Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

318 records · Page 18

Temperature Dependence of Ar{sub n}{sup +} Cluster Backscattering from Polymer Surfaces: a New Method to Determine the Surface Glass Transition Temperature

In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to study the intensity variations of the backscattered Ar{sub n}{sup +} clusters as a function of temperature for several amorphous polymer surfaces (polyolefins, polystyrene, and polymethyl methacrylate). For all these investigated polymers, our results show a transition of the ratio Ar{sub 2}{sup +}/(Ar{sub 2}{sup +} + Ar{sub 3}{sup +}) when the temperature is scanned from –120 °C to +125 °C (the exact limits depend on the studied polymer). This transition generally spans over a few tens of degrees and the temperature of the inflection point of each curve is always lower than the bulk glass transition temperature (T{sub g}) reported for the considered polymer. Due to the surface sensitivity of the cluster backscattering process (several nanometers), the presented analysis could provide a new method to specifically evaluate a surface transition temperature of polymers, with the same lateral resolution as the gas cluster beam. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three Dimensional Structures of Particles Recovered from the Asteroid Itokawa by the Hayabusa Mission and a Role of X-Ray Microtomography in the Preliminary Examination

Particles of regolith on S-type Asteroid 25143 Itokawa were successfully recovered by the Hayabusa mission of JAXA (Japan Aerospace Exploration Agency). Near-infrared spectral study of Itokawa s surface indicates that these particles are materials similar to LL5 or LL6 chondrites. High-resolution images of Itokawa's surface suggest that they may be breccias and some impact products. At least more than 1500 particles were identified as Itokawa origin at curation facility of JAXA. Preliminary analysis with SEM/EDX at the curation facility shows that they are roughly similar to LL chondrites. Although most of them are less than 10 micron in size, some larger particles of about 100 micron or larger were also identified. A part of the sample (probably several tens particles) will be selected by Hayabusa sample curation team, and sequential examination will start from January 2011 by Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). In mainstream of the analytical flow, each particle will be examined by microtomography, XRD and XRF first as nondestructive analyses, and then the particle will be cut by an ultra-microtome and examined by TEM, SEM, EPMA, SIMS, PEEM/XANES, and TOF-SIMS sequentially. Three-dimensional structures of Itokawa particles will be obtained by microtomography sub-team of HASPET. The results together with XRD and XRF will be used for design of later destructive analyses, such as determination of cutting direction and depth, to obtain as much information as possible from small particles. Scientific results and a role of the microtomography in the preliminary examination will be presented.

Tsuchiyama, A.↗

Versatile high-repetition-rate phase-locked chopper system for fast timing experiments in the vacuum ultraviolet and x-ray spectral region

A novel light chopper system for fast timing experiments in the vacuum-ultraviolet (VUV) and x-ray spectral region has been developed. It can be phase-locked and synchronized with a synchrotron radiation storage ring, accommodating repetition rates in the range of {approx}8 to {approx}120 kHz by choosing different sets of apertures and subharmonics of the ring frequency (MHz range). Also the opening time of the system can be varied from some nanoseconds to several microseconds to meet the needs of a broad range of applications. Adjusting these parameters, the device can be used either for the generation of single light pulses or pulse packages from a microwave driven, continuous He gas discharge lamp or from storage rings which are otherwise often considered as quasi-continuous light sources. This chopper can be utilized for many different kinds of experiments enabling, for example, unambiguous time-of-flight (TOF) multi-electron coincidence studies of atoms and molecules excited by a single light pulse as well as time-resolved visible laser pump x-ray probe electron spectroscopy of condensed matter in the valence and core level region.

43 PARTICLE ACCELERATORS↗

High-resolution neutron time-of-flight measurements for light water at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory

Series of light water inelastic neutron scattering experiments have been made at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) covering temperatures ranging from 295 K to 600 K and pressures of 1 bar and 150 bar. The temperatures and pressures ranges correspond to that of pressurized light water reactors. The inelastic scattering measurements will help the development of light water thermal scattering kernels, also known as S (α,β) thermal scattering law (TSL), in a consistent fashion given the amount and the quality of the measured data. Light water thermal scattering evaluations available in existing nuclear data libraries have certain limitations and pitfalls. This paper introduces the state of the art of the light water thermal scattering cross-section data not only for room temperature but as well as for reactor operating temperatures, i.e. 550 - 600 K. During the past few years there has been a renewed interest in re-investigating the existing TSL models and utilize the recent experimental data or perform molecular dynamics simulations. It should be pointed out that no single TSL evaluation is based entirely on experimental data and one has to rely on TSL models or a combination of both. New TOF measurement of light water at the SNS, with a detailed description of the experimental setup, measurement conditions, and the associated foreseen results is presented in this paper. The analysis of the experimental data would help in validating the existing approach based on old experimental data or based on molecular dynamic simulations using classical water models, knowledge of which is very important to generate TSL libraries at reactor operating conditions.

