Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trace contaminants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Apparatus Removes Organic Contaminants From Water

Catalytic-oxidation apparatus removes low-molecular-weight, polar, nonionizable organic contaminants from wastewater. Wastewater stream, previously treated by multifiltration process, pumped through apparatus for removal of trace organic contaminants. After injection of oxygen, flow preheated and enters catalytic reactor, where organic contaminants broken down into carbon dioxide and water. Carbon dioxide and unused oxygen removed in degasser.

Akse, James R.↗

Surface Processes Control the Fate of Reactive Oxidants Generated by Electrochemical Activation of Hydrogen Peroxide on Stainless-Steel Electrodes

Low-cost stainless-steel electrodes can activate hydrogen peroxide (H 2 O 2 ) by converting it into a hydroxyl radical ( • OH) and other reactive oxidants. At an applied potential of +0.020 V, the stainless-steel electrode produced • OH with a yield that was over an order of magnitude higher than that reported for other systems that employ iron oxides as catalysts under circumneutral pH conditions. Decreasing the applied potential at pH 8 and 9 enhanced the rate of H 2 O 2 loss by shifting the process to a reaction mechanism that resulted in the formation of an Fe(IV) species. Significant metal leaching was only observed under acidic pH conditions (i.e., at pH <6), with the release of dissolved Fe and Cr occurring as the thickness of the passivation layer decreased. Despite the relatively high yield of • OH production under circumneutral pH conditions, most of the oxidants were scavenged by the electrode surface when contaminant concentrations comparable to those expected in drinking water sources were tested. The stainless-steel electrode efficiently removed trace organic contaminants from an authentic surface water sample without contaminating the water with Fe and Cr. With further development, stainless-steel electrodes could provide a cost-effective alternative to other H 2 O 2 activation processes, such as those by ultraviolet light.

42 ENGINEERING↗

Quantifying Moss Response to Metal Contaminant Exposure Using Laser-Induced Fluorescence

Tracing sources of contamination, including potentially toxic elements (PTEs), has historically been achieved through sampling and analysis of soil or biota, which are labor-intensive, costly, and destructive methods. Thus, availability of a non-destructive in situ remote sensing method for monitoring metals deposited in biota is of great interest. Laser-induced fluorescence (LIF) is an emerging spectroscopic and imaging technique that documents changes in molecular energy level in plants as a biological response to metal contamination. For a proof-of-concept study and preliminary experiment, moss was selected for experimentation due to its long history of use in tracing atmospheric deposition of PTEs. Consecutive treatments of copper chloride (CuCl2) were administered to three moss samples, simulating wet deposition every 48 h over 10 days until reaching cumulative Cu concentrations of 2.690 to 8.075 μmol/cm2. While these Cu amounts are above environmentally relevant concentrations, they allowed the best conditions for testing and fine tuning of the imaging and data processing protocols presented in this paper. Moss fluorescence was induced using both 532 nm green and 355 nm UV lasers. A CMOS camera captured images of the LIF response, and red–green–blue (RGB) decimal code values were extracted for each pixel in the images, and pixel densities of color channels from treated and untreated moss samples were compared. Results show a shift towards lower color decimal codes corresponding to increased Cu concentration. We developed and contrasted multiple quantitative analyses of color distributions and demonstrated that LIF shows great promise for remote sensing of Cu accumulation in moss at μmol/cm2 levels. Though currently, the method would be limited to highly toxic sites, it illustrates the possibility and provides a framework for development of higher-sensitivity methods to detect nmol/cm2 that are viable for urban contamination level monitoring.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Monitoring complex trace-gas mixtures by long-path laser absorption spectrometry

