Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Combining RNA-SEQ Datasets from NASA GENELAB: An Evaluation of Correction Methods

Background: Conducting space biology experiments aboard the International Space Station, particularly those utilizing complex model organisms like mice, is expensive and difficult due to limited crew availability, hardware, and space. As a result, sample numbers from these studies are low, reducing the statistical power of any one experiment. Aggregating spaceflight datasets serves as a method to increase sample numbers, allowing for novel insights through bioinformatic analysis of ‘omics data from merged datasets. However, aggregating datasets can introduce unwanted variation including 1) differences in sample handling, processing, and sequencing platforms between datasets (technical variation) as well as 2) differences in experimental design between datasets. Methods: In the present study, NASA GeneLab-hosted RNAseq datasets from mouse liver tissues were used to evaluate several statistical methods to correct for this unwanted variation through two approaches, reference-based and standard. The following correction algorithms were applied with (reference-based) and/or without (standard) considering Universal Mouse RNA Reference samples: ComBat and ComBat_seq from the SVA package, the median polish, empirical Bayes, and ANOVA-based algorithms from the MBatch package, and negative binomial regression normalization in the DESeq2 package. For each approach, after the correction algorithm was applied, differential gene expression (DGE) analysis of flight and ground control samples was performed with the combined data. The robustness of each tool was evaluated using BatchQC to determine statistical differences between datasets before and after correction, Principal Component Analysis to evaluate global gene expression in samples before and after correction, and by comparing DGE analysis of individual datasets and combined datasets before and after correction. Results: The results showed that the reference-based approach introduced several additional (and likely artificial) differentially expressed genes when compared with the respective standard approach. Conclusions: Of the methods tested, standard ComBat_seq and DESeq2 were identified as the most robust correction methods for combining spaceflight mouse liver RNAseq datasets hosted on GeneLab.

Finsam Samson↗

Promoted Combustion Behavior of 316 Stainless Steel and 6061 Aluminum Alloys in Elevated Pressure Nitrox Environments

Promoted combustion testing (outlined in the ASTM G124 “Standard Test Method for Determining the Combustion Behavior of Metallic Materials in Oxygen Enriched Atmospheres”) refers to a useful testing method to evaluate how metallic materials will behave when combusted in environments with high oxygen concentrations, elevated pressure, or both. These tests yield data which is useful for engineers and scientists from a variety of industries who need and rely on oxygen systems. Oxygen Compatibility Assessments (OCA’s) are vital for ensuring that materials will be safe for use, and these assessments rely on data from OCA’s or interpolation if a desired pressure/concentration is outside of previously tested bounds. It was identified that these bounds leave out significant areas of data for materials which are tested at high pressures (above 1500 psi) and variable oxygen concentrations (with nitrogen as the diluent gas). For this reason, the authors posited that conducting promoted combustion testing on materials above 1500 psi and in various concentrations of oxygen would be incredibly useful in future analyses for oxygen compatibility with similar environments (such as breathing air) as well as for further understanding of how materials behave at very high pressures (such as 10000 psi). Two materials were selected which are commonly used in industry today - 316 stainless steel and 6061 aluminum – and they were tested and analyzed for the purposes of this study.

oxygen compatibility↗

Test Methodology to Evaluate the Safety of Materials Using Spark Incendivity

For many years scientists and engineers have been searching for the proper test method to evaluate an electrostatic risk for materials used in hazardous environments. A new test standard created by the International Electrotechnical Commission is a promising addition to conventional test methods used throughout industry. The purpose of this paper is to incorporate this test into a proposed new methodology for the evaluation of materials exposed to flammable environments. However, initial testing using this new standard has uncovered some unconventional behavior in materials that conventional test methods were thought to have reconciled. For example some materials tested at higher humidities were more susceptible to incendive discharges than at lower humidity even though the surface resistivity was lower.

