Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectroscopy experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Solar Ion Processing of Major Element Surface Compositions of Mature Mare Soils: Insights from Combined XPS and Analytical TEM Observations

Solar wind ions are capable of altering the sur-face chemistry of the lunar regolith by a number of mechanisms including preferential sputtering, radiation-enhanced diffusion and sputter erosion of space weathered surfaces containing pre-existing compositional profiles. We have previously reported in-situ ion irradiation experiments supported by X-ray photoelectron spectroscopy (XPS) and analytical TEM that show how solar ions potentially drive Fe and Ti reduction at the monolayer scale as well as the 10-100 nm depth scale in lunar soils [1]. Here we report experimental data on the effect of ion irradiation on the major element surface composition in a mature mare soil.

Christoffersen, R.↗

Comparison of satellite ozone observations in coincident air masses in early November 1994

Ozone observed by seven satellite instruments, the Atmospheric Trace Molecule Spectroscopy instrument (ATMOS), Stratospheric Aerosol and Gas Experiment (SAGE) II, Polar Ozone and Aerosol Measurement (POAM) II instrument, Halogen Occultation Experiment (HALOE), Microwave Limb Sounder (MLS), Cryogenic Infrared Spectrometers and Telescopes for the Atmosphere (CRISTA), and Millimeter-wave Atmospheric Sounder (MAS), during early November 1994 is mapped in equivalent latitude/potential temperature (EqL/ theta )space to facilitate nearly global comparisons of measurements taken in similar air masses.

atmospheric↗

Remote sensing of subsurface water temperature by laser Raman spectroscopy

This paper describes experimental remote sensing of subsurface water temperature using the Raman spectroscopic technique. By the use of a pulsed laser and range gating detection techniques, Raman scattering is analyzed as a function of depth in a radar-like echo mode, and thus subsurface profiles of temperature and transmission are obtained. Experiments are described in which Raman data using polarization spectroscopy has been obtained from a ship as a function of depth in ocean water near Grand Bahama Island. A spectral temperature accuracy of + or - 1 C has been obtained from this data in the first two optical attenuation lengths. Raman data obtained from ocean water using the NASA airborne oceanographic lidar is also presented.

Leonard, D. A.↗

The FRIB Decay Station: New Horizons with Rare Isotopes

In May 2022, the Facility for Rare Isotope Beams (FRIB), located on the campus of Michigan State University (MSU), began delivering exotic isotopes to an international community of scientists. New discoveries are now being reported from radioactive decay of neutron-rich nuclei near N = 20 and N = 28.FRIB is expected to produce roughly 80% of the unstable or radioactive isotopes predicted to exist up to uranium (Z = 92). The new user facility is supported by the U.S. Department of Energy, and it is operated by MSU. A high-power superconducting linear accelerator, shaped like a paper-clip, drives the production of these rare isotopes by colliding stable nuclei moving at half the speed of light with a rotating, water-cooled graphite tar-get. These collisions cause the primary stable beam to fragment into a wide variety of unstable nuclei, which can be subsequently filtered through a multistage magnetic separator, the Advanced Rare Isotope Separator, and transported to one of several experimental stations. The FRIB Decay Station initiator (FDSi) (see Figure 1) was developed to enable comprehensive radio-active decay studies of the exotic nuclei produced by FRIB and it was used in the first two experiments in 2022. Further, the FDSi is a highly reconfigurable multidetector system with two focal planes (FP1 for discrete spectroscopy and FP2 for total absorption spectroscopy) that can be optimized for the specific science goals of each experiment. It is designed, built, and operated by a community of users with the sup-port of U.S. funding agencies, including the Department of Energy and National Science Foundation.

