At least 325 records · Page 18

Introduction to the IMPACT Probabilistic Risk and Tradespace Analysis Tool for Medical System Design

Background: Probabilistic risk analysis (PRA) is a method for estimating risk in complex engineered systems that, at a basic level, focuses on what can go wrong and the likelihood and consequences of those occurrences. NASA has used PRA as an integral component of medical system risk estimation and design for spaceflight. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a novel tool to meet these goals for exploration missions. Overview: IMPACT performs hundreds of thousands of Monte Carlo simulations of missions to build aggregate pictures of medical risk. These simulations are based on 120 possible medical conditions (the IMPACT Condition List) selected in a consensus-based process because they are of highest likelihood and/or consequence for exploration spaceflight. The conditions are then tied to clinical capabilities which can be used for management (e.g., inserting an IV) and then to over 600 specific resources needed to deliver a capability (e.g., an angiocath or an ultrasound). Different mission profiles can be simulated with user-specified inputs such as mission duration, destination, number of crew and pre-existing medical conditions, and EVA frequency. While the IMPACT evidence base is designed for exploration environments, these user inputs allow the tool to be used across a broad range of missions. IMPACT’s primary outcome metrics include loss of crew life (LOCL, a measure of in-flight mortality due to medical conditions), need for evacuation (RTDC, return to definitive care), and crew disability (TTL, task time lost based on how medical conditions impact the ability to perform over 1000 specific exploration mission crew tasks). In addition to modeling medical risk, IMPACT also accepts user-specified constraints, such as limitations of mass or volume, and will output a recommended clinical capability set and specific medical resources that meet the mission constraints. Discussion: This abstract will provide an introduction to IMPACT and describe the nature of the underlying medical evidence. It will also detail potential use cases for how this tool can be utilized by NASA or commercial spaceflight providers.

Ben Easter↗

Electric Propulsion Qualification Guidelines and Best Practices for NASA Small Spacecraft Missions

Electric propulsion being developed for CubeSats and other small satellites with the taught expectation that high risk is generally acceptable are resulting in devices that do not meet a minimum expectation of engineering rigor for many missions, including appropriate qualification testing. This paper proffers a preliminary set of recommended guidelines and best practices in dialogue with the smallsat community to strike a better balance between engineering rigor and cost effectiveness for the qualification of EP technologies under consideration for NASA small spacecraft.

Thomas M. Liu↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Flow Analysis on a Limited Volume Chilled Water System

LANL Currently has a limited volume chilled water system for use in a glove box, but the system needs to be updated. Before we start building our new system, a flow analysis is needed to ensure that there are no high flow rates, extreme pressures, or any other hazards involved in the system. In this project the piping system is extremely important to us because it directly affects the overall design of the entire system. The primary components necessary for the chilled water piping system are shown in the design. They include the pipes themselves (perhaps of more than one diameter), the various fitting used to connect the individual pipes to form the desired system, the flow rate control devices (valves), and the pumps that add energy to the fluid. Even the most simple pipe systems are actually quite complex when they are viewed in terms of rigorous analytical considerations. I used an 'exact' analysis and dimensional analysis considerations combined with experimental results for this project. When 'real-world' effects are important (such as viscous effects in pipe flows), it is often difficult or impossible to use only theoretical methods to obtain the desired results. A judicious combination of experimental data with theoretical considerations and dimensional analysis are needed in order to reduce risks to an acceptable level.

42 ENGINEERING↗

Controlling radiological and chemical hazards of uranium in the workplace: Applications of biokinetic modeling and occupational monitoring data

This paper describes methods of interpreting and applying occupational uranium (U) monitoring data to avoid chemical damage to the kidneys and limit radiological risk to an acceptable level. The methods are based on current international radiation protection guidance, current information on the chemical toxicity of U, and best available biokinetic models for U. The methods apply to air monitoring data and bioassay (U in urine and faeces and externally measured U in lungs). Reference primary guidance levels for prevention of chemical effects and limitation of radiation effects are selected on the basis of a review of current scientific data and regulatory principles for setting standards. Generic investigation levels (ILs) and immediate action levels (IALs) are defined in terms of the primary guidance levels. The ILs and IALs are stated in terms of generic levels of radiation dose and concentration of U in the kidneys that are not directly measurable quantities. Models are used to relate the generic levels to measured levels of U in air or bioassay. Methods are prescribed for deriving ILs and IALs of U in air and bioassay for known and unknown solubility levels of airborne U. This paper focuses on interpretation of air monitoring to illustrate the general approach.

