Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The influence of the ionizer geometry on the absolute density calibration of reactive neutral species in a molecular beam mass spectrometry

Molecular beam mass spectrometry is a powerful diagnostic technique, which can be used for the measurement of absolute number densities of reactive species in non-equilibrium reactive plasmas. However, the calibration of absolute number densities is susceptible to systematic errors. Critical issues are the proper design of the sampling system and the correction of the background signal. Here we discuss the effect of reflections of particles from the molecular beam in an ionizer, formation of additional background particle density in the ionizer, and its effect on the density calibration of reactive particle densities. A Monte Carlo simulation of particle trajectories in the ionizer is used to estimate the detection probability of a beam particle after the collision with the ionizer wall. The simulation shows that as much as two-third of the signal can be due to scattered particles in the commercially available mass spectrometers. This effect leads to systematic underestimation of densities of reactive particles, which are reactive at the surface and, therefore, do not have any background density. A simple change in the ionizer geometry is suggested, which can significantly reduce this problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical expressions for the gate utilization factors of passive multiplicity counters including signal build-up

In the realm of nuclear safeguards, passive neutron multiplicity counting using shift register pulse train analysis to nondestructively quantify Pu in product materials is a familiar and widely applied technique. The approach most commonly taken is to construct a neutron detector consisting of {sup 3}He filled cylindrical proportional counters embedded in a high density polyethylene moderator. Fast neutrons from the item enter the moderator and are quickly slowed down, on timescales of the order of 1-2 {micro}s, creating a thermal population which then persists typically for several 10's {micro}s and is sampled by the {sup 3}He detectors. Because the initial transient is of comparatively short duration it has been traditional to treat it as instantaneous and furthermore to approximate the subsequent capture time distribution as exponential in shape. With these approximations simple expressions for the various Gate Utilization Factors (GUFs) can be obtained. These factors represent the proportion of time correlated events i.e. Doubles and Triples signal present in the pulse train that is detected by the coincidence gate structure chosen (predelay and gate width settings of the multiplicity shift register). More complicated expressions can be derived by generalizing the capture time distribution to multiple time components or harmonics typically present in real systems. When it comes to applying passive neutron multiplicity methods to extremely intense (i.e. high emission rate and highly multiplying) neutron sources there is a drive to use detector types with very fast response characteristics in order to cope with the high rates. In addition to short pulse width, detectors with a short capture time profile are also desirable so that a short coincidence gate width can be set in order to reduce the chance or Accidental coincidence signal. In extreme cases, such as might be realized using boron loaded scintillators, the dieaway time may be so short that the build-up (thermalization transient) within the detector cannot be ignored. Another example where signal build-up might be observed is when a {sup 3}He based system is used to track the evolution of the time correlated signal created by a higher multiplying item within a reflective configuration such as the measurement of a spent fuel assembly. In this work we develop expressions for the GUFs which include signal build-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring CO 2 Storage at Cranfield, Mississippi with Time-Lapse Offset VSP – Using Integration and Modeling to Reduce Uncertainty

