Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Secondary ion counting for surface-sensitive chemical analysis of organic compounds using time-of-flight secondary ion mass spectroscopy with cluster ion impact ionization

We report suitable secondary ion (SI) counting for surface-sensitive chemical analysis of organic compounds using time-of-flight (TOF) SI mass spectroscopy, based on considerably higher emission yields of SIs induced by cluster ion impact ionization. A SI counting system for a TOF SI mass spectrometer was developed using a fast digital storage oscilloscope, which allows us to perform various types of analysis as all the signal pulses constituting TOF SI mass spectra can be recorded digitally in the system. Effects of the SI counting strategy on SI mass spectra were investigated for C{sub 8} and C{sub 60} cluster ion impacts on an organically contaminated silicon wafer and on polytetrafluoroethylene targets by comparing TOF SI mass spectra obtained from the same recorded signals with different SI counting procedures. Our results show that the use of a counting system, which can cope with high SI yields, is necessary for quantitative analysis of SI mass spectra obtained under high SI yield per impact conditions, including the case of cluster ion impacts on organic compounds.

36 MATERIALS SCIENCE↗

Laser mass-spectrometry for online diagnosis of reactive plasmas with many species

The purpose of this study is to design a diagnostic system for reactive plasma environment by combining molecular-beam time-of-flight (TOF) mass spectroscopy with laser spectroscopy technique. The combination of TOF mass spectrometers and pulsed lasers is favorable in the diagnosis of intermediate species distribution since they allow the simultaneous but separate recording of the spectra of different species. In the plasma system, the intermediate species in electronic ground state or low lying excited state is pumped to higher energy level with resonant laser excitation, and then, the ionization with a second laser system is possible which can readily be detected by the TOF analyzer. The ionization itself is only used as a detection mechanism for the observation of the excitation of these states. In this manner, the population distribution of intermediate species can be determined with state-selective and mass-selective feature. Also, in this article, a flexible data acquisition and automatic control system based on LABVIEW was designed to integrate all the stand-alone measurement instruments including a TOF spectrometer, a laser system, a high performance oscilloscope, and a digital delay generator into a single personal computer-based control unit. Moreover, a virtual Boxcar integrator with hundreds of channels has been developed to enhance the signal while filtering out the random noises. Finally, the many potentials of this technique in the application of plasma diagnosis will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A shock tube with a high-repetition-rate time-of-flight mass spectrometer for investigations of complex reaction systems

A conventional membrane-type stainless steel shock tube has been coupled to a high-repetition-rate time-of-flight mass spectrometer (HRR-TOF-MS) to be used to study complex reaction systems such as the formation of pollutants in combustion processes or formation of nanoparticles from metal containing organic compounds. Opposed to other TOF-MS shock tubes, our instrument is equipped with a modular sampling unit that allows to sample with or without a skimmer. The skimmer unit can be mounted or removed in less than 10 min. Thus, it is possible to adjust the sampling procedure, namely, the mass flux into the ionization chamber of the HRR-TOF-MS, to the experimental situation imposed by species-specific ionization cross sections and vapor pressures. The whole sampling section was optimized with respect to a minimal distance between the nozzle tip inside the shock tube and the ion source inside the TOF-MS. The design of the apparatus is presented and the influence of the skimmer on the measured spectra is demonstrated by comparing data from both operation modes for conditions typical for chemical kinetics experiments. The well-studied thermal decomposition of acetylene has been used as a test system to validate the new setup against kinetics mechanisms reported in literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elimination of ghosting artifacts from wavelength-shifting fiber neutron detectors

Misassignment of neutron position (ghosting) produces artifacts, which have been observed in wavelength-shifting (WLS) fiber detectors developed for time-of-flight (TOF) neutron powder diffraction. In position-sensitive detectors (PSDs) with WLS fiber encoding, thermal and cold neutrons interact with a monolithic 6LiF/ZnS:Ag scintillator screen, and scintillation photons are generated and transported through the crossed fibers to photomultipliers (PMTs). The neutron position is determined by photon counts in PMTs within a preset time window. Ghosting occurs when neutrons hit the group boundaries of two neighboring PMTs for x-position multiplexing, which is modeled as resulting from a long travel length (about 3-5 mm) of a small number of scintillation photons. This model is supported by the change observed in aperture images when the threshold number for photon-pulses was adjusted for a neutron event determination. When the threshold number of photon-pulses was set above 10 for each PMT, the ghost peaks in the aperture images and TOF spectra of powder diffraction were strongly suppressed or completely eliminated, and the intrinsic background levels of the WLS detectors were significantly reduced. Our result indicates that WLS fiber detector is a promising alternative for 3He PSDs for neutron scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring time of flight of fusion products in an inertial electrostatic confinement fusion device for spatial profiling of fusion reactions

