Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Vacuum Testing Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Propulsion System Testing for the Iodine Satellite (iSAT) Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (less than 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. An iodine-based system is not without its challenges. The primary challenge is that the entire feed system must be maintained at an elevated temperature to prevent the iodine from depositing (transitioning from the gas phase directly back into the solid phase), which will block the propellant feed lines. Furthermore, deposition will occur unless the temperature in the lines is not greater than the temperature of the propellant reservoir. The flow rate can be controlled by adjusting the heating applied to the reservoir, but as with any thermal control there is a relatively slow response to changes in the heating rate. In the present paper, we describe the propulsion and propellant feed system for the iodine satellite (iSAT) flight demonstration mission. The system is based around the Busek BHT-200 Hall thruster, which has been modified for chemical compatibility with iodine vapor. While the gross propellant flow rate is maintained by the heated propellant reservoir, the flow to the anode and cathode are adjusted using two heated Vacco proportional flow control valves (PFCV), which provide very fast response on the flow rate adjustment. The flight mission design layout will be presented, showing how the system will be packaged into the overall 12-U spacecraft and the techniques being employed to protect the remaining spacecraft hardware from the propulsion system (e.g., plasma impingement, iodine deposition, thermal loads). In addition to the flight system design, results of testing the thruster and cathode with both operating on iodine propellant are presented. The tests are conducted on a thrust stand (see Fig. 1) in a large vacuum chamber containing a beam dump chilled to below -100 C to 'cryopump' the propellant. The thruster performance during these tests is presented, with these data used to evaluate the feed system and guide further refinements. Results of relatively long duration testing are presented to demonstrate the capability to operate for the length of the iSAT mission and to perform a number of re-starts as will be required by the mission concept of operations.

Polzin, Kurt A.↗

Voyager spacecraft electrostatic discharge testing

The program of environmental testing undergone by the Voyager spacecraft in order to simulate the transient voltage effects of electrostatic discharges expected in the energetic plasma environment of Jupiter is reported. The testing consists of studies of the electrostatic discharge characteristics of spacecraft dielectrics in a vacuum-chamber-electron beam facility, brief piece part sensitivity tests on such items as a MOSFET multiplexer and the grounding of the thermal blanket, and assembly tests of the magnetometer boom and the science boom. In addition, testing of a complete spacecraft was performed using two arc sources to simulate long and short duration discharge sources for successive spacecraft shielding and grounding improvements. Due to the testing program, both Voyager 1 and Voyager 2 experienced tolerable electrostatic discharge-caused transient anomalies in science and engineering subsystems, however, a closer duplication of the spacecraft environment is necessary to predict and design actual spacecraft responses more accurately.

Whittlesey, A.↗

Method of Generating Transient Equivalent Sink and Test Target Temperatures for Swift BAT

The NASA Swift mission has a 600-km altitude and a 22 degrees maximum inclination. The sun angle varies from 45 degrees to 180 degrees in normal operation. As a result, environmental heat fluxes absorbed by the Burst Alert Telescope (BAT) radiator and loop heat pipe (LHP) compensation chambers (CCs) vary transiently. Therefore the equivalent sink temperatures for the radiator and CCs varies transiently. In thermal performance verification testing in vacuum, the radiator and CCs radiated heat to sink targets. This paper presents an analytical technique for generating orbit transient equivalent sink temperatures and a technique for generating transient sink target temperatures for the radiator and LHP CCs. Using these techniques, transient target temperatures for the radiator and LHP CCs were generated for three thermal environmental cases: worst hot case, worst cold case, and cooldown and warmup between worst hot case in sunlight and worst cold case in the eclipse, and three different heat transport values: 128 W, 255 W, and 382 W. The 128 W case assumed that the two LHPs transport 255 W equally to the radiator. The 255 W case assumed that one LHP fails so that the remaining LHP transports all the waste heat from the detector array to the radiator. The 382 W case assumed that one LHP fails so that the remaining LHP transports all the waste heat from the detector array to the radiator, and has a 50% design margin. All these transient target temperatures were successfully implemented in the engineering test unit (ETU) LHP and flight LHP thermal performance verification tests in vacuum.