bioassay↗

Multiple objective optimization in reliability demonstration test

Reliability demonstration tests are usually performed in product design or validation processes to demonstrate whether a product meets specified requirements on reliability. For binomial demonstration tests, the zero-failure test has been most commonly used due to its simplicity and use of minimum sample size to achieve an acceptable consumer’s risk level. However, this test can often result in unacceptably high risk for producers as well as a low probability of passing the test even when the product has good reliability. This paper explicitly explores the interrelationship between multiple objectives that are commonly of interest when planning a demonstration test and proposes structured decision-making procedures using a Pareto front approach for selecting an optimal test plan based on simultaneously balancing multiple criteria. Different strategies are suggested for scenarios with different user priorities and graphical tools are developed to help quantify the trade-offs between choices and to facilitate informed decision making. As a result, potential impacts of some subjective user inputs on the final decision are studied to offer insights and useful guidance for general applications.

97 MATHEMATICS AND COMPUTING↗

Gaps in the Design Process

The design of offshore wind plants is a relatively new field. The move into U.S. waters will have unique environmental conditions, as well as expectations from the authorities responsible for managing the development. Wind turbines are required to test their assumed design conditions with the site conditions of the plant. There are still some outstanding issues on how we can assure that the design for both the turbine and the foundation are appropriate for the site and will have an acceptable level of risk associated with the particular installation.

17 WIND ENERGY↗

ARAM-W Automated Risk Assessment Methodology for Water and Wastewater

The Automated Risk Assessment Methodology for Water and Wastewater Utilities, ARAM-W, is a systematic, risk-based approach used to evaluate water and wastewater utilities from a range of threats that could cause an undesired event. It leverages the automated RAM-CI (critical infrastructure) prototype tool completed in September 2008, the manual RC RAM-W (RAMCAP compliant) approach completed in September 2007, the manual RAM-W, version 2, approach completed in 2002, and the requirements and needs of the Water Sector, EPA and DHS. The ARAM-W tool is a user-friendly tool which provides a sound scientific and technical framework to look at the total protection system. The ARAM-W tool provides the user the ability to determine a relative risk based on the threat, consequences and protection system effectiveness/vulnerability. It is a stand-alone PC-based tool which is compatible with the NIPP risk assessment methodology criteria as well as RAMPCAP. The ARAM-W process provides through a series of steps the ability to plan for the risk assessment; characterize the utility, facilities and assets; define the threat; identify undesired events and consequences; evaluate protection system effectiveness; determine risk; propose and evaluate upgrades if the risk is not acceptable and report on the assessment results.

Dang, Tam↗

Factors Associated with Secondary Functional Patency After Percutaneous Transluminal Angioplasty of the Early Failing or Immature Hemodialysis Arteriovenous Fistula

Purpose: To evaluate the efficacy of percutaneous transluminal angioplasty for early failing hemodialysis arteriovenous fistulas (AVFs) and predictors of secondary functional patency (FP). Methods: A review of our endovascular registry database showed that 61 patients with early failure after a surgically created AVF underwent endovascular intervention between 2011 and 2016. Median time from AVF creation to first intervention was 5.6 weeks. Median duration of follow-up was 14 months. Items related to the technical success rate and primary and secondary FP, and factors associated with secondary FP were analyzed. Results: Technical success was achieved in 55 (90%) of 61 patients. The primary and secondary FP rates were 42% and 65% at 12 months, respectively. Multivariate analysis showed that lesion length (HR; 1.15, P = 0.001) and lesions including juxta-AVF (the portion of fistula vein within 2 cm of the arteriovenous anastomosis, HR; 6.23, P = 0.008) were factors associated with reduced secondary FP. ROC curve analysis indicated lesion length with cutoff value ≥ 9 cm as a risk factor for reduced secondary FP. Secondary FP at 12 months for patients with no risk factors, with 1, and with 2 was 86%, 65%, and 0%, respectively. There was a significant difference in secondary FP rates among these groups (P = 0.001). Conclusions: A lesion length and juxta-AVF lesion are the risk factors for reduced secondary FP. The secondary FP rate at 12 months is acceptable in patients without risk factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative evaluation of common cause failures in high safety-significant safety-related digital instrumentation and control systems in nuclear power plants

