Search NASA⌕ Search

SEARCH · Search NASA

Results for “Site occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

HIVE™ [SWR-19-36]

The HIVE™ platform is a mobility services simulation platform developed to provide insight on the energy, infrastructure, service, and economic outcomes of various mobility as a service (MaaS) options. The HIVE platform takes a set of spatiotemporal travel origin-destination pairs and simulates the operation of a predefined mobility service fleet, incorporating request pooling, and various operational and charging behaviors. Hive specializes at modeling fleets of automated electric vehicles (AEVs) and can be used to site and size direct current fast charge (DCFC) stations and measure grid impacts of large-scale AEV fleets serving real-world MaaS trip demand (similar to taxis, Uber, Lyft, etc.). Potential outcomes from a Hive simulation include level of service, total vehicle miles traveled (VMT), deadheading (zero passenger) miles, simultaneous and total energy loads, average occupancy, and more. Hive is developed to generalize to new regions and can be customized to handle many scenarios and operating conditions.

Rames, Clement↗

Competing Interests and Creating Value - Balancing Durable and Enforceable Institutional Controls with Beneficial Reuse - 20320

US DOE LM has various real property interests at the 100 sites within its current portfolio, with an anticipated total of 127 sites within the next 5 years. Each site has its own narrative with respect to the real property assets. Since the regulatory time frame for long-term surveillance and maintenance activities at some sites can be in perpetuity, durable and effective instruments and documentation are necessary to support LM's unique mission as a federal land manager and steward. More than half of the sites currently in LM's inventory do not allow unrestricted use, and institutional controls (ICs) are required to limit human and environmental exposures to residual contamination. LM's Asset Management program balances protection of human health and the environment with a goal of optimizing its land portfolio through mitigation of risk, limiting liability, and creating value, whether tangible or intangible, in these types of assets. The IC layering strategy utilizes multiple types, restrictions, and legal authorities to protect human health and the environment. This layering strategy influences the transition of these properties into LM's portfolio to assess potential beneficial reuses. The LM's beneficial reuse program aims to repurpose former contaminated sites to restore the environment, protect the public health, revitalize communities, and spur economic growth. LM strives to create value in a perceived valueless asset and reevaluates and revisits the potential opportunities for these sites as long-term surveillance and maintenance activities are performed and objectives are achieved. Beneficial reuse also promotes protectiveness by ensuring activities are compatible with long-term maintenance and protection of public health and the environment as well as ensuring activities are environmentally sound by retaining good stewardship of natural resources. LM has recently revised both the Institutional Control Program Guidance and its Beneficial Reuse Management Plan to integrate the issues of land use with ICs, creating value in these impaired assets. This paper presents the following topics: (1) a general overview of LM's IC and beneficial reuse programs; (2) the unique aspects of each of these programs as a result of the multiple regulatory requirements and programs that affect LM sites; (3) case studies of LM sites to show examples of how LM created value while complying with the ICs and layering strategies; and (4) the most common challenges to beneficial reuses at LM sites and potential options for value creation in impaired assets. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ecological information and approaches needed for risk communication dialogs for acute or chronic environmental crises

Scientists, social scientists, risk communicators, and many others are often thrust into a crisis situation where they need to interact with a range of stakeholders, including governmental personnel (tribal, U.S. federal, state, local), local residents, and other publics, as well as other scientists and other risk communicators in situations where information is incomplete and evolving. This paper provides: (1) an overall framework for thinking about communication during crises, from acute to chronic, and local to widespread, (2) a template for the types of ecological information needed to address public and environmental concerns, and (3) examples to illustrate how this information will aid risk communicators. The main goal is providing an approach to the knowledge needed by communicators to address the challenges of protecting ecological resources during an environmental crisis, or for an on-going, chronic environmental issue. To understand the risk to these ecological resources, it is important to identify the type of event, whether it is acute or chronic (or some combination of these), what receptors are at risk, and what stressors are involved (natural, biological, chemical, radiological). For ecological resources, the key information a communicator needs for a crisis is whether any of the following are present: threatened or endangered species, species of special concern, species groups of concern (e.g., neotropical bird migrants, breeding frogs in vernal ponds, rare plant assemblages), unique or rare habitats, species of commercial and recreational interest, and species/habitats of especial interest for medicinal, cultural, or religious activities. Communication among stakeholders is complicated with respect to risk to ecological receptors because of differences in trust, credibility, empathy, perceptions, world view valuation of the resources, and in many cases, a history of misinformation, disinformation, or no information. Exposure of salmon spawning in the Columbia River to hexavalent chromium from the Hanford Site is used as an example of communication challenges with different stakeholders, including Native Americans with Tribal Treaty rights to the land.

