Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Processing Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Space shuttle synthetic aperture radar

Results of a feasibility study to investigate a digital signal processor for real-time operation with a synthetic aperture radar system aboard the space shuttle are presented. Pertinent digital processing theory, a description of the proposed system, and size, weight, power, scheduling, and development estimates are included.

Source record↗

Unprecented syntonization and syncronization accuracy via simultaneous viewing with GPS receivers: Construction characteristics of an NBS/GPS receiver

The National Bureau of Standards/Global Positioning System (NBS/GPS) receiver is discussed. It is designed around the concept of obtaining high accuracy, low cost time and frequency comparisons between remote frequency standards and clocks with the intent to aid international time and frequency coordination. Preliminary tests of this comparison technique between Boulder, CO and Washington, D.C indicate the ability to do accurate time transfer to better that 10 ns, and frequency measurements to better than 1 part in 10 to the 14th power. The hardware and software of the receiver is detailed. The receiver is fully automatic with a built-in 0.1 ns resolution time interval counter. A microprocessor does data processing. Satellite signal stabilities are routinely at the 5 ns level for 15 s averages, and the internal receiver stabilities are at the 1 ns level.

Davis, D. D.↗

Roundoff noise analysis for digital Doppler processors in radar scatterometers

The noise due to finite word length effects for digital Doppler processors (DPP) in radar scatterometers, is analyzed. The roundoff noise-to-signal ratio in the measurement of the radar return signal power is derived. Computer simulations which validate the analytical results are presented. The results can be used in tradeoff studies of hardware design such as number of bits required at each processing stage. The results are used in the design of a DPP for the NASA scatterometer planned to be launched in 1990.

Chi, Chong-Yung↗

Virtual acoustic displays

A 3D auditory display can potentially enhance information transfer by combining directional and iconic information in a quite naturalistic representation of dynamic objects in the interface. Another aspect of auditory spatial clues is that, in conjunction with other modalities, it can act as a potentiator of information in the display. For example, visual and auditory cues together can reinforce the information content of the display and provide a greater sense of presence or realism in a manner not readily achievable by either modality alone. This phenomenon will be particularly useful in telepresence applications, such as advanced teleconferencing environments, shared electronic workspaces, and monitoring telerobotic activities in remote or hazardous situations. Thus, the combination of direct spatial cues with good principles of iconic design could provide an extremely powerful and information-rich display which is also quite easy to use. An alternative approach, recently developed at ARC, generates externalized, 3D sound cues over headphones in realtime using digital signal processing. Here, the synthesis technique involves the digital generation of stimuli using Head-Related Transfer Functions (HRTF's) measured in the two ear-canals of individual subjects. Other similar approaches include an analog system developed by Loomis, et. al., (1990) and digital systems which make use of transforms derived from normative mannikins and simulations of room acoustics. Such an interface also requires the careful psychophysical evaluation of listener's ability to accurately localize the virtual or synthetic sound sources. From an applied standpoint, measurement of each potential listener's HRTF's may not be possible in practice. For experienced listeners, localization performance was only slightly degraded compared to a subject's inherent ability. Alternatively, even inexperienced listeners may be able to adapt to a particular set of HRTF's as long as they provide adequate cues for localization. In general, these data suggest that most listeners can obtain useful directional information from an auditory display without requiring the use of individually-tailored HRTF's.

Wenzel, Elizabeth M.↗

Imaging Spectrometer With Liquid-Crystal Tunable Filter

Imaging spectrometer constructed from charged-coupled-device video camera; liquid-crystal tunable filter (LCTF) placed in front of camera lens; and associated digital and analog control, signal-processing, and data-processing circuits. To enable operation of instrument in specific application for which designed (balloon flights in cold weather), camera and LCTF surrounded by electric heating pad. Total operating power, excluding that consumed by heating pad, 16 W. Instrument weighs 4.5 kg.

