Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Calibrating Atmospheric Delay for the Cassini Gravitational Wave Experiment

The Cassini spacecraft together with one of the stations of the Deep Space Network (DSN) have been instrumented to carry out extremely precise Doppler tracking that will be used to search for the direct evidence of Gravitational radiation passing through our solar system. The two-way communications link between the ground antenna and the spacecraft constitute an "antenna" for gravitational waves that would perturb the phase of the RF signal in the link. The experiments will be carried out during the long cruise phase of the spacecraft on its journey to Saturn and will be sensitive to gravitational wave perturbations larger than the noise level fluctuations of 3 x 10(exp -15) as measured in the Allan Standard Deviation domain. The use of simultaneous, coherent X- and Ka-Band up and down signals will reduce the errors associated with charged particle fluctuations in the interplanetary medium and Earth's ionosphere to a negligible level. The primary fluctuations in the phase of the signals both to and from the spacecraft are expected to be caused by fluctuations in water vapor in the Earth's atmosphere We have designed and are testing a new atmospheric calibration system (with duplicate components) to sense line-of-sight water vapor and its physical temperature with a goal of calibrating 95% or more of tropospheric path delay fluctuations during the Cassini Gravitational Wave Experiment (GWE). The critical component of the calibration system consists of a newly designed water vapor radiometer having a I degree sensing beamwidth and 0.01 K brightness temperature stability over hour time scales. Auxiliary instrumentation includes a microwave temperature profiler to retrieve the vertical distribution of the vapor physical temperature, and surface meteorology. A detailed error budget has been developed to account for all of the possible sources of error during calibration of the GWE and will be discussed. Two identical calibration systems have been constructed in order to provide capability as well as backup during the actual GWE experiment. We will report on side-by-side testing of the vapor and temperature sensing components of this calibrations system as well as a comparison with a short baseline radio interferometric measurement at our Goldstone complex.

Resch, G. M.↗

Cloud Tolerance of Remote-Sensing Technologies to Measure Land Surface Temperature

Conventional methods to estimate land surface temperature (LST) from space rely on the thermal infrared(TIR) spectral window and is limited to cloud-free scenes. To also provide LST estimates during periods with clouds, a new method was developed to estimate LST based on passive microwave(MW) observations. The MW-LST product is informed by six polar-orbiting satellites to create a global record with up to eight observations per day for each 0.25resolution grid box. For days with sufficient observations, a continuous diurnal temperature cycle (DTC) was fitted. The main characteristics of the DTC were scaled to match those of a geostationary TIR-LST product. This paper tests the cloud tolerance of the MW-LST product. In particular, we demonstrate its stable performance with respect to flux tower observation sites (four in Europe and nine in the United States), over a range of cloudiness conditions up to heavily overcast skies. The results show that TIR based LST has slightly better performance than MW-LST for clear-sky observations but suffers an increasing negative bias as cloud cover increases. This negative bias is caused by incomplete masking of cloud-covered areas within the TIR scene that affects many applications of TIR-LST. In contrast, for MW-LST we find no direct impact of clouds on its accuracy and bias. MW-LST can therefore be used to improve TIR cloud screening. Moreover, the ability to provide LST estimates for cloud-covered surfaces can help expand current clear-sky-only satellite retrieval products to all-weather applications.

polar-orbiting↗

Thin-film temperature sensor.

A new device has been developed for sensing small and rapid temperature changes accompanying biochemical reactions. The active element consists of an evaporated thin-film capacitor having a relatively strong temperature dependence. This dependence is derived from electron trapping effects in the thin amorphous dielectric film. A voltage output of at least 50 mV/deg can be obtained prior to amplification by using a resonant ac bridge circuit operating at 100 kHz. The corresponding noise output for a 10 kHz bandwidth can with an optimum circuit be as low as 4 microvolts. Therefore, the minimum detectable temperature change would be 80 microdegrees at 10 kHz. Rapid thermal response is assured by supporting the thin-film capacitor on a thin anodic tantalum oxide film suspended across an electrolytically etched window in a tantalum foil.

