Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL CONVECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗

Community Resilience through Low-Temperature Geothermal Reservoir Thermal Energy Storage

Submitted data include simulations related to underground thermal battery (UTB) simulations described in Modeling and efficiency study of large scale underground thermal battery deployment, presented at GRC, October 2021. The UTB is comprised of a tank of water, a helical heat exchanger in the center of tank and connected to a water source heat pump, and a phase change material (PCM). Compared to a conventional VBGHE, the UTB is designed to be installed at a much shallower depth, therefore, with a cheaper cost. In addition, the GSHP efficiency is improved due to natural convection of water and additional load capacity provided by PCM. The goal of this study is to explore factors that may affect the efficiency of large-scale UTB deployment. The simulations found in this submission relate to the report on UTB deployment.

15 GEOTHERMAL ENERGY↗

Operating Hardware Impact on the Heat Transfer Properties of Windows

Despite significant advancements in fenestration technology in the last two decades, the thermal transmittance of fenestration products is still significantly higher than that of walls. This corresponds to 60% of the total energy loss of a modern building envelope through the windows. Hence, further development and improvements of fenestration products are necessary. Increasingly stringent codes and standards for fenestration stimulate industry to work on improved solutions. Thus, it is crucial that assessment techniques are able to account for innovations accurately. The thermal effects of non-continuous hardware in window frames are currently ignored by international rating procedures. A preliminary investigation conducted by our team showed significant performance degradation in two of the three out-opening casement profiles caused by the presence of operating hardware. Frames with the structure made of vinyl and fiberglass consist of many air cavities that are penetrated by operating hardware made of highly conductive materials. In these frames, in order to have an accurate assessment, it may be required to employ three-dimensional modeling due to the convective nature of heat transfer within the cavities. However, in this study, we demonstrate that the three-dimensional (3D) effects of non-continuous hardware can be approximated accurately with simpler two-dimensional (2D) simulations. We then develop a simplified model based on weighted average capable of replacing the time- and computation-intensive 3D simulations with 2D simulations and validate it against market available frames and their corresponding hardware. Validation results show that our approximation technique results in discrepancies lower than 0.05 W/(m2K), or 3% of the total thermal transmittance. Thus, we conclude that simplified 2D simulation models may be used for predicting hardware impact in window frames with reasonable accuracy. As windows and glazing structures are becoming ever better thermally insulated, it is becoming even more important to be able to model the impact of the operating hardware on the total thermal performance in order to design the best windows possible and not let the operating hardware ruin an otherwise well-proven design, which is hence addressed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SAS4A/SASSYS-1 Commercial Grade Dedication Example Report for a Generic Sodium Pool-Type Fast Reactor Application

In the U.S., a key component of the commercialization of advanced reactors is completion of a license application, which must ultimately be approved by the Nuclear Regulatory Commission (NRC). The approval of the license application by the NRC is contingent on satisfactory demonstration of the design basis and the response of the advanced reactor design to transient and accident scenarios using accepted codes and methods. This report describes the qualification and dedication requirements that the advanced reactor safety analysis system software SAS4A/SASSYS-1 are expected to need to fulfill to be used for sodium-cooled pool-type fast reactor licensing. The qualification and dedication requirements are identified through performance critical characteristics and evaluation model acceptance criteria representative of the advanced reactor design considered for licensing. This document captures, additionally, the verification process developed to demonstrate that the software fulfills the qualification and dedication requirements for a generic sodium-cooled pool-type fast reactor as part of the commercial grade dedication process. Like most software that has primarily existed in the research and development space, the most significant challenge facing SAS4A/SASSYS-1 for use in a licensing framework is the availability of a documentation basis describing the code pedigree. SAS4A/SASSYS-1 has been used for licensing of the fast flux test facility (FFTF) and the JOYO sodium-cooled fast reactor in Japan, as well as the design of the CRBR Plant. However, the historical verification and validation (V&V) activities supporting SAS4A/SASSYS-1 development do not align with modern software quality assurance (SQA) and V&V requirements. Two approaches to use of SAS4A/SASSYS-1 in a commercial licensing framework have been identified: commercial-grade dedication (CGD) and software qualification. The methods and requirements prescribed in the ASME NQA-1-2008/2009 Standard and Regulatory Guide 1.203 on the evaluation model development and assessment process (EMDAP) have been used as guidance to define the CGD and qualification processes, respectively. A qualification and dedication requirements matrix has been developed which utilizes fundamental software verification. In this process, software verification is defined as a software quality process aimed at defining software requirement specifications, developing software design documentation, and performing and documenting acceptance testing of the code against requirements. A key element of software qualification and dedication includes determination of software acceptance with respect to critical characteristics relevant to the functional requirements of the software. To assist with identification of cross-cutting transient phenomena and functional requirements, domestic SFR vendor designs have been reviewed to identify a reference SFR design. For this report, the reference design is defined as a pool-type reactor with metal alloy fuel, a liquid-metal intermediate heat transport system, and passive decay heat rejection systems. Given this reference, a series of high-level cross-cutting phenomena was identified for a general class of single-fault undercooling or reactivity insertion transients that scopes the design basis space, with the goal of assisting with prioritization of documentation development efforts for key transient models in SAS: 1) Reactivity feedback response prior to scram; 2) System-wide thermal inertia; 3) Transition in natural circulation flow regime in heat removal systems; 4) Decay heat generation; 5) Steady-state fuel characterization; 5) Clad/fuel behavior at elevated temperatures; 6) Point kinetics and decay heat; 7) Pump coastdown behavior; 8) Core flow redistribution in loss of forced convection; 9) Pool stratification. As a demonstration of CGD of SAS4A/SASSYS-1 for a sodium pool reactor, a software qualification and dedication gap analysis as it relates to code documentation has been performed. This effort leverages the framework established as part of the SAS4A/SASSYS-1 SQA Program. This CGD demonstration provides a framework that vendors can build upon to demonstrate the applicability of the SAS4A/SASSYS-1 software for licensing a sodium-cooled pool-type fast reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monsoonal MCS Initiation, Rainfall, and Diurnal Gravity Waves over the Bay of Bengal: Observation and a Linear Model