A new diagnostic has been developed that uses the time of flight (TOF) of the products from a nuclear fusion reaction to determine the location where the fusion reaction occurred. The TOF diagnostic uses charged particle detectors on opposing sides of the inertial electrostatic confinement (IEC) device that are coupled to high resolution timing electronics to measure the spatial profile of fusion reactions occurring between the two charged particle detectors. This diagnostic was constructed and tested by the University of Wisconsin-Madison Inertial Electrostatic Confinement Fusion Group in the IEC device, HOMER, which accelerates deuterium ions to fusion relevant energies in a high voltage ({approx}100 kV), spherically symmetric, electrostatic potential well [J. F. Santarius, G. L. Kulcinski, R. P. Ashley, D. R. Boris, B. B. Cipiti, S. K. Murali, G. R. Piefer, R. F. Radel, T. E. Radel, and A. L. Wehmeyer, Fusion Sci. Technol. 47, 1238 (2005)]. The TOF diagnostic detects the products of D(d,p)T reactions and determines where along a chord through the device the fusion event occurred. The diagnostic is also capable of using charged particle spectroscopy to determine the Doppler shift imparted to the fusion products by the center of mass energy of the fusion reactants. The TOF diagnostic is thus able to collect spatial profiles of the fusion reaction density along a chord through the device, coupled with the center of mass energy of the reactions occurring at each location. This provides levels of diagnostic detail never before achieved on an IEC device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy setup for pulsed and constant wave X-ray light sources

An apparatus for sub-nanosecond time-resolved ambient-pressure X-ray photoelectron spectroscopy studies with pulsed and constant wave X-ray light sources is presented. A differentially pumped hemispherical electron analyzer is equipped with a delay-line detector that simultaneously records the position and arrival time of every single electron at the exit aperture of the hemisphere with ∼0.1 mm spatial resolution and ∼150 ps temporal accuracy. The kinetic energies of the photoelectrons are encoded in the hit positions along the dispersive axis of the two-dimensional detector. Pump-probe time-delays are provided by the electron arrival times relative to the pump pulse timing. An average time-resolution of (780 ± 20) ps (FWHM) is demonstrated for a hemisphere pass energy E{sub p} = 150 eV and an electron kinetic energy range KE = 503–508 eV. The time-resolution of the setup is limited by the electron time-of-flight (TOF) spread related to the electron trajectory distribution within the analyzer hemisphere and within the electrostatic lens system that images the interaction volume onto the hemisphere entrance slit. The TOF spread for electrons with KE = 430 eV varies between ∼9 ns at a pass energy of 50 eV and ∼1 ns at pass energies between 200 eV and 400 eV. The correlation between the retarding ratio and the TOF spread is evaluated by means of both analytical descriptions of the electron trajectories within the analyzer hemisphere and computer simulations of the entire trajectories including the electrostatic lens system. In agreement with previous studies, we find that the by far dominant contribution to the TOF spread is acquired within the hemisphere. However, both experiment and computer simulations show that the lens system indirectly affects the time resolution of the setup to a significant extent by inducing a strong dependence of the angular spread of electron trajectories entering the hemisphere on the retarding ratio. The scaling of the angular spread with the retarding ratio can be well approximated by applying Liouville's theorem of constant emittance to the electron trajectories inside the lens system. The performance of the setup is demonstrated by characterizing the laser fluence-dependent transient surface photovoltage response of a laser-excited Si(100) sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy

In order to better understand biochemical processes inside an individual cell, it is important to measure the molecular composition at the submicron level. One of the promising mass spectrometry imaging techniques that may be used to accomplish this is Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), using MeV energy heavy ions for excitation. MeV ions have the ability to desorb large intact molecules with a yield that is several orders of magnitude higher than conventional SIMS using keV ions. In order to increase the spatial resolution of the MeV TOF-SIMS system, we propose an independent TOF trigger using a STIM (scanning transmission ion microscopy) detector that is placed just behind the thin transmission target. This arrangement is suitable for biological samples in which the STIM detector simultaneously measures the mass distribution in scanned samples. The capability of the MeV TOF-SIMS setup was demonstrated by imaging the chemical composition of CaCo-2 cells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modified time-of-flight method for precise determination of high speed ratios in molecular beams