54 ENVIRONMENTAL SCIENCES↗

Utilization of Geographic Information System in Lunar Mapping

Substantial digital remote sensing, lunar orbital photography, Earth-based remote sensing, and mapping of a variety of surficial lunar phenomena have occurred since the advent of the Space Age. This has led to a bewildering and quite disparate collection of archival sources insofar as this digital data and its cartographic representation can be found within many countries of the world. The importance of this mapping program in support of human expansion onto our nearest planetary neighbor has been recognized. A series of small scale maps of the Moon at 1 km to 1 cm, done with the support of Geographic Information System (GIS), would serve decision makers well in the process of accessing the development of manned occupance of the Moon. Maps and the data that they are derived from are the primary way in which people explore new environments and use previously discovered data to increase the bounties of any exploration. The inherent advantage of GIS is that it would allow immediate online access on the Moon of topographically represented data with analysis either on site or from Earth.

Mardon, A. A.↗

Data-driven evaluation of HVAC operation and savings in commercial buildings

Commercial buildings consumed 36% of electricity, or 1.35 trillion kWh, in the United States in 2017, and almost 30% of this energy was wasted. Much of this loss can be attributed to inefficient heating ventilation and air con­ditioning (HVAC) systems. By improving the operational conditions of HVAC, significant savings can be achieved. However, most buildings and building equipment do not use costly sub-meters to monitor and address performance issues, and on-site auditing can be expensive and insufficient. Alternatively in this study, we propose a data-driven method to identify savings opportunities using only whole building meter data and without setting foot in the building. For this purpose, we introduced two algorithms that virtually quantify the value of a thermostat setpoint setback and HVAC rescheduling. Additionally, we developed novel methods for detecting occupancy patterns and quantifying the baseload of the HVAC operation. Using a clustering algorithm, we identified those buildings for which HVAC savings was significant and further categorized the buildings based on their potential for savings. A population study of over 432 commercial buildings demonstrated a median percentage energy savings of 1.6% from a baseload reduction and 2.1% from HVAC rescheduling. Additionally, results indicate that retail buildings have the highest potential for savings among the building types studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lung cancer mortality among construction workers: implications for early detection

Objectives This study examined predictors of lung cancer mortality, beyond age and smoking, among construction workers employed at US Department of Energy (DOE) sites to better define eligibility for low-dose CT (LDCT) lung cancer screening. Methods Predictive models were based on 17 069 workers and 352 lung cancer deaths. Risk factors included age, gender, race/ethnicity, cigarette smoking, years of trade or DOE work, body mass index (BMI), chest X-ray results, spirometry results, respiratory symptoms, beryllium sensitisation and personal history of cancer. Competing risk Cox models were used to obtain HRs and to predict 5-year risks. Results Factors beyond age and smoking included in the final predictive model were chest X-ray changes, abnormal lung function, chronic obstructive pulmonary disease (COPD), respiratory symptoms, BMI, personal history of cancer and having worked 5 or more years at a DOE site or in construction. Risk-based LDCT eligibility demonstrated improved sensitivity, specificity and positive predictive value compared with current US Preventive Services Task Force guidelines. The risk of lung cancer death from 5 years of work in the construction industry or at a DOE site was comparable with the risk from a personal cancer history, a family history of cancer or a diagnosis of COPD. LDCT eligibility criteria used for DOE construction workers, which includes factors beyond age and smoking, identified 86% of participants who eventually would die from lung cancer compared with 51% based on age and smoking alone. Conclusions Results support inclusion of risk from occupational exposures and non-malignant respiratory clinical findings in LDCT clinical guidelines.

Public, Environmental & Occupational Health↗

Historic Significance and Current Condition Assessment of Building 06-CP-10, Device Assembly Building, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-10, the first device assembly building on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-10 and two small magazine bunkers (06-CP-10A and 06-CP-805) associated with Building 06-CP-10 are scheduled for demolition as part of this undertaking. Building 06-CP-10 was originally recorded in 2003 during a historical evaluation of four buildings in Area 6. In consultation with the Nevada State Historic Preservation Office, the building was determined individually eligible for inclusion in the NRHP under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing and under Significance Criterion C as a distinct type of construction associated with the nuclear industry. Building 06-CP-10A, a munitions magazine, and 06- CP-805, a cap-and-fuse bunker, have been recorded as contributing accessory resources to 06-CP-10. Pursuant to Stipulation III.C.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-10 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.C.2.