Buhler, Charles↗

Development of Standardized Lunar Regolith Simulant Materials

Lunar exploration requires scientific and engineering studies using standardized testing procedures that ultimately support flight certification of technologies and hardware. It is necessary to anticipate the range of source materials and environmental constraints that are expected on the Moon and Mars, and to evaluate in-situ resource utilization (ISRU) coupled with testing and development. Physical properties of the regolith dominate processes such as excavation and drilling, while chemical properties dominate processes such as elemental extraction. We describe here the development of standardized lunar regolith simulant (SLRS) materials that are traceable interlaboratory standards for testing and technology development. These SLRS materials must simulate the lunar regolith in terms of physical, chemical, and mineralogical properties. A comprehensive simulant development program has been outlined and is in progress. A summary of these issues is contained in the 2005 Workshop on Lunar Regolith Simulant Materials

Carpenter, P.↗

Design and evaluation of the MAMMI dedicated breast PET

Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV-750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF STANDARDIZED LUNAR REGOLITH SIMULANT MATERIALS

Lunar exploration activities require scientific and engineering studies that use standardized testing procedures and ultimately support flight certification of hardware and the development of technologies for their use on the lunar surface. It is necessary to anticipate the full range of source materials and environmental constraints that are expected on the Moon and Mars, and to evaluate in-situ resource utilization (ISRU) coupled with testing and development. Historical use of lunar simulants has focused on physical aspects of the lunar regolith for landing and transportation activities. Lunar mare simulants MLS-1 and JSC-1 have been developed, but supplies have been exhausted. Renewed emphasis on exploration and ISRU activities requires development of standardized simulant reference materials that are traceable interlaboratory standards for testing and simulate the lunar regolith in terms of physical, chemical, and mineralogical properties. This new generation of lunar regolith simulants must therefore support both technological development and testing methods. These issues were extensively discussed at the 2005 Lunar Regolith Simulant Materials Workshop.

Carpenter, P.↗

Testing Protocol for Module Encapsulant Creep (Presentation)

Recently there has been an interest in the use of thermoplastic encapsulant materials in photovoltaic modules to replace chemically crosslinked materials, e.g., ethylene-vinyl acetate. The related motivations include the desire to: reduce lamination time or temperature; use less moisture-permeable materials; or use materials with better corrosion characteristics. However, the use of anythermoplastic material in a high-temperature environment raises safety and performance concerns, as the standardized tests currently do not expose the modules to temperatures in excess of 85C, yet modules may experience temperatures above 100C in operation. Here we constructed eight pairs of crystalline-silicon modules and eight pairs of glass/encapsulation/glass mock modules using differentencapsulation materials of which only two were designed to chemically crosslink. One module set was exposed outdoors with insulation on the back side in Arizona in the summer, and an identical set was exposed in environmental chambers. High precision creep measurements and performance measurements indicate that despite many of these polymeric materials being in the melt state at some of thehighest outdoor temperatures achievable, very little creep was seen because of their high viscosity, temperature heterogeneity across the modules, and in the case of the crystalline-silicon modules, the physical restraint of the backsheet. These findings have very important implications for the development of IEC and UL qualification and safety standards, and in regards to the necessary level ofcure during the processing of crosslinking encapsulants.

14 SOLAR ENERGY↗

CONSTRAINT-INDEPENDENT CONSTANT CTOA DETERMINATION FOR DUCTILE STABLE CRACK GROWTH

Crack tip opening angle (CTOA) has been used as a reliable fracture toughness parameter for decades to characterize stable ductile crack growth for thin-walled aerospace structures in the low-constraint conditions. Recently, the CTOA parameter was also applied to the pipeline industry, and a CTOA test standard ASTM E3039 was thus developed for testing a critical constant CTOA. Research showed that the constant CTOA can reasonably describe fracture toughness required to arrest a dynamic crack propagation for a modern gas pipeline. However, the CTOA fracture criterion requires constraint-independent CTOA toughness against stable ductile crack growth. ASTM E3039 recommends a drop weight tearing test (DWTT) specimen for CTOA testing. Since a shallow crack is used, DWTT measured CTOA may depend on constraint level at the crack tip. To understand if it is the case, this paper evaluates the critical CTOA for a set of fracture toughness tests on single edge notched bend (SENB) specimens with shallow and deep cracks based on four CTOA estimation models. In which, the Ln(P)-LLD linear fit model is similar to that used by ASTM E3039 in the CTOA calculation. Fracture test data for X80 pipeline steel and HY80 structural steel are considered in the CTOA evaluation. The results show that the four CTOA models can determine a crack size-independent constant CTOA over stable ductile crack growth for the SENB specimens. As a result, CTOA determined by ASTM E3039 is constraintindependent and transferable to use for an actual crack propagating in a gas pipeline.