Time-of-flight (TOF) is a standard experimental technique for determining, among others, the speed ratio S (velocity spread) of a molecular beam. The speed ratio is a measure for the monochromaticity of the beam and an accurate determination of S is crucial for various applications, for example, for characterising chromatic aberrations in focussing experiments related to helium microscopy or for precise measurements of surface phonons and surface structures in molecular beam scattering experiments. For both of these applications, it is desirable to have as high a speed ratio as possible. Molecular beam TOF measurements are typically performed by chopping the beam using a rotating chopper with one or more slit openings. The TOF spectra are evaluated using a standard deconvolution method. However, for higher speed ratios, this method is very sensitive to errors related to the determination of the slit width and the beam diameter. The exact sensitivity depends on the beam diameter, the number of slits, the chopper radius, and the chopper rotation frequency. We present a modified method suitable for the evaluation of TOF measurements of high speed ratio beams. The modified method is based on a systematic variation of the chopper convolution parameters so that a set of independent measurements that can be fitted with an appropriate function are obtained. We show that with this modified method, it is possible to reduce the error by typically one order of magnitude compared to the standard method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined photoionization time-of-flight mass spectrometry and laser absorption spectrometry flash photolysis apparatus for simultaneous determination of reaction rates and product branching

In recent years, predictions of product branching for reactions of consequence to both combustion and atmospheric chemistry have outpaced validating experiments. An apparatus is described that aims to fill this void by combining several well-known experimental techniques into one: flash photolysis for radical generation, multiple-pass laser absorption spectrometry (LAS) for overall kinetics measurements, and time-resolved photoionization time-of-flight mass spectrometry (PI TOF-MS) for product branching quantification. The sensitivity of both the LAS and PI TOF-MS detection techniques is shown to be suitable for experiments with initial photolytically generated radical concentrations of ~1 × 10 12 molecules cm -3 . As it is fast (μs time resolution) and non-intrusive, LAS is preferred for accurate kinetics (time-dependence) measurements. By contrast, PI TOF-MS is preferred for product quantification because it provides a near-complete picture of the reactor composition in a single mass spectrum. The value of simultaneous LAS and PI TOF-MS detection is demonstrated for the chemically interesting phenyl radical + propene system.

47 OTHER INSTRUMENTATION↗

Mass measurements of neutron-rich indium isotopes for r -process studies

A new series of neutron-rich indium mass measurements is reported from the TITAN multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS). These mass measurements cover 125-134 In (N = 76–85) and include ground states as well as isomeric states. The masses of nuclei in this region are known to be of great importance for accurately modeling r-process nucleosynthesis, and the significance of the reported neutron-rich indium masses is discussed in this context. Results are compared with earlier experimental data where available as well as theoretical mass models. The measurements reported here include the first mass measurements of 133,134 In, as well as the first direct mass measurement of 132 In. The masses of 125-131 In ground states and several isomers were previously measured to higher precision by Penning trap mass spectrometry, which also resolved some low-lying isomers that could not be resolved in this work. The earlier Penning trap measurements serve as excellent cross-checks for the MR-TOF-MS measurements, and in some cases the MR-TOF-MS measurements improve the literature uncertainties of higher-lying isomer masses and excitation energies. Finally, a new isomeric state for 128 In, recently reported for the first time by the JYFLTRAP group, is also confirmed by the TITAN MR-TOF-MS, with a measured excitation energy of 1813(17) keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise implications for real-space pair distribution function modeling of effects intrinsic to modern time-of-flight neutron diffractometers

Total scattering and pair distribution function (PDF) methods allow for detailed study of local atomic order and disorder, including materials for which Rietveld refinements are not traditionally possible (amorphous materials, liquids, glasses and nanoparticles). With the advent of modern neutron time-of-flight (TOF) instrumentation, total scattering studies are capable of producing PDFs with ranges upwards of 100–200 Å, covering the correlation length scales of interest for many materials under study. Despite this, the refinement and subsequent analysis of data are often limited by confounding factors that are not rigorously accounted for in conventional analysis programs. Furthermore, while many of these artifacts are known and recognized by experts in the field, their effects and any associated mitigation strategies largely exist as passed-down `tribal' knowledge in the community, and have not been concisely demonstrated and compared in a unified presentation. This article aims to explicitly demonstrate, through reviews of previous literature, simulated analysis and real-world case studies, the effects of resolution, binning, bounds, peak shape, peak asymmetry, inconsistent conversion of TOF to d spacing and merging of multiple banks in neutron TOF data as they directly relate to real-space PDF analysis. Suggestions for best practice in analysis of data from modern neutron TOF total scattering instruments when using conventional analysis programs are made, as well as recommendations for improved analysis methods and future instrument design.