Laser-based spectrophotometric methods, which have been proposed for the detection of trace concentrations of gaseous contaminants, include Raman and passive radiometry. The paper discusses a simple long-path laser absorption method which is capable of resolving complex mixtures of closely related trace contaminants at ppm levels. A number of species were selected which are most likely to accumulate in closed environments, such as submarines or long-duration manned space flights. Absorption coefficients at CO2 laser wavelengths were measured, accurate to + 3 per cent or better, for each of these species. This data base was then used to determine the presence and concentration of the contaminants in prepared mixtures of 12 to 15 gases. Computer programs have been developed which will permit a real-time analysis of the monitored atmosphere. Minimum detectable concentrations for individual species are generally in the ppm range, and are not seriously degraded by interferences even in complex mixtures. Estimates of the dynamic range of this monitoring technique for various system configurations and comparison with other methods of analysis are discussed

Green, B. D.↗

STS-55 pad abort: Engine 2011 oxidizer preburner augmented spark igniter check valve leak

The STS-55 initial launch attempt of Columbia (OV102) was terminated on KSC launch pad A March 22, 1993 at 9:51 AM E.S.T. due to violation of an ME-3 (Engine 2011) Launch Commit Criteria (LCC) limit exceedance. The event description and timeline are summarized. Propellant loading was initiated on 22 March, 1993 at 1:15 AM EST. All SSME chill parameters and launch commit criteria (LCC) were nominal. At engine start plus 1.44 seconds, a Failure Identification (FID) was posted against Engine 2011 for exceeding the 50 psia Oxidizer Preburner (OPB) purge pressure redline. The engine was shut down at 1.50 seconds followed by Engines 2034 and 2030. All shut down sequences were nominal and the mission was safely aborted. The OPB purge pressure redline violation and the abort profile/overlay for all three engines are depicted. SSME Avionics hardware and software performed nominally during the incident. A review of vehicle data table (VDT) data and controller software logic revealed no failure indications other than the single FID 013-414, OPB purge pressure redline exceeded. Software logic was executed according to requirements and there was no anomalous controller software operation. Immediately following the abort, a Rocketdyne/NASA failure investigation team was assembled. The team successfully isolated the failure cause to the oxidizer preburner augmented spark igniter purge check valve not being fully closed due to contamination. The source of the contaminant was traced to a cut segment from a rubber O-ring which was used in a fine clean tool during valve production prior to 1992. The valve was apparently contaminated during its fabrication in 1985. The valve had performed acceptably on four previous flights of the engine, and SSME flight history shows 780 combined check valve flights without failure. The failure of an Engine 3 (SSME No. 2011) check valve to close was sensed by onboard engine instruments even though all other engine operations were normal. This resulted in an engine shutdown and safe sequential shutdown of all three engines prior to ignition of the solid boosters.

Source record↗

Evaluating Crustal Contamination Effects on the Lithophile Trace Element Budget of Shergottites

The origin of the incompatible trace element (ITE) enriched compositions of shergottites has been a point of contention for decades [1-2]. Two scenarios have been proposed, the first is that enriched shergottite compositions reflect an ITE-enriched mantle source, whereas in the second, the ITE enrichment reflects crustal contamination of mantle-derived parent magmas. Evidence supporting the first scenario is that the ITE-enriched shergottite compositions are consistent with the outcomes of magma ocean crystallization [3], and that Os-Nd isotope relationships for shergottites cannot be explained by realistic crustal contamination models [4]. In contrast, Cl and S isotopes are consistent with shergottite magmas interacting with Mars crust [5,6], and ITE-enriched olivine-hosted melt inclusions and interstitial glass are found in depleted shergottite Yamato 980459 [7]. These findings indicate that some level of crustal interaction occurred but the question of whether ITE-enrichments in some bulk shergottites reflect crustal contamination remains open. Recently, a Mars crustal breccia meteorite has been found, NWA 7034 and its paired stones, that is our best analogue to an average of Mars ancient crust [8-10]. This allows for better constraints on crustal contamination of shergottite magmas. We modeled magma-crust mixing and assimilation-fractional crystallization (AFC) using ITE-depleted shergottite compositions and bulk NWA 7034 and its clasts as end-members. The results of these models indicate that crustal contamination can only explain the ITE-enriched compositions of some bulk shergottites under unusual circumstances. It is thus likely that the shergottite range of compositions reflects primarily mantle sources.