07 ISOTOPE AND RADIATION SOURCES↗

High throughput battery failure experimental platform

Addressing the need to increase the sample set to understand the causes of lithium battery thermal runaway, we conceived of an experimental platform with capability to increase the number of runaway experiments (currently 3-5 per week), while also collecting detailed electrochemical impedance spectroscopy measurements (EIS). Once expanded, the platform would enable data collection on 10s to 100s of cells that all experience runaway, thereby creating a statistical database necessary to identify early indication of risk. A primary containment unit to house cylindrical cells of variety NMC811 and of size 21700 (21 mm diameter by 70 mm length) was designed with features such as debris containment, preloaded cells in an exchangeable port, nitrogen ventilation, and exhaust containment. We performed the first overcharge abuse experiments of several 21700 cells, handpicked because of different initial EIS, and demonstrated that EIS changes dramatically during early stages of overcharge, but in a different manner than previous pouch cell experiments. The abuse experiments also revealed the discharge pattern and debris field created during runaway, as well as the cell temperature control and overheat, that must be considered in the primary containment apparatus. We designed and built a switching relay system to permit measurement of EIS without an active charging circuit, and created instrument control software for charging, EIS, and cell temperature control. The late-start funding was insufficient to fully construct the primary containment unit, but the foundational design and knowhow is available for any future work.

25 ENERGY STORAGE↗

The Gamma-Ray Imaging Spectrometer (GRIS): A new balloon-borne experiment for gamma-ray line astronomy

High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments.

Teegarden, B. J.↗

BATSE spectroscopy detector calibration

We describe the channel-to-energy calibration of the Spectroscopy Detectors of the Burst and Transient Source Experiment (BATSE) on the Compton Gamma Ray Observatory (GRO). These detectors consist of NaI(TI) crystals viewed by photomultiplier tubes whose output in turn is measured by a pulse height analyzer. The calibration of these detectors has been complicated by frequent gain changes and by nonlinearities specific to the BATSE detectors. Nonlinearities in the light output from the NaI crystal and in the pulse height analyzer are shifted relative to each other by changes in the gain of the photomultiplier tube. We present the analytical model which is the basis of our calibration methodology, and outline how the empirical coefficients in this approach were determined. We also describe the complications peculiar to the Spectroscopy Detectors, and how our understanding of the detectors' operation led us to a solution to these problems.

Band, D.↗

Electrochemically Mediated Au–C(sp 2 ) Anchors for Molecular Electronics

Terminal anchor groups play a key role in the stability and electronic properties of molecular junctions. Single molecule junctions typically consist of two preinstalled terminal anchors linking organic molecules to metal electrodes. Here, in this work, we show that p -terphenyl derivatives containing only a single terminal anchor show conductance features similar to junctions with two preinstalled terminal anchors. A set of p -terphenyl derivatives with one terminal anchor was prepared using automated chemical synthesis and characterized using single molecule electronics experiments, molecular dynamics (MD) simulations, bulk electrochemistry and spectroscopy, and nonequilibrium Green’s function-density functional theory (NEGF-DFT) calculations. Our results show that 4-amino- p -terphenyl (PPP) and related analogs exhibit a well-defined high conductance state that is diminished or absent in other p-terphenyl derivatives lacking a preinstalled amine terminal anchor or fluorine or methyl substitutions at the terminal para position. However, a low conductance state is observed in all amino- p -terphenyl derivatives with one preinstalled anchor due to molecular junctions formed by noncovalent dimeric π–π stacking interactions. The observed high conductance state diminishes upon the addition of reducing agents and is restored upon the addition of an oxidizing agent. Our results suggest that the high conductance state arises due to Au–C(sp 2 ) bond formation facilitated by a single electron oxidation event at the electrode surface. A series of control experiments with different anchor groups shows that primary amines play a key role in forming Au–C bonds for molecular junctions. Overall, these results suggest that Au–C bond formation gives rise to high conductance pathways in organic molecules containing only one preinstalled terminal anchor. Insights from this work can be leveraged in the design of molecular electronic devices, particularly in understanding the mechanisms of molecular binding and junction formation.

charge transport↗

Analysis methodology of coherent oscillations in time- and angle-resolved photoemission spectroscopy

