Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHROUD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development of a locally mass flux conservative computer code for calculating 3-D viscous flow in turbomachines

The VANS successive approximation numerical method was extended to the computation of three dimensional, viscous, transonic flows in turbomachines. A cross-sectional computer code, which conserves mass flux at each point of the cross-sectional surface of computation was developed. In the VANS numerical method, the cross-sectional computation follows a blade-to-blade calculation. Numerical calculations were made for an axial annular turbine cascade and a transonic, centrifugal impeller with splitter vanes. The subsonic turbine cascade computation was generated in blade-to-blade surface to evaluate the accuracy of the blade-to-blade mode of marching. Calculated blade pressures at the hub, mid, and tip radii of the cascade agreed with corresponding measurements. The transonic impeller computation was conducted to test the newly developed locally mass flux conservative cross-sectional computer code. Both blade-to-blade and cross sectional modes of calculation were implemented for this problem. A triplet point shock structure was computed in the inducer region of the impeller. In addition, time-averaged shroud static pressures generally agreed with measured shroud pressures. It is concluded that the blade-to-blade computation produces a useful engineering flow field in regions of subsonic relative flow; and cross-sectional computation, with a locally mass flux conservative continuity equation, is required to compute the shock waves in regions of supersonic relative flow.

Walitt, L.↗

A preliminary assessment of the self-induced environment and contamination of the Space Telescope

Preliminary estimates for the internal pressures and surface contamination of the Space Telescope were made. The calculations for the transient pressures in the aft-shroud and telescope compartments considered two large communicating volumes that contain gaseous sources and sinks. The outgassing sources in the aft shroud consist of several scientific instruments, paints, insulations, and graphite-epoxy structures. With the exception of the instruments, these sources also exist in the telescope compartment. the outgassing functions were generated from ample test results at various temperatures and from internal pressure measurements in a vacuum test of one of the instruments. The venting occurs through combinations of series and parallel passages in both compartments. The calculated time constant of the two volumes and their respective passages, with the telescope protective door closed, is a few seconds, which is slightly less than that of the shuttle bay volume with the bay doors closed. With the telescope door closed, the pressures in the two compartments should decay to about 1OE-5 torr in about 200 hours. The contaminant deposits were assessed on the basis of expected partial pressures of the contaminant fraction of the outgassing. These pressures and the activation energies of the source materials were used to calculate the adsorbed and condensed deposits on the surfaces as a function of time.

Scialdone, J. J.↗

Measurement and evaluation of swirl-type flow in labyrinth seals of conventional turbine stages

The effects of load factor and rotor eccentricity were determined on flow conditions in test series for two stages. The results indicate that swirl-type entry flow follows the rules of potential swirl. Within the labyrinth cavities two spatial separated flow areas are considered. A dominating flow in periphera direction nearly fills the space between the sealing strips and the ceiling of the cavity. Below this flow, an area of axial mass transport is situated, with a slight peripheral component, limited on the nearest surroundings of the seals gap and the rotor surface. Between both flows, an exchange of energy takes place. Within the gaps, flow direction depends on axial velocity and therefore on variable flow contraction. A balance of energy within the seal and the cavities interprets the results of lateral force measurements as an influence of friction at the sealing strips surface and the rotating shaft surface. Stages with their blades put together in buckets by means of shrouding segments are particularly influenced by the rotating speed of the shrouding.

Hauck, L.↗

Laser surface fusion of plasma sprayed ceramic turbine seals

The thermal shock resistance of a ceramic layer is improved. An improved abradable lining that is deposited on a shroud forming a gas path seal in turbomachinery is emphasized. Improved thermal shock resistance of a shroud is effective through the deliberate introduction of 'benign' cracks. These are microcracks which will not propagate appreciably upon exposure to the thermal shock environment in which a turbine seal must function. Laser surface fusion treatment is used to introduce these microcracks. The ceramic surface is laser scanned to form a continuous dense layer. As this cools and solidifies, shrinkage results in the formation of a very fine crack network. The presence of this deliberately introduced fine crack network precludes the formation of a catastrophic crack during thermal shock exposure.