Zhu, Xian-Kui↗

Sorption (Kd) measurements on cinder block and grout in support of dose assessments for Zion Nuclear Station decommissioning

The Zion Nuclear Power Station is being decommissioned. ZionSolutions proposes to leave much of the below grade structures in place and to fill them with a backfill to provide structural support. Backfills under consideration include “clean” concrete demolition debris from the above grade parts of the facility, a flowable grout, cinder block construction debris and sand. A previous study (Yim, 2012) examined the sorption behavior of five nuclides (Fe-55, Co-60, Ni-63, Sr-85, and Cs-137) on concrete and local soils. This study, commissioned by ZionSolutions and conducted by the Brookhaven National Laboratory (BNL) examines the sorption behavior on cinder block and grout materials. Specifically, this study measured the distribution coefficient for four radionuclides of concern using site-groundwater and cinder block from the Zion site and a flowable grout. The distributions coefficient is a measure of the amount of the radionuclide that will remain sorbed to the solid material that is present relative to the amount that will remain in solution. A high distribution coefficient indicates most of the radionuclide will remain on the solid material and will not be available for transport by the groundwater. The radionuclides examined in this set of tests were Co-60, Ni-63, Sr-85, and Cs-137. Tests were performed following ASTM C1733-10, Standard Test Methods for Distribution Coefficients of Inorganic Species by the Batch Method. Sr-85 was used in the testing as an analogue for Sr-90 because it behaves similarly with respect to sorption and has a gamma emission that is easier to detect than the beta emission from Sr-90.

54 ENVIRONMENTAL SCIENCES↗

Sorption (K d ) Measurements in Support of Dose Assessments for Zion Nuclear Station Decommissioning

The Zion Nuclear Power Station is being decommissioned. ZionSolutions proposes to leave much of the below grade structures in place and to fill them with “clean” concrete demolition debris from the above grade parts of the facility. This study, commissioned by ZionSolutions and conducted by the Brookhaven National Laboratory (BNL) was performed to provide site-specific data for performance assessment calculations to support the request to terminate the NRC license and allow unrestricted use of the facility. Specifically, this study measured the distribution coefficient for five radionuclides of concern using site-specific soils and groundwater. The distributions coefficient is a measure of the amount of the radionuclide that will remain sorbed to the soil or concrete that is present relative to the amount that will remain in solution. A high distribution coefficient indicates most of the radionuclide will remain on the solid material and will not be available for transport by the groundwater. The radionuclides of concern are Fe-55, Co-60, Ni-63, Sr-90, and Cs-137. Tests were performed following ASTM C1733-10, Standard Test Methods for Distribution Coefficients of Inorganic Species by the Batch Method. Sr-85 was used in the testing as an analogue for Sr-90 because it behaves similarly with respect to sorption and has a gamma emission that is easier to detect than the beta emission from Sr-90. Site-specific soils included disturbed sand (sand removed during construction and used as backfill), native sand, silt/clay and silt. In addition, concrete cores from the Unit-1 Containment Building and the Crib House were broken into particles less than 2 mm in size and tested to obtain distribution coefficients for the five nuclides.