Maserjian, J.↗

Effects of temperature-dependent molecular absorption coefficients on the thermal infrared remote sensing of the earth surface

The effect of temperature-dependent molecular absorption coefficients on thermal infrared spectral signatures measured from satellite sensors is investigated by comparing results from the atmospheric transmission and radiance codes LOWTRAN and MODTRAN and the accurate multiple scattering radiative transfer model ATRAD for different atmospheric profiles. The sensors considered include the operational NOAA AVHRR and two research instruments planned for NASA's Earth Observing System (EOS): MODIS-N (Moderate Resolution Imaging Spectrometer-Nadir-Mode) and ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer). The difference in band transmittance is as large as 6 percent for some thermal bands within atmospheric windows and more than 30 percent near the edges of these atmospheric windows. The effect of temperature-dependent molecular absorption coefficients on satellite measurements of sea-surface temperature can exceed 0.6 K. Quantitative comparison and factor analysis indicate that more accurate measurements of molecular absorption coefficients and better radiative transfer simulation methods are needed to achieve SST accuracy of 0.3 K, as required for global numerical models of climate, and to develop land-surface temperature algorithms at the 1-K accuracy level.

Wan, Zhengming↗

Project ATLANTA (Atlanta Land use Analysis: Temperature and Air Quality): Use of Remote Sensing and Modeling to Analyze How Urban Land Use Change Affects Meteorology and Air Quality Through Time

This paper presents an overview of Project ATLANTA (ATlanta Land use ANalysis: Temperature and Air-quality) which is an investigation that seeks to observe, measure, model, and analyze how the rapid growth of the Atlanta, Georgia metropolitan area since the early 1970's has impacted the region's climate and air quality. The primary objectives for this research effort are: (1) To investigate and model the relationships between land cover change in the Atlanta metropolitan, and the development of the urban heat island phenomenon through time; (2) To investigate and model the temporal relationships between Atlanta urban growth and land cover change on air quality; and (3) To model the overall effects of urban development on surface energy budget characteristics across the Atlanta urban landscape through time. Our key goal is to derive a better scientific understanding of how land cover changes associated with urbanization in the Atlanta area, principally in transforming forest lands to urban land covers through time, has, and will, effect local and regional climate, surface energy flux, and air quality characteristics. Allied with this goal is the prospect that the results from this research can be applied by urban planners, environmental managers and other decision-makers, for determining how urbanization has impacted the climate and overall environment of the Atlanta area. Multiscaled remote sensing data, particularly high resolution thermal infrared data, are integral to this study for the analysis of thermal energy fluxes across the Atlanta urban landscape.

Quattrochi, Dale A.↗

Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment

Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.

Boyle, Robert J.↗

Development of Luminescence Lifetime-Based Surface Temperature Mapping for Environmental Barrier Coatings

Luminescence lifetime-based temperature mapping for thermal barrier coatings (TBCs) has been previously demonstrated up to temperatures approaching 1200 °C. Advantages of this method include insensitivities to reflected radiation and emissivity uncertainties. Because of a push towards greater efficiency turbine engine operation using higher turbine inlet temperatures, there is an ongoing movement from TBC-coated superalloy turbine engine components to SiC/SiC ceramic matrix composite components protected by environmental barrier coatings (EBCs). The useful application of luminescence lifetime-based temperature mapping to EBCs requires a significant increase in high temperature capability from below 1200 °C up into the 1300 to 1500 °C temperature range where the much higher background thermal radiation is a challenging issue. In addition, the luminescing sensing layer must exhibit thermochemical compatibility with the EBC. To meet these requirements, Er-doped Y 2 SiO 5 was selected as the luminescing sensor layer material both for its enhanced temperature sensitivity above 1300 °C and its compatibility with rare-earth disilicate EBC topcoats. Both localized spot temperature measurements as well as luminescence lifetime imaging-based temperature mapping were demonstrated up to 1560 °C for Er-doped Y 2 SiO 5 disks. In addition, temperature mapping capability was demonstrated from a 15 µm thick Er-doped Y 2 SiO 5 layer at the surface of a Sc 2 Si 2 O 7 based EBC topcoat. Both localized spot and temperature mapping by luminescence lifetime imaging were demonstrated up to 1380 °C (upper temperature limit of this slurry-based layered EBC) with excellent suppression of background thermal radiation and no degradation of the Er-doped Y 2 SiO 5 temperature sensing surface layer. The source of the novel enhanced temperature sensitivity above 1300 °C will be discussed as well as a path towards compatibility between sensing layer and EBC topcoat to higher temperatures.

temperature measurement↗

Aircraft-based radiometric imaging of tropospheric temperature and precipitation using the 118.75-GHz oxygen resonance

