The influential aspects of atmospheric disturbances on space vehicle design using statistical approaches for analysis
Statistical analysis of influencial aspects of wind profile disturbances design and dynamic response of space vehicles
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Statistical analysis of influencial aspects of wind profile disturbances design and dynamic response of space vehicles
Statistical analysis of space navigation systems based on multivariate Gaussian distributions and linear perturbation theory
The trend of increasing application of distributed generation with solar photovoltaics (PV-DG) suggests that a widespread integration in existing low-voltage (LV) grids is possible in the future. With massive integration in LV grids, a major concern is the possible negative impacts of excess power injection from on-site generation. For power-flow simulations of such grid impacts, an important consideration is the time resolution of demand and generation data. This paper investigates the impact of time averaging on high-resolution data series of domestic electricity demand and PV-DG output and on voltages in a simulated LV grid. Effects of 10-minutely and hourly averaging on descriptive statistics and duration curves were determined. Although time averaging has a considerable impact on statistical properties of the demand in individual households, the impact is smaller on aggregate demand, already smoothed from random coincidence, and on PV-DG output. Consequently, the statistical distribution of simulated grid voltages was also robust against time averaging. The overall judgement is that statistical investigation of voltage variations in the presence of PV-DG does not require higher resolution than hourly. (author)
Particle fracture represents an important mode of battery electrode degradation. Extensive cracking occurs in the layered oxide cathodes of lithium-ion rechargeable batteries when they are charged beyond safe operational voltages. In this paper, we analyze the morphology and distribution of cracks in over 100 overcharged LiCoO 2 (LCO) single-crystalline particles imaged via X-ray nanotomography. Herein, we observe a strong particle size dependence in both nucleation and growth of cracks, with percentage of cracked particles, crack size, and crack surface area per unit volume all increasing significantly with particle volume. Increasing the cutoff voltage above 4.6V is found to trigger much more pronounced crack growth, which we attribute to the large misfit stress caused by the H1-3 to O1 phase transition. This study offers valuable statistical insights into the fracture behavior of layered oxide cathodes and reveals the importance of particle size control on electromechanical degradation of battery electrodes.
Important factors to consider when optimizing Lithium-ion (Li-ion) battery thermal management systems, from a battery safety perspective, include the total energy released during a single cell thermal runaway (TR) event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A fractional thermal runaway calorimeter (FTRC) was used to examine the TR behavior of the following 18650-format Li-ion cells: (1) Molicel 18650-J, (2) LG 18650-HG2, (3) Samsung 18650-30Q, (4) 3.35 Ah LG 18650 test cell, (5) Sony 18650-VC7, and (6) LG 18650-MJ1. These cells were intentionally selected to represent a variety of manufacturers, chemistries, capacities, and safety features. Because of the large number of random and non-random variables associated with the FTRC results, a linear regression model, developed using engineering statistical methods, was utilized to provide final interpretation of the TR behavior for each cell type and design variable combination.
The physical mechanisms that contribute to atmospheric breakdown induced by high power microwaves (HPMs) are of particular interest for the further development of high power microwave systems and related technologies. For a system in which HPM is produced in a vacuum environment for the purpose of radiating into atmosphere, it is necessary to separate the atmospheric environment from the vacuum environment with a dielectric interface. Breakdown across this interface on the atmospheric side and plasma development to densities prohibiting further microwave propagation are of special interest. In this paper, the delay time between microwave application and plasma emergence is investigated. Various external parameters, such as UV illumination or the presence of small metallic points on the surface, provide sources for electron field emission and influence the delay time which yields crucial information on the breakdown mechanisms involved. Due to the inherent statistical appearance of initial electrons and the statistics of the charge carrier amplification mechanisms, the flashover delay times deviate by as much as {+-}50% from the average, for the investigated case of discharges in N{sub 2} at pressures of 60-140 Torr and a microwave frequency of 2.85 GHz with 3 {mu}s pulse duration, 50 ns pulse risetime, and MW/cm{sup 2} power densities. The statistical model described in this paper demonstrates how delay times for HPM surface flashover events can be effectively predicted for various conditions given sufficient knowledge about ionization rate coefficients as well as the production rate for breakdown initiating electrons.