Brandon, A. D.↗

Microbial Ecology of NASA Curation Clean Rooms

Clean room standards like ISO 14644 used for facilities that construct spacecraft and store returned samples do not explicitly account for microbial contamination. While there are associated ISO standards for monitoring and controlling bio-contamination in clean rooms it is not always standard practice to do so. The NASA Astromaterials Acquisition and Curation Office maintains seven separate clean labs for storing extraterrestrial samples from the Moon, meteorites, cosmic dust, asteroids, comets, solar wind particles, and microparticle impact samples. These labs are routinely monitored for particulate and trace metal contamination. However, the sample collections are either non-sterile at the time of collection (e.g., meteorites) or are no longer being used to address scientific questions that could be affected by non-sterile conditions (e.g., Lunar samples). Outside of isolated studies there has not been a systematic, longitudinal characterization of the microbial ecology of NASA curation clean rooms. In accordance with the advanced curation initiative, and to prepare for future sample return missions, we have initiated a routine microbiological monitoring program in the Antarctic Meteorite Lab. This monitoring program will be used to determine what microbes are capable of surviving in these oligotrophic environments and whether or not they are capable of altering the sample collections in any significant manner. Repeat sampling will allow us to understand how routine use of these labs affects the microbial ecology over time.

Regberg, A. B.↗

Influence of Transition Metal Ion Contaminants on the Performance of Amine-Based Solid Sorbents in Direct Air Capture

Amine-functionalized solid sorbents are a class of sorbent materials proposed for direct air capture (DAC) of CO 2 , yet their long-term performance is susceptible to degradation under realistic operating conditions. Many amines are not thermodynamically stable in air, and amine sorbents oxidize while in use during DAC temperature swing adsorption processes. In this study, we investigate the role of transition metal ion contaminants, specifically Cu 2+ , Fe 2+ , and Ni 2+ , on the oxidative degradation of poly(ethylenimine) (PEI)-impregnated SBA-15 sorbents. By introducing metal ions via different modes mimicking both synthesis-related impurities and impurities derived from environmental exposure, we systematically evaluate sorbent stability after exposure to dry air at an elevated temperature. Thermogravimetric CO 2 uptake measurements reveal that even trace levels of Cu and Fe (as low as ∼4 ppm) can lead to measurable sorbent deactivation after oxidative aging, despite negligible loss in the performance of the control samples. In situ infrared, UV–vis, and X-ray photoelectron spectroscopies indicate that these metals catalyze radical-driven oxidation pathways, altering the chemical structure of the sorbent and accelerating degradation. Our findings underscore the need to account for trace metal contamination during DAC sorbent synthesis and deployment and highlight the importance of environmental contamination pathways.

CO2 capture↗

Compact Multi-Gas Monitor for Life Support Systems Control in Space: Evaluation Under Realistic Environmental Conditions

Advanced space life support systems require lightweight, low-power, durable sensors for monitoring critical gas components. A luminescence-based optical flow-through cell to monitor carbon dioxide, oxygen, and humidity has been developed and was demonstrated using bench-top instrumentation under environmental conditions relevant to portable life support systems, including initially pure oxygen atmosphere, temperature range from 50 F to 150 F, and humidity from dry to 100% RH and under conditions of water condensation. This paper presents the most recent progress in the development of this sensor technology. Trace gas contaminants in a space suit, originating from hardware and material off-gassing and crew member metabolism, are from many chemical families. The result is a gas mix much more complex than the pure oxygen fed into the space suit, and this complexity may interfere with gas sensor readings. This paper presents an evaluation of optical sensor performance when exposed to the most significant trace gases reported to be found in space suits. A study of the calibration stability of the sensors is also presented. For that purpose, a profile of temperature, pressure, humidity, and gas composition for the duration of an EVA has been defined, and the performance of sensors operated repeatedly under those conditions has been studied. Finally, this paper presents the first compact readout unit for these optical sensors, designed for the volume, power, and weight restrictions of a PLSS.