36 MATERIALS SCIENCE↗

Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications

Purpose: Metal package photomultiplier tubes (PMTs) with a metal channel dynode structure have several advanced features for devising such time-of-flight (TOF) and high spatial resolution positron emission tomography (PET) detectors, thanks to their high packing density, large effective area ratio, fast time response, and position encoding capability. Here, we report on an investigation of new metal package PMTs with high quantum efficiency (QE) for high-resolution PET and TOF PET detector modules. Methods: The latest metal package PMT, the Hamamatsu R11265 series, is served with two kinds of photocathodes that have higher quantum efficiency than normal bialkali (typical QE ≈ 25%), super bialkali (SBA; QE ≈ 35%), and ultra bialkali (UBA; QE ≈ 43%). In this study, the authors evaluated the performance of the new PMTs with SBA and UBA photocathodes as a PET detector by coupling various crystal arrays. They also investigated the performance improvements of high QE, focusing in particular on a block detector coupled with a lutetium-based scintillator. A single 4 × 4 × 10 mm{sup 3} LYSO, a 7 × 7 array of 3 × 3 × 20 mm{sup 3} LGSO, a 9 × 9 array of 1.2 × 1.2 × 10 mm{sup 3} LYSO, and a 6 × 6 array of 1.5 × 1.5 × 7 mm{sup 3} LuYAP were used for evaluation. All coincidence data were acquired with a DRS4 based fast digitizer. Results: This new PMT shows promising crystal positioning accuracy, energy and time discrimination performance for TOF, and high-resolution PET applications. The authors also found that a metal channel PMT with SBA was enough for both TOF and high-resolution application, although UBA gave a minor improvement to time resolution. However, significant performance improvement was observed in relative low light output crystals (LuYAP) coupled with UBA. Conclusions: The results of this study will be of value as a useful reference to select PMTs for high-performance PET detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Sensitivity estimation in time-of-flight list-mode positron emission tomography

Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

60 APPLIED LIFE SCIENCES↗

Construction of the optical part of a time-of-flight detector prototype for the AFP detector

We present the construction of the optical part of the ToF (time-of-flight) subdetector prototype for the AFP (ATLAS Forward Proton) detector. The ToF detector in conjunction with a 3D silicon pixel tracker will tag and measure protons originating in central exclusive interactions p + p → p + X + p, where the two outgoing protons are scattered in the very forward directions. The ToF is required to reduce so-called pileup backgrounds that arise from multiple proton interactions in the same bunch crossing at high luminosity. The background can fake the signal of interest, and the extra rejection from the ToF allows the proton tagger to operate at the high luminosity required for measurement of the processes. The prototype detector uses fused silica bars emitting Cherenkov radiation as a relativistic particle passes through it. Finally, the emitted Cherenkov photons are detected by a micro-channel plate multi-anode Photomultiplier Tube (MCP-PMT) and processed by fast electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope

From neutron user principal investigator: We kindly request the public release of three neutron imaging datasets through ONCat. All datasets were collected from two forensic specimens, B12W and M8N, sectioned from zinc-filled steel-wire sockets recovered from the collapsed Arecibo Telescope. The dataset titled “Neutron radiographs of B12W and M8N socket sections of the Arecibo telescope” contains normalized two-dimensional (2D) neutron radiographs of the specimens, showing the geometry and spatial distribution of the steel wires embedded within the zinc matrix, as well as internal features such as voids and cracks. The dataset titled “Neutron computed tomography of B12W and M8N socket sections of the Arecibo telescope” contains normalized 2D neutron projection images acquired over a range of specimen rotation angles for one selected region of each specimen. These projection images were used to reconstruct three-dimensional (3D) tomographic volumes that reveal the embedded-wire geometry and internal defects. The dataset titled “Bragg edge imaging (BEI) of B12W and M8N socket sections of the Arecibo telescope” contains six time-of-flight (TOF) neutron imaging datasets, three from each specimen, acquired at regions of interest selected based on the radiographs. The spatially resolved 2D TOF images show the zinc matrix and embedded steel wires, and the wavelength-dependent neutron transmission data were used to characterize crystallographic texture within the zinc. All components and their condition are in the public domain as they are the property of the National Science Foundation (NSF). The neutron imaging data, part geometries, and detailed forensic information have been widely published in the Arecibo Telescope Collapse Forensic Report by Thornton Tomasetti Engineers and others (NASA report and NASEM report).