54 ENVIRONMENTAL SCIENCES↗

Thermal blanket metallic film groundstrap and second surface mirror vulnerability to arc discharges

Available data on the geosynchronous orbit energetic plasma environment were examined, and a crude model was generated to permit an estimation to be made of the number of arc discharges per year to which a thermal blanket groundstrap would be subjected. Laboratory experiments and a survey of the literature on arc discharge characteristics were performed to define typical and worst case arc discharge current waveforms. In-air tests of different groundstrap configurations to a standardized test pulse were performed and a wide variability of durability values were found. A groundstrap technique, not used thus far, was found to be far superior than the others.

Inouye, G. T.↗

Report on JANNAF panel on shotgun/relative quickness testing

As the need for more energetic solid propellants continues, a number of problems arises. One of these is the tendency of high energy propellants to transition from burning (deflagration) to detonation in regions where the propellant is present in small particle sizes; e.g., in case bonding areas of a motor after a rapid depressurization causes a shear zone at the bond interface as the stressed propellant and motor case relax at different rates. In an effort to determine the susceptibility of propellants to high strain rate break up (friability), and subsequent DDT, the propulsion community uses the shotgun/relative quickness test as one of a number of screening tests for new propellant formulations. Efforts to standardize test techniques and equipment are described.

Gould, R. A.↗

Static tensile and tensile creep testing of five ceramic fibers at elevated temperatures

Static tensile and tensile creep testing of five ceramic fibers at elevated temperature was performed. J.P. Stevens, Co., Astroquartz 9288 glass fiber, Nippon Carbon, Ltd., (Dow Corning) Nicalon NLM-102 silicon carbide fiber, and 3M Company Nextel 312, 380, and 480 alumina/silica/boria fibers were supplied in unsized tows. Single fibers were separated from the tows and tested in static tension and tensile creep. Elevated test temperatures ranged from 400 to 1300 C and varied for each fiber. Room temperature static tension was also performed. Computer software was written to reduce all single fiber test data into engineering constants using ASTM Standard Test Method D3379-75 as a reference. A high temperature furnace was designed and built to perform the single fiber elevated temperature testing up to 1300 C. A computerized single fiber creep apparatus was designed and constructed to perform four fiber creep tests simultaneously at temperatures up to 1300 C. Computer software was written to acquire and reduce all creep data.

Zimmerman, Richard S.↗

Static tensile and tensile creep testing of five ceramic fibers at elevated temperatures

Static tensile and tensile creep testing of five ceramic fibers at elevated temperature was performed. J.P. Stevens, Co., Astroquartz 9288 glass fiber; Nippon Carbon, Ltd., (Dow Corning) nicalon NLM-102 silicon carbide fiber; and 3M Company Nextel 312, 380, and 480 alumina/silica/boria fibers were supplied in unsized tows. Single fibers were separated from the tows and tested in static tension and tensile creep. Elevated test temperatures ranged from 400 C to 1300 C and varied for each fiber. Room temperature static tension was also performed. Computer software was written to reduce all single fiber test data into engineering constants using ASTM Standard Test Method D3379-75 as a reference. A high temperature furnace was designed and built to perform the single fiber elevated temperature testing up to 1300 C. A computerized single fiber creep apparatus was designed and constructed to perform four fiber creep tests simultaneously at temperatures up to 1300 C. Computer software was written to acquire and reduce all creep data.

Zimmerman, Richard S.↗

Quality Control Method for a Micro-Nano-Channel Microfabricated Device

A variety of silicon-fabricated devices is used in medical applications such as drug and cell delivery, and DNA and protein separation and analysis. When a fluidic device inlet is connected to a compressed gas reservoir, and the outlet is at a lower pressure, a gas flow occurs through the membrane toward the outside. The method relies on the measurement of the gas pressure over the elapsed time inside the upstream and downstream environments. By knowing the volume of the upstream reservoir, the gas flow rate through the membrane over the pressure drop can be calculated. This quality control method consists of measuring the gas flow through a device and comparing the results with a standard curve, which can be obtained by testing standard devices. Standard devices can be selected through a variety of techniques, both destructive and nondestructive, such as SEM, AFM, and standard particle filtration.

Grattoni, Alessandro↗