Search NASA⌕ Search

SEARCH · Search NASA

Results for “Superconducting detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization of the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 145 mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device multiplexer readout. We describe the design, development, and performance of PIPER bolometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization o[ the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 128mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device (SQUID) multiplexer readout. We describe the design, development, and performance of PIPER bo|ometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

SiAl Composite Feedhorn Arrays for Astrophysical Applications: Cryogenic Material Properties

A study investigating the physical properties and use of the SiAl composite Controlled Expansion 7 (CE7) for the packaging of silicon bolometric detectors for millimeter-wave astrophysical applications at cryogenic temperatures is presented. The existing interfaces to such detectors are typically made of either ductile metals or micro-machined silicon. As a composite of Si and Al, we find that CE7 exhibits properties of both in ways that may be advantageous for this application. This exploration of the physical properties of CE7 reveals: (a) superconductivity below a critical transition temperature, T_c ∼ 1.2 K; (b) a thermal contraction profile much closer to Si than metal substrates; (c) the relatively low thermal conductivity anticipated for a superconductor, which can be improved by Au-plating; and (d) the feasibility of machining mechanical features with tolerances of ∼25 µm. We further discuss the use of CE7 in the cosmology large angular scale surveyor telescope array, which deployed CE7 in several of its detector focal planes.

Aamir M. Ali↗

Prototype Magnetic Calorimeter Arrays with Buried Wiring for the Lynx X-Ray Microcalorimeter

Metallic magnetic calorimeter (MMC) technology is a leading contender for detectors for the Lynx X-ray Microcalorimeter, which is an imaging spectrometer consisting of an array of greater than 100,000 pixels. The fabrication of such large arrays presents a challenge when attempting to route the superconducting wiring from the pixels to the multiplexed readout. If the wiring is designed to be planar, then an aggressive, submicron scale wiring pitch has to be employed, which is technically challenging to design and fabricate on account of the requirements of low inductance, low cross-talk, high critical currents and high yield. An alternative way to achieve large scale, high density wiring is through the use of multiple buried metal layers, planarized by Chemical Mechanical Planarization. This approach is well-suited for connecting thousands of pixels on a large focal plane to readout chips, and also for fabricating sensor meander coils with narrow line widths, which helps in increasing the sensor inductance and thus alleviates stray inductance issues associated with the wiring in large size arrays. In this work we describe the fabrication of high sensor inductance MMC arrays implementing Lynx concepts and incorporating multiple layers of buried Nb wiring. The detector array is composed of three sub-arrays with pixels optimized to meet the different science driven performance requirements of Lynx. In two of the sub-arrays we adopt a thermal multiplexing scheme to read out pixels by coupling 25 absorbers to a single sensor through thermal links of varied thermal conductance. We demonstrate the successful fabrication of multi-absorber MMCs with fine pitch pixels in very large size arrays.

Solid-State Physics↗

The Primordial Anisotropy Polarization Pathfinder Array (PAPPA): Instrument Overview and Status

PAPPA is a balloon-based experiment designed to measure the polarization of the Cosmic Microwave Background using candidate technology for an eventual Inflation Probe mission. It will survey a 20 x 20 degree patch of sky with 1 degree angular resolution covering 3 passbands centered at 100,200 and 300 GHz. Detection will be accomplished via antenna-coupled transition edge sensors (TESs) with SQUID-based readouts. In the eventual flight package, band defining filters and MEMS-based polarization modulators will be incorporated into the superconducting microstrip transmission lines that terminate in resistors that are thermally coupled to the TESs. The MEMS switches will allow on-chip polarization modulation that is faster than significant detector gain variations. The initial configuration will incorporate a simplified focal plane augmented by quasioptical polarization modulation. We describe the overall instrument design and present a summary of the current progress.