54 ENVIRONMENTAL SCIENCES↗

Deep Isolation-Development of the Safety Case for Disposal of Radioactive Wastes in Horizontal Boreholes - 20028

Deep Isolation has developed a safe, secure, and permanent geological disposal method for high-level waste, including spent nuclear fuel as well as sealed sources and other highly radioactive materials. The method leverages well established directional drilling technology to create horizontal repositories deep underground. The combination of great depth (1-3 km) and the ability to precisely position repositories in a horizontal orientation provides access to geologic strata that are inaccessible for typical mined and deep vertical borehole repositories. A number of potential direct and indirect safety benefits accrue including:1) greater depth below regional freshwater aquifers; 2) increased flexibility and more geologic options for siting; 3) access to deep formations with persistent and sustained reducing conditions. In addition there are a number of safety elements related specifically to the horizontal repository geometry including: 1) passive direction of thermally driven fluid and radionuclide movement away from the vertical access hole and toward the 'dead end' portion of the repository; 2) mitigation of seismic hazards by orienting repositories parallel to local and regional fault structures. In this paper we explore and discuss some of the key technologic, geologic and hydrologic elements that support the deep horizontal borehole safety case. The stalemate seen across the globe on the disposal of spent nuclear fuel and high-level waste can be broken. Deep Isolation offers a novel option for safe, secure, and permanent deep geological disposal of nuclear waste that can be developed as centralized repositories or adapted to smaller regional or site-specific repositories located near waste sources. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Historic Significance and Current Condition Assessment of Building 06-CP-170, the Yucca Flat Weather Station, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-170, the Yucca Flat Weather Station on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-170 is scheduled for demolition as part of this undertaking. Building 06-CP-170 was originally recorded in 2018 during a Section 106 cultural resources inventory for a proposed installation of a 138-kilovolt transmission line on the NNSS. The building was determined individually eligible by the DOE, in consultation with the Nevada State Historic Preservation Office, for inclusion in the National Register of Historic Places under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing. Pursuant to Stipulation III.D.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-170 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.D.2.

54 ENVIRONMENTAL SCIENCES↗

Postprocessing techniques for gradient percolation predictions on the square lattice

In this work, we revisit the classic problem of site percolation on a regular square lattice. In particular, we investigate the effect of quantization bias errors on percolation threshold predictions for large probability gradients and propose a mitigation strategy. We demonstrate through extensive computational experiments that the assumption of a linear relationship between probability gradient and percolation threshold used in previous investigations is invalid. Moreover, we demonstrate that, due to skewness in the distribution of occupation probabilities visited the average does not converge monotonically to the true percolation threshold. Furthermore, we identify several alternative metrics which do exhibit monotonic (albeit not linear) convergence and document their observed convergence rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Information needs, approaches, and case studies in human health risk communication

This article uses ten case studies to illustrate the information needs, various communication approaches, and the communicator's role in explaining environmental health risks from a variety of hazards, to a variety of audiences, over time frames from days to years, using in person consultation, lectures, zooms, and email formats. Events often had a long history before the communication began and may have had a long tail afterward. Audiences may be public officials, companies, workers, communities, or individuals. Each individual may have their own understanding or mental model regarding the hazard, exposure, and risk. The communicator's role or intention may be to reassure an audience that has unrealistic exaggerated concerns or fears or to protect a client if the fears are realistic. Or it may be altruistic to inform a complacent audience to take the risks it faces more seriously. Although risk assessment research has advanced the techniques for communicating abstruse probabilities to audiences with low numeracy, in my experience, audiences are unimpressed by precise–sounding probability numbers, and are more interested in whether exposure is occurring or may occur and how to stop it. Often audiences have reason to be outraged and may be more concerned about punishing wrong doers than about the hazard itself, particularly when the exposure is past and cannot be undone. Thus, there is a difference between discussing the riskiness of a situation (risk communication) and what you are going to do about the situation (risk management). Risk communication is successful when the audience responds as intended, calming down or taking action. These case studies are drawn from a large number of risk communication experiences that I and my Rutgers colleagues have engaged in over the past four decades. Through the 20th century, New Jersey was the most densely industrialized State in United States. New Jersey experienced growth of the chemical and petrochemical industries and the unfortunately profligate disposal of toxic wastes. Having the most Superfund sites of any state is a dubious distinction, but New Jersey also has the most experience in evaluating and responding to these hazards.