Passive microwave imaging of O2 emissions using the 118.75-GHz resonance has been investigated for tropospheric and stratospheric remote sensing of atmospheric temperature and precipitation. An imaging millimeter-wave spectrometer (MTS) using eight double-sideband channels centered around the 118.75-GHz resonance, and including a fixed-beam 53.65-GHz radiometer and video camera was constructed. The MTS collected data during 33 flights of the NASA-ER-2 high-altitude aircraft in 1986 during GALE and Cohmex, yielding the first high-spatial-resolution microwave images of atmospheric O2 brightness. The isolated 118-GHz line offers higher spatial resolution and precipitation sensitivity than O2 lines in the 5-mm band near 60 GHz. The brightness temperature perturbations of clouds in nonprecipitating regions are typically twice as large in the 118-GHz channels. However, observations over cirrus anvils show that the 118-GHz brightnesses are not adversely sensitive to some optically opaque cloud cover. Thus these channels are expected to be useful for temperature sounding in the presence of clouds, although retrieval ambiguities can result from variations in the water-vapor profile and surface emissivity.

Gasiewski, A. J.↗

Evapotranspiration and remote sensing

There are three things required for evapotranspiration to occur: (1) energy (580 cal/gm) for the change of phase of the water; (2) a source of the water, i.e., adequate soil moisture in the surface layer or in the root zone of the plant; and (3) a sink for the water, i.e., a moisture deficit in the air above the ground. Remote sensing can contribute information to the first two of these conditions by providing estimates of solar insolation, surface albedo, surface temperature, vegetation cover, and soil moisture content. In addition there have been attempts to estimate precipitation and shelter air temperature from remotely sensed data. The problem remains to develop methods for effectively using these sources of information to make large area estimates of evapotranspiration.

Schmugge, T. J.↗

Fourier transform spectroscopy of the Swan (d(sup 3)pi(sub g) - a(sup 3)pi(sub u)) system of the jet-cooled C2 molecule

The Swan (d(sup 3)pi(sub g) - a(sup 3)pi(sub u)) system of the C2 molecule was produced in a jet-cooled corona excited supersonic expansion of helium using diazoacetonitrile as a percursor molecule. This spectrum was recorded using the McMath Fourier transform spectrometer of the National Solar Observatory at Kitt Peak. A total of nine bands with v prime = 0 to 3 and v prime prime = 0 to 4 in the range 16,570-22,760/cm were observed and rotationally analyzed. The C2 molecules in this source had a rotational temperature of only 90 K so that only the low-J lines were present in the spectrum. In some sense the low temperatures in the jet source simulate conditions in the interstellar medium. The Swan system of C2 was also produced in a composite wall hollow cathode made Al4C3/Cu, and the rotational structure of the 1-0, 2-1, 3-2, 0-0, and 1-1 bands were analyzed. The data obtained from both these spectra were fitted together along with some recently published line positions. The rotational constants, lambda doubling parameters and the vibrational constants were estimated from this global fit. Our work on jet-cooled C2 follows similar work on the violet and red systems of CN. A summary of this CN work is also presented. also presented.

Prasad, C. V. V.↗

Growth Chambers on the International Space Station for Large Plants

The International Space Station (ISS) now has platforms for conducting research on horticultural plant species under LED lighting, and those capabilities continue to expand. The 'Veggie' vegetable production system was deployed to the ISS as an applied research platform for food production in space. Veggie is capable of growing a wide array of horticultural crops. It was designed for low power usage, low launch mass and stowage volume, and minimal crew time requirements. The Veggie flight hardware consists of a light cap containing red (630 nm), blue, (455 nm) and green (530 nm) LEDs. Interfacing with the light cap is an extendable bellows/baseplate for enclosing the plant canopy. A second large plant growth chamber, the Advanced Plant Habitat (APH), is will fly to the ISS in 2017. APH will be a fully controllable environment for high-quality plant physiological research. APH will control light (quality, level, and timing), temperature, CO2, relative humidity, and irrigation, while scrubbing any cabin or plant-derived ethylene and other volatile organic compounds. Additional capabilities include sensing of leaf temperature and root zone moisture, root zone temperature, and oxygen concentration. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs (4100K). There will be several internal cameras (visible and IR) to monitor and record plant growth and operations. Veggie and APH are available for research proposals.

