Superconducting magnet beta-ray spectrometer.
Superconducting magnet spectrometer using lithium drifted silicon detectors for measurement of electron spectra
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Superconducting magnet spectrometer using lithium drifted silicon detectors for measurement of electron spectra
A modern cold triple axis spectrometer is being planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the design of an incident beamline that will put a flux of ~ 10 8 $\frac {n}{cm^{2}s}$ on a sample with an area of 2 cm X 2 cm. It takes current physical constraints at HFIR into account and it can accommodate both single and multiplexed analyzer-detector secondary spectrometers and large superconducting magnets. The proposed incident beamline includes a multi-channel guide with horizontal focusing, a neutron velocity selector, components to facilitate an incident beam polarization option, and a double-focusing pyrolytic graphite monochromator. Here, this work describes the process of optimizing the guide system and monochromator and summarizes the expected performance of the incident beamline for non-polarized operation.
Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.
We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.
Soft X-ray absorption spectroscopy of first row transition elements at their respective L -edges provides important information about the oxidation and spin states of the metal centers. However, the associated sample damage in radiation-sensitive samples substantially alters the electronic and chemical structures of redox-active metal centers. Here, we measure the soft X-ray spectrum of the model Mn III (acac) 3 complex containing a redox-active Mn III metal center in an octahedral environment with a superconducting transition-edge sensor detector. To reduce the secondary damage resulting primarily from the diffusion of radicals and electrons, the spectra are collected at 30 K and 80 K on solid samples. Starting from the first scan, we detect the contribution of X-ray induced sample damage leading to a change in the Mn II intensity. However, at low temperatures, particularly at 30 K, we do not observe a gradual increase in the radiation damage with successive scans with the X-ray beam at the same spot. At our estimated dose of 90 kGy, we find 62% of Mn III (acac) 3 is still intact at 30 K. However, at room temperature, we see a gradual increase in radiation damage with increasing numbers of scans at the same spot, which is consistent with the possibility of increased diffusion rates of secondary radicals and electrons as noted in other studies.
Some potential applications of superconductivity in space are summarized, e.g., the use of high field magnets for cosmic ray analysis or energy storage and generation, space applications of digital superconducting devices, such as the Josephson switch and, in the future, a superconducting computer. Other superconducting instrumentation which could be used in space includes: low frequency superconducting sensors, microwave and infrared detectors, instruments for gravitational studies, and high-Q cavities for use as stabilizing elements in clocks and oscillators.
The EXperiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases, and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM’s cryogenic telescope features sixμ-Spec spectrometers.μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from420−540 GHz with a resolving power R=λ/∆λ= 512, and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2×10−18W/√Hz (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9◦half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has developed a photon-counting optical ground receiver for pulse-position modulated signals. The real-time receiver system includes a fiber interconnect, superconducting nanowire single-photon detectors (SNSPDs), and a real-time field programmable gate array (FPGA) based receiver. The fiber interconnect and SNSPDs are implemented with two different configurations. In the first, a 7-channel few-mode fiber photonic lantern couples the light from the telescope to 7 single-pixel few-mode fiber coupled SNSPDs. In the second configuration, a few-mode fiber couples light to a 16-pixel monolithic SNSPD array. The real-time FPGA-based receiver performs combining of up to 16 SNSPD channels, symbol timing recovery, demodulation, and decoding. The system is scalable with data rates ranging from 20 Mbps to 267 Mbps. It is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Standard. This standard will be used in NASA deep space and other low photon flux missions, such as in the Orion Artemis-2 Optical Communications System (O2O) demonstration, planned for the first crewed flight of Orion. This paper describes the scalable real-time optical receiver system and presents characterization test results.
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has developed a photon-counting optical ground receiver for pulse-position modulated signals. The real-time receiver system includes a fiber interconnect, superconducting nanowire single-photon detectors (SNSPDs), and a real-time field programmable gate array (FPGA) based receiver. The fiber interconnect and SNSPDs are implemented with two different configurations. In the first, a 7-channel few-mode fiber photonic lantern couples the light from the telescope to 7 single-pixel few-mode fiber coupled SNSPDs. In the second configuration, a few-mode fiber couples light to a 16-pixel monolithic SNSPD array. The real-time FPGA-based receiver performs combining of up to 16 SNSPD channels, symbol timing recovery, demodulation, and decoding. The system is scalable with data rates ranging from 20 Mbps to 267 Mbps. It is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Standard. This standard will be used in NASA deep space and other low photon flux missions, such as in the Orion Artemis-2 Optical Communications System (O2O) demonstration, planned for the first crewed flight of Orion. This paper describes the scalable real-time optical receiver system and presents characterization test results.
