Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE PHOTON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗

Plans to improve the experimental limit in the comparison of the east-west and west-east one-way light propagation times on the rotating earth

The preceding paper describes the results so far (interrupted in the Spring of 1989 because of lack of funds) of an experiment comparing the one-way light propagation times on the surface of the rotating Earth. For the 20 Km path length component in the East-West direction the predicted difference between the opposite sense propagation times would be 160 ps, if the approximately 360 Km/s surface speed of the Earth gives effective light speeds of 3 x 10(exp 8) m/s +/- 360 m/s. This could lead to a prediction of the difference between the clock transport and the light pulse synchronization methods described in the preceding paper: delta(T) = 0.5 (160) = 80 ps. The current upper bound of approximately 100 ps for delta(T) is limited by poorly understood systematic errors. The most important seems to be intensity-dependent time delays in the remote light pulse avalanche photo-diode detector. This will be replaced by a continuously operating circular scan streak camera having single photon sensitivity and a time resolution of approximately 5 ps. (This camera has recently been developed by the Xian Institute of Optics and Precision Mechanics in the P.R.C.). Better isolation from shocks and vibration for the Sigma-Tau hydrogen maser during transport will be provided. It is hoped that delta(T) is less than 20 ps can be achieved.

Alley, C. O.↗

Fabrication of Feedhorn-Coupled Transition Edge Sensor Arrays for Measurement of the Cosmic Microwave Background Polarization

Characterization of the minute cosmic microwave background polarization signature requires multi-frequency high-throughput precision instrument systems. We have previously described the detector fabrication of a 40 GHz focal plane and now describe the fabrication of the detector modules for measurement of the CMB at 90GHz. The 74-TES based bolometers in each module are coupled to a niobium based planar orthomode transducer with integrated band defining filters implemented in microstrip transmission line. A single crystal silicon dielectric substrate serves as microstrip dielectric and as a thermal link between the membrane isolated MoAu TES operating at 150mK and the heat bath. A short silicon leg between the heat bath and the TES bolometer is designed for ballistic phonon transport and provides improved process control and uniformity of thermal conductance in the presence of phonon scattering on roughened surfaces. Micro-machined structures are used to realize the orthomode transducer backshort, provide out of band signal rejection, and a silicon photonic choke for feedhorn coupling are described. The backshort, choke wafer, and detector wafer are indium bump bonded to create a single 37-element dual-polarization detector module. Fourteen such hexagonally shaped modules each 90 mm in size comprise two focal planes. These, along with the recently delivered 40GHz focal plane, will survey a large fraction of the sky as part of the Johns Hopkins University led ground based CLASS (Cosmology Large Angular Scale Surveyor) telescope.

Characterization↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time-pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data

In accordance with some embodiments, systems, methods, and media for high dynamic range imaging using single-photon and conventional image sensor data are provided. In some embodiments, the system comprises: first detectors configured to detect a level of photons proportional to incident photon flux; second detectors configured to detect arrival of individual photons; a processor programmed to: receive, from the first detectors, first values indicative of photon flux from a scene with a first resolution; receive, from the second detectors, second values indicative of photon flux from the scene with a lower resolution; provide a first encoder of a trained machine learning model first flux values based on the first values, provide the second encoder of the model second flux values; receive, as output, values indicative of photon flux from the scene; and generate a high dynamic range image based on the third plurality of values.

Gutierrez Barragan, Felipe↗

Fabrication of Feedhorn-Coupled Transition Edge Sensor Arrays for Measurement of the Cosmic Microwave Background Polarization

Characterization of the minute cosmic microwave background (CMB) polarization signature requires multi-frequency high-throughput precision instrument systems. We have previously described the detector fabrication of a 40 gigahertz focal plane and now describe the fabrication of a 37-element dual-polarization detector module for measurement of the CMB at 90 gigahertz. The 72-TES (Transition Edge Sensor)-based bolometers in each module are coupled to a niobium-based planar orthomode transducer with integrated band defining filters implemented in microstrip transmission line. A single crystal silicon dielectric substrate serves as microstrip dielectric and as a thermal link between the membrane isolated MoAu TES operating at 150 millikelvins and the heat bath. A short silicon leg between the heat bath and the TES bolometer is designed for ballistic phonon transport and provides improved process control and uniformity of thermal conductance in the presence of phonon scattering on roughened surfaces. Micro-machined structures are used to realize the orthomode transducer backshort, provide out of band signal rejection, and a silicon photonic choke for feedhorn coupling are described. The backshort, choke wafer, and detector wafer are indium bump-bonded to create a single 37-element dual-polarization detector module. Fourteen such hexagonally shaped modules each 80 millimeters in size comprise two focal planes. These, along with the recently delivered 40 gigahertz focal plane, will survey a large fraction of the sky as part of the Johns Hopkins University-led ground-based CLASS (Cosmology Large Angular Scale Surveyor) telescope.