Oscillatory signals from coherently excited phonons are regularly observed in ultrafast pump–probe experiments on condensed matter samples. Electron–phonon coupling implies that coherent phonons also modulate the electronic band structure. These oscillations can be probed with energy and momentum resolution using time- and angle-resolved photoemission spectroscopy (trARPES), which reveals the orbital dependence of the electron–phonon coupling for a specific phonon mode. However, a comprehensive analysis remains challenging when multiple coherent phonon modes couple to multiple electronic bands. Complex spectral line shapes due to strong correlations in quantum materials add to this challenge. In this work, we examine how the frequency domain representation of trARPES data facilitates a quantitative analysis of coherent oscillations of the electronic bands. Here, we investigate the frequency domain representation of the photoemission intensity and the first moment of the energy distribution curves. Both quantities provide complementary information and are able to distinguish oscillations of binding energy, linewidth, and intensity. We analyze a representative trARPES dataset of the transition metal dichalcogenide WTe 2 and construct composite spectra, which intuitively illustrate how much each electronic band is affected by a specific phonon mode. We also show how a linearly chirped probe pulse can generate extrinsic artifacts that are distinct from the intrinsic coherent phonon signal.

47 OTHER INSTRUMENTATION↗

SHIVER - Spectroscopy HIstogram Visualizer for Event Reduction

Visualizing data from neutron scattering experiments is the first step in understanding the physics. The program is intended to generate and plot cuts and slices, through the four dimensional single crystal inelastic datasets, measured on direct geometry neutron spectrometers at the Spallation Neutron Source (ARCS, CNCS, HYSPEC, SEQUOIA).

Savici, AndreiT [Oak Ridge National Laboratory (OR↗

High-resolution laser absorption spectroscopy of ozone near 1129.4 cm (-1)

A Beer's Law experiment was performed with a tunable diode laser to determine self broadened line shape parameters of one infrared absorption ozone line in the nu1 band for ten pressures from 0.26 to 6.29 torr at 285 K. The SO2 line positions were used for wavelength calibration. Line shapes were iteratively fitted to the Voigt function at a Doppler width of 29.54 MHz (HWHM) resulting in values for the integrated line strength, (S), of (0.144 +/- 0.007) x 10 to the minus 20th/cm molecule/cu cm, line center frequency, nu sub o, of 1129.426/cm and the Lorentzian contributions to halfwidth. A linear least squares fit of (alpha sub L)5 as a function of pressure yielded a zero intercept of 15.27 +/- 0.29 MHz (rho = 0.99) and a broadening parameter, (alpha sub L)5, of 5.71 +/- 0.29 MHz/Torr. This results in a line width (FWHM) of 0.144 +/- .007/cm at 760 torr and 285 K.

Majorana, L. N.↗

Gamma-ray/neutron spectroscopy from the Mars observer

The Gamma-Ray Spectrometer (GRS) experiment on Mars Observer will measure gamma rays and neutrons that escape from Mars. The intensities of gamma-ray lines and of the thermal and epithermal neutrons can be used to study many problems related to Martian volcanism and volatiles. The results of theoretical calculations for the production and transport of gamma rays and neutrons indicate that the GRS should be able to determine the abundances of many elements and the amounts and stratigraphy of H2O and CO2 on and in the top meter of the Martian surface. Design considerations of the GRS are discussed.

Englert, P.↗

Injector Mixing Efficiency Experiments

Various optical diagnostic techniques such as laser induce fluorescence, Raman spectroscopy, laser Doppler velocimetry, and laser light scattering have been employed to study the flowfield downstream of a single injector element in a optically accessible rocket chamber at Penn State for a number o years. These techniques have been used with both liquid and gaseous oxygen at pressures up to 1000 psia which is the limit of the facility. The purpose of the test programs at Penn State were to develop the techniques and to study the flow field from various injector designs. To extend these studies to higher pressure and ultimately to multiple injectors require the capabilities of the Marshall Space Flight Center. These studies will extend the data base available for the various injector designs to higher pressure as well as to determine the interaction between multiple injectors. During this effort the Princeton Instruments ICCD camera was set up and checked out. The functionality of the system has been thoroughly checked and the shutter compensation time was found to be not working. The controller was returned to the manufacturer for warranty repair. The sensitivity has been measured and found to be approximately 60 counts per photon at maximum gain which agrees with the test data supplied by the manufacturer. The actual value depends on wavelength. The Princeton Instruments camera was been installed in a explosion proof tube for use with the rocket combustor. A 35 mm camera was also made ready for taking still photos inside the combustor. A fiber optic was used to transmit the laser light from an argon-ion laser to the rocket combustor for the light scattering images. This images were obtained for a LOX-hydrogen swirl coax injector. Several still photos were also obtained with the 35 mm camera for these firings.

