Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Complex permittivity measurements during high temperature recycling of space shuttle antenna window and dielectric heat shield materials

The research performed and the data obtained on candidate space shuttle antenna window and heat shield materials are presented. The measurement technique employs a free-space focused beam microwave bridge for obtaining RF transmission data, and a device which rotates a sample holder which is heated on one side by natural gas-air flames. The surface temperature of each sample is monitored by IR pyrometry; embedded and rear surface thermocouples are also used in obtaining temperature data. The surface of the sample undergoing test is subjected to approximately the same temperature/time profile that occurs at a proposed antenna position on the space shuttle as it re-enters. The samples are cycled through ten of these temperature profiles to determine the recycling effects. Very little change was noted in the materials due to the recycling.

Bassett, H. L.↗

Modeling the Freezing of SN in High Temperature Furnaces

Presently, crystal growth furnaces are being designed that will be used to monitor the crystal melt interface shape and the solutal and thermal fields in its vicinity during the directional freezing of dilute binary alloys, To monitor the thermal field within the solidifying materials, thermocouple arrays (AMITA) are inserted into the sample. Intrusive thermocouple monitoring devices can affect the experimental data being measured. Therefore, one objective of this work is to minimize the effect of the thermocouples on the data generated. To aid in accomplishing this objective, two models of solidification have been developed. Model A is a fully transient, one dimensional model for the freezing of a dilute binary alloy that is used to compute temperature profiles for comparison with measurements taken from the thermocouples. Model B is a fully transient two dimensional model of the solidification of a pure metal. It will be used to uncover the manner in which thermocouple placement and orientation within the ampoule breaks the longitudinal axis of symmetry of the thermal field and the crystal-melt interface. Results and conclusions are based on the comparison of the models with experimental results taken during the freezing of pure Sn.

Brush, Lucien↗

Fluid Dynamics of a Pressure Reducing Inlet

Instruments for the monitoring of hazardous gases in and near the space shuttle collect sample gas at pressures on the order of one atmosphere and analyze their properties in an ultra-high vacuum by means of a quadrupole-mass-spectrometer partial pressure transducer. Sampling systems for such devices normally produce the required pressure reduction through combinations of vacuum pumps, fluid Tees and flow restrictors (e.g. orifices, sintered metal frits or capillaries). The present work presents an analytical model of the fluid dynamics of such a pressure reduction system which enables the calculation of the pressure in the receiver vessal in terms of system parameters known from the specifications for a given system (e.g. rated pumping speeds of the pumping hardware and the diameters of two orifices situated in two branches of a fluid Tee). The resulting formulas will expedite the fine tuning of instruments now under development and the design of later generations of such devices.

Russell, John M.↗

Integrated Microfluidic Gas Sensors for Water Monitoring

A silicon-based microhotplate tin oxide (SnO2) gas sensor integrated into a polymer-based microfluidic system for monitoring of contaminants in water systems is presented. This device is designed to sample a water source, control the sample vapor pressure within a microchannel using integrated resistive heaters, and direct the vapor past the integrated gas sensor for analysis. The sensor platform takes advantage of novel technology allowing direct integration of discrete silicon chips into a larger polymer microfluidic substrate, including seamless fluidic and electrical interconnects between the substrate and silicon chip.

Zhu, L.↗

Bolometric Device Based on Fluxoid Quantization

The temperature dependence of fluxoid quantization in a superconducting loop. The sensitivity of the device is expected to surpass that of other superconducting- based bolometric devices, such as superconducting transition-edge sensors and superconducting nanowire devices. Just as important, the proposed device has advantages in sample fabrication.

Bonetti, Joseph A.↗

Asbestos Exposure Assessment Database

Exposure to particular hazardous materials in a work environment is dangerous to the employees who work directly with or around the materials as well as those who come in contact with them indirectly. In order to maintain a national standard for safe working environments and protect worker health, the Occupational Safety and Health Administration (OSHA) has set forth numerous precautionary regulations. NASA has been proactive in adhering to these regulations by implementing standards which are often stricter than regulation limits and administering frequent health risk assessments. The primary objective of this project is to create the infrastructure for an Asbestos Exposure Assessment Database specific to NASA Johnson Space Center (JSC) which will compile all of the exposure assessment data into a well-organized, navigable format. The data includes Sample Types, Samples Durations, Crafts of those from whom samples were collected, Job Performance Requirements (JPR) numbers, Phased Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM) results and qualifiers, Personal Protective Equipment (PPE), and names of industrial hygienists who performed the monitoring. This database will allow NASA to provide OSHA with specific information demonstrating that JSC s work procedures are protective enough to minimize the risk of future disease from the exposures. The data has been collected by the NASA contractors Computer Sciences Corporation (CSC) and Wyle Laboratories. The personal exposure samples were collected from devices worn by laborers working at JSC and by building occupants located in asbestos-containing buildings.