Wisander, D. W.↗

Vibration isolation and pressure compensation apparatus for sensitive instrumentation

A system for attenuating the inherent vibration associated with a mechanical refrigeration unit employed to cryogenically cool sensitive instruments used in measuring chemical constituents of the atmosphere is described. A modular system including an instrument housing and a reaction bracket with a refrigerator unit floated there between comprise the instrumentation system. A pair of evacuated bellows that "float' refrigerator unit and provide pressure compensation at all levels of pressure from seal level to the vacuum of space. Vibration isolators and when needed provide additional vibration damping for the refrigerator unit. A flexible thermal strap (20 K) serves to provide essentially vibration free thermal contact between cold tip of the refrigerator unit and the instrument component mounted on the IDL mount. Another flexible strap (77 K) serves to provide vibration free thermal contact between the TDL mount thermal shroud and a thermal shroud disposed about the thermal shaft.

Averill, R. D.↗

Method of fabricating an abradable gas path seal

The thermal shock resistance of a ceramic layer is improved. The invention is particularly directed to an improved abradable lining that is deposited on shroud forming a gas path in turbomachinery. Improved thermal shock resistance of a shroud is effected through the deliberate introduction of benign cracks. These are microcracks which will not propagate appreciably upon exposure to the thermal shock environment in which a turbine seal must function. Laser surface fusion treatment is used to introduce these microcracks. The ceramic surface is laser scanned to form a continuous dense layer. As this layer cools and solidifies, shrinkage results in the formation of a very fine crack network. The presence of this deliberately introduced fine crack network precludes the formation of a catastrophic crack during thermal shock exposure.

Bill, R. C.↗

Investigation of mixing in a turbofan exhaust duct. II Computer code application and verification

A three-dimensional analysis of turbofan forced mixer nozzle aerodynamics demonstrates that the complex flow structure is dominated by geometrically induced secondary flow rather than by turbulence. The test apparatus consisted of a fixed upstream model section and a rotating shroud. The Mach number of the fan and core streams at the mixing plane (lobe exit) was 0.45, the bypass ratio was about 4, and the Reynolds number based on the shroud radius was 1,100,000. The three velocity components near the exit plane of the lobes were measured using flow angularity probes to provide information about the mixer inflow conditions for turbulent computations. The validity of a previous computer code was demonstrated in a comparison of the nozzle exit temperature data with the computed temperature distributions. The mechanism most responsible for the generation of secondary flow within the lobes is due to the turning of the fan and core streams in opposite radial directions.

Povinelli, L. A.↗

Performance characteristics of an isolated coannular plug nozzle at transonic speeds

The Langley 16-Foot Transonic Tunnel was used to evaluate the performance characteristics of a coannular plug nozzle at static conditions (Mach number of 0) and at Mach numbers from 0.65 to 1.20. Jet total pressure ratio was varied from 1.0 (jet off) to 10.0. Thirty-seven configurations generated by the combination of three geometric variables - plug angle, shroud boattail length (fixed exit radius), and shroud extension length - were tested.

Mercer, C. E.↗

Hubble Space Telescope meteoroid-debris protection analysis

A system level failure could occur if the Hubble Space Telescope's (ST) capability to operate as a facility on-orbit is critically reduced or when a significant reduction in the quality of science data is registered. Failure could occur if a meteoroid/debris impact damages a component of a major support subsystem or if a meteoroid/debris penetration causes straylight contamination in the light shield, forward shell, aft shroud, or through the aperture door. The ST was analyzed to find the probability of no critical penetration. This probability value was found to be 92.25% for a two-year service life. A straylight leakage repair technique was recommended for the aft shroud, the region found most likely to be critically penetrated. Fozar tape and multilayer insulation blankets are suggested as posible repair materials.