Choi, Michael K.↗

Technical Capability Upgrades to the NASA Langley Research Center 8 ft. by 15 ft. Thermal Vacuum Chamber

The 8 ft. by 15 ft. thermal vacuum chamber (TVAC), housed in Building 1250 at the NASA Langley Research Center (LaRC), and managed by the Systems Integration and Test Branch within the Engineering Directorate, has undergone several significant modifications to increase testing capability, safety, and quality of measurements of articles under environmental test. Significant modifications include: a new nitrogen distribution manifold for supplying the shroud and other cold surfaces to liquid nitrogen temperatures; a new power supply and distribution system for accurately controlling a quartz IR lamp suite; a suite of contamination monitoring sensors for outgassing measurements and species identification; a new test article support system; signal and power feed-throughs; elimination of unnecessary penetrations; and a new data acquisition and control commanding system including safety interlocks. This paper will provide a general overview of the LaRC 8 ft. by 15 ft. TVAC chamber, an overview of the new technical capabilities, and will illustrate each upgrade in detail, in terms of mechanical design and predicted performance. Additionally, an overview of the scope of tests currently being performed in the chamber will be documented, and sensor plots from tests will be provided to show chamber temperature and pressure performance with actual flight hardware under test.

Thornblom, Mark N.↗

Finite Element Thermal Model for Ultrasonic Welding of Thermoplastic Composites

Ultrasonic welding, UW, is a fast and energy-efficient technique for joining thermoplastic composites. It involves the use of high-frequency mechanical vibrations and a static welding force to melt and join adherends. Ultrasonic welding is an enabling technology to reduce the cost and complexity of in-space construction because lightweight thermoplastic composite components can be packaged compactly for launch and then efficiently assembled using supervised autonomous robotic technologies on site. However, the temperatures in space present challenges to UW, and it is critical that the efficacy of process parameters selected for manufacturing in space is understood prior to launch. To this end, a three-dimensional finite element model is presented in this technical presentation. The model incorporates equations for effects of viscoelastic heating and heat transfer on the welding process. The proposed model is applied to predict the temperature distribution in single lap shear, SLS, samples composed of AS4/PEEK (TC1200) composite that were welded using a terrestrial machine as part of a comprehensive weldability study. Thermocouple and infrared spot sensor data from the SLS samples provide empirical temperature measurements for calibration and validation of the UW thermal model. Calibration and validation of the model is an important step given the significant uncertainties in material properties such as the loss modulus and necessary assumptions in the physics implementations which allow the model to converge in an acceptable amount of time. The validated thermal model can be used to simulate the process for the space environment. Future validation sample testing is planned in a vacuum chamber. The result will be a model capable of guiding process parameter selection to ensure acceptable weld bonds when manufacturing in space.

Josh Fody↗

NASA MSFC Lunar Surface Simulator (LSS): A Facility for Lunar Relevant Environment Testing

NASA will resume crewed visits to the lunar surface beginning in the mid-2020s. Environmental testing is essential to developing and validating the hardware that will enable a sustained presence on the lunar surface. Lunar dust is one of the most pressing challenges that threatens the longevity of mechanical systems as well as the health of astronauts living and working on the Moon. Facilities that allow large pieces of hardware to be exposed to both lunar dust and the temperature and vacuum of the lunar environment are invaluable to the agency as well as to the broader community of international, academic, and industry partners with which the agency collaborates. Marshall Space Flight Center has outfitted one of its largest thermal vacuum chambers with regolith simulant beds to create the Lunar Surface Simulator (LSS).

