Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Soil Temperature Sensor Data, May - December 2024, Five sites in Knoxville, Tennessee

This dataset contains surface soil temperature measurements from five urban parks in Knoxville: Cumberland Estates Park (CE), Socially Equal Energy Efficient Development (SD), West View Park (WV), Victor Ashe Park (VA), and West Hills Park (WH). The dataset comprises 29 Excel (.xlsx) and Comma-Separated Values (.csv) files documenting soil temperature recorded by six HOBO Pendant MX Water Temperature Data Loggers at each site, except for CE, which has five sensors. Each logger was installed at a depth of 10 inches and positioned approximately 3 to 6 feet from the weather station at each site. To open both csv and xlsx files, users can utilize spreadsheet applications such as Microsoft Excel, Google Sheets, LibreOffice Calc, and Apple Numbers. This dataset is part of a broader study examining the effects of soil moisture and plant evapotranspiration on ambient temperature and relative humidity across multiple urban parks in Knoxville, Tennessee.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Enabling the Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

An important need for coal fired power plants is the ability to monitor multiple systems with ease and accuracy. Common implementations of these monitoring systems come with drawbacks due to the nature of coal fired power plants. Harsh environments, High Temperatures, and lots of RF (Radio Frequency) noise can create issues for accurately recording and transmitting data across wireless signals. In addition, as renewable energy sources come online, existing fossil fueled plants will need to operate more flexibly with their maintenance schedules outside of standard conditions. Therefore, additional sensing and control mechanisms need placed in existing plants to provide operators with more information such that maintenance decisions can be made well in advance of failures. A solution to this problem is the Next Generation of Smart Sensors, which leverages the power of 5G cellular signals and machine learning to overcome the myriad of problems with current implementations

20 FOSSIL-FUELED POWER PLANTS↗

Advanced Intelligent Sensor Development and Demonstration for Future Distribution Systems with High Penetration DERs

The nation’s electric grid is evolving to supply the electricity needed for economic growth, health, and quality of life. As the DOE has pointed out “Old Tools Won’t Solve New Problems” This project conceived, designed, built, and demonstrated a new tool that promises to make the emerging grid dependable at a lower cost. The tool is a smart sensor with the sensitivity and the bandwidth to measure actionable information about grid health that was unmeasurable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tritium Betavoltaic Powered Sensor Platforms: Power Augmentation with Scintillating Particles

Betavoltaics (BV) are long-life power sources that typically convert beta particle radiation into electricity. Largely, the radioactive decays within the source go unharvested by the device. This work seeks to augment the power generation of BV devices by integration of scintillating particles within the radiative getter to convert beta emission which would otherwise not leave the getter into usable light for power generation. Silica-covered barium fluoride scintillating particles were integrated into a tritiated water getter. Power generation was increased from 100s of nW to µW levels with the addition of 0.2 wt. % particles into the getter. Nanowatt-scale sensor platforms were demonstrated with the µW BV devices and the maximum possible lifetime of such platforms was estimated. As this technique enables higher power density BV devices from conventional Si semiconductors (compared to wider bandgap BVs), the further implementation may lower the barrier-to-deployment of these long-life power/sensor platforms.

42 ENGINEERING↗

Dynamic Heat Flow and Current Distribution Analysis in the Bottom Anode of an Electric Arc Furnace Using Fiber-Optic Sensors

A reliable method for monitoring bottom anode wear during DC Electric Arc Furnace (DC-EAF) operation is of critical importance for safe and efficient steel production. Underestimation of bottom wear poses a serious safety risk that must be avoided, while overestimation of bottom wear also poses challenges, as premature anode replacement is expensive and affects EAF productivity. Previously, we demonstrated that fiber-optic sensors can be successfully deployed to create a spatially distributed temperature map to monitor the health of the anode. The present work explores the heat flow and current density distribution in bottom anode pins to predict bottom wear, steel penetration events, and monitor refractory erosion. Small dynamic variations in pin temperature induced by joule heating during arcing also provide a means to observe local current flows in each pin. When mapped, these measurements provide a real-time view of the non-uniform and dynamic current flow in the bottom anode during EAF operation that can affect bottom wear.