Abstract Previous observational studies have indicated that mesoscale convective systems (MCSs) contribute the majority of precipitation over the Bay of Bengal (BoB) during the summer monsoon season, yet their initiation and propagation remain incompletely understood. To fill this knowledge gap, we conducted a comprehensive study using a combination of 20-yr satellite observations, MCS tracking, reanalysis data, and a theoretical linear model. Satellite observations reveal clear diurnal propagation signals of MCS initiation frequency and rainfall from the west coast of the BoB toward the central BoB, with the MCS rainfall propagating slightly slower than the MCS initiation frequency. Global reanalysis data indicate a strong association between the offshore-propagating MCS initiation frequency/rainfall and diurnal low-level wind perturbations, implying the potential role of gravity waves. To verify the hypothesis, we developed a 2D linear model that can be driven by realistic meteorological fields from reanalysis. The linear model realistically reproduces the characteristics of offshore-propagating diurnal wind perturbations. The wind perturbations, as well as the offshore propagation signals of MCS initiation frequency and rainfall, are associated with diurnal gravity waves emitted from the coastal regions, which in turn are caused by the diurnal land–sea thermal contrast. The ambient wind speed and vertical wind shear play crucial roles in modulating the timing, propagation, and amplitude of diurnal gravity waves. Using the linear model and satellite observations, we further show that the stronger monsoonal flows lead to faster offshore propagation of diurnal gravity waves, which subsequently control the offshore propagation signals of MCS initiation and rainfall. Significance Statement Rainfall over the Bay of Bengal (BoB) is primarily contributed by large and organized rainfall systems in the summer monsoon season. During this season, these systems are commonly observed over the east coast of India around midnight, the western BoB in the morning, and the central BoB in the afternoon. This eastward rainfall propagation is confirmed by observations, reanalysis data, and a theoretical model to have a strong association with atmospheric diurnal gravity waves. These waves are caused by land–sea thermal contrast and can trigger rainfall systems over the offshore regions. We also found that the diurnal gravity waves, as well as their triggered rainfall systems, can be greatly modulated by the large-scale monsoonal flows. All the above findings improve our understanding of diurnal rainfall cycle over the BoB and may contribute to the future improvement of rainfall forecast over the region.

Meteorology & Atmospheric Sciences↗

Capacity Design Method for Integrated Convective/Radiant Terminals to Guarantee Overall and Local Environment

To achieve energy efficiency in the operation of heating devices and ensure thermal comfort in indoor environments, the integrated convective/radiant terminals have become an important development direction for heating systems. This study selected a 14 m 2 bedroom hot summer and cold winter region in China as a case study. Computational Fluid Dynamics (CFD) methodology was used to investigate the design of integrated convective/radiant terminals to ensure thermal comfort for both the entire room and partial space. The results indicate that focusing on partial space during the steady-state stage can achieve energy savings of 31.1% compared to guaranteeing the entire room. Additionally, during the start-up stage, there is a significant reduction of convective unit capacity by 17.6% when the start-up time is 15 minutes. These findings provide data support for the design and engineering applications of products of integrated convective/radiant terminals. Besides, the excess convection ratios for the entire room and partial space are specified as 0.69 to 0.80 and 0.73 to 0.83, respectively.