Relevant environment testing↗

Electrostatic Discharges from Conductive Thermal Coatings

Selecting the correct thermal control coating for a spacecraft can be a significant challenge. From the start, the process includes balancing conflicting needs. Thermal control paints must have the ability to either absorb or emit heat as desired and this property cannot change beyond a set point over the life of the mission. When the mission involves operating in a heavy charging environment, the control coating must be static dissipative enough to bleed away absorbed energetic electrons to minimize induced electric fields and the risk of electrostatic discharges. Finding the right balance of thermal performance and electrical performance can be difficult for spacecraft designers. In an effort to aid in spacecraft design, a number of white and black thermal control coatings were tested at the Jet Propulsion Laboratory using a two-part test campaign. These tests involved an initial screening test to determine the bulk resistivity of the material using a traditional parallel plate test, but placed in a vacuum chamber immersed in a bath of liquid nitrogen to obtain data over a range of temperatures. The most promising materials were then exposed to a stream of energetic electrons and monitored for the production of electrostatic discharges. Results from these tests indicated that only a few of the common thermal control coatings have a resistivity below 109 ohm-cm as suggested in NASA-HDBK-4002A. Of those that meet this criterion, most will still produce electrostatic discharges when exposed to electrons with energies from 20keV to 60keV while held at cryogenic temperatures. Additional testing is required to characterize additional coatings to create a database that designers may use when selecting an appropriate coating for their application.

Chinn, James↗

Gas flow analysis during thermal vacuum test of a spacecraft

The self-contamination of the IMP-H spacecraft, while it was undergoing thermal and solar vacuum tests, has been investigated in conjunction with the outgassing evaluation and detection of molecular flow anomalies occurring in the test chamber. The pressures indicated by two tubulated ionization gauges were used to calculate flow kinetics in the vacuum chamber. The fluxes of emitted molecules and chamber wall reflected molecules were monitored during the entire test. Representative equations and graphs are presented. Test results indicate that from 3 to 9 of every 100 emitted molecules returned to the spacecraft surface; that self-contamination by noncondensable gases was more severe than that by condensable gases; and that outgassing of the spacecraft was approximately 1.18 x 0.01 g/s after 10 hours and 1.18 x 0.001 after 90 hours of vacuum exposure. Testing deficiencies have been identified, and the type and location of instruments required to measure the outgassing, the degree of contamination, and return flow are discussed.

Scialdone, J. J.↗

Cryogenic testing of Planck sorption cooler test facility

A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.

Planck sorption cooler↗

Simulated space environment tests on cadmium sulfide solar cells

Cadmium sulfide (Cu2s - CdS) solar cells were tested under simulated space environmental conditions. Some cells were thermally cycled with illumination from a Xenon-arc solar simulator. A cycle was one hour of illumination followed immediately with one-half hour of darkness. In the light, the cells reached an equilibrium temperature of 60 C (333 K) and in the dark the cell temperature dropped to -120 C (153 K). Other cells were constantly illuminated with a Xenon-arc solar simulator. The equilibrium temperature of these cells was 55 C (328 K). The black vacuum chamber walls were cooled with liquid nitrogen to simulate a space heat sink. Chamber pressure was maintained at 0.000001 torr or less. Almost all of the solar cells tested degraded in power when exposed to a simulated space environment of either thermal cycling or constant illumination. The cells tested the longest were exposed to 10.050 thermal cycles.