Bottom Anode↗

Pyrrole‐Imine Macrocycle: Self‐Organizing Cross‐Reactive Anion Receptor and Sensor

Self-organizing macrocyclic receptor-sensors for phosphorus oxyanions, phosphates, and phosphonates comprising imine moieties were prepared by condensation of dipyrrolylmethane dicarbaldehyde with diethylene triamine. The incorporation of flexible ethylene moieties endows the macrocycle with unprecedented flexibility and ability to accommodate numerous phosphorus oxyanions from orthophosphate to large anions such as ATP or phosphonate glyphosate. The anion binding was elucidated by NMR titrations, low-temperature NMR, and NOESY NMR. The incorporation of dansyl fluorophore enables sensing of anions using the fluorescence signal, whereas the changes in fluorescence intensity, width of the fluorescence band, and position of the maxima are analyte-specific and useful in recognition and identification of eleven different P-oxyanions in water. The affinity (K assoc ) for Na + salts was H 2 PO 4 − ≈ Methylphosphonate > H 2 P 2 O 7 2− > Phenylphosphonate- > Glyphosate 2− > AMP 2− > ADP 2− > ATP 2− . Interestingly, phosphonates, including methylphosphonate and glyphosate anions, were also found to display a strong affinity (K assoc ∼10 6 M −1 ) while halides, nitrate, carbonates, or hydrogen sulfate did not show a significant affinity. The determined fluorescence spectral parameters were used to classify the 12 analytes (11 anions and water) using Linear Discriminant Analysis (LDA). Quantification was performed using LDA and Support Vector Machine (SVM), and the phosphonate concentrations in unknown samples were determined with an error of 3.5% or lower.

anions↗

Signatures of Thermal and Electrical Crosstalk in a Microwave Multiplexed Hard X-ray Transition Edge Sensor Array

We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a 24-pixel hard X-ray spectrometer array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated with insufficient thermalization, and rare but larger in magnitude electrical crosstalk between specific perpetrator-victim pixel combinations, potentially due to defects in the bias wiring or microwave multiplexing circuit. We use a method based on group-triggering and averaging to isolate the crosstalk response despite only having access to X-ray photon illumination uniform across the entire array. This allows us to identify thermal and electrical crosstalk between pixel pairs in repeated measurements to the level of 1 part in 1000 or better. In the array under study, the magnitude of observed crosstalk is small but comparable to the resolving power of this pixel design (E/Delta E similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$E/\Delta {}E \sim$$\end{document} 1000 at 20 keV) and so potentially responsible for a degradation in energy resolution of the array at high incident photon rates. Having proven the methods to identify and quantify crosstalk in our setup, we can now consider mitigations.

Triamkitsawat, Panthita↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Distributed strain sensing using Bi-metallic coated fiber optic sensors embedded in stainless steel

Silica fiber optic sensors are resistant to corrosive environments and high temperatures, making them attractive candidates for harsh conditions found in nuclear and aerospace industries. Moreover, fibers can be deployed remotely for continuous measuring of spatially distributed temperatures and strains. Here, this study investigated embedding a Ni/Cu bi-metallic coated fiber in a stainless-steel 316 (SS316) matrix using laser powder bed fusion towards functionalizing metal components for site-specific health monitoring. The embedded fiber was continuously interrogated during controlled heating to 1000°C. The measured fiber strains were similar to the expected differential thermal strains between the fiber and the SS316 matrix, until divergent behavior was observed at temperatures >500°C. No debonding at the matrix–coating–fiber interfaces was observed during microscopy, but significant interactions between the coatings and matrix resulted in diffusion-driven chemistry variations and Kirkendall void formation. Applying the strain-lag theory revealed plastic behavior in the Ni coating at temperatures >500°C, limiting the strain transfer to the fiber at higher temperatures. It was estimated that the elastic modulus in the Ni coating had decreased from ~200 GPa at room temperature to below 40 GPa, starting at 600°C. The low elastic modulus above 600°C is within the margin of what the tangent modulus would be in the case of bilinear isotropic hardening. Regardless of the divergent strain transfer at higher temperatures, the fiber was exposed to the equivalent of 1.9 % engineering strain at 1000°C, but measured only a 0.7 % engineering strain due to the poor strain transfer. Although compensating for the plastic behavior of Ni proved challenging, the bonding of a brittle silica fiber to a metal matrix surviving to 1000°C invites potential iterations on coating material for future application. For example, the embedded fiber is sufficient for acoustic energy transfer, realizing high temperature distributed acoustic sensing.

36 MATERIALS SCIENCE↗

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu↗

An engineered lactate oxidase based electrochemical sensor for continuous detection of biomarker lactic acid in human sweat and serum