A time-lapse Offset Vertical Seismic Profile (OVSP) data set was acquired as part of a subsurface monitoring program for geologic sequestration of CO 2 . The storage site at Cranfield, near Natchez, Mississippi, is part of a detailed area study (DAS) site for geologic carbon sequestration operated by the U.S. Dept. of Energy’s Southeast Regional Carbon Sequestration Partnership (SECARB). The DAS site includes three boreholes, an injection well and two monitoring wells. The project team selected the DAS site to examine CO 2 sequestration multiphase fluid flow and pressure at the interwell scale in a brine reservoir. The time-lapse (TL) OVSP was part of an integrated monitoring program that included well logs, crosswell seismic, electrical resistance tomography and 4D surface seismic. The goals of the OVSP were to detect the CO 2 induced change in seismic response, give information about the spatial distribution of CO 2 near the injection well and to help tie the high-resolution borehole monitoring to the 4D surface data. The VSP data were acquired in well CFU 31-F1, which is the ~3200 m deep CO 2 injection well at the DAS site. A preinjection survey was recorded in late 2009 with injection beginning in December 2009, and a post injection survey was conducted in Nov 2010 following injection of about 250 kT of CO 2 . The sensor array for both surveys was a 50-level, 3-component, Sercel MaxiWave system with 15 m (49 ft) spacing between levels. The source for both surveys was an accelerated weight drop, with different source trucks used for the two surveys. Consistent time-lapse processing was applied to both data sets. Time-lapse processing generated difference corridor stacks to investigate CO 2 induced reflection amplitude changes from each source point. Corridor stacks were used for amplitude analysis to maximize the signal-to-noise ratio (S/N) for each shot point. Spatial variation in reflectivity (used to ‘map’ the plume) was similar in magnitude to the corridor stacks but, due to relatively lower S/N, the results were less consistent and more sensitive to processing and therefore are not presented. We examined the overall time-lapse repeatability of the OVSP data using three methods, the NRMS and Predictability (Pred) measures of Kragh and Christie (2002) and the signal-to-distortion ratio (SDR) method of Cantillo (2011). Because time-lapse noise was comparable to the observed change, multiple methods were used to analyze data reliability. The reflections from the top and base reservoir were identified on the corridor stacks by correlation with a synthetic response generated from the well logs. A consistent change in the corridor stack amplitudes from pre- to post-CO 2 injection was found for both the top and base reservoir reflections on all ten shot locations analyzed. In addition to the well-log synthetic response, a finite-difference elastic wave propagation model was built based on rock/fluid properties obtained from well logs, with CO 2 induced changes guided by time-lapse crosswell seismic tomography (Ajo-Franklin, et al., 2013) acquired at the DAS site. Time-lapse seismic tomography indicated that two reservoir zones were affected by the flood. The modeling established that interpretation of the VSP trough and peak event amplitudes as reflectivity from the top and bottom of reservoir is appropriate even with possible tuning effects. Importantly, this top/base change gives confidence in an interpretation that these changes arise from within the reservoir, not from bounding lithology. The modeled time-lapse change and the observed field data change from 10 shotpoints are in agreement for both magnitude and polarity of amplitude change for top and base of reservoir. Therefore, we conclude the stored CO 2 has been successfully detected and, furthermore, the observed seismic reflection change can be applied to Cranfield’s 4D surface seismic for spatially delineating the CO 2 /brine interface.

54 ENVIRONMENTAL SCIENCES↗

Differential transcriptomic alterations in nasal versus lung tissue of acrolein-exposed rats

Introduction: Acrolein is a significant component of anthropogenic and wildfire emissions, as well as cigarette smoke. Although acrolein primarily deposits in the upper respiratory tract upon inhalation, patterns of site-specific injury in nasal versus pulmonary tissues are not well characterized. This assessment is critical in the design of in vitro and in vivo studies performed for assessing health risk of irritant air pollutants. Methods: In this study, male and female Wistar-Kyoto rats were exposed nose-only to air or acrolein. Rats in the acrolein exposure group were exposed to incremental concentrations of acrolein (0, 0.1, 0.316, 1 ppm) for the first 30 min, followed by a 3.5 h exposure at 3.16 ppm. In the first cohort of male and female rats, nasal and bronchoalveolar lavage fluids were analyzed for markers of inflammation, and in a second cohort of males, nasal airway and left lung tissues were used for mRNA sequencing. Results: Protein leakage in nasal airways of acrolein-exposed rats was similar in both sexes; however, inflammatory cells and cytokine increases were more pronounced in males when compared to females. No consistent changes were noted in bronchoalveolar lavage fluid of males or females except for increases in total cells and IL-6. Acrolein-exposed male rats had 452 differentially expressed genes (DEGs) in nasal tissue versus only 95 in the lung. Pathway analysis of DEGs in the nose indicated acute phase response signaling, Nrf2-mediated oxidative stress, unfolded protein response, and other inflammatory pathways, whereas in the lung, xenobiotic metabolism pathways were changed. Genes associated with glucocorticoid and GPCR signaling were also changed in the nose but not in the lung. Discussion: These data provide insights into inhaled acrolein-mediated sex-specific injury/inflammation in the nasal and pulmonary airways. The transcriptional response in the nose reflects acrolein-induced acute oxidative and cytokine signaling changes, which might have implications for upper airway inflammatory disease susceptibility.