Alonso, Jesus Delgado↗

Cabin Air Quality On Board Mir and the International Space Station: A Comparison

The maintenance of the cabin atmosphere aboard spacecraft is critical not only to its habitability but also to its function. Ideally, air quality can be maintained by striking a proper balance between the generation and removal of contaminants. Both very dynamic processes, the balance between generation and removal can be difficult to maintain and control because the state of the cabin atmosphere is in constant evolution responding to different perturbations. Typically, maintaining a clean cabin environment on board crewed spacecraft and space habitats is the central function of the environmental control and life support (ECLS) system. While active air quality control equipment is deployed on board every vehicle to remove carbon dioxide, water vapor, and trace chemical components from the cabin atmosphere, perturbations associated with logistics, vehicle construction and maintenance, and ECLS system configuration influence the resulting cabin atmospheric quality. The air-quality data obtained from the International Space Station (ISS) and NASA-Mir programs provides a wealth of information regarding the maintenance of the cabin atmosphere aboard long-lived space habitats. A comparison of the composition of the trace chemical contaminant load is presented. Correlations between ground-based and in-flight operations that influence cabin atmospheric quality are identified and discussed, and observations on cabin atmospheric quality during the NASA-Mir expeditions and the International Space Station are explored.

Macatangay, Ariel↗

Similarities and Differences in the Effects of Toxic Concentrations of Cadmium and Chromium on the Structure and Functions of Thylakoid Membranes in Chlorella variabilis

Trace metal contaminations in natural waters, wetlands, and wastewaters pose serious threats to aquatic ecosystems—mainly via targeting microalgae. In this work, we investigated the effects of toxic amounts of chromium and cadmium ions on the structure and function of the photosynthetic machinery of Chlorella variabilis cells. To halt the propagation of cells, we used high concentrations of Cd and Cr, 50–50 mg L –1 , in the forms of CdCl 2 x 2.5 H 2 O and K 2 Cr 2 O 7 , respectively. Both treatments led to similar, about 50% gradual diminishment of the chlorophyll contents of the cells in 48 h, which was, however, accompanied by a small (~10%) but statistically significant enrichment (Cd) and loss (Cr) of ß-carotene. Both Cd and Cr inhibited the activity of photosystem II (PSII)—but with more severe inhibitions with Cr. On the contrary, the PsbA (D1) protein of PSII and the PsbO protein of the oxygen-evolving complex were retained more in Cr-treated cells than in the presence of Cd. These data and the higher susceptibility of P700 redox transients in Cr-treated cells suggest that, unlike with Cd, PSII is not the main target in the photochemical apparatus. These differences at the level of photochemistry also brought about dissimilarities at higher levels of the structural complexity of the photosynthetic apparatus. Circular dichroism (CD) spectroscopy measurements revealed moderate perturbations in the macro-organization of the protein complexes—with more pronounced decline in Cd-treated cells than in the cells with Cr. Also, as reflected by transmission electron microscopy and small-angle neutron scattering, the thylakoid membranes suffered shrinking and were largely fragmented in Cd-treated cells, whereas no changes could be discerned with Cr. The preservation of integrity of membranes in Cr-treated cells was most probably aided by high proportion of the de-epoxidized xanthophylls, which were absent with Cd. It can thus be concluded that beside strong similarities of the toxic effects of Cr and Cd, the response of the photosynthetic machinery of C. variabilis to these two trace metal ions substantially differ from each other—strongly suggesting different inhibitory and protective mechanisms following the primary toxic events.