Arcot, Divya K.↗

The Micro-Arcsecond Metrology Testbed

The Micro-Arcsecond Metrology (MAM) testbed is a ground-based system of optical and electronic equipment for testing components, systems, and engineering concepts for the Space Interferometer Mission (SIM) and similar future missions, in which optical interferometers will be operated in outer space. In addition, the MAM testbed is of interest in its own right as a highly precise metrological system. The designs of the SIM interferometer and the MAM testbed reflect a requirement to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer with sufficient spatial resolution to generate astrometric data with angular resolution at the microarcsecond level. The internal path is to be measured by use of a small metrological laser beam of 1,319-nm wavelength, whereas the position of the starlight fringe is to be estimated by use of a charge-coupled-device (CCD) image detector sampling a large concentric annular beam. For the SIM to succeed, the optical path length determined from the interferometer fringes must be tracked by the metrological subsystem to within tens of picometers, through all operational motions of an interferometer delay line and siderostats. The purpose of the experiments performed on the MAM testbed is to demonstrate this agreement in a large-scale simulation that includes a substantial portion of the system in the planned configuration for operation in outer space. A major challenge in this endeavor is to align the metrological beam with the starlight beam in order to maintain consistency between the metrological and starlight subsystems at the system level. The MAM testbed includes an optical interferometer with a white light source, all major optical components of a stellar interferometer, and heterodyne metrological sensors. The aforementioned subsystems are installed in a large vacuum chamber in order to suppress atmospheric and thermal disturbances. The MAM is divided into two distinct subsystems: the test article (TA), which is the interferometer proper, and the inverse interferometer pseudo-star (IIPS), which synthesizes the light coming from a distant target star by providing spatially coherent wavefronts out of two mirrors, separated by the MAM baseline, that feed directly into two siderostats that are parts of the TA. The two feed mirrors of the IIPS are articulated (in translation and tilt) in order to simulate stars located at different orientations in space, while still illuminating the TA siderostats. The spectrum of the simulated starlight of the IIPS corresponds to that of a blackbody at a temperature of about 3,100 K.

Goullioud, Renaud↗

Control Software for Piezo Stepping Actuators

A control system has been developed for the Space Interferometer Mission (SIM) piezo stepping actuator. Piezo stepping actuators are novel because they offer extreme dynamic range (centimeter stroke with nanometer resolution) with power, thermal, mass, and volume advantages over existing motorized actuation technology. These advantages come with the added benefit of greatly reduced complexity in the support electronics. The piezo stepping actuator consists of three fully redundant sets of piezoelectric transducers (PZTs), two sets of brake PZTs, and one set of extension PZTs. These PZTs are used to grasp and move a runner attached to the optic to be moved. By proper cycling of the two brake and extension PZTs, both forward and backward moves of the runner can be achieved. Each brake can be configured for either a power-on or power-off state. For SIM, the brakes and gate of the mechanism are configured in such a manner that, at the end of the step, the actuator is in a parked or power-off state. The control software uses asynchronous sampling of an optical encoder to monitor the position of the runner. These samples are timed to coincide with the end of the previous move, which may consist of a variable number of steps. This sampling technique linearizes the device by avoiding input saturation of the actuator and makes latencies of the plant vanish. The software also estimates, in real time, the scale factor of the device and a disturbance caused by cycling of the brakes. These estimates are used to actively cancel the brake disturbance. The control system also includes feedback and feedforward elements that regulate the position of the runner to a given reference position. Convergence time for smalland medium-sized reference positions (less than 200 microns) to within 10 nanometers can be achieved in under 10 seconds. Convergence times for large moves (greater than 1 millimeter) are limited by the step rate.

Shields, Joel F.↗

Thioaptamer Diagnostic System (TDS)

AM Biotechnologies, LLC, in partnership with Sandia National Laboratories, has developed a diagnostic device that quickly detects sampled biomarkers. The TDS quickly quantifies clinically relevant biomarkers using only microliters of a single sample. The system combines ambient-stable, long shelf-life affinity assays with handheld, microfluidic gel electrophoresis affinity assay quantification technology. The TDS is easy to use, operates in microgravity, and permits simultaneous quantification of 32 biomarkers. In Phase I of the project, the partners demonstrated that a thioaptamer assay used in the microfluidic instrument could quantify a specific biomarker in serum in the low nanomolar range. The team also identified novel affinity agents to bone-specific alkaline phosphatase (BAP) and demonstrated their ability to detect BAP with the microfluidic instrument. In Phase II, AM Biotech expanded the number of ambient affinity agents and demonstrated a TDS prototype. In the long term, the clinical version of the TDS will provide a robust, flight-tested diagnostic capability for space exploration missions.