Chrien, Thomas G.↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Solar Cycle Fine Structure and Surface Rotation from Ca II K-Line Time Series Data

Analysis of three and a half decades of data from the NSO/AFRL/Sac Peak K-line monitoring program yields evidence for four components to the variation: (a) the solar cycle, with considerable fine structure and a quasi-periodicity of 122.4 days; (b) a stochastic process, faster than (a) and largely independent of it, (c) a quasi-periodic signal due to rotational modulation, and of course (d) observational errors (shown to be quite small). Correlation and power spectrum analyses elucidate periodic and aperiodic variation of these chromospheric parameters. Time-frequency analysis is especially useful for extracting information about differential rotation, and in particular elucidates the connection between its behavior and fine structure of the solar cycle on approximately one-year time scales. These results further suggest that similar analyses will be useful at detecting and characterizing differential rotation in stars from stellar light-curves such as those being produced at NASA's Kepler observatory.

Scargle, Jeff↗

Solid-State Detector for Trace Materials

Detector for trace chemicals senses as few as 10 to the 12th power molecules of given material on surface. Contains no moving parts, amenable to large-scale integration, and operates at room temperature. Potential applications in industrial process control and in environmental analysis. Characteristic signals indicate presence of certain chemicals.

Lambe, J. J.↗

Advanced sensors and instrumentation

NASA is currently investigating the readiness of Advanced Sensors and Instrumentation to meet the requirements of new initiatives in space. The following technical objectives and technologies are briefly discussed: smart and nonintrusive sensors; onboard signal and data processing; high capacity and rate adaptive data acquisition systems; onboard computing; high capacity and rate onboard storage; efficient onboard data distribution; high capacity telemetry; ground and flight test support instrumentation; power distribution; and workstations, video/lighting. The requirements for high fidelity data (accuracy, frequency, quantity, spatial resolution) in hostile environments will continue to push the technology developers and users to extend the performance of their products and to develop new generations.

Calloway, Raymond S.↗

RF Device for Acquiring Images of the Human Body

A safe, non-invasive method for forming images through clothing of large groups of people, in order to search for concealed weapons either made of metal or not, has been developed. A millimeter wavelength scanner designed in a unique, ring-shaped configuration can obtain a full 360 image of the body with a resolution of less than a millimeter in only a few seconds. Millimeter waves readily penetrate normal clothing, but are highly reflected by the human body and concealed objects. Millimeter wave signals are nonionizing and are harmless to human tissues when used at low power levels. The imager (see figure) consists of a thin base that supports a small-diameter vertical post about 7 ft (=2.13 m) tall. Attached to the post is a square-shaped ring 2 in. (=5 cm) wide and 3 ft (=91 cm) on a side. The ring is oriented horizontally, and is supported halfway along one side by a connection to a linear bearing on the vertical post. A planar RF circuit board is mounted to the inside of each side of the ring. Each circuit board contains an array of 30 receivers, one transmitter, and digitization electronics. Each array element has a printed-circuit patch antenna coupled to a pair of mixers by a 90 coupler. The mixers receive a reference local oscillator signal to a subharmonic of the transmitter frequency. A single local oscillator line feeds all 30 receivers on the board. The resulting MHz IF signals are amplified and carried to the edge of the board where they are demodulated and digitized. The transmitted signal is derived from the local oscillator at a frequency offset determined by a crystal oscillator. One antenna centrally located on each side of the square ring provides the source illumination power. The total transmitted power is less than 100 mW, resulting in an exposure level that is completely safe to humans. The output signals from all four circuit boards are fed via serial connection to a data processing computer. The computer processes the approximately 1-MB data set into a three-dimensional image in a matter of seconds. The innovation is to configure the receiver array in a ring topology surrounding the scanned object. The ring is then scanned vertically to cover the necessary two-dimensional surface. This fabrication of the ring is made possible by using planar antenna and circuit technology. A planar circuit board serves as a medium for both antennas and signal processing components. Using this technique, parts counts are kept low, and the cost per element is a small fraction of a waveguide-based system.