Bilheux, Hassina↗

High-speed digitization readout of silicon photomultipliers for time of flight positron emission tomography

We report on work to develop a system with about 100 picoseconds (ps) time resolution for time of flight positron emission tomography [TOF-PET]. The chosen photo detectors for the study were Silicon Photomultipliers (SiPM's). This study was based on extensive experience in studying timing properties of SiPM's. The readout of these devices used the commercial high speed digitizer DRS4. We applied different algorithms to get the best time resolution of 155 ps Guassian (sigma) for a LYSO crystal coupled to a SiPM. We consider the work as a first step in building a prototype TOF-PET module. The field of positron-emission-tomography (PET) has been rapidly developing. But there are significant limitations in how well current PET scanners can reconstruct images, related to how fast data can be acquired, how much volume they can image, and the spatial and temporal resolution of the generated photons. Typical modern scanners now include multiple rings of detectors, which can image a large volume of the patient. In this type of scanner, one can treat each ring as a separate detector and require coincidences only within the ring, or treat the entire region viewed by the scanner as a single 3 dimensional volume. This 3d technique has significantly better sensitivity since more photon pair trajectories are accepted. However, the scattering of photons within the volume of the patient, and the effect of random coincidences limits the technique. The advent of sub-nanosecond timing resolution detectors means that there is potentially much better rejection of scattered photon events and random coincidence events in the 3D technique. In addition, if the timing is good enough, then the origin of photons pairs can be determined better, resulting in improved spatial resolution - so called 'Time-of-Flight' PET, or TOF-PET. Currently a lot of activity has occurred in applications of SiPMs for TOF-PET. This is due to the devices very good time resolution, low profile, lack of high voltage needed, and their non-sensitivity to magnetic fields. While investigations into this technique have begun elsewhere, we feel that the extensive SiPM characterization and data acquisition expertise of Fermilab, and the historical in-depth research of PET imaging at University of Chicago will combine to make significant strides in this field. We also benefit by a working relationship with the SiPM producer STMicroelectronics (STM).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FINAL REPORT

Excellent progress was made in standardizing three complementary methods: Magnetic resonance imaging, x-ray micro CT, and MALDI imaging linear ion trap mass spectroscopy to image biomass and chemical, anatomical and functional changes that occur during pretreatment and hydrolysis. Magnetic resonance microscopy provides excellent images with as low as 5 uM resolution with hydrated biomass samples. We visualized dramatic changes in signal associated with the hydrolysis of the carbohydrates by strong acids. Quantitative diffusion approaches were used to probe more subtle structural changes in biomass. Diffusion tensor calculations reflect diffusion anisotropy and fractional anisotropy maps clearly show the longer range diffusion within the vessels compared to within the fiber cells. The diffusion is increased along the cell walls of the vessels. Suggesting that further research with NMR imaging should be pursued. X-ray CT provides excellent images at as low as 3.5 uM resolution from dried biomass. Small increases in surface area, and decreases in local density have been quantified in with wood after mild pretreatments; these changes are expected to be underestimates of the hydrated wood, due to the ~12% shrinkage that occurs upon drying untreated wood. MALDI-MS spectra show high ion intensities at most mass to charge ratios in untreated and pretreated woody material. MALDI-MSn is required to improve specificity and reduce background for imaging. MALDI-TOF is not specific enough for carbohydrate identification. Using MALDI-LIT/MSn we can readily identify oligomeric glucans and xylans and their fragmentation patterns as well as those of the glucuronic acid side chains of birch 4-O-methyl glucuronxylan. Imaging of glucan and xylan oligomers show that many contain isobaric ions with different distributions, indicating again that MSn is needed for accurate imaging of lignocellulosic materials. We are now starting to integrate the three imaging methods by using the same set of biomass samples imaged with all three methods, and using common analytical software to quantify parameters from the three dimensional images. In addition to the proposed experiments, we conducted imaging studies with a novel TOF-SIMS instrument available through collaborations with the AMOLF goup led by Ron Heeren at the FOM Institute in Amersterdam, Netherlands. ToF-SIMS was used to image intact cross sections of Populus stems with high spatial resolution, chemically selectivity. ToF-SIMS images were correlated with fluorescence microscopy which allowed for more positive ion identification.

09 BIOMASS FUELS↗