The superconducting radio frequency (SRF) technology is progressing rapidly over last decades toward high accelerating gradients and low surface resistance making feasible the particle accelerators operation with high beam currents and long duty factors. However, the coherent RF losses due to high order modes (HOMs) excitation becomes a limiting factor for these regimes. In spite of the operating mode, which is tuned separately, the parameters of HOMs vary from one cavity to another due to finite mechanical tolerances during cavities fabrication. It is vital to know in advance the spread of HOM parameters in order to predict unexpected cryogenic losses, overheating of beam line components and to keep stable beam dynamics. In this paper we present the method of generating the unique cavity geometry with imperfections while preserving operating mode frequency and field flatness. Based on the eigenmode spectrum calculation of series of randomly generated cavities we can accumulate the data for the evaluation the HOM statistics. Finally, we describe the procedure for the estimation of the probability of the resonant HOM losses in the SRF resonators. The study of these effects leads to specifications of SC cavity and cryomodule and can significantly impact on the efficiency and reliability of the machine operation
Simulated data from the UCLA cumulus ensemble model are used to investigate the quasi-universal validity of closure assumptions used in existing cumulus parameterizations. A closure assumption is quasi-universally valid if it is sensitive neither to convective cloud regimes nor to horizontal resolutions of large-scale/mesoscale models. The dependency of three types of closure assumptions, as classified by Arakawa and Chen, on the horizontal resolution is addressed in this study. Type I is the constraint on the coupling of the time tendencies of large-scale temperature and water vapor mixing ratio. Type II is the constraint on the coupling of cumulus heating and cumulus drying. Type III is a direct constraint on the intensity of a cumulus ensemble. The macroscopic behavior of simulated cumulus convection is first compared with the observed behavior in view of Type I and Type II closure assumptions using 'quick-look' and canonical correlation analyses. It is found that they are statistically similar to each other. The three types of closure assumptions are further examined with simulated data averaged over selected subdomain sizes ranging from 64 to 512 km. It is found that the dependency of Type I and Type II closure assumptions on the horizontal resolution is very weak and that Type III closure assumption is somewhat dependent upon the horizontal resolution. The influences of convective and mesoscale processes on the closure assumptions are also addressed by comparing the structures of canonical components with the corresponding vertical profiles in the convective and stratiform regions of cumulus ensembles analyzed directly from simulated data. The implication of these results for cumulus parameterization is discussed.
Variability in the aerial and root environments of NASA's Breadboard Project's Biomass Production Chamber (BPC) was determined. Data from two lettuce and two potato growouts were utilized. One growout of each crop was conducted prior to separating the upper and lower chambers; the other was subsequent to separation. There were little or no differences in pH, EC, or solution temperature between the upper and lower chamber or within a chamber. Variation in the aerial environment within a chamber was two to three times greater than variation between chambers for air temperature, relative humidity, and PPF. High variability in air velocity, relative to tray position, was observed. Separating the BPC had no effect on PPF, air velocity, solution temperature, pH, or EC. Separation reduced the gradient in air temperature and relative humidity between the upper and lower chambers, but increased the variability within a chamber. Variation between upper and lower chambers was within 5 percent of environmental set-points and of little or no physiological significance. In contrast, the variability within a chamber limits the capability of the BPC to generate statistically reliable data from individual tray treatments at this time.
Widely recognized as one of the worst natural disaster in Puerto Rico's history, hurricane María made landfall on September 20, 2017 in southeast Puerto Rico as a high-end category 4 hurricane on the Saffir-Simpson scale causing widespread destruction, fatalities and forest disturbance. This study focused on hurricane María's effect on Puerto Rico's forests as well as the effect of landform and forest characteristics on observed disturbance patterns. In this work, we used Google Earth Engine (GEE) to assess the severity of forest disturbance using a disturbance metric based on Landsat 8 satellite data composites with pre and post-hurricane María. Forest structure, tree phenology characteristics, and landforms were obtained from satellite data products, including digital elevation model and global forest canopy height. Our analyses showed that forest structure, and characteristics such as forest age and forest type affected patterns of forest disturbance. Among forest types, highest disturbance values were found in sierra palm, transitional, and tall cloud forests; seasonal evergreen forests with coconut palm; and mangrove forests. For landforms, greatest disturbance metrics was found at high elevations, steeper slopes, and windward surfaces. As expected, high levels of disturbance were also found close to the hurricane track, with disturbance less severe as hurricane María moved inland. Results demonstrated that forest and landform characteristics accounted for 34% of the variation in spatial forest spectral disturbance patterns. This study demonstrated an informative regional approach, combining remote sensing with statistical analyses to investigate factors that result in variability in hurricane effects on forest ecosystems.