Gaier, Todd C.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Relativistic Astrophysics in Black Hole and Low-Mass Neutron Star Binaries LTSA98

My group, in close collaboration with Dr. Zhang's group at University of Alabama-Huntsville, have been systematically analyzing and re-analyzing a substantial amount of archival data from previous and ongoing X-ray missions, in order to study possible relativistic effects around stellar-mass black holes and neutron stars. Our effort has been focused primarily on the data from the Rossi X-ray Timing Explorer. We carefully studied interesting quasi-periodic X-ray variability in newly discovered black hole candidates (XTE J1859+226 and XTE J1550-564), which, as we had proposed earlier, could be caused by general relativistic process (e.g., frame dragging) around the central black hole. We also discovered an intriguing temporal correlation between X-ray photons at different energies that is associated with the quasi-periodic signals of interest. The results provided new insights into the physical origin of the phenomena. Furthermore, we studied the spectral lines of black hole candidates which provide another avenue for studying general relativistic processes around black holes. The lines-may originate in the relativistic jets (which could be powered by the spin of the black hole) or in the disk around the black hole, as in the cases of 4U 1630-47 and GX 339-4 (two well-known black hole candidates), and may thus be distorted or shifted due to relativistic effects. Of course, neutron star systems were not forgotten either. After examining the properties of newly discovered fast quasi-periodic variability (at kiloHertz) associated with such systems, we proposed a relativistic model to explain the origin of the signals. We have also started to use new great observatories in orbit (such as Chandra and XMM-Newton) to observe the sources that are of interest to us. Finally, interesting results were also been obtained from our collaborations with other groups who are interested in some of the same objects. Such collaborative efforts have greatly enhanced the project and will likely continue in the future.

Cui, Wei↗

Mesogranulation as A Distinct Scale of Convection in the Sun

We present evidence for the existence of mesogranulation as a scale of convection distinct from granulation and supergranulation through analysis of full-disk Doppler velocity images of the Sun collected by the Michelson Doppler Imager (MDI) aboard the NASA/ESA Solar and Heliospheric Observatory (SOHO). Our analysis procedures isolate nearly steady flows in the solar photosphere and yield power spectra of convection for spherical harmonic degrees up to I = 1000. Each spectrum exhibits an obvious supergranulation peak at I approximately 130 and a broad secondary peak at I approximately 600 with a distinct break in the spectrum between these peaks at I approximately 300. We believe that this secondary peak is a signature of mesogranulation with typical cell diameters of about 7 Mm. Our standard analysis procedure is to first remove the p-mode oscillation signal by averaging individual Dopplergrams over 17-minute intervals. Next, by fitting to standard functional forms we remove Doppler signals due to the motion of the spacecraft, the convective blueshift, solar rotation including differential rotation, and the meridional circulation in order to produce Dopplergrams dominated by convective motions. By mapping these processed images onto heliographic coordinates and projecting onto spherical harmonics, we produce a power spectrum of solar convection for each 17-minute period. We construct synthetic images and pass them through the same analysis procedure in order to determine the actual solar convection spectrum that reproduces the analyzed results. We find that a small but increasing percentage of high-degree convective power is lost in the analysis as we approach the limit of resolution of the detector but'that the broad, mesogranulation peak at I approximately 600 must be included in the convection spectrum of the synthetic images.

Bachmann, Kurt T.↗

Hue-saturation-intensity split-spectrum processing of Seasat radar imagery

Characteristics of terrain features in orbital radar imagery are investigated on the basis of radar physics and the human visual system. Signal scattering, the dominant factor in radar imagery, is caused by look angle and relief displacement. Power spectra characteristics are explored, noting that surface scattering dominates the low frequencies and slope significantly affects the high frequency tone variations. The maximum human visual response has been identified for achromatic scenes as 7 cycles per degree, whereas in radar imagery the low frequency half-power point occurs near 2.5 cycles/deg. Image feature size at a scale of 1:500,000 has been calculated for the maximum human response at 1.25 km. A hue-saturation-intensity transformation is presented for displaying two or three data sets on the same image and is demonstrated for Seasat SAR imagery. The transformation is shown to restore low spatial frequencies to the SAR imagery in order to identify terrain features which would otherwise not be visually discernible.