Clarke, D. R.↗

The New LOTIS Test Facility

The Large Optical Test and Integration Site (LOTIS) at the Lockheed Martin Space Systems Company in Sunnyvale, CA is designed for the verification and testing of optical systems. The facility consists of an 88 foot temperature stabilized vacuum chamber that also functions as a class 10k vertical flow cleanroom. Many problems were encountered in the design and construction phases. The industry capability to build large chambers is very weak. Through many delays and extra engineering efforts, the final product is very good. With 11 Thermal Conditioning Units and precision RTD s, temperature is uniform and stable within 1oF, providing an ideal environment for precision optical testing. Within this chamber and atop an advanced micro-g vibration-isolation bench is the 6.5 meter diameter LOTIS Collimator and Scene Generator, LOTIS alignment and support equipment. The optical payloads are also placed on the vibration bench in the chamber for testing. This optical system is designed to operate in both air and vacuum, providing test imagery in an adaptable suite of visible/near infrared (VNIR) and midwave infrared (MWIR) point sources, and combined bandwidth visible-through-MWIR point sources, for testing of large aperture optical payloads. The heart of the system is the LOTIS Collimator, a 6.5m f/15 telescope, which projects scenes with wavefront errors <85 nm rms out to a 0.75 mrad field of view (FOV). Using field lenses, performance can be extended to a maximum field of view of 3.2 mrad. The LOTIS Collimator incorporates an extensive integrated wavefront sensing and control system to verify the performance of the system.

Bell, R. M.↗

Swift Observatory Space Simulation Testing

The Swift Observatory is a Middle-Class Explorer (MIDEX) mission that is a rapidly re-pointing spacecraft with immediate data distribution capability to the astronomical community. Its primary objectives are to characterize and determine the origin of Gamma Ray Bursts (GRBs) and to use the collected data on GRB phenomena in order to probe the universe and gain insight into the physics of black hole formation and early universe. The main components of the spacecraft are the Burst Alert Telescope (BAT), Ultraviolet and Optical Telescope (UVOT), X-Ray Telescope (XRT), and Optical Bench (OB) instruments coupled with the Swift spacecraft (S/C) bus. The Swift Observatory will be tested at the Space Environment Simulation (SES) chamber at the Goddard Space Flight Center from May to June 2004 in order to characterize its thermal behavior in a vacuum environment. In order to simulate the independent thermal zones required by the BAT, XRT, UVOT, and OB instruments, the spacecraft is mounted on a chariot structure capable of maintaining adiabatic interfaces and enclosed in a modified, four section MSX fixture in order to accommodate the strategic placement of seven cryopanels (on four circuits), four heater panels, and a radiation source burst simulator mechanism. There are additionally 55 heater circuits on the spacecraft. To mitigate possible migration of silicone contaminants from BAT to the XRT and UVOT instruments, a contamination enclosure is to be fabricated around the BAT at the uppermost section of the MSX fixture. This paper discuses the test requirements and implemented thermal vacuum test configuration for the Swift Observatory.

Espiritu, Mellina↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

Thermal Vacuum Testing of a Proto-flight Miniature Loop Heat Pipe with Two Evaporators and Two Condensers

This paper describes thermal vacuum testing of a proto-flight miniature loop heat pipe (MLHP) with two evaporators and two condensers designed for future small systems applications requiring low mass, low power and compactness. Each evaporator contains a wick with an outer diameter of 6.35 mm, and each has its own integral compensation chamber (CC). Miniaturization of the loop components reduces the volume and mass of the thermal system. Multiple evaporators provide flexibility for placement of instruments that need to be maintained at the same temperature, and facilitate heat load sharing among instruments, reducing the auxiliary heater power requirement. A flow regulator is used to regulate heat dissipations between the two condensers, allowing flexible placement of radiators on the spacecraft. A thermoelectric converter (TEC) is attached to each CC for control of the operating temperature and enhancement of start-up success. Tests performed include start-up, power cycle, sink temperature cycle, high power and low power operation, heat load sharing, and operating temperature control. The proto-flight MLHP demonstrated excellent performance in the thermal vacuum test. The loop started successfully and operated stably under various evaporator heat loads and condenser sink temperatures. The TECs were able to maintain the loop operating temperature within b1K of the desired set point temperature at all power levels and all sink temperatures. The un-powered evaporator would automatically share heat from the other powered evaporator. The flow regulator was able to regulate the heat dissipation among the radiators and prevent vapor from flowing into the liquid line.

Ku, Jentung↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