Leal, Luiz C.↗

The Spatial Distribution of Soluble Organic Matter and Their Relationship to Minerals in the Asteroid (162173) Ryugu

We performed in-situ analysis on a ~1 mm-sized grain A0080 returned by the Hayabusa2 spacecraft from near-Earth asteroid (162173) Ryugu to investigate the relationship of soluble organic matter (SOM) to minerals. Desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) imaging mapped more than 200 CHN, CHO, CHO–Na (sodium adducted), and CHNO soluble organic compounds. A heterogeneous spatial distribution was observed for different compound classes of SOM as well as among alkylated homologues on the sample surface. The A0080 sample showed mineralogy more like an Ivuna-type (CI) carbonaceous chondrite than other meteorites. It contained two different lithologies, which are either rich (lithology 1) or poor (lithology 2) in magnetite, pyrrhotite, and dolomite. CHN compounds were more concentrated in lithology 1 than in lithology 2; on the other hand, CHO, CHO–Na, and CHNO compounds were distributed in both lithologies. Such different spatial distribution of SOM is likely the result of interaction of the SOM with minerals, during precipitation of the SOM via fluid activity, or could be due to difference in transportation efficiencies of SOMs in aqueous fluid. Organic-related ions measured by time-of-flight secondary ion mass spectrometry (ToF–SIMS) did not coincide with the spatial distribution revealed by DESI-HRMS imaging. This result may be because the different ionization mechanism between DESI and SIMS, or indicate that the ToF–SIMS data would be mainly derived from methanol-insoluble organic matter in A0080. In the Orgueil meteorite, such relationship between altered minerals and SOM distributions was not observed by DESI-HRMS analysis and field-emission scanning electron microscopy, which would result from differences of SOM formation processes and sequent alteration process on the parent bodies or even on the Earth. Alkylated homologues of CHN compounds were identified in A0080 by DESI-HRMS imaging as observed in the Murchison meteorite, but not from the Orgueil meteorite. These compounds with a large C number were enriched in Murchison fragments with abundant carbonate grains. In contrast, such relationship was not observed in A0080, implying different formation or growth mechanisms for the alkylated CHN compounds by interaction with fluid and minerals on the Murchison parent body and asteroid Ryugu.

Ryugu↗

Advances in imaging secondary ion mass spectrometry for biological samples

Imaging mass spectrometry combines the power of mass spectrometry to identify complex molecules based on mass with sample imaging. Recent advances in secondary ion mass spectrometry have improved sensitivity and spatial resolution, so that these methods have the potential to bridge between high-resolution structures obtained by X-ray crystallography and cyro-electron microscopy and ultrastructure visualized by conventional light microscopy. Following background information on the method and instrumentation, we address the key issue of sample preparation. Because mass spectrometry is performed in high vacuum, it is essential to preserve the lateral organization of the sample while removing bulk water, and this has been a major barrier for applications to biological systems. Furthermore, recent applications of imaging mass spectrometry to cell biology, microbial communities, and biosynthetic pathways are summarized briefly, and studies of biological membrane organization are described in greater depth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MeV-SIMS TOF Imaging of Organic Tissue with Continuous Primary Beam

MeV-SIMS is an emerging mass spectrometry imaging method, which utilizes fast, heavy ions to desorb secondary molecules. High yields and low fragmentation rates of large molecules, associated with the electronic sputtering process, make it particularly useful in biomedical research, where insight into distribution of organic molecules is needed. Since the implementation of MeV-SIMS in to the micro-beam line at the tandem accelerator of Jožef Stefan Institute, MeV-SIMS provided some valuable observations on the distribution of biomolecules in plant tissue, as discussed by Jenčič et al. (Nucl. Inst. Methods Phys. Res. B. 371, 205–210, 2016; Nucl. Inst. Methods Phys. Res. B. 404, 140–145, 2017). However, limited focusing ability of the chlorine ion beam only allowed imaging at the tissue level. In order to surpass shortcomings of the existing method, we introduced a new approach, where we employ a continuous, low-current primary beam. In this mode, we bombard thin samples with a steady chlorine ion flux of approx. 5000 ions/s. After desorbing molecules, chlorine ions penetrate through the thinly cut sample and trigger the time-of-flight “start” signal on a continuous electron multiplier detector, positioned behind the sample. Such bombardment is more effective than previously used pulsing-beam mode, which demanded several orders of magnitude higher primary ion beam currents. Sub-micrometer focusing of low-current primary ion beam allows imaging of biological tissue on a subcellular scale. Simultaneously, new time-of-flight acquisition approach also improves mass resolution by a factor of 5. Within the article, we compare the performance of both methods and demonstrate the application of continuous mode on biological tissue. We also describe the thin sample preparation protocol, necessary for measurements with low primary ion currents. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Using Time-of-Flight SIMS to Investigate Group V Dopant Distribution in CdTe