Daily, M.↗

Radar optimization for sea surface and geodetic measurements

The efficient estimation of geoid and sea state parameters is discussed, and the optimum processing structures, including maximum likelihood estimators, and their accuracy limits are given for a model. The model accounts for random surface reflectivity, sea height, and additive noise, and allows for arbitrary radar system parameters, based on the assumption the received signal is a sample function of a normal random process. The integral equation associated with the Gaussian signal in Gaussian noise inference problem was solved. It is shown that the optimum processing is generally a mixture of coherent and incoherent integrations which may be viewed as a weighted summation of received power of the match-filtered received data. When estimates are correlated, the strongest correlation appears between geoid and asymmetry estimates, and between wave height standard deviation and reflectivity estimates.

Harger, R. O.↗

Data acquisition and analysis in the DOE/NASA Wind Energy Program

Four categories of data systems, each responding to a distinct information need are presented. The categories are: control, technology, engineering and performance. The focus is on the technology data system which consists of the following elements: sensors which measure critical parameters such as wind speed and direction, output power, blade loads and strains, and tower vibrations; remote multiplexing units (RMU) mounted on each wind turbine which frequency modulate, multiplex and transmit sensor outputs; the instrumentation available to record, process and display these signals; and centralized computer analysis of data. The RMU characteristics and multiplexing techniques are presented. Data processing is illustrated by following a typical signal through instruments such as the analog tape recorder, analog to digital converter, data compressor, digital tape recorder, video (CRT) display, and strip chart recorder.

Neustadter, H. E.↗

Refinement and application of acoustic impulse technique to study nozzle transmission characteristics

An improved acoustic impulse technique was developed and was used to study the transmission characteristics of duct/nozzle systems. To accomplish the above objective, various problems associated with the existing spark-discharge impulse technique were first studied. These included (1) the nonlinear behavior of high intensity pulses, (2) the contamination of the signal with flow noise, (3) low signal-to-noise ratio at high exhaust velocities, and (4) the inability to control or shape the signal generated by the source, specially when multiple spark points were used as the source. The first step to resolve these problems was the replacement of the spark-discharge source with electroacoustic driver(s). These included (1) synthesizing on acoustic impulse with acoustic driver(s) to control and shape the output signal, (2) time domain signal averaging to remove flow noise from the contaminated signal, (3) signal editing to remove unwanted portions of the time history, (4) spectral averaging, and (5) numerical smoothing. The acoustic power measurement technique was improved by taking multiple induct measurements and by a modal decomposition process to account for the contribution of higher order modes in the power computation. The improved acoustic impulse technique was then validated by comparing the results derived by an impedance tube method. The mechanism of acoustic power loss, that occurs when sound is transmitted through nozzle terminations, was investigated. Finally, the refined impulse technique was applied to obtain more accurate results for the acoustic transmission characteristics of a conical nozzle and a multi-lobe multi-tube supressor nozzle.

Salikuddin, M.↗

Roundoff noise analysis for digital signal power processors using Welch's power spectrum estimation

The noise due to finite-word-length effects is analyzed for digital-signal power processors using Welch's power-spectrum estimation technique to measure the power of Gaussian random signals over a frequency band of interest. The input of the digital signal processor contains a finite-length time interval in which the true Gaussian signal is contaminated by Gaussian noise. The roundoff noise-to-signal ratio in the measurement of the signal power is derived, and computer simulations which validate the analytical results are presented. These results can be used in tradeoff studies of hardware design, such as the number of bits required at each processing stage. The results presented in this paper are currently being used in the design of a digital Doppler processor (Chi et al., 1986) for a radar scatterometer.

Chi, Chong-Yung↗