The NASA Glenn Research Center is constructing a 616 element scanning phased array antenna using thin film Ba(sub x)Sr(sub 1-x)TiO(sub 3) based phase shifters. A critical milestone is the production of 616 identical phase shifters at 19 GHz with [asymptotically equal to]4 dB insertion loss and at least 337.5 deg phase shift with 3 percent bandwidth. It is well known that there is a direct relationship between dielectric tuning and loss due to the Kramers-Kronig relationship and that film crystallinity and strain, affected by the substrate template, play an important role. Ba(sub 0.50)Sr(sub 0.50)TiO (sub 3) films, nominally 400 nm thick, were deposited on 48 0.25 mm thick, 5 cm diameter LaAlO(sub 3) wafers. Although previous results suggested that Mn-doped films on MgO were intrinsically superior in terms of phase shift per unit loss, for this application phase shift per unit length was more important. The composition was selected as a compromise between tuning and loss for room temperature operation (e.g. crystallinity progressively degrades for Ba concentrations in excess of 30 percent). As a prelude to fabricating the array, it was necessary to process, screen, and inventory a large number of samples. Variable angle ellipsometry was used to characterize refractive index and film thickness across each wafer. Microstructural properties of the thin films were characterized using high resolution X-ray diffractometry. Finally, prototype phase shifters and resonators were patterned on each wafer and RE probed to measure tuning as a function of dc bias voltage as well as peak (0 field) permittivity and unloaded Q. The relationship among film quality and uniformity and performance is analyzed. This work presents the first statistically relevant study of film quality and microwave performance and represents a milestone towards commercialization of thin ferroelectric films for microwave applications.
Degradation pathway models constructed using network structural equation modeling (netSEM) are used to study degradation modes and pathways active in photovoltaic (PV) system variants in exposure conditions of high humidity and temperature. This data-driven modeling technique enables the exploration of simultaneous pairwise and multiple regression relationships between variables in which several degradation modes are active in specific variants and exposure conditions. Durable and degrading variants are identified from the netSEM degradation mechanisms and pathways, along with potential ways to mitigate these pathways. A combination of domain knowledge and netSEM modeling shows that corrosion is the primary cause of the power loss in these glass/backsheet PV minimodules. We show successful implementation of netSEM to elucidate the relationships between variables in PV systems and predict a specific service lifetime. The results from pairwise relationships and multiple regression show consistency. This work presents a greater opportunity to be expanded to other materials systems.
Since October 2015, NASA Glenn Research Center (GRC) and the Air Force Research Laboratory (AFRL) have collaboratively operated an RF terrestrial link in Albuquerque, New Mexico to characterize atmospheric propagation phenomena at 72 and 84 GHz. The W/V-band Terrestrial Link Experiment (WTLE) consists of coherent transmitters at each frequency on the crest of the Sandia Mountains and a corresponding pair of receivers in south Albuquerque. The beacon receivers provide a direct measurement of the link attenuation, while concurrent weather instrumentation provides a measurement of the atmospheric conditions. Among the available weather instruments is an optical disdrometer which yields an optical measurement of rain rate, as well as droplet size and velocity distributions (DSD, DVD). In particular, the DSD can be used to derive an instantaneous scaling factor (ISF) by which the measured data at one frequency can be scaled to another - for example, scaling the 72 GHz to an expected 84 GHz timeseries. Given the availability of both the DSD prediction and the directly observed 84 GHz attenuation, WTLE is thus uniquely able assess DSD-derived instantaneous frequency scaling at the V/W-bands. Previous work along these lines has investigated the DSD-derived ISF at Ka and Q-band (20 GHz to 40 GHz) using a satellite beacon receiver experiment in Milan, Italy. This work will expand the investigation to terrestrial links in the V/W-bands, where the frequency scaling factor is lower and where the link is also much more sensitive to attenuation by rain, clouds, and other atmospheric effects.
Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentified metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Altogether, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses.
Here, observations from the Energetic Particle Detector (EPD) instrument suite aboard the Magnetospheric Multiscale (MMS) spacecraft show that energetic (greater than tens of keV) magnetospheric particle escape into the magnetosheath occurs commonly across the dayside. This includes the surprisingly frequent observation of magnetospheric electrons in the duskside magnetosheath, an unexpected result given assumptions regarding magnetic drift shadowing. The 238 events identified in the 40 keV electron energy channel during the first MMS dayside season that exhibit strongly anisotropic pitch angle distributions indicating monohemispheric field-aligned streaming away from the magnetopause. A review of the extremely rich literature of energetic electron observations beyond the magnetopause is provided to place these new observations into historical context. Despite the extensive history of such research, these new observations provide a more comprehensive data set that includes unprecedented magnetic local time (MLT) coverage of the dayside equatorial magnetopause/magnetosheath. These data clearly highlight the common escape of energetic electrons along magnetic field lines concluded to have been reconnected across the magnetopause. While these streaming escape events agree with prior studies which show strong correlation with geomagnetic activity (suggesting a magnetotail source) and occur most frequently during periods of southward IMF, the high number of duskside events is unexpected and previously unobserved. Although the lowest electron energy channel was the focus of this study, the events reported here exhibit pitch angle anisotropies indicative of streaming up to 200 keV, which could represent the magnetopause loss of >1 MeV electrons from the outer radiation belt.
As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well-documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? Results compiled from approximately 200 perovskite PV cells, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. Here, the implications of these findings on performance testing protocols are discussed and possible options for fast and accurate testing of perovskite PV are proposed.
Abstract not provided.