Detectors↗

Volume IV. The DUNE far detector single-phase technology

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. Central to achieving DUNE's physics program is a far detector that combines the many tens-of-kiloton fiducial mass necessary for rare event searches with sub-centimeter spatial resolution in its ability to image those events, allowing identification of the physics signatures among the numerous backgrounds. In the single-phase liquid argon time-projection chamber (LArTPC) technology, ionization charges drift horizontally in the liquid argon under the influence of an electric field towards a vertical anode, where they are read out with fine granularity. A photon detection system supplements the TPC, directly enhancing physics capabilities for all three DUNE physics drivers and opening up prospects for further physics explorations. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume IV presents an overview of the basic operating principles of a single-phase LArTPC, followed by a description of the DUNE implementation. Each of the subsystems is described in detail, connecting the high-level design requirements and decisions to the overriding physics goals of DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-demand indistinguishable single photons from an efficient and pure source based on a Rydberg ensemble

Single photons coupled to atomic systems have shown to be a promising platform for developing quantum technologies. Yet a bright on-demand, highly pure, and highly indistinguishable single-photon source compatible with atomic platforms is lacking. In this work, we demonstrate such a source based on a strongly interacting Rydberg system. The large optical nonlinearities in a blockaded Rydberg ensemble convert coherent light into a single collective excitation that can be coherently retrieved as a quantum field. We simultaneously observe a fully single-mode (spectral, temporal, spatial, and polarization) efficiency up to 0.098(2), a detector-background-subtracted g ( 2 ) = 5.0 ( 1.6 ) × <#comment/> 10 − <#comment/> 4 , and indistinguishability of 0.980(7), at an average photon production rate of 1.18 ( 2 ) × <#comment/> 10 4 s − <#comment/> 1 . All of these make this system promising for scalable quantum information applications. Furthermore, we investigate the effects of contaminant Rydberg excitations on the source efficiency and observed single-mode efficiencies up to 0.18(2) for lower photon rates. Finally, recognizing that many quantum information protocols require a single photon in a fully single mode, we introduce metrics that take into account all degrees of freedom to benchmark the performance of on-demand sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of inclusive and differential cross-sections of $t\overline{t}\gamma$ production in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

Inclusive and differential cross-sections are measured at particle level for the associated production of a top quark pair and a photon ($t\overline{t}\gamma$). The analysis is performed using an integrated luminosity of 140 fb -1 of proton-proton collisions at a centre-of-mass energy of 13 TeV collected by the ATLAS detector. The measurements are performed in the single-lepton and dilepton top quark pair decay channels focusing on ($t\overline{t}\gamma$) topologies where the photon is radiated from an initial-state parton or one of the top quarks. The absolute and normalised differential cross-sections are measured for several variables characterising the photon, lepton and jet kinematics as well as the angular separation between those objects. The observables are found to be in good agreement with the Monte Carlo predictions. The photon transverse momentum differential distribution is used to set limits on effective field theory parameters related to the electroweak dipole moments of the top quark. The combined limits using the photon and the Z boson transverse momentum measured in $t\overline{t}$ production in associations with a Z boson are also set.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate

SiGe is an important semiconductor alloy for high-speed field effect transistors (FETs), high-temperature thermoelectric devices, photovoltaic solar cells, and photon detectors. The growth of SiGe layer is difficult because SiGe alloys have different lattice constants from those of the common Si wafers, which leads to a high density of defects, including dislocations, micro-twins, cracks, and delaminations. This innovation utilizes newly developed rhombohedral epitaxy of cubic semiconductors on trigonal substrates in order to solve the lattice mismatch problem of SiGe by using trigonal single crystals like sapphire (Al2O3) as substrate to give a unique growth-orientation to the SiGe layer, which is automatically controlled at the interface upon sapphire (0001). This technology is different from previous silicon on insulator (SOI) or SGOI (SiGe on insulator) technologies that use amorphous SiO2 as the growth plane. A cubic semiconductor crystal is a special case of a rhombohedron with the inter-planar angle, alpha = 90 deg. With a mathematical transformation, all rhombohedrons can be described by trigonal crystal lattice structures. Therefore, all cubic lattice constants and crystal planes (hkl) s can be transformed into those of trigonal crystal parameters. These unique alignments enable a new opportunity of perfect lattice matching conditions, which can eliminate misfit dislocations. Previously, these atomic alignments were thought to be impossible or very difficult. With the invention of a new x-ray diffraction measurement method here, growth of cubic semiconductors on trigonal crystals became possible. This epitaxy and lattice-matching condition can be applied not only to SiGe (111)/sapphire (0001) substrate relations, but also to other crystal structures and other materials, including similar crystal structures which have pointgroup rotational symmetries by 120 because the cubic (111) direction has 120 rotational symmetry. The use of slightly miscut (less than plus or minus 10 deg.) sapphire (0001) substrate can be used to improve epitaxial relationships better by providing attractive atomic steps in the epitaxial process.

Choi, Sang↗

Probing and controlling oxygen impurity diffusion in h -BN semi-bulk crystals

Combining its unique features of ultrawide bandgap (UWBG) and two-dimensional nature, h-BN has been explored for emerging applications such as deep ultraviolet optoelectronic devices and single photon emitters. One of the unusual applications of h-BN is for solid-state neutron detectors by utilizing the property of high thermal neutron capture cross section of B-10 as well as its UWBG properties. Although a record high detection efficiency of 59% has been attained by h-BN detectors, the understanding/minimization of defects and impurities is still needed to further advance the h-BN material and detector technologies. We report metal organic chemical vapor deposition growth and oxygen (O) impurity diffusion in thick h-BN. The diffusion coefficient (D) of O impurities has been measured via the evolution of an oxygen related emission with the etching depth, providing a value of D of ∼ 2 × 10−13 cm2/s at 1450 °C and supporting the interpretation that oxygen in h-BN is a substitutional donor. A multiple-buffer-layer approach was employed to mitigate to a certain degree the issue of oxygen diffusion from sapphire substrate during growth. It was demonstrated that the performance of h-BN neutron detectors fabricated from the wafer incorporating multiple buffer layers was significantly improved, as manifested by the enhanced thermal neutron detection efficiency. The advancement of the crystal growth technology of h-BN semi-bulk crystals creates applications in optoelectronic and power electronic devices utilizing the UWBG semiconductor properties of h-BN, while high efficiency h-BN neutron detectors have the potential to supplant the traditional He-3 gas detectors in various application areas by offering the obvious advantages of UWBG semiconductor technologies.

Physics↗

Piezoelectric bulk acoustic resonators for dark photon detection

The kinetically mixed dark photon is a simple, testable dark matter candidate with strong theoretical motivation. Detecting the feeble electric field dark photon dark matter produces requires extremely sensitive detectors. Bulk acoustic resonators (BARs), with their exceptionally high-quality phonon modes, are highly sensitive detectors, and have previously leveraged this sensitivity to search for gravitational waves in the MHz to GHz frequency range. The BAR phonons are typically read out by detecting the electric field generated by the BAR materials’ piezoelectricity. Here we show that this piezoelectricity also rewards such detectors sensitivity to dark photon dark matter, as the dark electric field can resonantly excite BAR phonons. A single 10 g piezoelectric BAR in a large, cold, environment can be orders of magnitude more sensitive to the kinetic mixing parameter than any current experiment, with only a month-long exposure and thermally limited backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance optimization of detector electronics for millimeter laser ranging

The front-end electronic circuitry plays a fundamental role in determining the performance actually obtained from ultrafast and highly sensitive photodetectors. We deal here with electronic problems met working with microchannel plate photomultipliers (MCP-PMTs) and single photon avalanche diodes (SPADs) for detecting single optical photons and measuring their arrival time with picosecond resolution. The performance of available fast circuits is critically analyzed. Criteria for selecting the most suitable electronics are derived and solutions for exploiting the detector performance are presented and discussed.

Cova, Sergio↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the µ-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the 555 – 714 µm range with a resolution of R = λ/∆λ = 512 at the 638 µm band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM µ-Spec design is an advancement upon a successful R = 64 µ-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single M=2 grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ∼8 × 10−19 W/√( Hz). We summarize the design, fabrication, and ongoing development of these µ-Spec spectrometers for EXCLAIM.

Carolyn G. Volpert↗