The NASA Orion O2O mission was designed and tested to support high-rate bi-directional optical communications between one of multiple ground sites and a crewed capsule during a 10-day mission. This paper focuses on the design and performance of the receiver that will be based at the NASA White Sands Complex, New Mexico, USA. The main receiver components consist of two 40-cm apertures, each coupled to a specialty multi-mode optical fiber; each fiber coupled to a custom array of superconducting nanowire single-photon detectors; a high-speed, high-channel-count time-to-digital converter; and custom digitizing electronics to perform deserialization, demodulation, clock recovery, and forward error correction with a powerful serially-concatenated pulse-position-modulation turbo code. We show error-free data communication performance up to the maximum required data rate of 267 Mb/s.
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.
We present a field-programmable gate array (FPGA) implementation of a single photon-counting receive modem for a pulse position modulated signal. The modem is compliant with the Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard and is capable of a maximum data rate of 267 Mbps. The system is designed on a commercial off-the-shelf FPGA platform and utilizes superconducting nanowire single photon counting detectors, analog to digital converters (ADC s) to sample the detectors, and two FPGAs. Symbol timing recovery, photon counting, convolutional deinterleaving, and codeword synchronization areis performed in the first FPGA. The second FPGA performs iterative decoding on each codeword of the serially concatenated pulse position modulated (SCPPM) signal. A digital filter is included to compensate for timing jitter of the detector, and the decoder throughput can be modified adjusted through reconfigurable parallelization. The decoder also implements a resource-efficient, algorithmic polynomial interleaver and deinterleaver. Both FPGAs can be reconfigured to switch between pulse position modulation (PPM)-16 and PPM-32 with code rates 1/3, 1/2, and 2/3. In this paper, we describe the receiver architecture and FPGA implementation of the timing recovery loop and SCPPM decoder, FPGA utilization for the different modes, and receive modem characterization test results.
The National Aeronautics and Space Administration is developing a photon counting ground receiver for free-space optical communications. The receiver consists of a fiber interconnect, superconducting nanowire single photon counting detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. This receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency standard, which is used in the low photon flux communications regime, including on the upcoming Optical Artemis-2 Orion communications demonstration. The receiver architecture is modular, can be scaled for data rate, and is designed with primarily commercial-off-the-shelf technology. Two fiber interconnect and detector architectures are being prototyped. The first uses a few-mode-fiber coupled to a 16-channel SNSPD array and the second architecture uses a photonic lantern coupled to 7 single-pixel SNSPDs. Photon counting, symbol timing recovery, demodulation and decoding is done using several FPGA cards. This presentation describes the unique features of the ground receiver, performance test results, and challenges with using commercial SNSPDs in free-space optical communications.
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.
The High Resolution Mid-Infrared Spectrometer (HIRMES) instrument will fly onboard NASA's airborne Stratospheric Observatory for Infrared Astronomy (SOFIA) in 2019. HIRMES will provide astronomers with a unique observing window (25 122 µm) for exploring the evolution of protoplanetary disks into young solar systems, and the composition of our Solar System. There are two focal plane detector arrays for the instrument: a high-resolution (/ = 100,000) 8x16 detector array with a target noise-equivalent power, NEP 3x10-18 W/Hz; and a low-resolution (/ = 2,000 19,000) 16x64 detector array with a target NEP 2x10-17 W/Hz. The detectors for both of these arrays are superconducting Mo/Au bilayer transition edge sensor (TES) bolometers on thin suspended single-crystal silicon membranes. Here we present our characterization results for the detectors in both arrays, including measurements of thermal conductance with comparison to phonon transport models, saturation power, noise, and array uniformity.
Resonant soft x-ray scattering (RSXS) is a leading probe of valence-band order in materials best known for detecting charge-density-wave order in copper-oxide superconductors. One of the biggest limitations on the RSXS technique is the presence of a severe fluorescence background, which, like the RSXS cross section itself, is enhanced under resonant conditions. This background prevents the study of weak signals such as diffuse scattering from glassy or fluctuating order that is spread widely over momentum space. Recent advances in superconducting transition-edge-sensor (TES) detectors have led to major improvements in energy resolution and detection efficiency in the soft x-ray range. Here, we perform a RSXS study of stripe-ordered La 2 - x Ba x Cu O 4 at the Cu L 3 / 2 edge (932.2 eV) using a TES detector with 1.5-eV resolution, to evaluate its utility for mitigating the fluorescence-background problem. We find that, for suitable degree of detuning from the resonance, the TES rejects the fluorescence background, leading to a five to ten times improvement in the statistical quality of the data compared to an equivalent, energy-integrated measurement. We conclude that a TES introduces a promising method to reducing background in RSXS studies and may lead to discoveries in materials exhibiting valence-band order that is fluctuating or glassy.
Here, our Compton profile measurements of Ti and TiH 2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH 2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.