Chuss, David↗

NbN A/D Conversion of IR Focal Plane Sensor Signal at 10 K

We are implementing a 12 bit SFQ counting ADC with parallel-to-serial readout using our established 10 K NbN capability. This circuit provides a key element of the analog signal processor (ASP) used in large infrared focal plane arrays. The circuit processes the signal data stream from a Si:As BIB detector array. A 10 mega samples per second (MSPS) pixel data stream flows from the chip at a 120 megabit bit rate in a format that is compatible with other superconductive time dependent processor (TDP) circuits being developed. We will discuss our planned ASP demonstration, the circuit design, and test results.

conversion↗

Cosmic Microwave Background Polarization Detector with High Efficiency, Broad Bandwidth, and Highly Symmetric Coupling to Transition Edge Sensor Bolometers

Four probe antennas transfer signals from waveguide to microstrip lines. The probes not only provide broadband impedance matching, but also thermally isolate waveguide and detector. In addition, we developed a new photonic waveguide choke joint design, with four-fold symmetry, to suppress power leakage at the interface. We have developed facilities to test superconducting circuit elements using a cryogenic microwave probe station, and more complete systems in waveguide. We used the ring resonator shown below to measure a dielectric loss tangent < 7x10(exp -4) over 10 - 45 GHz. We have combined component simulations to predict the overall coupling from waveguide modes to bolometers. The result below shows the planar circuit and waveguide interface can utilize the high beam symmetry of HE11 circular feedhorns with > 99% coupling efficiency over 30% fractional bandwidth.

Wollack, E.↗

Characterizing and testing a thermally isolating superconducting link for SAFIRE-like missions

The recent discovery of high temperature ceramic superconductors with transition temperatures above 90 K has opened the possibilities for new space applications. One application is the fabrication of an electrically conducting and thermally isolating electronic link to connect IR detectors to data acquisition electronics on remote sensing platforms. The Spectroscopy of the Atmosphere using Far Infra-Red Emission (SAFIRE) mission is an example of a platform which employs hybrid dewars and combines both mechanical and cryogenic liquid cooling. This new technology is limited by the heat conducted through sensor array leads that connect the electronics (at approximately 80 K) to the sensors (at approximately 4 K). This link must be made of material that has high electrical conductivity and high thermal resistance. The YBa2Cu3O(x) superconductor with a transition temperature, T(sub c), of 93 K can achieve these conflicting requirements. A link with these characteristics will improve the thermal isolation of IR detectors and will increase the lifetime of the cryogen. A reduction of the thermal load due to the link by a factor of four will increase the lifetime of a seven year mission by about one year.

Selim, Raouf L.↗

Optimized Geometry for Superconducting Sensing Coils

An optimized geometry has been proposed for superconducting sensing coils that are used in conjunction with superconducting quantum interference devices (SQUIDs) in magnetic resonance imaging (MRI), magnetoencephalography (MEG), and related applications in which magnetic fields of small dipoles are detected. In designing a coil of this type, as in designing other sensing coils, one seeks to maximize the sensitivity of the detector of which the coil is a part, subject to geometric constraints arising from the proximity of other required equipment. In MRI or MEG, the main benefit of maximizing the sensitivity would be to enable minimization of measurement time. In general, to maximize the sensitivity of a detector based on a sensing coil coupled with a SQUID sensor, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. Simply making the coil larger may increase its self-inductance and does not necessarily increase sensitivity because it also effectively increases the distance from the sample that contains the source of the signal that one seeks to detect. Additional constraints on the size and shape of the coil and on the distance from the sample arise from the fact that the sample is at room temperature but the coil and the SQUID sensor must be enclosed within a cryogenic shield to maintain superconductivity.

Eom, Byeong Ho↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

Construction and testing of the 2.5m mass driver

Presented are the designs used in the construction of the 2.5 m mass driver and the results of the initial testing program. The mass driver consists of equal length sections of acceleration and deceleration each containing 59 drive coils of 13.1 cm caliber. Intermediate energy storage is provided by sector capacitors which are recharged every half cycle by an external power source. The drive coils are individually energized through SCR's with timing supplied by position sensing optical detectors. The drive consists of two phases which operate in quadrature. The initial bucket to be propelled through the mass driver contains two coils of aluminum wire chilled to liquid nitrogen temperatures to momentarily sustain superconducting field intensities. Magnetic flight is generated by eddy current repulsion from six copper guide strips lining the mass driver. Nominal acceleration is 5000 m/sec per sec giving a maximum bucket velocity of 112 m/s.

Snow, W. R.↗

An Array of Frequency Selective Bolometers (FSB) for the Spectral Energy Distribution (SPEED) Camera

The SPEED camera is being developed to study the spectral energy distributions of high redshift galaxies using the Heinrich Hertz Telescope (HHT) in Arizona. SPEED requires a small cryogenic detector array of 2x2 pixels with each pixel having four frequency bands in the 150-350 GHz range. Here we describe the development of the detector array of these high efficiency FSBs. The FSB design provides the multi-pixel multi-spectral band capability required for SPEED in a compact stackable array. The SPEED bolometers will use proximity effect superconducting transition edge sensors as their temperature-sensing element allowing for higher levels of multiplexing in future applications.

