Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRACE CONTAMINANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A fundamental approach to adhesion: Synthesis, surface analysis, thermodynamics and mechanics

Several techniques were used to study pretreated Ti 6-4 surfaces including scanning electron microscopy (SEM), electron spectroscopy of chemical analysis (ESCA), and, reflectance visible spectroscopy. Each pretreatment type gave a characteristic surface morphology as seen by SEM. Elemental analysis of the Ti 6-4 surfaces was done using ESCA. Trace residual contaminants from particular chemical pretreatments were identified readily. Results indicate that reflectance visible spectroscopy using indicator dyes placed on Ti 6-4 surfaces appears to be a feasible approach to establish surface acidity. Differences in surface acidity were observed using bromthymol blue on Ti 6-4 surfaces pretreated by two different methods.

Beck, B.↗

Status of the DOE/NASA critical gas turbine R & T Project

The purpose of the DOE/NASA CRT (Critical Research and Technology) Project at the Lewis Research Center is to provide an R&T data base for utility gas turbine systems burning coal-derived fuels. Coal-derived fuels present difficult problems in combustion (because of the high organically-bound nitrogen in the fuel), and materials (because of the trace metal contaminant levels in the fuels, leading to corrosion and deposition in the turbine hot section). The combustion task includes (1) an effort to model the rich-lean combustion process, to predict NOx emissions; (2) a two-stage flame tube experiment to study the effects of combustion operating conditions and fuel properties on NOx conversion; and (3) scaled combustor tests to evaluate the NOx-reduction potential of several staged-combustion concepts. The materials-corrosion resistance effort attacks the problem on three sides.

Clark, J. S.↗

Spectroscopic characterization of titanium 6-4 surfaces after chemical pretreatments

Several techniques have been used to study pretreated Ti 6-4 surfaces including scanning electron microscopy (SEM), electron spectroscopy of chemical analysis (ESCA), and, reflectance visibile spectroscopy. Each pretreatment type gives a characteristic surface morphology as seen by SEM. Elemental analysis of the Ti 6-4 surfaces was done using ESCA. Trace residual contaminants from particular chemical pretreatments are identified readily. Reflectance visible spectroscopy using indicator dyes placed on Ti 6-4 surfaces appears to be a feasible approach to establish surface acidity. Differences in surface acidity have been observed using bromthymol blue on Ti 6-4 surfaces pretreated by two different methods.

Chen, W.↗

Nebulization reflux concentrator

A nebulization reflux concentrator for removing trace gas contaminants from a sample gas is described. Sample gas from a gas supply is drawn by a suction source into a vessel. The gas enters the vessel through an atomizing nozzle, thereby atomizing and entraining a scrubbing liquid solvent drawn through a siphon tube from a scrubbing liquid reservoir. The gas and entrained liquid rise through a concentrator and impinge upon a solvent phobic filter, whereby purified gas exits through the filter housing and contaminated liquid coalesces on the solvent phobic filter and falls into the reservoir.

Collins, V. G.↗

Catalytic oxidation for treatment of ECLSS and PMMS waste streams

It is shown that catalytic oxidation is an effective technique for the removal of trace organic contaminants in a multifiltration potable processor's effluent. Essential elements of this technology are devices that deliver oxygen to the influent, and remove gaseous reaction byproducts from the effluent, via hollow-tube, gas-permeable membranes. Iodine, which poisons existing catalysis, is removed by a small deiodination bed prior to catalytic reactor entrance. The catalyst used is a mixture of Pt and Ru deposited on carbon, operating at 125-160 C and 39-90 psi pressures.

Akse, James R.↗

Regenerative life support technology challenges for the Space Exploration Initiative

Regenerative life support systems have been identified as one of the critical enabling technologies for future human exploration of space. This discipline encompasses processes and subsystems which regenerate the air, water, solid waste, and food streams typical of human habitation so as to minimize the mass and volume of stored consumables which must accompany the humans on a mission. A number of key technology challenges within this broad discipline are described, ranging from the development of new physical, chemical, and biological processes for regenerating the air, water, solid waste, and food streams to the development of improved techniques for monitoring and controlling microbial and trace constituent contamination. A continuing challenge overarching the development of these new technologies is the need to minimize the mass, volume, and electrical power consumption of the flight hardware. More important for long duration exploration missions, however, is the development of highly reliable, long-lived, self- sufficient systems which absolutely minimize the logistics resupply and operational maintenance requirements of the life support system and which ensure human safety through their robust, reliable operating characteristics.