Yang, Xianbin↗

On-Orbit, Immuno-Based, Label-Free White Blood Cell Counting System with Microelectromechanical Sensor Technology (OILWBCS-MEMS)

Aurora Flight Sciences, in partnership with Draper Laboratory, has developed a miniaturized system to count white blood cells in microgravity environments. The system uses MEMS technology to simultaneously count total white blood cells, the five white blood cell differential subgroups, and various lymphocyte subtypes. The OILWBCS-MEMS detection technology works by immobilizing an array of white blood cell-specific antibodies on small, gold-coated membranes. When blood flows across the membranes, specific cells' surface protein antigens bind to their corresponding antibodies. This binding can be measured and correlated to cell counts. In Phase I, the partners demonstrated surface chemistry sensitivity and specificity for total white blood cells and two lymphocyte subtypes. In Phase II, a functional prototype demonstrated end-to-end operation. This rugged, miniaturized device requires minimal blood sample preparation and will be useful for both space flight and terrestrial applications.

Edmonds, Jessica↗

Method Development for In-situ Detection of Latent Herpesvirus DNA from Saliva using Nanopore Sequencing

Research toward latent herpesvirus reactivation has been intensively addressed through Space Shuttle and International Space Station (ISS) investigations. This work has provided the understanding that persistent reactivation of herpesviruses from asymptomatic crew can be detected through viral shedding in saliva, urine, and blood. Occasionally, viral reactivation from the latency stage can pose a threat to crew health (clinical manifestation) before, during, and after flight missions. Furthermore, previous work detailing correlations with immunity indicate that monitoring viral reactivation could be implemented to assess potential immune dysfunction. While in-flight monitoring is desirable, there is no well-established procedure or method for real-time evaluations, and research to date has relied on postflight, ground-based analysis. The development of portable molecular technologies like the miniPCR™ (miniPCR Bio) thermal cycler and the MinION™ sequencer (Oxford Nanopore Technologies) have confirmed that real-time monitoring is possible in extreme and low resource environments. These devices, combined with simple sample preparation methods, have been used to demonstrate bacterial identification onboard the ISS, as well as rapid viral detection in remote locations on Earth. The work here builds upon previous molecular advancements onboard the ISS toward the development and validation of a spaceflight-compatible method for viral detection from crew samples. Several herpesviruses can be detected in saliva, which provides a non-invasive means to collect samples for monitoring. While the basis for this method lies in previous spaceflight investigations, key points for method optimization include DNA extraction from saliva, viral primer selection, and bioinformatic processes for data analysis. To increase viral yield, numerous DNA extraction methods have been evaluated and will be discussed in detail. For initial development and testing, varicella-zoster virus (VZV) is being targeted though open reading frame 51 and 63 (ORF51, ORF63), as the replication origin-binding protein is highly expressed during latency. Optimization of the thermal cycling parameters has resulted in the ability to test the entire process. The full method has been tested with both viral VZV DNA standards and saliva spiked with varying concentrations of VZV. Viral sequence data were mapped to the reference sequence using minimap2. Prior to mapping, DNA sequencing reads were filtered for length and quality, barcodes were removed, and alignment identity calculated. Following further assessments, statistics were compared across multiple sequencing experiments and are being used to determine the success of the protocols. Forward work will include the incorporation of herpes simplex virus 1 (HSV-1) and Epstein-Barr virus (EBV) primers as well as the validation of results to the terrestrial qPCR standard assay. Upon full validation of the developed method, saliva will be collected from 20 healthy subjects and spiked with viral DNA. These samples will be split and assayed with the MinION and standard qPCR assay.