Horn, J.↗

Development of gas-to-gas lift pad dynamic seals, volumes 1 and 2

Dynamic tests were performed on self acting (hydrodynamic) carbon face rotary shaft seals to assess their potential, relative to presently used labyrinth seals, for improving performance of aircraft gas turbine engines by reducing air leakage flow rate at compressor end seal locations. Three self acting bearing configurations, designed to supply load support at the interface of the stationary carbon seal and rotating seal race, were tested. Two configurations, the shrouded taper and shrouded flat step, were incorporated on the face of the stationary carbon seal element. The third configuration, inward pumping spiral grooves, was incorporated on the hard faced surface of the rotating seal race. Test results demonstrated seal leakage air flow rates from 75 to 95% lower that can be achieved with best state-of-the-art labyrinth designs and led to identification of the need for a more geometrically stable seal design configuration which is presently being manufactured for subsequent test evaluation.

Pope, A. N.↗

Meeting today's requirements for large thermal vacuum test facilities

The Lockheed Thermal Vacuum Facility at Sunnyvale, California, completed in late 1986, one of the largest multi-program facilities constructed to date is described. The horizontal 12.2 m diameter by 24.4 m long chamber has removable heads at each end and houses a thermal shroud providing a test volume 10.4 m diameter by 24.4 m long. The chamber and thermal shroud are configured to permit the insertion of a 6.1 m wide by 24.4 m long vibration isolated optical bench. The pumpimg system incorporates an internal cryopumping array, turbomolecular pumps and cryopumps to handle multi-program needs and ranges of gas loads. The high vacuum system is capable of achieving clean, dry and empty pressures below 1.3 times 10 to the minus 6 power Pa (10 to the minus 8 power torr.)

Corinth, R. L.↗

Design, development and evaluation of Stanford/Ames EVA prehensors

Space Station operations and maintenance are expected to make unprecedented demands on astronaut EVA. With Space Station expected to operate with an 8 to 10 psi atmosphere (4 psi for Shuttle operations), the effectivness of pressurized gloves is called into doubt at the same time that EVA activity levels are to be increased. To address the need for more frequent and complex EVA missions and also to extend the dexterity, duration, and safety of EVA astronauts, NASA Ames and Stanford University have an ongoing cooperative agreement to explore and compare alternatives. This is the final Stanford/Ames report on manually powered Prehensors, each of which consists of a shroud forming a pressure enclosure around the astronaut's hand, and a linkage system to transfer the motions and forces of the hand to mechanical digits attached to the shroud. All prehensors are intended for attachment to a standard wrist coupling, as found on the AX-5 hard suit prototype, so that realistic tests can be performed under normal and reduced gravity as simulated by water flotation.

Leifer, Larry J.↗

The Instrument Test Dewar (ITD): Testing satellite instruments at 1.5 K

The Instrument Test Dewar (ITD) is a cryogenic facility designed and built to test Cosmic Background Explorer (COBE) satellite instruments at 1.5 K. The facility provides a high vacuum and thermal environment with payload thermal, electrical and optical interfaces. There are two concentric vacuum spaces which are not hermitically sealed. The instrument vacuum space is 81.28 cm by 243.84 cm and is cooled by an LHe shroud. The guard vacuum space surrounds an LN2 shroud. There are two separate cryosorption pumping systems and a mechanical LHe pumping system. The data acquisition systems provide payload and housekeeping data. There have been various problems with the facility, and changes and improvements have been made to assure optimum test conditions. COBE instrument testing has been completed on structural, thermal model hardware and the protoflight units.

Milam, Laura J.↗

Rotating primary flow induction using jet-flapped blades

A new concept in ejector design is examined using primary jets exiting from a free spinning bladed rotor. This concept stems from a continuing effort in the development of Rotary-Jet thrust augmentors at George Washington University (GWU). An analysis of a Rotary-Jet rotor with jet-flapped blades is presented, identifying design trends beneficial to its performance. An experimental investigation was conducted to demonstrate the potential of this new concept. Several combinations of blade and shroud geometries were designed, fabricated and tested. The results are presented and discussed. Despite crudeness of fabrication, the maximum thrust augmentations obtained ranged from 1.55 to 2.14. These results demonstrate that this device is superior to all ejector designs tested with similar conventional passive diffusing shrouds.