Bilardo, Vincent J., Jr.↗

Evaluation of HAN-TEAN Stabilizers using Microcalorimetry

HAN-TEAN (hydroxylammonium nitrate - triethanolammonium nitrate - in water) is being considered for various propellant applications. This propellant has advantages in terms of insensitivity to impact and fire, low vapor pressure and environmentally benign reaction products. One office concerns with HAN-TEAN is its stability and shelf-life, especially when contaminated with trace metals. Stabilizer systems, consisting of anti-oxidants and/or chealating agents were investigated for their ability to control the decomposition of HAN-TEAN. Isothermal microcalorimetry, an ultrasensitive heat measurement technique, was used to monitor the decomposition of HANTEAN at near ambient temperatures. Isothermal microcalorimetry measures the heat flow from a reaction vessel into a surrounding heat sink. Microcalorimetry is approximately 1,000 times more sensitive than accelerating rate calorimetry (ARC) or differential scanning calorimetry (DSC) for measuring heat flow. Samples of HAN-TEAN containing the stabilizers were spiked with 50 ppm iron and the heat evolution monitored for a period of at least 30 days. Ten stabilizer combinations were tested and the rates of HAN-TEAN decomposition were lowered by 74 to 95 percent in the presence of iron.

Hornung, Steven D.↗

Cabin Air Quality Dynamics On Board the International Space Station

Spacecraft cabin air quality is influenced by a variety of factors. Beyond normal equipment offgassing and crew metabolic loads, the vehicle s operational configuration contributes significantly to overall air quality. Leaks from system equipment and payload facilities, operational status of the atmospheric scrubbing systems, and the introduction of new equipment and modules to the vehicle all influence air quality. The dynamics associated with changes in the International Space Station's (ISS) configuration since the launch of the U.S. Segment s laboratory module, Destiny, is summarized. Key classes of trace chemical contaminants that are important to crew health and equipment performance are emphasized. The temporary effects associated with attaching each multi-purpose logistics module (MPLM) to the ISS and influence of in-flight air quality on the post-flight ground processing of the MPLM are explored.

Perry, J. L.↗

Photocatalytic Coats in Glass Drinking-Water Bottles

According to a proposal, the insides of glass bottles used to store drinking water would be coated with films consisting of or containing TiO2. In the presence of ultraviolet light, these films would help to remove bacteria, viruses, and trace organic contaminants from the water.

Andren, Anders W.↗

Nanoporous Materials in Atmosphere Revitalization

Atmospheric Revitalization (AR) is the term the National Aeronautics and Space Administration (NASA) uses to encompass the engineered systems that maintain a safe, breathable gaseous atmosphere inside a habitable space cabin. An AR subsystem is a key part of the Environmental Control and Life Support (ECLS) system for habitable space cabins. The ultimate goal for AR subsystem designers is to 'close the loop', that is, to capture gaseous human metabolic products, specifically water vapor (H2O) and Carbon dioxide (CO2), for maximal Oxygen (o2) recovery and to make other useful resources from these products. The AR subsystem also removes trace chemical contaminants from the cabin atmosphere to preserve cabin atmospheric quality, provides O2 and may include instrumentation to monitor cabin atmospheric quality. Long duration crewed space exploration missions require advancements in AR process technologies in order to reduce power consumption and mass and to increase reliability compared to those used for shorter duration missions that are typically limited to Low Earth Orbit. For example, current AR subsystems include separate processors and process air flow loops for removing metabolic CO2 and volatile organic tract contaminants (TCs). Physical adsorbents contained in fixed, packed beds are employed in these processors. Still, isolated pockets of high carbon dioxide have been suggested as a trigger for crew headaches and concern persists about future cabin ammonia (NH3) levels as compared with historical flights. Developers are already focused on certain potential advancements. ECLS systems engineers envision improving the AR subsystem by combining the functions of TC control and CO2 removal into a single regenerable process and moving toward structured sorbents - monoliths - instead of granular material. Monoliths present a lower pressure drop and eliminate particle attrition problems that result from bed containment. New materials and configurations offer promise for lowering cabin levels of CO2 and NH3 as well as reducing power requirements and increasing reliability. This chapter summarizes the challenges faced by ECLS system engineers in pursuing these goals, and the promising materials developments that may be part of the technical solution for challenges of crewed space exploration beyond LEO.