Hang N Nguyen↗

Feasibility Study of a Robotic Science Arm on Future Martian Rotorcraft

Science arms are indispensable tools for planetary exploration, allowing vehicles to interact with and manipulate their surroundings in a manner similar to a human field geologist. A majority of the rovers and landers sent to Mars, beginning with Viking I and II in 1976, have made extensive use of these articulated, arm-like devices that allow for sample collection, surface preparation, instrument positioning, and the deployment of ground-contact sensors. Although proven useful, traditional rovers and landers are limited by the rough and difficult terrain of Mars. However, given the successful demonstration of flight on Mars by the Ingenuity helicopter, efforts are underway to outfit larger rotorcraft with science payloads to allow them to explore Mars’ surface and lower atmosphere with significantly more efficiency than land vehicles. Such vehicles could also be designed to work in tandem with landers or rovers. The Mars Science Helicopter (MSH) is a conceptual hexacopter design that is currently under early development by both NASA Ames and JPL. Equipping a vehicle like MSH with a science arm has the potential to further expand its scientific capabilities. This paper approaches the mission and design requirements to equip a science arm on MSH while highlighting the unique technical challenges for robotic arm and science instrument capability. Current plans for MSH development do not include the addition of a robotic arm to the vehicle. However, it is anticipated that future variants of the MSH design might well incorporate such adaptable surface interactive capabilities.

Robotic Science Arm↗

Volumetric micro-injector for capillary electrophoresis

A volumetric microfluidic injector for capillary electrophoresis (CE) for highly repeatable sample injection has been designed and built to eliminate known injection bias in hydrodynamic injection. A defined volume from 1-10 nL or 0.1-100 nL of sample is confined in a defined region of a micro-valve PDMS microfluidic injector chip and electrophoretic potential is applied to drive sample into a separation device such as an embedded fused silica capillary for separation and detection. Using a 75 μm ID capillary, the RSD of an absorbance peak area as low as 1.32% (n=11) is obtained. As a comparison, the time-dependent injection was tested using the same chip which resulted in an inferior repeatability.

Ha, Noel Seunghyun↗

The International Space Station Urine Monitoring System (UMS)

A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.

Feeback, Daniel L.↗

BPSK Demodulation Using Digital Signal Processing

A digital communications signal is a sinusoidal waveform that is modified by a binary (digital) information signal. The sinusoidal waveform is called the carrier. The carrier may be modified in amplitude, frequency, phase, or a combination of these. In this project a binary phase shift keyed (BPSK) signal is the communication signal. In a BPSK signal the phase of the carrier is set to one of two states, 180 degrees apart, by a binary (i.e., 1 or 0) information signal. A digital signal is a sampled version of a "real world" time continuous signal. The digital signal is generated by sampling the continuous signal at discrete points in time. The rate at which the signal is sampled is called the sampling rate (f(s)). The device that performs this operation is called an analog-to-digital (A/D) converter or a digitizer. The digital signal is composed of the sequence of individual values of the sampled BPSK signal. Digital signal processing (DSP) is the modification of the digital signal by mathematical operations. A device that performs this processing is called a digital signal processor. After processing, the digital signal may then be converted back to an analog signal using a digital-to-analog (D/A) converter. The goal of this project is to develop a system that will recover the digital information from a BPSK signal using DSP techniques. The project is broken down into the following steps: (1) Development of the algorithms required to demodulate the BPSK signal; (2) Simulation of the system; and (3) Implementation a BPSK receiver using digital signal processing hardware.

Garcia, Thomas R.↗

Microsampling techniques for infrared spectroscopic analysis of lunar and terrestrial minerals

Microsampling techniques have been developed for infrared analysis of single mineral grains from lunar rocks and dusts, allowing a detailed molecular structure characterization of these complex fine-grained samples. The methods include special devices for isolating single grains, preparing micropellets from the grains, and obtaining in situ microspecular reflectance spectra from grains in polished rock samples. Although specifically developed for the work on lunar samples, the special techniques for single grain infrared analysis were found to be equally useful in studies of complex terrestrial mineral samples. For example, infrared microanalysis has contributed substantially in solving problems concerned with our natural resources, such as the structural characterization of minerals from commercial iron ores, marine deposits, coal, and fly ash derived from coal.

Estep, P. A.↗

Particulate Removal Using a CO2 Composite Spray Cleaning System

The Planetary Protection surface cleanliness requirements for potential Mars Sample Return hardware that would come in contact with Martian samples may be stricter than previous missions. The Jet Propulsion Laboratory has developed a new technology that will enable us to remove sub-micron size particles from critical hardware surfaces. A hand-held CO2 composite cleaning system was tested to verify its cleaning capabilities. This convenient, portable device can be used in cleanrooms for cleaning after rework or during spacecraft integration and assembly. It is environmentally safe and easy to use. This cleaning concept has the potential to be further developed into a robotic cleaning device on a Mars Lander to be used to clean sample acquisition or sample handling devices in situ. Contaminants of known sizes and concentrations, such as fluorescent microspheres and spores were deposited on common spacecraft material surfaces. The cleaning efficiency results will be presented and discussed.

carbon dioxide↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