Chi, Junjie↗

A coupled DEM-IMB-LBM model for simulating methane hydrate exploitation involving particle dissolution

The coupled discrete element and lattice Boltzmann method using an immersed moving boundary scheme was extended to simulate methane hydrate exploitation involving mass transport and particle dissolution. In this coupled DEM-IMB-LBM model, a new Dirichlet-type thermal boundary condition is extended to simulate moving curved boundaries with constant concentration. A novel periodic boundary including an efficient searching algorithm for particle contact is proposed to reduce the computational cost and boundary effect. So, this model is validated by two numerical examples: a circular particle with concentration convection-diffusion moving in a horizontal channel and mass transport from a cylinder particle in a simple shear flow. The numerical results obtained from the proposed model agree well with previous studies. To further demonstrate the capacity of the proposed model, simulations of methane hydrate exploitation including two formations in marine sediments are carried out. The numerical results indicate that the coupled DEM-IMB-LBM is not only capable of simulating the dissolution of hydrate particles at the grain level, but also recover the sand erosion and migration process in a fundamental perspective during the methane hydrate exploitation process.

42 ENGINEERING↗

Computational Fluid Dynamics and Heat Transfer Modeling of a Dimpled Heat Exchanger

Multiphysics and analytical calculations were conducted for a heat exchanger with passive, natural circulation flow. A glycol/water working fluid convects the heat to a dimpled heat exchanger shell, which subsequently transfers the heat to the soil, which acts as the ultimate heat sink. Because the system is fully-passive, it is not subject to the expenses, maintenance, and mechanical breakdowns associated with moving parts. Density, heat capacity, and thermal conductivity material properties were measured for various soil samples, and subsequently included as input for the soil heat conduction model. The soil model was coupled to a computational fluid dynamics (CFD) heat exchanger model that included the dynamic Smagorinsky large eddy simulation and k- omega turbulence models. The analysis showed that the fluid dynamics and heat transfer models worked properly, albeit at a slow pace. Nevertheless, the coupled CFD/heat conduction simulation ran long enough to determine a key parameter—the amount of heat conducted from the heat exchanger to the ground. This unique performance value, along with experimental data, was used as input for stand-alone, fast-running CFD models, as well as boundaries to obtain solutions to partial differential equations for soil heat conduction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NRC Multiphysics Analysis Capability Deployment FY21: Part 3

This report details the progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Support for Advanced Non-Light Water Reactors.” The deliverables completed for this report are: Deliverable 1c: the capability to model gas mixtures was added to Pronghorn. A test problem mimicking the conditions achieved in a depressurized loss of forced cooling (DLOFC) event was solved with both RELAP-5 and Pronghorn. Pronghorn employed a finite vol ume method with the Kurganov-Tadmor discretization. The comparison between the mass fraction spatial profiles computed with RELAP-5 and Pronghorn clearly shows the presence of numerical artifacts (i.e., overly diffusive behavior at low Mach numbers). We confirmed that the problem disappears at higher Mach numbers. We recommend future work on the implementation of a low Mach finite volume formulation to better treat low Mach number problems. Deliverable 2a: we demonstrated two approaches to model the radiation/conduction/natural convection heat transfer across a stagnant gas for the PBMR-400 design using Pronghorn. The first approach is based on the net radiation method, which relies on the computation of view factors with the Multiphysics Object-Oriented Simulation Environment (MOOSE) ray tracing capability. The second method is a traditional thermal resistance approach. The test problems include both 2D and 3D geometries. In all cases, the results show very good agreement during a DLOFC transient. This confirms that the faster thermal resistance method produces solutions that are equivalent to the net radiation method for this geometry. Deliverable 3d: we demonstrated the use of the advection kernel for the delayed neutron precursor equation in Griffin with a 2D MSFR model. The results appear physical but further verification is recommended. We also recommend the addition of conjugate heat transfer to compute the temperatures and model the thermomechanic behavior of the reflectors and other structures. Significant memory and performance issues were encountered in the 3D axisymmetric model. Future work is recommended in this area. Task 8g: this task allows multidimensional MOOSE applications to be coupled to system codes (RELAP-7 and SAM). We implemented a faster multiphysics iteration coupling algorithm, which provides an overall 6× acceleration of the 3D-1D coupling of the core multidi- mensional fluid flow solver and the 1D primary and secondary loop model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental investigation of power transient flow boiling