Digital instrumentation and control (DI&C) systems at nuclear power plants (NPPs) have many advantages over analog systems. They are proven to be more reliable, cheaper, and easier to maintain given obsolescence of analog components. However, they also pose new engineering and technical challenges, such as possibility of common cause failures (CCFs) unique to digital systems. Here this paper proposes a Platform for Risk Assessment of DI&C (PRADIC) that is developed by Idaho National Laboratory (INL). A methodology for evaluation of software CCFs in high safety-significant safety-related DI&C systems of NPPs was developed as part of the framework. The framework integrates three stages of a typical risk assessment—qualitative hazard analysis and quantitative reliability and consequence analyses. The quantified risks compared with respective acceptance criteria provide valuable insights for system architecture alternatives allowing design optimization in terms of risk reduction and cost savings. A comprehensive case study performed to demonstrate the framework's capabilities is documented here in this paper. Results show that the PRADIC is a powerful tool capable to identify potential digital-based CCFs, estimate their probabilities, and evaluate their impacts on system and plant safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of clinical acceptability of an atlas-based segmentation algorithm for the delineation of organs at risk in head and neck cancer

Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel “similarity and truth estimation for propagated segmentations” (STEPS) compared to the traditional “simultaneous truth and performance level estimation” (STAPLE) algorithm. Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours. Dice similarity coefficient (DSC) was then used to compare the accuracy of these automatic methods. Second, in a blind experiment, three separate and distinct trained physicians graded manual and automatic segmentations into one of the following three grades: clinically acceptable as determined by universal delineation guidelines (grade A), reasonably acceptable for clinical practice upon manual editing (grade B), and not acceptable (grade C). Finally, STEPS segmentations graded B were selected and one of the physicians manually edited them to grade A. Editing time was recorded. Results: Significant improvements in DSC can be seen when using the STEPS algorithm on large structures such as the brainstem, spinal canal, and left/right parotid compared to the STAPLE algorithm (all p < 0.001). In addition, across all three trained physicians, manual and STEPS segmentation grades were not significantly different for the brainstem, spinal canal, parotid (right/left), and optic chiasm (all p > 0.100). In contrast, STEPS segmentation grades were lower for the eyes (p < 0.001). Across all OARs and all physicians, STEPS produced segmentations graded as well as manual contouring at a rate of 83%, giving a lower bound on this rate of 80% with 95% confidence. Reduction in manual interaction time was on average 61% and 93% when automatic segmentations did and did not, respectively, require manual editing. Conclusions: The STEPS algorithm showed better performance than the STAPLE algorithm in segmenting OARs for radiotherapy of the head and neck. It can automatically produce clinically acceptable segmentation of OARs, with results as relevant as manual contouring for the brainstem, spinal canal, the parotids (left/right), and optic chiasm. A substantial reduction in manual labor was achieved when using STEPS even when manual editing was necessary.

60 APPLIED LIFE SCIENCES↗

The Challenger tragedy was caused by an Apollo mistake, terminating risk analysis

NASA’s view of risk changed between early Apollo and the Space Shuttle. Risk was a known serious problem at the beginning of Apollo and the risk estimates were disturbingly high. To avoid public concern, risk analysis was discontinued. Risk analysis was avoided in Shuttle, leading to an unnecessarily risky design. The immediate cause of the Challenger tragedy was the mistaken decision to launch in cold weather. The fundamental cause was the high risk of the Shuttle design. Before Challenger, management thought and testified that the probability of an accident was 1 in 100,000. After Challenger, Probabilistic Risk Analysis (PRA) found a roughly 1 in 100 chance of a Shuttle failure. The recent Orion design uses the safer Apollo approach, with a hardened capsule, launch abort escape, and the crew placed above the rocket tanks and engines. During Apollo it was estimated that, “assuming all elements from propulsion to rendezvous and life support were done as well or better than ever before, that 30 astronauts would be lost before 3 were returned safely to the Earth.” The chance of astronaut survival was only 10%. After the Apollo 1 tragedy, the awareness of risk led to an intense focus on achieving safety. “The only possible explanation for the astonishing success – no losses in space and on time – was that every participant at every level in every area far exceeded the norm of human capabilities.” During Apollo, a NASA PRA found that the chance of success was “less than 5 percent.” The NASA Administrator felt that “the numbers could do irreparable harm,” and discontinued numerical risk assessment. This led to decreasing understanding of risk. The head of Apollo reliability and safety decided, “Statistics don’t count for anything,” and that risk is reduced by “attention taken in design.” The great and initially unexpected success of Apollo appeared to validate the neglect of PRA. Continuing to neglect the mathematical estimation of risk led Shuttle into a high risk design that produced tragic results. The initial design of the Shuttle emphasized increasing capability and reducing cost without analysis or even mention of risk. A retired NASA official stated, “some NASA people began to confuse desire with reality. … One result was to assess risk in terms of what was thought acceptable without regard for verifying the assessment. … Note that under such circumstances real risk management is shut out.” Not computing risk led to removing launch abort, removing crew escape, selecting less reliable Solid Rocket Boosters, placing the crew compartment next to the rocket boosters, and accepting more stressed shielding tile designs. Accepting these specific risks directly caused the shuttle disasters. The Challenger tragedy is frequently taught as a case of management failure. The focus is on the Challenger launch decision hours before, which is a dramatic example of bad management. However, the true cause of the Challenger disaster occurred decades earlier in the Apollo era. When the easily predictable failures occurred, failure investigations focused on how they might have been avoided. The Shuttle was cancelled after the space station was completed because of its high risk. The ultimate cause of the Shuttle tragedies was the choice by the Apollo-era NASA administrator to avoid a negative public reaction to realistic risk analysis.

