel or interstitial oxygen vacancies indicates p-type nature of nanoparticles. - Abstract: The Ni{sub 1-x}Fe{sub x}O (x = 0.00, 0.02, 0.04 and 0.06) nanoparticles are synthesized by chemical precipitation route using polyvinyl-pyrrolidone (PVP) and nitrate metal salts. The results of thermogravimetric analysis (TGA) of the synthesized dried hydroxide powders showed that thermal decomposition occurs up to 500 °C so as to form pure Ni{sub 1-x}Fe{sub x}O. Therefore, all synthesized samples were calcined at 500 °C for 4 h and then used for further characterization. Energy dispersive X-ray spectroscopy (EDS) of all the samples showed the presence of Ni, O and Fe without any other impurities. From X-ray diffraction (XRD) and transmission electron microscopy (TEM) we could prove that the samples are polycrystalline in nature and are in single phase. The different vibrational modes in Ni{sub 1-x}Fe{sub x}O (x = 0.00, 0.02, 0.04 and 0.06) nanoparticles were studied by Raman spectroscopy and Fourier transform infrared spectroscopy (FTIR). Further, we analyzed the optical response from ultraviolet-visible spectra and Photoluminescence (PL) spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bright Silicon Nanocrystals from a Liquid Precursor: Quasi-Direct Recombination with High Quantum Yield

Silicon nanocrystals (SiNCs) with bright bandgap photoluminescence (PL) are of current interest for a range of potential applications, from solar windows to biomedical contrast agents. Here, we use the liquid precursor cyclohexasilane (Si 6 H 12 ) for the plasma synthesis of colloidal SiNCs with exemplary core emission. Here, through size separation executed in an oxygen-shielded environment, we achieve PL quantum yields (QYs) approaching 70% while exposing intrinsic constraints on efficient core emission from smaller SiNCs. Time-resolved PL spectra of these fractions in response to femtosecond pulsed excitation reveal a zero-phonon radiative channel that anticorrelates with QY, which we model using advanced computational methods applied to a 2 nm SiNC. Our results offer additional insight into the photophysical interplay of the nanocrystal surface, quasi-direct recombination, and efficient SiNC core PL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chromium-Removal Processes during Groundwater Remediation by a Zerovalent Iron Permeable Reactive Barrier

Solid-phase associations of chromium were examined in core materials collected from a full-scale, zerovalent iron permeable reactive barrier (PRB) at the U.S. Coast Guard Support Center located near Elizabeth City, NC. The PRB was installed in 1996 to treat groundwater contaminated with hexavalent chromium. After eight years of operation, the PRB remains effective at reducing concentrations of Cr from average values >1500 {micro}g L{sup -1} in groundwater hydraulically upgradient of the PRB to values <1 {micro}g L{sup -1} in groundwater within and hydraulically downgradient of the PRB. Chromium removal from groundwater occurs at the leading edge of the PRB and also within the aquifer immediately upgradient of the PRB. These regions also witness the greatest amount of secondary mineral formation due to steep geochemical gradients that result from the corrosion of zerovalent iron. X-ray absorption near-edge structure (XANES) spectroscopy indicated that chromium is predominantly in the trivalent oxidation state, confirming that reductive processes are responsible for Cr sequestration. XANES spectra and microscopy results suggest that Cr is, in part, associated with iron sulfide grains formed as a consequence of microbially mediated sulfate reduction in and around the PRB. Results of this study provide evidence that secondary iron-bearing mineral products may enhance the capacity of zerovalent iron systems to remediate Cr in groundwater, either through redox reactions at the mineral-water interface or by the release of Fe(II) to solution via mineral dissolution and/or metal corrosion.

54 ENVIRONMENTAL SCIENCES↗

Tuning the catalytic CO hydrogenation to straight- and long-chain aldehydes/alcohols and olefins/paraffins

Here, the catalytic CO hydrogenation is one of the most versatile large-scale chemical syntheses leading to variable chemical feedstock. While traditionally mainly methanol and long-chain hydrocarbons are produced by CO hydrogenation, here we show that the same reaction can be tuned to produce long-chain n-aldehydes, 1-alcohols and olefins, as well as n-paraffins over potassium-promoted CoMn catalysts. The sum selectivity of aldehydes and alcohols is usually >50 wt% whereof up to ~97% can be n-aldehydes. While the product slate contains ~60% n-aldehydes at /p CO =0.5, a 65/35% slate of paraffins/alcohols is obtained at a ratio of 9. A linear Anderson–Schulz–Flory behaviour, independent of the /p CO ratio, is found for the sum of C 4+ products. We advocate a synergistic interaction between a Mn 5 O 8 oxide and a bulk Co 2 C phase, promoted by the presence of potassium, to be responsible for the unique product spectra in our studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