59 BASIC BIOLOGICAL SCIENCES↗

Trace Metal Uptake and Mercury Methylation by Sediments from a Stream in Tennessee

The formation and transport of methylmercury (MeHg), a neurotoxin, in aquatic environments is a global concern for human health as MeHg can bioaccumulate and biomagnify to high concentrations in aquatic food webs. MeHg is formed by conversion from inorganic mercury through microbial mediated methylation. Sulfate-reducing bacteria have been identified as the primary organisms responsible for MeHg production. Pure-culture studies suggest that low availability of cobalt and copper may inhibit mercury methylation, but whether such limitations occur in the environment is unclear. To explore the possible interaction between trace metal availability and mercury methylation, sediments from the East Fork Poplar Creek in Oak Ridge, Tennessee were sampled and then incubated in the presence and absence of added dissolved cobalt and copper. Three types of data are provided in this package. The first reports the uptake of dissolved cobalt and copper by these stream sediments on short time scales (24 hours) in the form of final dissolved and adsorbed concentrations. The second data component consists of a time series of dissolved concentrations and pH values for stream sediments incubated with artificial stream water containing different addition levels of dissolved cobalt or copper. The dissolved concentrations reported include total iron, manganese, sulfur, phosphorus, nickel, zinc and cobalt, dissolved concentrations of sulfate and orthophosphate, and the amount of cobalt or copper adsorbed by the sediment. The third data component reports data at 0 and 72 hours of incubation time for stream sediments to which cobalt was added. These data include concentrations of methylmercury with isotope labeling to enable determination of methylation and demethylation rates as well as dissolved concentrations of sulfate, phosphate, chloride, iron, cobalt, and organic carbon. All data are provided in text-based CSV format with header sections indicating the data contained in each file and the corresponding units. Note that "u" is used in place of Greek lower-case mu to indicate the micro prefix on units. A Table of Contents file (Data_package_TableofContents.txt) provides an index for the data contained in the individual files.

54 ENVIRONMENTAL SCIENCES↗

Long cycle and calendar life of Si-based Li-ion batteries enabled by localized high-concentration electrolytes and their surprising water tolerance

Silicon-based anodes promise an increase in energy density for Li-ion batteries, yet they suffer from a poor calendar life. Researchers have posited that fluorinated lithium salt forms reactive side products that destroy the solid electrolyte interphase (SEI), even without cycling. HF is one such reactive side product formed from trace water contamination in the electrolyte. Some electrolytes, such as localized high concentration electrolytes (LHCEs) may improve cell stability in highly reactive systems, such as Li metal and Si. In the present study, LHCEs containing 200-300 ppm of water retained up to 8% greater capacity (1200-1300 mAh/g Si) in calendar life tests over 200 days compared to dried electrolytes (< 20 ppm water). Calendar aging took place at 100% state of charge. Cells with 200-300 ppm water performed comparably to cells with 20 ppm water in cycle life tests (900-1000 mAh/g Si) . Even adding 1000 ppm water did not lead to rapid capacity fade in cells undergoing cycle life tests. Nano-FTIR spectroscopy revealed chemical and structural differences in the SEI for cells with 1000 ppm water compared to 200-300 ppm water. The SEI differences, including increased Li2O concentration, may have contributed to improved calendar life. This research reveals the capabilities of LHCEs to improve the calendar and cycle life of Si-based Li-ion batteries, despite the presence of a highly reactive contaminant.

25 ENERGY STORAGE↗

La 3+ and Y 3+ interactions with the carboxylic acid moiety at the liquid/vapor interface: Identification of binding complexes, charge reversal, and detection limits