Cordier, Stephane J.↗

Phase and time-resolved measurements of unsteady heat transfer and pressure in a full-stage rotating turbine

This paper presents detailed phase-resolved heat-flux data obtained on rotor blades and a comparison of simultaneously obtained time-resolved heat-flux and static pressure data obtained on the stationary shroud of a Garrett TFE 731-2 HP full-stage rotating turbine. A shock tube is used to generate a short-duration source of heated and pressurized air and platinum thin-film gages are used to obtain heat-flux measurements. Blade results are presented at several selected blade locations. Shroud surface pressure and heat-flux time histories are presented for comparable locations relative to the blade position.

Dunn, M. G.↗

High vacuum facility for hydrazine thruster testing

An ongoing modification is described of a large vacuum chamber to accommodate the ignition of an arcjet hydrazine thruster while maintaining a vacuum level of 1 x 10(exp -5) torr or less. The vacuum facility consists of a 20 ft stainless steel vacuum tank with an internal LN2 shroud, four 35 in. cryopumps and an 8 in. turbopump. To maintain a vacuum level of 1 x 10(exp -5) torr or less, 900 sq ft of liquid helium (LHe) shroud surface was installed to maintain the vacuum level and pumping requirements. A vacuum level of 1 x 10(exp -5) torr or less will allow the hydrazine thrust to exit the thruster nozzle and radiate into a space type environment so that the plume flow field can be analyzed and compared to the analytical model density distribution profile. Some other arcjet thruster characteristics measured are the electromagnetic interference (EMI) and exhaust contamination. This data is used to evaluate if the arcjet thruster with its high specific impulse in comparison to current chemical propulsion thruster can be used for the next generation of communication satellites.

Neary, Patrick F.↗

Optical testing cryogenic thermal vacuum facility

The construction of a turnkey cryogenic vacuum test facility was recently completed. The facility will be used to measure and record the surface profile of large diameter and 540 kg optics under simulated space conditions. The vacuum test chamber is a vertical stainless steel cylinder with a 3.5 diameter and a 7 m tangent length. The chamber was designed to maximize optical testing quality by minimizing the vibrations between the laser interferometer and the test specimen. This was accomplished by designing the chamber for a high natural frequency and vibration isolating the chamber. An optical test specimen is mounted on a movable presentation stage. During thermal vacuum testing, the specimen may be positioned to + or - 0.00025 cm accuracy with a fine adjustment mechanism. The chamber is evacuated by a close coupled Roots-type blower and rotary vane pump package and two cryopumps. The chamber is equipped with an optically dense gaseous nitrogen cooled thermal shroud. The thermal shroud is used to cool or warm the optical test specimen at a controlled rate. A control system is provided to automatically evacuate the chamber and cooldown the test specimen to the selected control temperature.

Dohogne, Patrick W.↗

Special requirements in the design of a sensor test and integration laboratory

Special needs are imposed on the design and operation of a sensor test and integration lab. Cryogenic temperature, vibration isolation for electro-optical equipment, contamination control, thermal control to reduce or minimize thermally induced stresses on mirrors and supporting metering structure, thermal vacuum chamber shroud temperature uniformity, and varying temperature control capability to bring optical equipment from cryogenic temperature to ambient environment, and real time processing are some of the stringent needs that must be addressed before a facility can be accepted to perform sensor test and integration. Most of the sensor tests are performed at cryogenic temperature, and thermal isolation of the test article from the ambient temperature is a strong consideration for the thermal vacuum chamber design. Also, equipment heat and parasitic heat sources must be able to be removed from the chamber without exceeding the chamber shroud temperature gradients. How these needs were met in the design, build, and acceptance test of the Grumman Sensor Test and Integration Lab (STIL) is described.

Bellanca, S.↗