Moser, Marlow D.↗

Coherent light scattering spectroscopy for supersonic flow measurements

A unified discussion on coherent light scattering spectroscopy and its spectral dependence on molecular gas velocity, temperature and density is presented. The feasibility of using coherent Raman spectroscopy techniques for nonintrusive measurements of supersonic flow parameters is demonstrated and recent laboratory as well as wind tunnel experiments are reviewed. In addition, the advantages of using coherent Rayleigh-Brillouin spectroscopy for measuring high pressure flows are discussed.

She, C. Y.↗

Comparison of time-resolved photoluminescence and deep-level transient spectroscopy defect evaluations in an InAs nBn detector subjected to in situ and ex situ 63 MeV proton irradiation

Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in situ and ex situ 63 MeV proton irradiation to assess their generation and recombination dynamics. Pre-irradiation, the n-type InAs absorbing region, exhibits a steadily increasing minority carrier lifetime with increasing temperature, providing evidence that excited minority carriers may be recombining via shallow defect levels. From deep-level transient spectroscopy, two features are found between 10 and 275 K: a low temperature broad “shoulder,” which suggests emission from multiple shallow electron defect levels with energies <29 meV and a high temperature minimum occurring at ∼230 K with an activation energy of 539 meV, which suggests a defect in the barrier layer in the device. Two similar nBn detectors are then subjected to 63 MeV proton irradiation in step doses and measured between steps. One experiment is performed in situ with an nBn held at ∼10 K during dosing, and the other experiment is performed ex situ with a similar nBn held at room temperature for dosing. The ex situ dosing results in an evaluation of the defect introduction rate that is three to four times lower than in situ due to partial annealing of the proton-induced displacement damage at room temperature. The results of these two experiments are then compared with the dose-dependent recombination rate analysis, resulting in an estimated recombination defect cross section of 1.6 × 10 −13 cm 2 for the shallow shoulder defect.

Carrasco, Rigo A. [Air Force Research Laboratory (↗

Far-infrared measurements of trace gases

A better detector system was developed for far infrared spectroscopy by usng cryogenic technology to cool bolometric detectors to approximately 0.4K. Technical assistance was provided to two submillimeter infrared balloon experiment (SIBEX) flights which demonstrated the diagnostic capability of far IR emission spectroscopy. It is estimated that more than a hundred spectral emission features were detected which are not due to the main emitting gases O3, O2, and H2O. The trace species sources for many features still remain unidentified and the spectra obtained during the SIBEX flights present a new source of information on stratospheric composition.

Nolt, I. G.↗

Shining Light on Halide Perovskites: Teaching Analytical Chemistry Using Flexible, Inquiry-Based Experiments

Two-dimensional (2D) metal halide perovskites are promising next generation semiconducting materials at the forefront of research in solar cells, LEDs, and other devices. Here, we report on an undergraduate intermediate analytical chemistry laboratory experience where students were taught fundamental chemistry concepts, including solubility, complexation, spectroscopy, and microscopy, through the introduction and study of 2D halide perovskite materials. Students explore multiple facets of perovskite synthesis, structure, and properties through a modular set of experiments that students used to form a holistic picture of this material. Importantly, this inquiry-based lab supports students through a guided research process, and students report high interest and learning gains from an end of the semester survey. We further discuss ways to adapt this lab to course, student, equipment, and budget needs. Overall, this laboratory experience teaches and applies the fundamental concepts and tools of analytical chemistry to the contemporary materials research field.

Analytical Chemistry↗