To advance the mechanistic understanding of power transients in flow boiling, experimental investigations are performed to capture the thermal response of four different kinds of cladding materials, including FeCrAls, to Fuchs reactivity initiated accident transients and linear ramp power transients. The transition boiling regime is phenomenologically reflected in power-transient flow boiling, which is different from steady-state boiling. In light of this, the critical heat flux that is usually featured with temperature overshooting does not indicate thermal safety margin of cladding materials as conservatively as the maximum heat flux, which is greater than critical heat flux in the power transient boiling curve. This is physically attributed to the thermal energy deposition on the cladding wall. In addition, the thermal energy released from the cladding wall results in different boiling heat transfer coefficient for the decreasing and increasing power stages respectively during the Fuchs power transient. The maximum heat flux difference gap, which appears due to changes in cladding materials and transient time scales, is appreciable under an intermediate heat convection regime. However, this difference gap is gradually weakened by the progressive increasing of mass flux and/or inlet subcooling due to the enhanced dominance of heat convection over heat conduction. Finally, the small difference gap of maximum heat flux is found to be insignificant under the weak heat convection because of power transient induced annular flow instability.

42 ENGINEERING↗

Entrainment, Detrainment, and Dilution of Dry and Moist Atmospheric Thermals

Here this study examines the entrainment, detrainment, and dilution of dry and moist (cloud) atmospheric thermals in large-eddy simulations. In a neutrally stable environment (with respect to dry dynamics), moist thermals have an increase in radius R with thermal height z t (α ≡ dR/dz t ) about 4 times smaller compared to dry thermals when density stratification is considered and ~2.4 times smaller without density stratification (i.e., applying the Boussinesq approximation). An analytic expression relating α to several dimensionless parameters is derived from the thermal impulse–circulation relation to clarify the factors impacting α. This expression shows that the difference in buoyancy structure between moist and dry thermals, with buoyancy concentrated in the central cores of moist thermals owing to latent heating, explains their smaller spreading rates. Individual contributions of entrainment and detrainment are analyzed using a direct parcel-based approach in the simulations. Moist thermals have similar fractional detrainment but much smaller fractional entrainment rates compared to dry thermals, consistent with the differences in α. Despite having smaller α, moist thermals are similarly dilute (quantified by a passive tracer) as dry thermals because of their greater mixing efficiency with the environment. Thus, moist thermals are substantially dilute but expand much less in size/volume as they rise compared to dry thermals. The α values for moist thermals in (dry) neutral and statically stable environments are similar, but fractional entrainment and especially detrainment rates are greater in the stable environment. Large detrainment rates are associated with a breakdown of the broader thermal vortex ring structure, especially with low environmental relative humidity, attributed in part to evaporation and buoyancy reversal.

54 ENVIRONMENTAL SCIENCES↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Flow Rate Dependent 1D Model for Thermally Stratified Hot-Water Energy Storage

Stratified tank models are used to simulate thermal storage in applications such as residential or commercial hot-water storage tanks, chilled-water storage tanks, and solar thermal systems. The energy efficiency of these applications relates to the system components and the level of stratification maintained during various flow events in the tank. One-dimensional (1D) models are used in building energy simulations because of the short computation time but often do not include flow-rate dependent mixing. The accuracy of 1D models for plug flow, plug flow with axial conduction, and two convection eddy-diffusivity models were compared with experimental data sets for discharging a 50-gal residential tank and recharging the tank with hot water from an external hot-water source. A minimum and maximum relationship for the eddy diffusivity factor were found at Re <2100 and >10,000 for recirculation of hot water to the top of the tank and vertical tubes inletting cold water at the bottom. The root mean square error decreased from >4 °C to near 2 °C when considering flow-based mixing models during heating, while the exponential decay of the eddy diffusion results in a root mean square error reduction of 1 °C for cone-shaped diffusers that begin to relaminarize flow at the inlet.