Alewel, Devin I.↗

A PRACTICAL THEOREM ON USING INTERFEROMETRY TO MEASURE THE GLOBAL 21 cm SIGNAL

The sky-averaged, or global, background of redshifted 21 cm radiation is expected to be a rich source of information on cosmological reheating and reionization. However, measuring the signal is technically challenging: one must extract a small, frequency-dependent signal from under much brighter spectrally smooth foregrounds. Traditional approaches to study the global signal have used single antennas, which require one to calibrate out the frequency-dependent structure in the overall system gain (due to internal reflections, for example) as well as remove the noise bias from auto-correlating a single amplifier output. This has motivated proposals to measure the signal using cross-correlations in interferometric setups, where additional calibration techniques are available. In this paper we focus on the general principles driving the sensitivity of the interferometric setups to the global signal. We prove that this sensitivity is directly related to two characteristics of the setup: the cross-talk between readout channels (i.e., the signal picked up at one antenna when the other one is driven) and the correlated noise due to thermal fluctuations of lossy elements (e.g., absorbers or the ground) radiating into both channels. Thus in an interferometric setup, one cannot suppress cross-talk and correlated thermal noise without reducing sensitivity to the global signal by the same factor—instead, the challenge is to characterize these effects and their frequency dependence. We illustrate our general theorem by explicit calculations within toy setups consisting of two short-dipole antennas in free space and above a perfectly reflecting ground surface, as well as two well-separated identical lossless antennas arranged to achieve zero cross-talk.

79 ASTRONOMY AND ASTROPHYSICS↗

High order reflectivity of highly oriented pyrolytic graphite crystals for x-ray energies up to 22 keV

We used Kr K{alpha} (12.6 keV), Zr K{alpha} (15.7 keV), and Ag K{alpha} (22.2 keV) x-rays, produced by petawatt-class laser pulses, to measure the integrated crystal reflectivity R{sub int} of flat highly oriented pyrolytic graphite (HOPG) up to the fifth order. The maximum R{sub int} was observed in first order (3.7 mrad at 12.6 keV), decreasing by a factor of 3-5 for every successive order, and dropping by a factor of 2-2.5 at 22.2 keV. The current study indicates that HOPG crystals are suitable for measuring scattering signals from high energy x-ray sources (E{>=}20 keV). These energies are required to penetrate through the high density plasma conditions encountered in inertial confinement fusion capsule implosions on the National Ignition Facility.

07 ISOTOPE AND RADIATION SOURCES↗

Reflections of ions in electrostatic analyzers: A case study with New Horizons/Solar Wind Around Pluto

Electrostatic analyzers (ESAs), in various forms, are used to measure plasma in a range of applications. In this article, we describe how ions reflect from the interior surfaces of an ESA, the detection of which constitutes a fundamentally nonideal response of ESAs. We demonstrate this effect by comparing laboratory data from a real ESA-based space instrument, the Solar Wind Around Pluto (SWAP) instrument, aboard the NASA New Horizons spacecraft, to results from a model based on quantum mechanical simulations of particles reflected from the instrument's surfaces combined with simulations of particle trajectories through the instrument's applied electrostatic fields. Thus, we show, for the first time, how reflected ions in ESAs lead to nonideal effects that have important implications for understanding the data returned by these instruments, as well as for designing new low-background ESA-based instruments. Specifically, we show that the response of SWAP widens considerably below a level of 10{sup -3} of the peak response. Thus, a direct measurement of a plasma distribution with SWAP will have an energy-dependent background on the order of {<=}10{sup -3} of the peak of the signal due to that distribution. We predict that this order of magnitude estimate for the background applies to a large number of ESA-based instruments because ESAs operate using a common principle. However, the exact shape of the energy-dependent response will be different for different instruments. The principle of operation is that ions outside the ideal range of energy-per-charge are deflected into the walls of the ESA. Therefore, we propose that a new design paradigm is necessary to mitigate the effect of ion reflections and thus accurately and directly measure the energy spectrum of a plasma using ESAs. In this article, we build a framework for minimizing the effect of ion reflections in the design of new ESAs. Through the use of existing computer simulation software, a design team can use our method to quantify the amount of reflections in their instrument and iteratively change design parameters before fabrication, conserving resources. A possible direction for the new design paradigm is having nonsolid walls of the ESA, already used in some applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorption and related optical dispersion effects on the spectral response of a surface plasmon resonance sensor

Surface plasmon resonance (SPR) sensing is an optical technique that allows real time detection of small changes in the physical properties, in particular in the refractive index, of a dielectric medium near a metal film surface. One way to increase the SPR signal shift is then to incorporate a substance possessing a strong dispersive refractive index in the range of the plasmon resonance band. In this paper, we investigate the impact of materials possessing a strong dispersive index integrated to the dielectric medium on the SPR reflectivity profile. We present theoretical results based on chromophore absorption spectra and on their associated refractive index obtained from the Lorentz approach and Kramers-Kroenig equations. As predicted by the theory, the experimental results show an enhancement of the SPR response, maximized when the chromophore absorption band coincides with the plasmon resonant wavelength. This shows that chromophores labeling can provide a potential way for SPR response enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Addressing Energy Demand through Demand Response. International Experiences and Practices