Harry W. Jones↗

PRA (Probabilistic Risk Assessments) Participation versus Validation

Probabilistic Risk Assessments (PRAs) are performed for projects or programs where the consequences of failure are highly undesirable. PRAs primarily address the level of risk those projects or programs posed during operations. PRAs are often developed after the design has been completed. Design and operational details used to develop models include approved and accepted design information regarding equipment, components, systems and failure data. This methodology basically validates the risk parameters of the project or system design. For high risk or high dollar projects, using PRA methodologies during the design process provides new opportunities to influence the design early in the project life cycle to identify, eliminate or mitigate potential risks. Identifying risk drivers before the design has been set allows the design engineers to understand the inherent risk of their current design and consider potential risk mitigation changes. This can become an iterative process where the PRA model can be used to determine if the mitigation technique is effective in reducing risk. This can result in more efficient and cost effective design changes. PRA methodology can be used to assess the risk of design alternatives and can demonstrate how major design changes or program modifications impact the overall program or project risk. PRA has been used for the last two decades to validate risk predictions and acceptability. Providing risk information which can positively influence final system and equipment design the PRA tool can also participate in design development, providing a safe and cost effective product.

DeMott, Diana↗

Beryllium disease among construction trade workers at Department of Energy nuclear sites: A follow‐up

Abstract Background Construction workers at U.S. Department of Energy (DOE) nuclear weapons facilities are screened to identify DOE‐related occupational illnesses, including beryllium sensitization (BeS) and chronic beryllium disease (CBD). The study objectives were to estimate beryllium disease risks and the CBD claims acceptance rate in the energy workers' benefits program. Methods Workers diagnosed with BeS via beryllium lymphocyte proliferation test (BeLPT) included in screening examinations were interviewed about subsequent diagnosis of CBD. We estimated the proportion who developed CBD based on the ratio of CBD cases, based on self‐reported compensation claim status, to all workers with BeS interviewed. We used stratified analyses to explore trends in disease frequency by age, race, sex, DOE employment duration, site, trade group, and cigarette smoking history. Results Between 1998 and 2020, 21,854 workers received a BeLPT; 262 (1.20%) had BeS (two abnormals or one abnormal plus one borderline test); 212 (0.97%) had a single abnormal BeLPT. Of 177 BeS workers interviewed, 35 (19.8%) reported an accepted CBD compensation claim. The claims acceptance rate among BeS workers increased with years of DOE employment, from 8.4% with <5 years to 33.3% for >25 or more years. Five of 68 interviewed workers with a single positive BeLPT reported CBD claim acceptance; an additional CBD case was confirmed by chart review (8.8%). Conclusions Years of DOE work predict the risk of developing CBD among those sensitized and getting a claim for CBD accepted. Ongoing surveillance and increased awareness of the risk of beryllium exposure and CBD as an occupational disease among construction workers are needed.