60 APPLIED LIFE SCIENCES↗

Impact of structural distortions on the correlated electronic structure of orbital-selective Mott insulating Na 3 ⁢Co 2 ⁢SbO 6 under strain

Na 3 Co 2 SbO 6 is a promising candidate to realize the Kitaev spin liquid phase since the large Kitaev spin exchange interaction is tunable via the change in electronic structure, such as the trigonal crystal field splitting (Δ TCF ). Here, in this study, we show that the uncorrelated electronic structure of Na 3 Co 2 SbO 6 is rather insensitive to the strain effect due to the low crystal symmetry accompanied by oxygen displacements and the presence of Sb s orbitals. Using density functional theory plus dynamical mean field theory, we find that the correlated electronic structure of Na 3 Co 2 SbO 6 is an orbital-selective Mott insulating state where the trigonal a 1g orbital is insulating due to the nearly full occupation, while other d orbitals behave as typical Mott insulators, resulting in the effective tunability of Δ TCF under the strain effect. The sign change of Δ TCF can occur as the in-plane tensile strain is applied, and the Kitaev spin liquid phase could possibly be realized due to the strongly suppressed Δ TCF under tensile strain. Our results show that the local Co-site symmetry and dynamical correlation effects will play an important role in engineering the novel magnetic phase in this and related materials.

Nguyen, Nam [Univ. of Illinois, Chicago, IL (Unite↗

Diffraction-quality, ultraflexible protein single crystals engineered with DNA

DNA-functionalized colloidal nanoparticles assemble through flexible, nanoscale DNA hybridization interactions that limit atomic-level structural order. Here, we report a valence-centric strategy that enables DNA-bonded, protein single crystals with unconventional mechanical properties. An octameric enzyme, glutarate L-2-hydroxylase, was site- and number-selectively conjugated with eight self-complementary single-stranded DNA, yielding octavalent molecular bonds. The resulting conjugate assembled into the designed body-centered tetragonal crystals that diffracted to 1.42- to 2.61-angstrom resolution, with contacts mediated by B-form DNA helices spanning 17 to 25 angstroms. Increasing oligonucleotide length induces anisotropic lattice expansion while preserving atomic periodicity, even with partial DNA occupancy. Mechanistic studies suggest that the dynamic motion of unhybridized DNA facilitates crystallization, analogous to fluctuating electron clouds in atomic bonding. Compared with native protein crystals, DNA-hybridized crystals are 23-fold softer. These results challenge the assumption that flexibility is incompatible with structural order and establish a programmable framework for biomolecular crystallization and nanomaterials engineering with atomic precision.

Han, Zhenyu [Department of Chemistry, Northwestern↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of impurities on hydrogen defect stability and migration barrier in yttrium dihydride crystal

The impurity or alloying atoms in YH 2 can alter the local electronic structure and so the hydrogen defect stability, as well as the H migration barrier energy. Thus, DFT calculations were employed to determine the effect of foreign elements from alkali and alkaline earth metals to transition metals and one critical impurity element, O, on H vacancy stability and retention characteristics in YH2. Results revealed that alloying elements act as hydrogen vacancy sinks by reducing the vacancy formation energy at neighboring sites. The implantation of non-magnetic foreign elements (s1, s2, and d10 valence electrons) in hydrogen energy landscape was calculated to be minor; while the hydrogen vacancy formation energy was reduced from 1.37 eV to 1.00 eV, the migration energy barrier of hydrogen was increased from 0.87 eV to 1.15 eV for non-magnetic foreign elements. The migration energy barrier monotonically decreased with increasing d-shell occupancy, reaching as low as 0.4 eV for Cr, Mo(d4), and Fe (d4). Alloying with late transition metals (d8 and d9) moderately impacted the hydrogen vacancy formation. Finally, it was found to be O addition into the YH 2- lattice did not alter the energy landscape of hydrogen vacancies. Since alloyed YH 2 has not been studied extensively, this study provides an atomistic understanding how alloying elements and impurities trap vacancies and affects hydrogen mobility YH 2 . Meanwhile, the main findings of this study may serve as guidelines for introducing alloying elements in ZrH 2 as well.

08 HYDROGEN↗

Genetic variation at transcription factor binding sites largely explains phenotypic heritability in maize

Abstract Comprehensive maps of functional variation at transcription factor (TF) binding sites (cis-elements) are crucial for elucidating how genotype shapes phenotype. Here, we report the construction of a pan-cistrome of the maize leaf under well-watered and drought conditions. We quantified haplotype-specific TF footprints across a pan-genome of 25 maize hybrids and mapped over 200,000 variants, genetic, epigenetic, or both (termed binding quantitative trait loci (bQTL)), linked tocis-element occupancy. Three lines of evidence support the functional significance of bQTL: (1) coincidence with causative loci that regulate traits, includingvgt1,ZmTRE1and the MITE transposon nearZmNAC111under drought; (2) bQTL allelic bias is shared between inbred parents and matches chromatin immunoprecipitation sequencing results; and (3) partitioning genetic variation across genomic regions demonstrates that bQTL capture the majority of heritable trait variation across ~72% of 143 phenotypes. Our study provides an auspicious approach to make functionalcis-variation accessible at scale for genetic studies and targeted engineering of complex traits.

Genetics & Heredity↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