Specific interactions of yttrium and lanthanum ions with a fatty acid Langmuir monolayer were investigated using vibrational sum frequency spectroscopy. The trivalent ions were shown to interact with the charged form of the carboxylic acid group from nanomolar concentrations (<300 nM). Analysis of the spectral features from both the symmetric and the asymmetric carboxylate modes reveals the presence of at least three distinct coordination structures linked to specific binding configurations. Although the same species were identified for both La 3+ and Y 3+ , they display a different concentration dependence, highlighting the ion-specificity of the interaction. From the analysis of the response of interfacial water molecules, the reversal of the surface charge, as well as the formation of yttrium hydroxide complexes, were detected upon increasing the amount of salt in solution. The binding interaction and kinetics of absorption are sensitive to the solution pH, showing a distinct ion speciation in the interfacial region when compared to the bulk. Changing the subphase pH or adding a monovalent background electrolyte that promotes deprotonation of the carboxylic acid headgroup could further improve the detection limit of La 3+ and Y 3+ to concentrations < 100 nM. These findings demonstrate that nM concentrations of trace metals contaminants, typically found on monovalent salts, can significantly influence the binding structure and kinetics in Langmuir monolayers.

01 COAL, LIGNITE, AND PEAT↗

Influence of Water Sorption on Ionic Conductivity in Polyether Electrolytes at Low Hydration

Ion-containing polymers are subject to a wide range of hydration conditions across electrochemical and water treatment applications. Significant work on dry polymer electrolytes for batteries and highly swollen membranes for water purification has informed our understanding of ion transport under extreme conditions. However, knowledge of intermediate conditions (i.e., low hydration) is essential to emerging applications (e.g., electrolyzers, fuel cells, and lithium extraction). Ion transport under low levels of hydration is distinct from the extreme conditions typically investigated, and the relevant physics cannot be extrapolated from existing knowledge, stifling materials design. In this study, we conducted ion transport measurements in LiTFSI-doped polyethers that were systematically hydrated from dry conditions. A semiautomated apparatus that performs parallel measurements of water uptake and ionic conductivity in thin-film polymers under controlled humidity was developed. For the materials and swelling range considered in this study (i.e., <0.07 g water/g dry polymer electrolyte), ionic conductivity depends nonlinearly on water uptake, with the initial sorbed water weakly affecting conductivity. With additional increases in swelling, more significant increases in conductivity were observed. Remarkably, changes in conductivity induced by water sorption were correlated with the number of water molecules per lithium ion, with the normalized molar conductivity of different samples effectively collapsing onto one another until this unit of hydration exceeded the solvation number of lithium ions under aqueous conditions. Furthermore, these results provide important knowledge regarding the effects of trace water contamination on conductivity measurements in polymer electrolytes and demonstrate that the lithium-ion solvation number marks a key transition point regarding the influence of water on ion transport in ion-containing polymers.

36 MATERIALS SCIENCE↗

Stochastic simulations of temporally and spatially variable Fe cycling within a floodplain aquifer

This data package contains model input and output files for local and global sensitivity analysis (SA) of a reactive transport model simulating redox cycling within a floodplain aquifer. The reaction network is implemented in CrunchFlow and focuses on spatially and temporally heterogeneous Fe cycling, though it contains several other species and redox pathways (37 aqueous species and 7 minerals in total). The package contains data from 600 Monte Carlo simulations (for global SA) and 104 one-at-a-time simulations (for local SA). It includes all input files required to run the CrunchFlow model, as well as limited model output – .csv files containing time series of primary species concentrations at 21 grid cells within the domain. These time series files contain the following species: H+, CO32-, SO42-, Cl-, Ca2+, Mg2+, Na+, K+, Fe(II), Fe(III), HS-, CH3COO-, O2(aq), S(aq), and Br-.These data were used to demonstrate the application of a novel form of global SA, distance-based generalized sensitivity analysis (DGSA) to a reactive transport model. The 2D model simulates the export of reduced species from pockets of fine-grained, organic-rich sediments embedded in a coarse sand aquifer. Stochastic simulations jointly varied 17 key model input parameters across several orders of magnitude, including the spatial variability of each parameter. DGSA on the model results reveal that the amplitude and variability of exported Fe(II) are most sensitive to the interaction between sand permeability and individual reaction rates. By contrast, the propagation of reducing conditions downgradient from the fine-grained lenses depends most heavily on the rate of dissolved organic carbon and sulfate release from the fines.

54 ENVIRONMENTAL SCIENCES↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