Advanced Plant Habitat↗

Growth Chambers on the International Space Station for Large Plants

The International Space Station (ISS) now has platforms for conducting research on horticultural plant species under LED (Light Emitting Diodes) lighting, and those capabilities continue to expand. The Veggie vegetable production system was deployed to the ISS as an applied research platform for food production in space. Veggie is capable of growing a wide array of horticultural crops. It was designed for low power usage, low launch mass and stowage volume, and minimal crew time requirements. The Veggie flight hardware consists of a light cap containing red (630 nanometers), blue, (455 nanometers) and green (530 nanometers) LEDs. Interfacing with the light cap is an extendable bellowsbaseplate for enclosing the plant canopy. A second large plant growth chamber, the Advanced Plant Habitat (APH), is will fly to the ISS in 2017. APH will be a fully controllable environment for high-quality plant physiological research. APH will control light (quality, level, and timing), temperature, CO2, relative humidity, and irrigation, while scrubbing any cabin or plant-derived ethylene and other volatile organic compounds. Additional capabilities include sensing of leaf temperature and root zone moisture, root zone temperature, and oxygen concentration. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs (4100K). There will be several internal cameras (visible and IR) to monitor and record plant growth and operations. Veggie and APH are available for research proposals.

Veggie↗

Two Fiber Optical Fiber Thermometry

An optical fiber thermometer consists of an optical fiber whose sensing tip is given a metallic coating. The sensing tip of the fiber is essentially an isothermal cavity, so the emission from this cavity will be approximately equal to the emission from a blackbody. Temperature readings are obtained by measuring the spectral radiative heat flux at the end of the fiber at two wavelengths. The ratio of these measurements and Planck's Law are used to infer the temperature at the sensing tip. Optical fiber thermometers have high accuracy, excellent long-term stability and are immune to electromagnetic interference. In addition, they can be operated for extended periods without requiring re-calibration. For these reasons. it is desirable to use optical fiber thermometers in environments such as the International Space Station. However, it has recently been shown that temperature readings are corrupted by emission from the fiber when extended portions of the probe are exposed to elevated temperatures. This paper will describe several ways in which the reading from a second fiber can be used to correct the corrupted temperature measurements. The accuracy and sensitivity to measurement uncertainty will be presented for each method.

Jones, Mathew R.↗

Roman Space Telescope – Demonstration of Integrated Thermal Control System Test for the Optical Telescope Assembly

On-orbit optical stability of the Nancy Grace Roman Space Telescope (RST) is a key requirement that enables multiple science objectives and drives multiple aspects of telescope design and analysis. Thermoelastic changes are typically large contributors to optical instability, and both extremely low CTE materials and extremely stable temperatures are needed to achieve the RST optical stability requirements. We will present the results from a test that demonstrated the L3Harris capability to sense and control temperatures to milli-kelvin levels of stability across a range of operating temperatures.

Peter Miller↗

Remote sensing of row crop structure and component temperatures using directional radiometric temperatures and inversion techniques

A physically based sensor response model of a row crop was used as the mathematical framework from which several inversion strategies were tested for extracting row structure information and component temperatures using a series of sensor view angles. The technique was evaluated on ground-based radiometric thermal infrared data of a cotton row crop that covered 48 percent of the ground in the vertical projection. The results showed that the accuracies of the predicted row heights and widths, vegetation temperatures, and soil temperatures of the cotton row crop were on the order of 5 cm, 1 deg, and 2 deg C, respectively. The inversion techniques can be applied to directional sensor data from aircraft platforms and even space platforms if the effects of atmospheric absorption and emission can be corrected. In theory, such inversion techniques can be applied to a wide variety of vegetation types and thus can have significant implications for remote sensing research and applications in disciplines that deal with incomplete vegetation canopies.

Kimes, D. S.↗

Procedures for analysis of spatial relationships among ship survey data and sea surface temperature

The establishment of a limited spatial data base for the U.S. eastern seaboard vicinity is discussed along with the demonstration of computer assisted analysis techniques for investigating spatial patterns and relationships among ship survey data and remotely sensed sea surface temperature. Ship survey variables included concentrations of two zooplankton, two icthyoplankton, and two fish species, in addition to physical data of depth to bottom and surface and bottom water temperatures. Continuous spatial distributions of these data were created by both weighted nearest neighbor and iterative smoothing interpolation techniques. Maps of surface water temperature were created by digitizing GOES satellite images. All mapped data were spatially registered by conversion of latitude and longitude coordinates to rotated Lambert conic conformal rectilinear coordinates and stored in grid format of approximately one hundred square kilometers per cell. The analysis of these data include the generation of statistical summaries and maps describing the joint occurrence among variables.

Berry, J. K.↗