Lactate levels in humans reveal intensity and duration of exertion and provide a critical readout for the severity of life-threatening illnesses such as pediatric sepsis. Using the lactate oxidase enzyme (Lox) from Aerococcus viridians, we demonstrated its functionality for lactate electrochemical sensing in physiological fluids in a lab setting. The structure and dynamics of LOx were validated by crystallography, X-ray scattering, and hydroxyl radical protein footprinting. This provided a validated protein template for understanding and designing an enzyme-based electrochemical sensing elements. Using this template, LOx enzyme variants were generated and compared. Comparison of the variants demonstrates that one exhibits effective lactate sensing at significantly reduced operating voltages. Additionally, we demonstrate that the four hexahistidine-tags on each enzyme tetramer are sufficient for immobilization to create a durable, functional sensor, with no need for a covalent attachment, enabling self-immobilization and eliminating the need for additional immobilization steps. The functionality of the LOx enzyme variants was verified at physiological lactate concentrations in both human serum (0–4 mM) and artificial sweat (0–100 mM) using 3-electrode setups for analysis of the three variants in parallel. Accuracy of measurement in both artificial sweat and human serum were high. Employing a microfluidic flow cell, we successfully monitored varying lactate levels in physiological fluids continuously over a 2h period. Overall, this optimized LOx enzyme, which self-immobilizes onto gold sensing electrodes, facilitates efficient and reliable lactate detection and continuous monitoring at reduced operating voltages suitable for further development towards commercial use.

60 APPLIED LIFE SCIENCES↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Robust cooperative control strategy for a platoon of connected and autonomous vehicles against sensor errors and control errors simultaneously in a real-world driving environment

In a real-world driving environment, a platoon of connected and autonomous vehicles (CAVs) is subject to many internal and external disturbances, resulting in uncertain vehicle dynamics. In general, the disturbances can be categorized into two types: disturbances due to vehicle sensor errors (e.g., GPS error) and disturbances due to vehicle control errors (e.g., actuator delay). In the literature, many control strategies have been proposed to improve the robustness of the CAV platoon against uncertain vehicle dynamics induced by these disturbances. However, most of these strategies only consider one type of disturbance and cannot tackle both types of disturbances simultaneously. Furthermore, they are designed to maximize the benefits of each vehicle in the platoon independently, which can deteriorate the performance of the platoon. Here, to address these problems, this study proposes a robust cooperative control (RCC) strategy to maneuver the vehicles in the platoon cooperatively to counteract the impacts of both types of disturbances. The RCC strategy is developed based on a minimax problem, where the maximization subproblem seeks to find the worst inputs for the uncertainty terms in the vehicle dynamics equation to minimize the platoon performance, while the minimization subproblem seeks to find the optimal control decisions for all subsequent vehicles to maximize the platoon performance in the worst case. To solve the minimax problem, this study proposes a globally convergent solution algorithm. It can solve the minimax problem very efficiently to enable real time deployment of the RCC strategy. Numerical application indicates that compared to the existing methods, the RCC strategy can dramatically improve the robustness of the CAV platoon against the uncertain vehicle dynamics induced by both vehicle state detection errors and vehicle control errors. Therefore, it can maneuver the CAV platoon safely and efficiently in a real-world driving environment.

33 ADVANCED PROPULSION SYSTEMS↗

A Performant, Scalable Processing Pipeline for High‐Quality and FAIR Environmental Sensor Data

High-resolution environmental monitoring is necessary to record, understand, and predict biogeochemical and ecological changes particularly in coastal systems but brings significant challenges in processing and making rapidly available the resulting data. The COMPASS-FME project established a network of coastal observational sites across the Chesapeake Bay and western Lake Erie regions extensively instrumented with soil, vegetation, and weather sensors logging data every 15 min. Our data processing framework, written in R and completely open source, prioritizes rapid model-experiment iteration and makes biogeochemical data rapidly available for quality assurance/quality control, analysis, and model ingestion. This pipeline is distinguished by a standardized and modular approach to data curation, extensive metadata and documentation, and its high performance. These attributes combine to make biogeochemical data rapidly accessible across COMPASS-FME and the broader community. Flexible, powerful, and reproducible approaches to handling high-volume environmental data are crucial for accelerating biogeosciences research.

Pennington, Stephanie C. [Pacific Northwest Nation↗

Long-baseline quantum sensor network as dark matter haloscope

Ultralight dark photons constitute a well-motivated candidate for dark matter. A coherent electromagnetic wave is expected to be induced by dark photons when coupled with Standard-Model photons through kinetic mixing mechanism, and should be spatially correlated within the de Broglie wavelength of dark photons. Here we report the first search for correlated dark-photon signals using a long-baseline network of 15 atomic magnetometers, which are situated in two separated meter-scale shield rooms with a distance of about 1700 km. Both the network’s multiple sensors and the shields large size significantly enhance the expected dark-photon electromagnetic signals, and long-baseline measurements confidently reduce many local noise sources. Using this network, we constrain the kinetic mixing coefficient of dark photon dark matter over the mass range 4.1 feV-2.1 peV, which represents the most stringent constraints derived from any terrestrial experiments operating over the aforementioned mass range. Our prospect indicates that future data releases may go beyond the astrophysical constraints from the cosmic microwave background and the plasma heating.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