1D flow model↗

Two-dimensional simulations of internal gravity waves in a $\mathrm{5M_⊙}$ zero-age-main-sequence model

Main-sequence intermediate-mass stars present a radiative envelope that supports internal gravity waves (IGWs). Excited at the boundary with the convective core, IGWs propagate towards the stellar surface and are suspected to impact physical processes such as rotation and chemical mixing. Using the fully compressible time-implicit code MUSIC, we study IGWs in two-dimensional simulations of a zero-age-main-sequence 5 solar mass star model up to 91 percent of the stellar radius with different luminosity and radiative diffusivity enhancements. Our results show that low-frequency waves excited by core convection are strongly impacted by radiative effects as they propagate. This impact depends on the radial profile of radiative diffusivity which increases by almost 5 orders of magnitude between the centre of the star and the top of the simulation domain. In the upper layers of the simulation domain, we observe an increase of the temperature. Our study suggests that this is due to heat added in these layers by IGWs damped by radiative diffusion. We show that non-linear effects linked to large amplitude IGWs may be relevant just above the convective core. Both these effects are intensified by the artificial enhancement of the luminosity and radiative diffusivity, with enhancement factors up to 10 4 times the realistic values. Our results also highlight that direct comparison between numerical simulations with enhanced luminosity and observations must be made with caution. Finally, our work suggests that thermal effects linked to the damping of IGWs could have a non-negligible impact on stellar structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Incorporation of GTR (generation–transport–recombination) in semiconductor simulations

With the emergence of phase change memory, where the devices experience extreme thermal gradients (~100 K/nm) during transitions between low and high resistive states, the study of thermoelectric effects at small scales becomes particularly relevant. We had earlier observed asymmetric melting of self-heated nano-crystalline silicon micro-wires, where current densities of ~10 7 A/cm 2 were forced through the wires by 1 μs, ~30 V pulses. The extreme asymmetry can be explained by the generation of considerable amount of minority carriers, transport under the electric field, and recombination downstream, a heat transfer process we termed as generation–transport–recombination, which is in opposite direction of the electronic-convective heat carried by the majority carriers. Here, we present a full semiconductor physics treatment of this carrier-lattice heat transport mechanism and the contribution of the minority carriers on the evolution of the melt–solid interface, which can be applied to various high-temperature electronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental characterization of extreme temperature granular flows for solar thermal energy transport and storage

High-temperature, dense granular flows along an inclined plane were considered for solar thermal energy transport and storage with sintered bauxite particles. A series of experiments was performed for particle inlet temperatures of ~ 200, 400, 600, and 800 °C to understand the mechanisms of granular flows at extreme temperatures. Mass flow rates were measured using a load cell and free-surface velocities were measured and computed using particle image velocimetry. Surface temperatures were measured using infrared cameras. A significant decrease in steady-state particle mass flow rate was observed with increasing temperature due to changing flow properties. A decrease in bulk particle free-surface velocities was observed at higher temperatures. Free-surface velocity measurement error between experiments were within 20% of the average. The particle surface temperatures decreased from inlet to outlet with larger gradients at higher temperatures observed due to increasing convection and radiative heat losses. Here, a decrease in temperature was observed along the side walls due to a decrease in particle velocities.

14 SOLAR ENERGY↗

Effects of a CFD-improved dimple stepped-lip piston on thermal efficiency and emissions in a medium-duty diesel engine

Diesel piston-bowl shape is a key design parameter that affects spray-wall interactions and turbulent flow development, and in turn affects the engine’s thermal efficiency and emissions. It is hypothesized that thermal efficiency can be improved by enhancing squish-region vortices as they are hypothesized to promote fuel-air mixing, leading to faster heat-release rates. However, the strength and longevity of these vortices decrease with advanced injection timings for typical stepped-lip (SL) piston geometries. Dimple stepped-lip (DSL) pistons enhance vortex formation at early injection timings. Previous engine experiments with such a bowl show 1.4% thermal efficiency gains over an SL piston. However, soot was increased dramatically [SAE 2022-01-0400]. In a previous study, a new DSL bowl was designed using non-combusting computational fluid dynamic simulations. This improved DSL bowl is predicted to promote stronger, more rotationally energetic vortices than the baseline DSL piston: it employs shallower, narrower, and steeper-curved dimples that are placed further out into the squish region. In the current experimental study, this improved bowl is tested in a medium-duty diesel engine and compared against the SL piston over an injection timing sweep at low-load and part-load operating conditions. No substantial thermal efficiency gains are achieved at the early injection timing with the improved DSL design, but soot emissions are lowered by 45% relative to the production SL piston, likely due to improved air utilization and soot oxidation. However, these benefits are lost at late injection timings, where the DSL piston renders a lower thermal efficiency than that of the SL piston. Energy balance analyses show higher wall heat transfer with the DSL piston than with the SL piston despite a 1.3% reduction in the piston surface area. Vortex enhancement may not necessarily lead to improved efficiency as more energetic squish-region vortices can lead to higher convective heat transfer losses.

42 ENGINEERING↗