Enabling continued development of polycrystalline CdTe solar cells with open-circuit voltages approaching 1 V requires new dopants and processes to increase acceptor concentrations and minority-carrier lifetimes. We have investigated multiple Group V dopants in single- and polycrystalline CdTe materials as well as Cl, using numerous dopant incorporation and activation strategies. The diffusion kinetics and spatial distribution of the dopants are revealed with a combination of 1-D standard depth-profiling and high-resolution 3-D tomography with time-of-flight secondary-ion mass spectrometry. For all cases where the dopant is incorporated during growth, including vapor-transport deposition, closespaced sublimation, and molecular-beam epitaxy, the dopant concentration is not enhanced at grain boundaries. When the dopant is incorporated through a post-growth incorporation process, fast grain-boundary diffusion leads to an enhanced dopant concentration at grain boundaries. Although both methods are applicable, in-situ incorporation offers control of dopants and devices independent of diffusion kinetics, grain structure, and grain-boundary chemistry.

14 SOLAR ENERGY↗

New Developments in Proton Radiography at the Los Alamos Neutron Science Center (LANSCE)

An application of nuclear physics, a facility for using protons for flash radiography, was developed at the Los Alamos Neutron Science Center (LANSCE). Protons have proven far superior to high energy x-rays for flash radiography because of their long mean free path, good position resolution, and low scatter background. Although this facility is primarily used for studying very fast phenomena such as high explosive driven experiments, it is finding increasing application to other fields, such as tomography of static objects, phase changes in materials and the dynamics of chemical reactions. The advantages of protons are discussed, data from some recent experiments will be reviewed and concepts for new techniques are introduced.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Extended Q-Range Small Angle Neutron Scattering Diffractometer at the SNS

The Extended Q-Range Small Angle Neutron Scattering Diffractometer (EQ-SANS) at the Spallation Neutron Source is designed to have wide neutron momentum transfer (Q) coverage, high neutron beam intensity, and good wavelength resolution. In addition, the design and construction of the instrument aim at achieving maximum signal to noise ratio by minimizing the background. The instrument is located on the 60Hz SNS target. It has a primary flight path of 14m. Its secondary flight path varies from ~1m to 10m. One of the key components in the primary flight path is the neutron optics, consisting of a true-curved multi channel beam bender and sections of neutron guides. The optics is optimized to reduce the neutron transport loss to a minimum, thereby maximizing the available flux on sample. It also enables the avoidance of the direct line of sight of the neutron moderator at downstream locations. The instrument has three bandwidth-limiting choppers. These choppers effectively eliminate higher frame neutrons up to ~38 from the beam. A frame overlap mirror further cleans up the beam by reflecting out neutrons whose wavelengths are longer than ~33 . The bandwidth choppers also allow a frame-skipping mode of operation, which enables the EQ-SANS diffractometer to achieve a dynamic Q-range equivalent to that of a similar machine on a 20Hz source. The two-dimensional low-angle detector, based on 3He tube technologies, offers very high counting rates and counting efficiency. Initial operations have shown that the instrument has achieved its best-in-class design requirement.

EQ-SANS↗

{sup 197}Au(n,gamma) cross section in the resonance region

The (n,gamma) cross section of {sup 197}Au has been measured at n{sub T}OF in the resolved resonance region, up to 5 keV, with the aim of improving the accuracy in an energy range where it is not yet considered standard. The measurements were performed with two different experimental setup and detection techniques, the total energy method based on C{sub 6}D{sub 6} detectors, and the total absorption calorimetry based on a 4pi BaF{sub 2} array. By comparing the data collected with the two techniques, two accurate sets of neutron-capture yields have been obtained, which could be the basis for a new evaluation leading to an extended cross-section standard. Overall good agreement is found between the n{sub T}OF results and evaluated cross sections, with some significant exceptions for small resonances. A few resonances not included in the existing databases have also been observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The LED calibration systems for the mDOM and D-Egg sensor modules of the IceCube Upgrade: Design, production, testing and use in module calibration

The IceCube Neutrino Observatory, instrumenting about 1 km 3 of deep, glacial ice at the geographic South Pole, is due to be enhanced with the IceCube Upgrade. The IceCube Upgrade, to be deployed during the 2025/26 Antarctic summer season, will consist of seven new strings of photosensors, densely embedded near the bottom center of the existing array. Aside from a world-leading sensitivity to neutrino oscillations, a primary goal is the improvement of the calibration of the optical properties of the instrumented ice. This calibration will be applied to the entire archive of IceCube data, improving the angular and energy resolution of the detected neutrino events. For this purpose, the Upgrade strings include a host of new calibration devices. Aside from dedicated calibration modules, several thousand LED flashers have been incorporated into the photosensor modules. We describe the design, production, and testing of these LED flashers before their integration into the sensor modules as well as the use of the LED flashers during lab testing of assembled sensor modules.

Analogue electronic circuits↗