Demand response (DR) is a load management tool which provides a cost-effective alternative to traditional supply-side solutions to address the growing demand during times of peak electrical load. According to the US Department of Energy (DOE), demand response reflects “changes in electric usage by end-use customers from their normal consumption patterns in response to changes in the price of electricity over time, or to incentive payments designed to induce lower electricity use at times of high wholesale market prices or when system reliability is jeopardized.” 1 The California Energy Commission (CEC) defines DR as “a reduction in customers’ electricity consumption over a given time interval relative to what would otherwise occur in response to a price signal, other financial incentives, or a reliability signal.” 2 This latter definition is perhaps most reflective of how DR is understood and implemented today in countries such as the US, Canada, and Australia where DR is primarily a dispatchable resource responding to signals from utilities, grid operators, and/or load aggregators (or DR providers).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Water reflection analysis of encapsulated photovoltaic modules

A method for moisture testing of a fully assembled photovoltaic (PV) module. An assembled PV module is probed with short wave IR probe energy in the range of 1700-2000 nm. Energy reflected from the assembled PV module is collected and directed to a sensor. Noise is removed from a signal of the sensor with reference to the probe energy. Absorption is of the probe energy is determined. The absorption is correlated to moisture in the PV module. A preferred system that carries out the method provides a signal-to-noise ratio (as defined by standard deviation/mean of measured reflectance) of at least 3800.

Fenning, David↗

Modeling the Transmission of Optical Lightning Signals Through Complex 3‐D Cloud Scenes

Abstract Space‐based lightning imagers have shown that complex cloud scenes consisting of multiple tall convective features, anvil clouds, and warm boundary cloud layers are illuminated by lightning in many different ways depending on where the lightning occurs and how energetic it is. Modifications to the optical lightning signals from radiative transfer in the cloud medium can lead to reductions in detection efficiency and location accuracy for these instruments and can also cause some of the optical signals that are detected to have unexpected spatial energy distributions. In this study, we perform Monte Carlo radiative transfer simulations of optical lightning emissions in clouds with complex 3‐D geometries to shed some light on the origins of certain irregular radiance patterns that have been recorded from orbit. We show that diffuse reflections off nearby cloud faces can explain lightning signals in nonelectrified clouds, tall clouds can result in poor optical transmission and suppressed radiances that could lead to missed events and that particularly favorable viewing conditions can cause otherwise normal lightning to produce a superbolt that is orders of magnitude brighter than the same flash seen from a different angle.

54 ENVIRONMENTAL SCIENCES↗

A contactless approach for respiratory gating in PET using continuous-wave radar

Purpose: Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient’s torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. Methods: The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient’s torso. A 24 GHz carrier frequency was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [{sup 18}F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. Results: The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69–0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53–0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin. Conclusions: Accurate respiratory signals were obtained successfully by the proposed method with high spatial and temporal resolution. By working without contact and passing through clothing and blankets, this approach minimizes preparation time and increases the convenience of the patient during the scan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self‐Standing Chiral Covalent Organic Framework Thin Films with Full‐Color Tunable Guest‐Induced Circularly Polarized Luminescence

Abstract Exploring self‐standing chiral covalent organic framework (COF) thin films with controllable circularly polarized luminescence (CPL) is of paramount significance but remains a challenging task. Herein, we demonstrate the first example of self‐standing chiral COF films employing a polymerization‐dispersion‐filtration strategy. Pristine, low‐quality chiral COF films were produced by interfacial polymerization and then re‐dispersed into COF colloidal solutions. Via vacuum assisted assembly, these COF colloids were densely stacked and assembled into self‐standing, pure chiral COF films ( L‐ / D‐ CCOF‐F) that were transparent, smooth, crack‐free and highly crystalline. These films were tunable in thicknesses, areas, and roughness, along with strong diffuse reflectance circular dichroism (DRCD) and cyan CPL signals, showing an intrinsic luminescence asymmetric factor ( g lum ) of ~4.3×10 −3 . Furthermore, these COF films served as host adsorbents to load various achiral organic dye guests through adsorption. The effective chiral transfer and energy transfer between CCOF‐F and achiral fluorescent dyes endowed the dyes with strong chirality and tunable DRCD, resulting in intense, full‐color‐tunable solid‐state CPL. Notably, the ordered arrangement of dye guest molecules within the preferentially oriented chiral pores of CCOF‐F contributed to an amplified | g lum | factor of up to 7.2×10 −2 , which is state‐of‐the‐art for COF‐based CPL materials. This work provides new insights into the design and fabrication of self‐standing chiral COF films, demonstrating their great potential for chiroptical applications.