Silverberg, R. F.↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.↗

A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator

A document describes a continuous magnetic refrigerator that is suited for cooling astrophysics detectors. This refrigerator has the potential to provide efficient, continuous cooling to temperatures below 50 mK for detectors, and has the benefits over existing magnetic coolers of reduced mass because of faster cycle times, the ability to pump the cooled fluid to remote cooling locations away from the magnetic field created by the superconducting magnet, elimination of the added complexity and mass of heat switches, and elimination of the need for a thermal bus and single crystal paramagnetic materials due to the good thermal contact between the fluid and the paramagnetic material. A reliable, thermodynamically efficient pump that will work at 1.8 K was needed to enable development of the new magnetic refrigerator. The pump consists of two canisters packed with pieces of gadolinium gallium garnet (GGG). The canisters are connected by a superleak (a porous piece of VYCOR glass). A superconducting magnetic coil surrounds each of the canisters. The configuration enables driving of cyclic thermodynamic cycles (such as the sub-Kelvin Active Magnetic Regenerative Refrigerator) without using pistons or moving parts.

Miller, Franklin K.↗

Microcalorimeter Absorber Optimization for 0.2 to 12 keV X-Rays

The Advanced Telescope for High ENergy Astrophysics (ATHENA) mission requires high quantum efficiency (QE) x-ray absorption, >90.6% at 7 keV and low specific heat capacity, 0.731 pJ/K. The designed ATHENA x-ray absorbers are cantilevered square tiles (pitch of 317 microns) of 1.05 μm thick Au and 5.51 μm thick Bi electroplated films supported by stems that connect the absorber to the detector below. We discuss some of the methods used to produce x-ray absorbers meeting these specifications for ATHENA. To tune the thermal conductance of the device and the effect on the normal-to superconducting transition shape, the stems need to be small diameter and can have a weak bottle-neck connection to the substrate. A funnel shape of the stem using a proximity exposed photoresist mold has been developed to improve the strength of the connections. Further requirements on the absorbers include low levels of fine particulate remaining on the substrate after production and zero shorts between absorbers due to incomplete ion milling or trapped fine particular between absorbers. To optimize for post patterning substrate cleanliness and absorber yield, we have examined several methods of absorber fabrication. Three such methods are 1) an ion mill/wet etch combination, 2) a photoresist mold for electroplating followed by wet or dry etch to remove the seed layer, and 3) an electroplating process with leveling to smooth the surface followed by ion mill to separate the absorbers. The different combinations of wet and dry etches lead to different yields and surface appearance of the absorber sidewalls. We present results on the achieved pixel yields and the energy resolution of pixels made with the various fabrication methods. We discuss the impact of absorber patterning method on performance, uniformity, and yield.

Edward J Wassell↗

Ultra-Sensitive Transition-Edge Sensors for the Background Limited Infrared/Sub-mm Spectrograph (BLISS)

We report progress in fabricating ultra-sensitive superconducting transition-edge sensors (TESs) for BLISS. BLISS is a suite of grating spectrometers covering 35-433 micron with R approx. 700 cooled to 50 mK that is proposed to fly on the Japanese space telescope SPICA. The detector arrays for BLISS are TES bolometers readout with a time domain SQUID multiplexer. The required noise equivalent power (NEP) for BLISS is NEP = 10(exp -19) W/Hz(exp 1/2) with an ultimate goal of NEP= 5 x 10(exp -20) W/Hz(exp 1/2) to achieve background limited noise performance. The required and goal response times are tau = 150 ms and tau = 50ms respectively to achieve the NEP at the required and goal optical chop frequency 1-5 Hz. We measured prototype BLISS arrays and have achieved NEP = 6 x 10(exp -18) W/Hz(exp 1/2) and tau = 1.4 ms with a Ti TES (T(sub C) = 565 mK) and NEP approx. 2.5 x 10(exp -19) W/Hz(exp 1/2) and tau approximates 4.5 ms with an Ir TES (T(sub C) = 130 mK). Dark power for these tests is estimated at 1-5 fW.

transition-edge sensors (TESs)↗