Cloeren, Marianne↗

Occupant Protection at NASA

This slide presentation reviews NASA's efforts to arrive at protection of occupants of the ORION space craft on landing. An Abbreviated Injury Scale (AIS) has been developed, it is an anatomically-based, consensus-derived, global severity scoring system that classifies each injury by body region according to its relative importance on a 6-point ordinal scale. It reviews an Operationmally Relevant Injury Scale (ORIS), a classification methodology, and shows charts that detail the results of applying this ORIS to the injury databases. One chart uses NASCAR injury classification. It discusses providing a context for the level of risk inherent in the Orion landings in terms that people understand and have a sense for. For example is the risk of injury during an Orion landing roughly the same, better or worse than: An aircraft carrier landing, a NASCAR crash, or a helicopter crash, etc? The data for NASCAR and Indy Racing league (IRL) racing crash and injury data was reviewed. The risk from the Air Force, Navy, and Army injury data was also reviewed. Past NASA and the Soyuz programs injury risks are also reviewed. The work is an attempt to formulate a recommendation to the Orion Project for an acceptable level of injury risk associated with Nominal and Off-Nominal landing cases. The presentation also discusses the data mining and use of the data to Validate NASA Operationally-Relevant Injury Scale (NORIS) / Military Operationally-Relevant Injury Scale (MORIS), developing injury risk criteria, the types of data that are required, NASCAR modeling techniques and crash data, and comparison with the Brinkley model. The development of injury risk curves for each biodynamic response parameter is discussed. One of the main outcomes of this work is to establish an accurate Automated Test Dummy (ATD) that can be used to measure human tolerances.

Somers, Jeffrey↗

Evaluation of Planetary Extravehicular Activity Prebreathe Protocols using a 56.5 kPa, 34% O2, 66% N2 Saturation Cabin Atmosphere in an 11-day Hypobaric Hypoxia Study

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during Lunar extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. A cabin/vehicle “Exploration Atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies were initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 11-day human-in-the-loop system checkout. METHODS: Six volunteers lived in a hyboparic chamber for 11 days with an ‘exploration atmosphere’ of 56.6kPa/34% O2 66% N2. Subjects acclimated to the exploration atmosphere for 48hrs and thereafter participated in five 6-hour simulated EVAs at 34kPa/85% O2 / 15% N2 over the course of 11 days. Prior to each simulated EVA, subjects underwent a 20-minute prebreathe at 85% O2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was evaluated during the simulated EVA by serial doppler and echocardiographs alternating every 15min, as well as clinical monitoring for DCS signs/symptoms. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were present in 3 of 6 subjects during EVAs, with peak Grade II VGE as evaluated by Doppler and a peak Eftedal-Brubakk score of 5 by cardiac ultrasonography. Two cases of DCS were diagnosed during the 11-day test chamber. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Two cases of DCS (8%) does not cross either accept or reject pre-test criterion, so an additional study is planned for 2023 to meet our pre-test thresholds.

Alejandro Garbino↗

Demonstration of Oxygen and Carbon Monoxide Propellants for Mars Missions

Currently, proposed planetary exploration missions must be small, with low costs and a short development time. Relatively high-risk technologies are being accepted for such missions if they meet these guidelines. For a Mars sample-return mission, one of the higher risk technologies is the use of return propellants produced from indigenous materials such as the Martian atmosphere. This consists of 96 percent carbon dioxide, which can be processed into oxygen and carbon monoxide. This year, the NASA Lewis Research Center completed the experimental evaluation and subscale technology development of an oxygen/carbon monoxide propellant combination. Previous research included ignition characterization, combustion performance, and heat transfer characterization with gaseous propellants at room temperature. In this year s tests, we studied the ignition characteristics and combustion of oxygen and carbon monoxide at near liquid temperatures. The mixture ratio boundaries for oxygen and carbon monoxide were determined as a function of propellant temperature in a spark torch igniter. With both propellants at room temperature, the ignition range was between 0.50 and 1.44; and with both propellants chilled to near-liquid temperatures, it was between 2.4 and 3.1. Statistical analysis of the mean value of the ignition boundaries provided models that describe the combination of oxygen temperature, carbon monoxide temperature, and mixture ratio that resulted in ignition. This range is the larger boxed area shown in the figure. The smaller boxed area indicates the range at which there is a 90-percent confidence that ignition will occur. The relatively small range at only 90-percent confidence indicates that using the oxygen/carbon monoxide combination as its own ignition source may not be the best design for a remote engine operating on Mars. Tests also were performed in a simulated small rocket engine that used oxygen/hydrogen combustion gases as the ignition source for oxygen/carbon monoxide. In these experiments, the oxygen/carbon monoxide was successfully ignited in eight of eight tests at a mixture ratio of 0.52. In addition, the oxygen/carbon monoxide maintained steady combustion after the oxygen/hydrogen ignition source was removed, verifying that the oxygen/carbon monoxide rocket engine should continue to be included in mission plans as return propulsion from Mars.

Linne, Diane L.↗