Hernandez-Maldonado, J.↗

Evaluating the Adsoptive Capacities of Chemsorb 1000 and Chemsorb 1425

The Air Revitalization Lab at KSC tested Chemsorb 1000 and 1425, two candidate sorbents for use in future air revitalization technologies being evaluated by the ARREM project. Chemsorb 1000 and 1425 are granular coconut-shell activated carbon sorbents produced by Molecular Products, Inc. that may be used in the TCCS. Chemsorb 1000 is a high grade activated carbon for organic vapor adsorption. In contrast, Chemsorb 1425 is a high-grade impregnated activated carbon for adsorption of airborne ammonia and amines. Chemsorb 1000 was challenged with simulated spacecraft gas streams in order to determine its adsorptive capacities for mixtures of volatile organics compounds. Chemsorb 1425 was challenged with various NH3 concentrations to determine its adsorptive capacity.

volatile organic compound (VOC)↗

NASA Advanced Explorations Systems: 2018 Advancements in Life Support Systems

The NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) project strives to develop reliable, energy-efficient, and low-mass spacecraft systems to provide envi-ronmental control and life support systems (ECLSS) critical to enabling long duration human missions beyond low Earth orbit (LEO). Highly reliable, closed-loop life support systems are among the capabilities required for the longer duration human space exploration missions planned in the mid-2020s and beyond. The LSS Project is focused on three life support areas: air revitalization, wastewater processing/water management and environmental monitoring. Building upon the International Space Station (ISS) LSS systems (where applicable), the three-fold mission of the LSS Project is to address discrete LSS technology gaps, to improve the reliability of LSS systems, and to advance LSS systems toward integrated testing aboard the ISS. This paper is a follow on to the AES LSS development status reported in 2017 and provides additional details on the progress made since that publication with specific attention to the status of the Aerosol Sampler ISS Flight Experiment, the Spacecraft Atmosphere Monitor (SAM) Flight Experiment, the Brine Processor Assembly (BPA) Flight Experiment as well as the progress of the terrestrial development in air, water and environmental monitoring technologies.

trace contaminant control↗

Clean is not Sterile: A Planetary Science and Planetary Protection Perspective on Cleanroom Microbiology at NASA

The Astromaterials Acquisition and Curation Office at NASA is responsible for the curation of extraterrestrial samples from NASA’s past and future sample return missions. Our office curates samples from the moon, meteorites, comets, asteroids, cosmic dust and solar wind particles. All these samples are kept in cleanrooms to limit particulate and trace metal contamination, but none of these cleanrooms are specifically designed to control microbial contamination. During the early Apollo missions NASA scientists were very concerned with protecting the Earth from potential microbial contamination from the moon and with protecting the lunar samples from terrestrial microbes. NASA developed specialized equipment and clean rooms to keep these collections pristine. However, as we learned more about the lunar environment our concerns about microbial contamination lessened. Today none of the existing collections have microbial contamination requirements because they are not considered susceptible to microbial alteration under curation conditions (e.g. solar wind samples, and lunar samples) or have already been contaminated by terrestrial biology (meteorites collected in Antarctica). However, NASA’s OSIRIS-REx mission will land in 2023 with samples from a carbon rich asteroid that will be susceptible to microbial alteration. The Perseverance rover on Mars will begin to collect and cache samples that will be returned to Earth as soon as 2031. Martian samples may contain signs of extraterrestrial life and will have to be treated like the early Apollo samples. Martian samples will be isolated to protect the Earth, and must also be protected from terrestrial contamination. I will present microbial monitoring data from existing NASA cleanrooms and discuss how NASA is planning to use techniques from the pharmaceutical industry and academia to design new laboratories and equipment that will protect astromaterials and the earth from unwanted microbial contamination. I will also discuss a project to sample the external microbiome of the International Space Station. Results from this research will be used to design facilities for use on Mars that limit the amount of contamination associated with crewed missions.