Tang, Xihao↗

Phase-controlled, heterodyne laser-induced transient grating measurements of thermal transport properties in opaque material

The methodology for a heterodyned laser-induced transient thermal grating technique for non-contact, non-destructive measurements of thermal transport in opaque material is presented here. Phase-controlled heterodyne detection allows us to isolate pure phase or amplitude transient grating signal contributions by varying the relative phase between reference and probe beams. The phase grating signal includes components associated with both transient reflectivity and surface displacement whereas the amplitude grating contribution is governed by transient reflectivity alone. By analyzing the latter with the two-dimensional thermal diffusion model, we extract the in-plane thermal diffusivity of the sample. Measurements on a 5 μm thick single crystal PbTe film yielded excellent agreement with the model over a range of grating periods from 1.6 to 2.8 μm. The measured thermal diffusivity of 1.3 × 10 -6 m 2 /s was found to be slightly lower than the bulk value.

36 MATERIALS SCIENCE↗

Laser measurement of H{sup -} ions in a field-effect-transistor based radio frequency ion source

Hydrogen negative ion density measurements are required to clarify the characteristics of negative ion production and ion source performance. Both of laser photodetachment and cavity ring down (CRD) measurements have been implemented to a field-effect-transistor based radio-frequency ion source. The density ratio of negative hydrogen ions to electrons was successfully measured by laser photodetachment and effect of magnetic filter field on negative ion density was confirmed. The calculated CRD signal showed that CRD mirrors with >99.990% reflectivity are required and loss of reflectivity due to cesium contamination should be minimized.

43 PARTICLE ACCELERATORS↗

Remote sensor response study in the regime of the microwave radiation-induced magnetoresistance oscillations

A concurrent remote sensing and magneto-transport study of the microwave excited two dimensional electron system (2DES) at liquid helium temperatures has been carried out using a carbon detector to remotely sense the microwave activity of the 2D electron system in the GaAs/AlGaAs heterostructure during conventional magneto-transport measurements. Various correlations are observed and reported between the oscillatory magnetotransport and the remotely sensed reflection. In addition, the oscillatory remotely sensed signal is shown to exhibit a power law type variation in its amplitude, similar to the radiation-induced magnetoresistance oscillations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation and analysis on ultrasonic testing for the cement grouting defects of the corrugated pipe

The defects exist in the cement grouting process of prestressed corrugated pipe may directly impair the bridge safety. In this paper, sound fields propagation in concrete structures with corrugated pipes and the influence of various different defects are simulated and analyzed using finite element method. The simulation results demonstrate a much complex propagation characteristic due to multiple reflection, refraction and scattering, where the scattering signals caused by metal are very strong, while the signals scattered by an air bubble are weaker. The influence of defect both in time and frequency domain are found through deconvolution treatment. In the time domain, the deconvolution signals correspond to larger defect display a larger head wave amplitude and shorter arrive time than those of smaller defects; in the frequency domain, larger defect also shows a stronger amplitude, lower center frequency and lower cutoff frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of interstitial Mn on local structure and magnetism in Mn 1 + δ Sb

We report x-ray total scattering and pair distribution function (PDF) studies of the structural relaxation around interstitial manganese (Mn i ) in ferromagnetic Mn 1+δ Sb (0.03 ≤ δ ≤ 0.23) alloys, guided by density functional theory (DFT). Refinements to the experimental PDF using a crystallographically constrained structural model indicate an expansion in the equatorial plane of the Mn i Sb 5 trigonal bipyramidal site, which introduces significant positional disorder in addition to the nominally random occupation of interstitial voids. Observation of a weak diffuse signal near the symmetry-forbidden (001) reflection position is indicative of correlated disorder from the clustering of Mn i . Density functional relaxation of supercells approximating the δ = 0.08, 0.15, and 0.23 compositions provides improved models that accurately describe the short-range structural distortions captured in the PDFs. Furthermore, such structural relaxation increases the DFT calculated moment on Mn i , which aligns antiparallel to the primary Mn moments, but leads to insubstantial changes in the average Mn and Sb moments and moments of Mn and Sb proximal to interstitials, thus providing a more accurate description of the observed bulk magnetic properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