Aaron B Regberg↗

Non-Protein Amino Acids Identified in Carbon-Rich Hayabusa Particles

Amino acid abundances in acid-hydrolyzed hot water extracts of gold foils containing five Category 3 (carbon-rich) Hayabusa particles were studied using liquid chromatography with tandem fluorescence and accurate mass detection. Initial particle analyses using field emission scanning electron microscopy with energy-dispersive X-ray spectrometry indicated that the particles were composed mainly of carbon. Prior to amino acid analysis, infrared and Raman microspectroscopy showed some grains possessed primitive organic carbon. Although trace terrestrial contamination, namely L-protein amino acids, was observed in all Hayabusa extracts, several terrestrially uncommon non-protein amino acids were also identified. Some Hayabusa particles contained racemic (D≈L) mixtures of the non-protein amino acids β-aminoisobutyric acid (β-AIB) and β-amino-n-butyric acid (β-ABA) at low abundances ranging from 0.09 to 0.31 nmol g −1 . Larger abundances of the non-protein amino acid β-alanine (9.2 nmol g −1 , ≈4.5 times greater than background levels) were measured in an extract of three Hayabusa particles. This β-alanine abundance was ≈6 times higher than that measured in an extract of a CM2 Murchison grain processed in parallel. The comparatively high β-alanine abundance is surprising as asteroid Itokawa is similar to amino acid-poor LL ordinary chondrites. Elevated β-alanine abundances and racemic β-AIB and β-ABA in Hayabusa grains suggested these compounds have non-biological and plausibly non-terrestrial origins. These results are the first evidence of plausibly extraterrestrial amino acids in asteroid material from a sample-return mission and demonstrate the capabilities of the analytical protocols used to study asteroid Ryugu and Bennu samples returned by the JAXA Hayabusa2 and NASA OSIRIS-REx missions, respectively.

Eric T. Parker↗

Two Catalysts for Selective Oxidation of Contaminant Gases

Two catalysts for the selective oxidation of trace amounts of contaminant gases in air have been developed for use aboard the International Space Station. These catalysts might also be useful for reducing concentrations of fumes in terrestrial industrial facilities especially facilities that use halocarbons as solvents, refrigerant liquids, and foaming agents, as well as facilities that generate or utilize ammonia. The first catalyst is of the supported-precious-metal type. This catalyst is highly active for the oxidation of halocarbons, hydrocarbons, and oxygenates at low concentrations in air. This catalyst is more active for the oxidation of hydrocarbons and halocarbons than are competing catalysts developed in recent years. This catalyst completely converts these airborne contaminant gases to carbon dioxide, water, and mineral acids that can be easily removed from the air, and does not make any chlorine gas in the process. The catalyst is thermally stable and is not poisoned by chlorine or fluorine atoms produced on its surface during the destruction of a halocarbon. In addition, the catalyst can selectively oxidize ammonia to nitrogen at a temperature between 200 and 260 C, without making nitrogen oxides, which are toxic. The temperature of 260 C is higher than the operational temperature of any other precious-metal catalyst that can selectively oxidize ammonia. The purpose of the platinum in this catalyst is to oxidize hydrocarbons and to ensure that the oxidation of halocarbons goes to completion. However, the platinum exhibits little or no activity for initiating the destruction of halocarbons. Instead, the attack on the halocarbons is initiated by the support. The support also provides a high surface area for exposure of the platinum. Moreover, the support resists deactivation or destruction by halogens released during the destruction of halocarbons. The second catalyst is of the supported- metal-oxide type. This catalyst can selectively oxidize ammonia to nitrogen at temperatures up to 400 C, without producing nitrogen oxides. This catalyst converts ammonia completely to nitrogen, even when the concentration of ammonia is very low. No other catalyst is known to oxidize ammonia selectively at such a high temperature and low concentration. Both the metal oxide and the support contribute to the activity and selectivity of this catalyst.

Wright, John D.↗

Syringe filtration methods for examining dissolved and colloidal trace element distributions in remote field locations

It is well-established that sampling and sample processing can easily introduce contamination into dissolved trace element samples if precautions are not taken. However, work in remote locations sometimes precludes bringing bulky clean lab equipment into the field and likewise may make timely transport of samples to the lab for processing impossible. Straightforward syringe filtration methods are described here for collecting small quantities (15 mL) of 0.45- and 0.02-microm filtered river water in an uncontaminated manner. These filtration methods take advantage of recent advances in analytical capabilities that require only small amounts of waterfor analysis of a suite of dissolved trace elements. Filter clogging and solute rejection artifacts appear to be minimal, although some adsorption of metals and organics does affect the first approximately 10 mL of water passing through the filters. Overall the methods are clean, easy to use, and provide reproducible representations of the dissolved and colloidal fractions of trace elements in river waters. Furthermore, sample processing materials can be prepared well in advance in a clean lab and transported cleanly and compactly to the field. Application of these methods is illustrated with data from remote locations in the Rocky Mountains and along the Yukon River. Evidence from field flow fractionation suggests that the 0.02-microm filters may provide a practical cutoff to distinguish metals associated with small inorganic and organic complexes from those associated with silicate and oxide colloids.

Colloids/analysis↗